GE Telephone Accessories GE Security User Manual

GE Security  
Installation/Operation Instructions  
Warranty Information  
TR3010  
TT3010  
TR3010-R3  
TR3020WDM  
TR3020WDM-R3  
TR3030  
TT3010-R3  
TT3020WDM  
TT3020WDM-R3  
TT3030  
TR3030-R3  
TR3030WDM  
TR3030WDM-R3  
TT3030-R3  
TT3030WDM  
TT3030WDM-R3  
Add “-T” for Talkaphone Compatible Module  
888-999-9IFS  
 
TT/TR3000  
A
B
C
D
A
B
C
D
Link Status  
Off-Hook  
Ring Detect  
Power  
LED illuminates  
NOTE: All units set to USA/Canada standard.  
WORLD STANDARD JUMPER SETTINGS  
TT  
JUMPER SETTING  
J6  
J7  
STANDARD  
J7 J6  
ON ON USA/CANADA  
OFF ON UK*  
ON OFF AUSTRALIA  
OFF OFF JAPAN  
TR  
J6 J7  
* UK includes the following countries:  
Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland,  
Ireland, Italy, Luxembourg, Netherlands, Portugal, Spain, Sweden, Switzerland.  
 
FCC Compliance  
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two  
conditions: (1) This device may not cause harmful interference, and (2) this device must accept  
any interference received, including interference that may cause undesirable operation.  
Changes or modifications not expressly approved by International Fiber Systems, Inc. could void  
the user’s authority to operate the equipment.  
NOTE: This equipment has been tested and found to comply with the limits for a Class A  
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide  
reasonable protection against harmful interference when the equipment is operated in a  
commercial environment. This equipment generates, uses and can radiate radio frequency  
energy and, if not installed and used in accordance with the instruction manual, may  
cause harmful interference to radio communications. Operation of this equipment in a  
residential area is likely to cause harmful interference in which case the user will be  
required to correct the interference at his own expense.  
Complies with FDA Performance Standard for Laser Products  
Title 21  
Code of Federal Regulations  
Subchapter J  
CLASS 1 LASER PRODUCT  
(For purposes of IEC 60825-1)  
Comprehensive  
Lifetime Warranty  
(i) by repairing any defective or damaged product or parts of the  
products, or (ii) by making available any necessary repaired or  
replacement products or parts thereof. Any repaired or replacement  
part or product shall be warranted for the remaining period of the  
original Warranty Period. Seller shall pay, or credit Buyer for, the  
cost of freight for all return shipments of products or parts to  
Buyer. Where a failure cannot be corrected by Seller's reasonable  
efforts, the parties will negotiate an equitable adjustment in price.  
(a) Seller warrants to the original End User that products and any  
services furnished hereunder will be free from defects in material  
and workmanship as of the date of delivery, and will conform to  
Seller’s published technical specifications. The foregoing shall  
apply only to failures to meet said warranties which appear within  
that period of time during which the Products are installed in their  
original installation for the original End User and operator of such  
Products; provided, however, that in the event of product discontin-  
uance, warranty support is limited to five (5) years from the  
announcement of discontinuance. Notwithstanding the preceding  
sentence, the duration of the warranty period for products not  
manufactured by Seller (e.g., fiber optic cabling, test equipment,  
power supplies or batteries) shall be the warranty period offered by  
the original manufacturer, if any.  
(d) The preceding paragraph sets forth the exclusive remedies for  
claims based on defect in or failure of products or services,  
whether the claim is in contract, indemnity, warranty, tort  
(including Seller's negligence), strict liability or otherwise and  
however instituted. Upon the expiration of the warranty period,  
all such liability shall terminate and BUYER shall have a reason-  
able time, within thirty days after the warranty period, to give  
written notice of any defects which appeared during the warranty  
period. The foregoing warranties are exclusive and in lieu of all  
other warranties, whether written, oral, implied or statutory.  
NO IMPLIED OR STATUTORY WARRANTY OF  
(b) The conditions of any tests shall be mutually agreed upon and  
Seller shall be notified of, and may be represented at, all tests that  
may be made. The warranties and remedies set forth herein are  
conditioned upon (a) proper storage, installation, use and mainte-  
nance, and conformance with any applicable recommendations of  
Seller and (b) Buyer promptly notifying Seller of any defects and,  
if required, promptly making the product available for correction.  
MERCHANTABILITY OR FITNESS FOR PARTICULAR  
PURPOSE SHALL APPLY. Seller does not warrant any  
products or services of others which BUYER has designated.  
(c) If any product or service fails to meet the foregoing warranties,  
Seller shall thereupon correct any such failure either at its option,  
DESIGN CENTER (888) 999-9IFS or (203) 426-1180  
Fax: (203) 426-3326 [email protected]  
Europe, Middle East, Africa Tel: +44 (0) 1732 522 777  
Asia Pacific Tel: +65 6235 2661 Latin America (512) 477-8787  
 
