ge.com
Safety Information . . . . . . . . 2, 3
Owner’s Manual and
Installation Instructions
Operating/Care and
Cleaning Instructions
Charcoal Filter . . . . . . . . . . . . . . .5
Grease Filter . . . . . . . . . . . . . . . .4
Hood Light . . . . . . . . . . . . . . . . .5
Hood Surfaces . . . . . . . . . . . . . . .5
Controls . . . . . . . . . . . . . . . . . . . .4
JN327–Recirculation only
JV338*–Vent options only
JV347*–Vent & Recirculation
options
JV367*–Vent & Recirculation
options
RN328–Recirculation only
Installation Instructions . . .6–14
Consumer Support
Consumer Support . . .Back Cover
Warranty . . . . . . . . . . . . . . . . . . 15
*
Write the model and serial numbers here:
Model # __________________________
Serial # __________________________
You can find them on a label on the
back wall of the hood.
49-80389-1 04-06 JR
INSTRUCTIONS DE SÉCURITÉ IMPORTANTES.
LISEZ TOUTES LES INSTRUCTIONS AVANT D’UTILISER.
PRÉCAUTIONS EN MATIÈRE DE SÉCURITÉ
AVERTISSEMENT –
POUR RÉDUIRE LE
AVERTISSEMENT –
RÉDUISEZ LE
RISQUE D’INCENDIE, DE SECOUSSE ÉLECTRIQUE OU DE
BLESSURE CORPORELLE, OBSERVEZ LES PRÉCAUTIONS
SUIVANTES :
RISQUE D’UN FEU DE GRAISSE SUR LA SURFACE DE
CUISSON DU FOUR :
A. Ne laissez jamais sans surveillance les unités de
cuisson de surface à une température élevée. Le
bouillonnement occasionne des débordements
fumants et graisseux qui peuvent prendre feu.
Chauffez à feu doux les substances huileuses,
avec un réglage bas ou moyen.
B. ALLUMEZ toujours la hotte en cas de cuisson à
feu élevé ou lorsque vous faites flamber des aliments
(par exemple, crêpes Suzette, cerises jubilées, bœuf
au poivre flambé).
C. Nettoyez les mécanismes de ventilation
fréquemment. Il ne faut pas permettre une
accumulation de graisse sur le ventilateur ou
sur le filtre.
D. Utilisez une casserole de bonne taille. Utilisez
toujours un ustensile de cuisine qui convienne au
diamètre de l’élément de cuisson.
A. N’utilisez cet appareil que de la manière prévue
par le fabricant. Si vous avez des questions, appelez
le fabricant.
B. Avant de réparer ou de nettoyer votre appareil,
débranchez le courant au niveau du panneau
de service et verrouillez les mécanismes de
débranchement de service pour éviter tout
branchement accidentel au courant. Si vous ne
pouvez pas verrouiller les mécanismes de
débranchement de service, attachez soigneusement
un avertissement bien visible, comme une étiquette,
au panneau de service.
C. N’utilisez jamais cet appareil avec un mécanisme
de réglage de la vitesse à semi-conducteurs.
D. Si vous utilisez l’ensemble de cordon de
raccordement, utilise seulement avec l’ensemble de
cordon de raccordement pour hotte JXHC1. Suite à
un examen technique, l’article JXHC1 s’est avéré
compatible avec ce modèle de hotte.
AVERTISSEMENT –
POUR RÉDUIRE LE
RISQUE D’INCENDIE, DE SECOUSSE ÉLECTRIQUE OU DE
BLESSURE CORPORELLE, OBSERVEZ LES PRÉCAUTIONS
SUIVANTES :
E. Cet appareil doit être bien mis à la terre.
ATTENTION –
UNIQUEMENT À USAGE DE
A. Vous devez faire exécuter tous les travaux
d’installation et de câblage électrique par une
personne qualifiée, conformément à tous les codes
et les normes en vigueur, en particulier ceux de
construction relatifs aux incendies.
B. Vous devez assez d’air pour avoir une bonne
combustion et permettre l’évacuation des gaz par le
conduit de cheminée du matériel de combustion du
carburant, afin d’éviter tout retour d’air. Suivez les
directives du fabricant de matériel de combustion et
les normes de sécurité comme celles publiées par la
National Fire Protection Association (NFPA),
l’American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), ainsi que les
modalités des codes locaux.
VENTILATION GÉNÉRALE. N’UTILISEZ JAMAIS POUR
L’ÉCHAPPEMENT DE MATIÈRES ET DE VAPEURS
EXPLOSIVES.
