VALVE-REGULATED LEAD ACID BATTERIES: INDIVIDUAL DATA SHEET
For main and standby power supplies.
LC-R063R4P
Expected trickle life: 3-5 years at 25°C, Approx. 5 years at 20°C.
Dimensions (mm)
Terminal type: Faston 187
+
0.059
5.276 +
0.020
-
1.339 + 0.039 (34 +1)
1.5
(134+
)
-
-
0.5
-
0.398 (10.1)
0.398 (10.1)
5.12 (129.8)
1.319 (33.5)
5.236 (133)
Photo/Label for reference only.
Battery case resin: Standard (UL94HB) Color is black.
Specifications
Discharge characteristics 77°F (25°C) (Note)
Nominal Voltage
Rated Capacity (20 hour rate)
Length
6V
3.4Ah
7.2
6.9
6.6
6.3
6.0
5.7
5.4
5.1
5.276 inches (134.0 mm)
Width
1.339 inches (34.0 mm)
2.362 inches (60.0 mm)
Dimensions
Height
Total Height
Approx. mass
2.598 inches (66.0 mm)
1.37 lbs. (0.62 kg)
0.17A
0.34A
8 10
0.85A
4
4.8
4.5
4.2
3.9
1.7A
2
3.4A
Standard Terminals
and Resin
UL94HB Faston 187
LC-R063R4P
0
1
2
4
6
8 10
20
40 60
6
20
40
(Minute)
(Hour)
Duration of discharge
(Note)
Characteristics
Duration of discharge vs. Discharge current
20 hour rate (170mA)
3.4Ah
3Ah
2.7Ah
2.1Ah
30
10 hour rate (300mA)
5 hour rate (540mA)
1 hour rate (2100mA)
Capacity (note)
77˚F (25˚C)
20
15
1.5 hour rate discharge
Cut-off voltage 5.25 V
Fully charged battery
77˚F (25˚C)
10
1.5A
104˚F (40˚C)
Approx. 30mΩ
Internal Resistance
5
4
Temperature
dependency
of capacity
102%
100%
85%
104˚F (40˚C)
77˚F (25˚C)
32˚F (0˚C)
77˚F (25˚C)
3
2
1.5
(20 hour rate)
65%
5˚F (-15˚C)
5˚F (-15˚C)
32˚F (0˚C)
Residual capacity
after standing 3 months
Residual capacity
after standing 6 months
Residual capacity
after standing 12 months
1
50
40
91%
82%
64%
Self discharge
77˚F (25˚C)
30
20
Cycle use
initial current
1.36 A or smaller
10
(Repeating
use)
Charge
Method
(Constant
Voltage)
7.25V to 7.45V
(per 6V cell 25˚C)
Control voltage
initial current
5
3
0.51 A or smaller
30
50
100
300 500
1
3
5
10
Trickle use
6.8V to 6.9V
(per 6V cell 25˚C)
Control voltage
(mA)
Discharge current
(A)
(Note) The above characteristics data are average values obtained
within three charge/discharge. Cycles not the minimum values.
VRLA BATTERIES
AUGUST 2005
This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to
modification without notice. Contact Panasonic for the latest information.
|