FCC Part 68 Registration  
Customer Information  
This equipment complies with Part 68 of the FCC rules and the requirements adopted by the  
ACTA. On the bottom of this equipment is a label that contains, among other information, a  
product identifier in the format US: FIBOT01BTT3000.. If requested, this number must be  
provided to the telephone company.  
This product uses USOC jacks: RJ11C  
A plug and jack used to connect this equipment to the premises wiring and telephone network  
must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA. A  
compliant telephone cord and modular plug is provided with this product. It is designed to be  
connected to a compatible modular jack that is also compliant.  
The REN is used to determine the number of devices that may be connected to a telephone line.  
Excessive RENs on a telephone line may result in the devices not ringing in response to an  
incoming call. In most but not all areas, the sum of RENs should not exceed five (5.0). To be  
certain of the number of devices that may be connected to a line, as determined by the total  
RENs, contact the local telephone company. For products approved after July 23, 2001, the REN  
for this product is part of the product identifier that has the format US: FIBOT01BTT3000.. The  
digits represented by ## are the REN without a decimal point (e.g., 03 is a REN of 0.3).  
If this equipment, TT3000 or TR3000, causes harm to the telephone network, the telephone  
company will notify you in advance that temporary discontinuance of service may be required.  
But if advance notice is not practical, the telephone company will notify the customer as soon  
as possible. Also, you will be advised of your right to file a complaint with the FCC if you  
believe it is necessary.  
The telephone company may make changes in its facilities, equipment, operations or procedures  
that could affect the operation of the equipment. If this happens the telephone company will  
provide advance notice in order for you to make necessary modifications to maintain  
uninterrupted service.  
If trouble is experienced with this equipment TT3000 or TR3000, for repair or warranty informa-  
tion, please contact International Fiber Systems by calling 203-426-1180. If the equipment is  
causing harm to the telephone network, the telephone company may request that you disconnect  
the equipment until the problem is resolved.  
In the case of repairs to be done, repairs may only be performed by IFS trained personnel.  
This equipment is not intended to be used on party lines. Connection to party line service is sub-  
ject to state tariffs. Contact the state public utility commission, public service commission or  
corporation commission for information.  
If your home has specially wired alarm equipment connected to the telephone line, ensure the  
installation of this TT3000 or TR3000 does not disable your alarm equipment. If you have  
questions about what will disable alarm equipment, consult your telephone company or a  
qualified installer.  
DESIGN CENTER (888) 999-9IFS or (203) 426-1180  
Fax: (203) 426-3326 [email protected]  
Europe, Middle East, Africa Tel: +44 (0) 1732 522 777  
Asia Pacific Tel: +65 6235 2661 Latin America (512) 477-8787  
 
PROPER MOUNTING METHOD  
FOR THE TT/TR3000  
1) Locate unit on solid flat horizontal or vertical surface.  
2) Position unit no closer than 24 inches from any power source or machinery.  
3) Securely mount unit using (4) four mounting screws (not provided).  
4) Select the correct voltage requirements for your application, +12VDC or 12VAC.  
+12VDC attach black w/white stripe wire to pin 1 and black stripe to pin 2 (GND).  
For 12VAC connect brown to pin 1, green to pin 2 and blue to pin 3 from adapter.  
5) Plug power brick into approved 120v AC outlet.  
6) Check power LED to insure device is properly powered, LED will illuminate green.  
 
Product Disassembly Instructions for WEEE  
Per European Directive 2002/95/EC Waste Electrical and  
Electronic Equipment  
Required Tools:  
One number 2 Phillips (crosstip) screwdriver.  
One number 2 flat screwdriver.  
For the enclosed box version:  
1. Locate and remove box cover securement screws. Usually, but not limited to, at least  
4 screws.  
2. Lift off box top cover.  
3. Locate and remove securement screws for printed circuit board.  
4. If there are multiple boards to the assembly, continue removing securement screws  
until none are left.  
5. Lift off printed circuit board.  
6. Disassembly of box version of product is complete.  
For rack version:  
1. Locate and remove securement screws for printed circuit board. Usually, but not  
limited to, at least 4 screws.  
2. If there are multiple boards to the assembly, continue removing securement screws  
until none are left.  
3. Lift off printed circuit board(s).  
4. Disassembly of rack card version of product is complete.  
 

EdgeStar Dishwasher DWP40W User Manual
Excalibur electronic Home Safety Product H631 User Manual
Extron electronic Network Card 70 110 04 User Manual
Extron electronic Stereo Amplifier DVI DL 201 RX User Manual
Fisher Price Baby Toy 77029 User Manual
Fujitsu Flat Panel Television PDS4211W H User Manual
GE Carpet Cleaner 71722 User Manual
GE Microwave Oven PK91627 User Manual
Gemini CD Player CD 400X User Manual
GE Monogram Ventilation Hood ZXR8510 User Manual