WINEGARD
Digital Elevation Sensor
Electronic Calibrated Model for RM and RD models
Model DE-4600/4646
U.S. Patent 5,945,945
DE-4600/4646 Only
Sensor w/Cable
2763236, DE-4600
2763235, DE-4646
(2) 2160216
#10-32 Hex Nut
THIS UNIT HAS
BEEN CALIBRATED
AT THE FACTORY.
No further calibration
is necessary.
(2) 2160280
1/4-20 x 2" Hex Bolt
(2) 2160172
#10-32 x 1/2"
Screw
(2) 2160039
1/4" Flat Washer
(If for some reason, this unit’s
calibration fails, See Steps 4 through
8 in this manual.)
3720503
Mounting Plate
Figure 1
Figure 2
Before you begin, take a few minutes to
look at Figure 1. Be sure you have
received all parts pertaining to your
specific model. Contact Winegard
Company for help with questions
concerning our products.
(2) 2160147
#6 x 5/8" Phillips
Head Screw
(4) 2180183
3M UR Terminal
DE-4646 Only
Customer service hours are 7:30 a.m. to
5:00 p.m., Mon. - Thu., 7:30 a.m. to 4:00
p.m., Fri., Central Time. Call toll-free
1-800-288-8094.
(7) 2190104
5-1/2" Cable Tie
DE-4600/4646
For RD models, use Steps 1 and 2.
For RM models, use Step 3.
(2) 2160104
#6 x 1/2" Hex Head
Slotted Screw
DE-4600 Only
DR-6400
Wallplate
Display Unit
DE-4600
DE-4646
SM-1000
Surface Mount Box
DE-4600 Only
Step 1. Figure 2. Assemble
Sensor to mounting plate using
the two (2) #10-32 x 1/2" screws
and #10-32 hex nuts, Figure 2.
CAUTION: Over-tightening
(2) 1/4" Flat
Washer, for
RD-4610 only Arm
Fixed Feed
screws is unnecessary and may
cause breakage of case.
Figure 3
Elevating Tube
#10-32 Hex Nut
Step 2. Figure 3. Positioning
antenna to a near vertical angle
will make installation easier.
Assemble mounting plate
against fixed feed arm by
removing existing 1/4" nuts,
bolts and washers. Using new
hex bolts and previously
Mounting Plate
Sensor
1/4-20 x 2" Hex Bolt
1/4" Flat Washer
#10-32 x 1/2" Screw
1/4" Flat Washer
1/4-20 Hex Nut
removed nuts and
washers assemble parts as
shown. Align the plate parallel,
Figure 3, to elevating tube and
tighten hardware. Go to Step 9.
CAUTION: Sensor MUST be mounted on side
that coax cable is attached to gear housing.
Mounting differently than shown WILL
CAUSE IMPROPER OPERATION.
Red
White
(+) Pos. 12VDC*
(-) Neg. Ground*
Green
Black
* CAUTION: DO NOT
connect a 9 volt battery
if using +12 VDC. 9 volt
battery is recommended.
#6 x 1/2"
Phillips Screw
(optional)
#6 x 5/8"
Phillips Screw
SM-1000 Surface Mount Box
(optional), DE-4600 only
DE-4600 only
Wallplate Display Unit
CAUTION: If using +12 VDC, it must be FILTERED!
If using non-filtered +12 VDC, the product will be damaged
andWarrantyvoided.
Figure 7
Step 7. Figure 7. If using the SM-1000 surface mount
box, feed cable through hole in box. Connect wires
coming from sensor on roof to wall plate display in
coach. It is required to strip wires 1/4". It is
Jumper
IMPORTANT to have connected the wires properly at
roof and to connect properly at wall plate. System is
designed to use a 9 volt battery (recommended) OR
+12 VDC from RV (not both). When inserting and
tightening the wires into terminals on back of display
board, be sure that you have clamped on the bare wire
conductor and not the insulation. DO NOT connect the
+12 VDC at this time. IMPROPER WIRING WILL
CAUSE DAMAGE TO THE PRODUCT.
Step 8. Figure 7. There are five pins on back of display circuit
board. Place jumper (small plastic plug in the hardware bag)
across the second and third pin from the left. These are the calibrate
pins. Install a 9 volt battery and press the button on front of display. The
readout should display the letters CA (calibration) for approximately 10 seconds. The display
will then start alternating between two sets of numbers of no importance to you. At this time
remove battery. Now remove jumper and place on the single pin to the left. Electronic
calibration is now complete.
Figure 8
WIRING
* CAUTION: DO NOT connect to +12 VDC
if using a 9 volt battery. Use of 9 volt
battery recommended.
Step 9. Use the 9 volt battery (9 volt
recommended for best performance) or
hook up the +12 VDC. Pressing the
button should display 24 (+ or - 1 degree)
when antenna is in vertical position.
Display automatically turns off after
approximately 1 minute.
Slide battery
into place
and cinch the
cable tie
moderately
tight. Clip off
excess tie.
Step 10. Figure 8. It is recommended if
using 9 volt battery, a cable tie be
installed to secure the battery. The tie
should not be too tight because the
battery will need to slide out for
replacement.
Wallplate display with
battery and sensor
cable attached.
STEP 11. CHECK CONNECTORS AND
CABLE ENTRY POINTS. MAKE SURE
THESE AREAS HAVE BEEN
PROPERLY SEALED TO PREVENT
WATER DAMAGE TO YOUR SYSTEM
AND PROPERTY.
sure to feed cable
under the display
dout. (Wallplate not
wn for clarity.)
Troubleshooting — EE readings on
display: Check wiring for poor connection
or incorrect wiring.
OPERATING INSTRUCTIONS
Step 1. Using satellite receiver, determine correct
elevation for your location. See your receiver manual for
details on how to obtain setup information.
Special Notes: When you have detected the satellite
signal adjust the antenna up/down and left/right for
strongest signal your receiver displays. Due to variations
in receivers and installation methods, you may find the
elevation numbers after peaking on strongest signal no
longer match what the receiver recommended. This is
normal. The elevation sensor should always get you close
enough to pick up a signal to peak on. If display turns off
while you’re searching, just push button for another
minute of operation. After a little practice, most people
find the signal in 30 to 50 seconds.
Step 2. Press button on Winegard Digital Display Wall
plate. If antenna is in travel position, the display will show
HH for high limit. (LL for low limit.)
Step 3. Crank elevation handle to raise antenna. Stop
cranking when readout displays correct elevation for your
location. (Found on receiver setup menu.)
Step 4. Rotate antenna VERY SLOWLY until correct
satellite signal is acquired. NOTE: Rotate 2° and stop. DO
NOT rotate continuously even if you are rotating slowly. If
you notice elevation angle has changed, it could be due
the following reasons:
Replacement Parts
To order repair parts, contact Winegard Company.
Customer service hours are 7:30 a.m. to 5:00 p.m.,
Mon. - Thu., 7:30 a.m. to 4:00 p.m., Fri., Central Time.
Call toll-free 1-800-288-8094. Credit card only, $5.00
minimum order. For parts, refer to page one of this
instruction sheet.
1. RV is not parked level.
2. Antenna system is mounted to a slightly sloped RV
roof. If this is the reason, when you have rotated the
antenna so it is facing in the approximate correct azimuth
(compass direction), simply adjust to correct elevation
and continue searching for signal.
Printed in U.S.A. Winegard Company • 3000 Kirkwood St. • Burlington, Iowa 52601-2000 © 2000 Winegard Company 2451955 Rev. 9/11/00
|