88  
Water & Steam Boilers – Series 2  
For Gas, Light Oil, & Gas/Light Oil – Fired Burners  
Beckett  
Burner Specification  
& Data Sheet  
Oil Burners  
Models CF1400-W, CF2300A-W,  
CF2500-W, CF3500A-W  
Figure 1 Model CF1400-W  
Figure 2 Model CF2300A-W  
Dimensions in Inches  
Overall Motor Size  
Burner  
Model  
Number  
Length  
Standard Motor  
Electrical  
Characteristics  
Optional Motor  
Electrical  
Characteristics  
(From Mounting Flange To  
Label Area On Burner Front)  
Width  
H.P.  
208-240/60/1*  
208-240-480/60/3  
CF1400-W  
20.75  
21.25  
22.50  
24.00  
1/2  
3/4  
120/60/1  
120/60/1  
208-240/60/1*  
208-240-480/60/3  
CF2300A-W  
CF2500-W  
23.50  
23.50  
27.00  
27.00  
2
2
240/60/1  
240/60/1  
208-240-480/60/3  
208-240-480/60/3  
CF3500A-W  
* Optional motor contactor supplied.  
Part No. 550-142-026/0508  
 
Burner Specification & Data sheet — Beckett Oil Burners  
(continued)  
Burner specifications and settings  
Table 2  
Burner data, continued  
Boiler  
Model  
Number  
Oil Nozzle(s)  
Operating Oil  
Pressures  
PSIG  
Fuel Unit  
Burner-Motor Driven  
3450 RPM  
Preferred nozzles  
Alternate nozzles  
Qty.  
Size  
GPH  
Brand  
Type Spray Qty.  
Angle  
Size  
GPH  
Brand  
Type Spray  
Angle  
Low High  
Type  
(Suntec)  
Nozzle Gearset  
Capacity Capacity  
Fire  
Fire  
GPH  
GPH  
488R  
488  
1
1
1
1
1
2
2
2
2
2
2
2
2
4.00  
4.00  
5.50  
7.00  
8.50  
5.00  
5.50  
5.50  
6.00  
6.50  
7.00  
7.50  
8.50  
B
B
P
B
B
B
P
P
B
B
B
B
B
70°  
70°  
60°  
60°  
60°  
60°  
60°  
60°  
70°  
70°  
45°  
45°  
60°  
None  
None  
150  
150  
150  
150  
150  
300  
290  
300  
300  
300  
300  
300  
300  
290  
300  
300  
300  
300  
300  
290  
300  
300  
300  
300  
300  
300  
B2TA-8851  
B2TA-8851  
16  
33  
Delavan  
Delavan  
Hago  
16  
16  
23  
30  
30  
30  
30  
30  
30  
30  
30  
30  
33  
33  
39  
46  
46  
46  
46  
46  
46  
46  
46  
46  
588  
1
5.50  
B
60°  
B2TA-8851  
Delavan  
None  
688  
B2GA-8852  
Delavan  
Delavan  
Delavan  
Hago  
788  
1
2
2
2
2
2
2
2
2
8.50  
5.00  
5.50  
5.50  
6.00  
6.50  
7.00  
7.50  
8.50  
P
PLP  
B
60°  
45°  
60°  
60°  
60°  
60°  
60°  
45°  
45°  
J4PA-C1050G  
J4PA-C1050G  
J4PA-C1050G  
J4PA-C1050G  
J4PA-C1050G  
J4PA-C1050G  
J4PA-C1050G  
J4PA-C1050G  
J4PA-C1050G  
Hago  
888  
Monarch  
Delavan  
Delavan  
Delavan  
Delavan  
Delavan  
Monarch  
Hago  
988R  
988  
B
Hago  
1088R  
1088  
1188  
1288  
1388  
B
Delavan  
Delavan  
Delavan  
Delavan  
Delavan  
B
B
PLP  
P
Notes for Table 1 and Table 2  
1. Burner capacities listed for elevations up to 2,000 feet. For  
higher elevations, consult local Weil-McLain distributor/  
agent or sales office.  
cadmium cell for flame detector to monitor oil  
burner flame, also furnishes intermittent ignition.  
b) RM7840M flame safeguard control monitors the oil  
burner flame, provides pre-purge and post-purge  
programming. Timed low fire start is provided by  
means of timing built into control. Control is used  
with UL on-off (low fire start) systems. Photocell  
electronic flame detector is standard with ultraviolet  
and infrared detector available.  
2. Light oil ratings based on No. 2 fuel oil with heating value of  
140,000 Btu per gallon.  
3. Boiler-burner unit to be adjusted to achieve +0.10 inches  
W.C. pressure at the flue collar, resulting in positive pressure  
in firebox as listed.  
4. Control Systems:  
LHO: On-off operation, low fire start, high fire run.  
Two-position air, two-position oil.  
7. Burners will be completely assembled and wired.  
LHL: Low-high-low-off firing conditions. Two-  
position air, two-position oil.  
8. Burners listed by Underwriters Laboratories, Inc., Underwrit-  
ers Laboratory Canada, State of Connecticut, Fire Marshal  
state of Massachusetts, city of New York MEA, and others.  
5. 120/60/1 control circuit is used for all burners.  
6. Combustion Controls:  
9. Settings shown are for initial set-up. Final settings should be  
determined after combustion readings.  
a) Beckett 7505P1515/CC combustion control uses  
Part No. 550-142-026/0508  
3
 
Weil-McLain 88 Water and Steam Boilers — Series 2 — For Gas, Light Oil, & Gas/Light Oil-Fired Burners  
Burner dimensions  
Dimensions in Inches  
Burner  
Model  
Air Tube  
Combination  
A
B
C
D
E
F
G
H
I
Number  
Overall  
Length  
Insertion  
Depth  
Maximum  
Tube O.D.  
Burner  
Length  
(External To  
Appliance)  
Overall  
Height  
Bolt  
Circle  
Centerline Centerline  
Square  
Flange  
Width &  
Height  
To Pump  
To Motor  
CF1400-W  
CF2300A-W  
CF2300A-W  
CF2500-W  
CF3500A-W  
CF66KD  
CF66KG  
CF66KS  
CF66KP  
CF80KM  
24.75  
25.25  
25.25  
26.25  
27.50  
4.00  
4.00  
4.00  
4.00  
4.50  
5.50  
6.50  
8.13  
6.50  
7.87  
20.63  
21.13  
21.13  
22.13  
23.38  
13.50  
15.60  
15.60  
17.70  
17.70  
10.25  
10.25  
10.25  
10.25  
10.25  
9.50  
10.40  
10.40  
12.70  
12.70  
9.82  
12.00  
12.00  
14.10  
14.10  
12.00  
12.00  
12.00  
12.00  
12.00  
4
Part No. 550-142-026/0508  
 

West Bend Fryer L 5486 User Manual
Westinghouse Microwave Oven WCM770B User Manual
Whirlpool Cooktop 4454653 User Manual
White Rodgers Thermostat 1C21 User Manual
Wilton Lathe 63199 User Manual
Xantrex Technology Portable Generator PV225S 480 P User Manual
Yamaha Blu ray Player BD A1040 User Manual
Yamaha Network Card DB SREV1 User Manual
Zanussi Oven ZOD580 User Manual
ZETA Music Systems Speaker System ZMC 200 User Manual