AVERTISSEMENT –
POUR RÉDUIRE LE
RISQUE DE BLESSURE CORPORELLE SI DE LA GRAISSE
PREND FEU SUR LA SURFACE DE CUISSON DU FOUR,
SUIVEZ LES INSTRUCTIONS SUIVANTES* :
A. ÉTOUFFEZ LES FLAMMES avec un couvercle qui
convient, une tôle à biscuits ou un plateau en métal,
puis éteignez le brûleur. FAITES BIEN ATTENTION
DE NE PAS VOUS BRÛLER. Si les flammes ne
s’éteignent pas immédiatement, SORTEZ ET
APPELEZ LES POMPIERS.
C. Si vous faites un trou ou une ouverture dans un mur
ou un plafond, n’endommagez pas les fils électriques
et les autres installations cachées de service public.
B. NE DÉPLACEZ JAMAIS UNE CASSEROLLE QUI
FLAMBE – Vous pouvez vous brûler.
C. N’UTILISEZ JAMAIS D’EAU, en particulier de
serviette ou de chiffon mouillé – il se produira une
explosion violente de vapeur brûlante.
D. Vous devez toujours alimenter les ventilateurs dans
les conduits en air en provenance de l’extérieur.
D. N’UTILISEZ UN EXTINCTEUR que si :
AVERTISSEMENT –
POUR RÉDUIRE
1. Vous avez un extincteur de classe ABC et vous
LE RISQUE D’INCENDIE, N’UTILISEZ QUE DES CONDUITS
EN MÉTAL.
savez comment l’utiliser;
2. Le feu est réduit et confiné à l’endroit où il a
I
N’essayez jamais de remplacer ou de réparer un
élément de votre hotte si le présent manuel ne le
recommande pas expressément. Tout autre entretien
doit être effectué par un technicien qualifié.
commencé;
3. Vous avez déjà appelé les pompiers;
4. Vous combattez les flammes en tournant le dos à
une sortie.
* Basé sur l’ouvrage intitulé «Kitchen Fire Safety Tips»
publié par la NFPA.
LISEZ ET SUIVEZ ATTENTIVEMENT CES INSTRUCTIONS.
LISEZ ET CONSERVEZ CES INSTRUCTIONS
3
Using the hood controls.
Throughout this manual, features and appearance may vary from your model.
Switch Pad Controls (on some models)
Control Knobs (on some models)
ON
HI
OFF
LO
OFF
OFF
ON
LO
HI
OFF
MED
NITE
FAN Control
Turn to HI, MED or LO as needed.
LIGHT Control
Press the pad at the top to turn the light ON.
Continuous use of the fan system while cooking
helps keep the kitchen comfortable and less
humid. It also reduces cooking odors and soiling
moisture that create a frequent need for cleaning.
FAN Control
Press the pad at the top to turn the fan on HI and
at the bottom to turn it on LO. The center position
is OFF.
Continuous use of the fan system while cooking
helps keep the kitchen comfortable and less
humid. It also reduces cooking odors and soiling
moisture that create a frequent need for cleaning.
LIGHT Control
Turn to ON while cooking or to NITE for use as a
night light.
Care and cleaning of the vent hood.
Be sure electrical power is off and all surfaces are cool before cleaning or servicing any part of the
vent hood.
Reusable Metal Grease Filter—Ducted Installations Only
The efficiency of your hood
depends on a clean filter.
Frequency of cleaning depends on
hood use and the type of cooking
you do. However, the grease filter
should be cleaned at least once a
month.
To clean:
Soak and then agitate it in a hot
water and detergent solution.
Light brushing can be used to
remove embedded dirt. Rinse,
shake and let it dry before
replacing.
Grease filter
To remove:
NEVER OPERATE THE HOOD
Pull down on the center of the
front edge of the filter. The filter
will then slip out of the retaining
tabs on the back.
WITHOUT THE FILTER IN PLACE.
With careful handling, the metal
filter will last for years. If a new
replacement filter becomes
necessary, order the part from
your dealer. Order genuine GE
part number WB02X8391.
To replace:
Slip the back edge of the filter
into the retaining tabs and push
the front edge up until it snaps
into place.
4
Charcoal Filter—Recirculating Installations Only
The charcoal filter cannot be cleaned.
It must be replaced. Order filter no.
WB02X10700. Replacement filters
can be ordered from your GE supplier.
If the hood is not vented to the
outside, the air will be recirculated
through a disposable charcoal filter
To remove:
Pull down on the center of the front
edge of the filter. The filter will then
slip out of the retaining tabs on the
back.
To replace:
Slip the back edge of the filter into
Replaceable charcoal filter
NOTE: DO NOT rinse, or put charcoal filters in
an automatic dishwasher.
that helps remove smoke and odors. the retaining tabs and push the
front edge up until it snaps into
place.
The charcoal filter should be
replaced after 6 to 12 months
(depending on hood usage).
Stainless Steel Surfaces (on some models)
To inquire about purchasing
stainless steel appliance cleaner or
polish, or to find the location of a
dealer nearest you, please call our
toll-free number:
Do not use a steel-wool pad; it will
scratch the surface.
To clean the stainless steel
surface, use warm sudsy water or
a stainless steel cleaner or polish.
Always wipe the surface in the
direction of the grain. Follow the
cleaner instructions for cleaning
the stainless steel surface.
National Parts Center
ge.com
800.626.2002
Painted Surfaces (on some models)
Do not use steel-wool pads or other
abrasive cleaners. They will scratch
the surface.
NOTE: When cleaning, take care not
to come in contact with filters and
other non-enameled surfaces.
Clean grease-laden surfaces of the
hood frequently. To clean the hood
surface, use a hot, damp cloth with a do not touch the light bulb with moist
CAUTION: When cleaning the
hood surfaces, be certain that you
mild detergent suitable for painted
surfaces. About one tablespoon of
ammonia may be added to the
water. Use a clean, hot, damp
cloth to remove soap. Dry with
a dry, clean cloth.
hands or cloth. A warm or hot light
bulb may break if touched with a moist
surface. Always let the light bulb cool
completely before cleaning around it.
Hood Light
CAUTION: Let the light bulb cool
completely before removing. A
warm or hot bulb may break if
touched with a moist cloth or hand.
To replace the light cover:
• Insert the prong located at the
end of the cover into the top
opening.
Remove the bulb and replace with
an ordinary screw-base light bulb,
not more than 60 watts.
• Gently push the cover up and
press the sides to fit the side
prongs into the side openings.
Light cover
To remove the light cover
(on some models):
• Release and the cover will lock
in position.
• Press the sides with two fingers
until the side prongs are released.
• Lift the light cover and slide it
toward you in one motion.
5
Installation
Instructions
Range Hood
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com
DUCTWORK REQUIREMENTS
NOTE: Read the ductwork sections only if you do not
have existing ductwork. If you have existing ductwork,
skip to the “Damage” section and proceed.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
•
IMPORTANT –
Save these
instructions for local inspector’s use.
The venting system must exhaust to the outside.
•
IMPORTANT –
Observe all
This hood can be vented vertically through upper
cabinets or horizontally through an outside wall.
Ductwork is not included.
governing codes and ordinances.
• Note to Installer – Be sure to leave these
instructions with the Consumer.
Exhaust connection:
The hood exhaust has been designed to mate with
standard 31⁄4″ x 10″ rectangular ducting or 7″ diameter
round ducting.
If a 6″ round duct is required, a rectangular-to-round
transition adaptor must be used*. Do not use less than
a 6″ diameter duct.
• Note to Consumer – Keep these instructions
for future reference.
• Skill level – Installation of this appliance requires
basic mechanical and electrical skills.
• Completion time – 30 minutes–3 hours
• Proper installation is the responsibility of the
installer.
Maximum duct length:
• Product failure due to improper installation is not
For satisfactory air movement, the total duct length
of a 31⁄4″ x 10″ rectangular, 6″ or 7″ diameter round
duct should not exceed 65 equivalent feet. See the
WORKSHEET–CALCULATE TOTAL EQUIVALENT
DUCTWORK LENGTH section.
covered under the Warranty.
FOR YOUR SAFETY:
NOTE: It is important that ducting be installed using
the most direct route and with as few elbows as possible.
This ensures clear venting of exhaust and helps prevent
blockages. Also, make sure dampers swing freely and
nothing is blocking the ducts.
WARNING –
Before beginning the
installation, switch power off at service panel and lock
the service disconnecting means to prevent power
from being switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag,
to the service panel.
Elbows, transitions, wall and roofcaps, etc.,
present additional resistance to airflow and are
equivalent to a section of straight duct longer than their
actual physical size. When calculating the total duct
length, add the equivalent lengths of all transitions and
adaptors plus the length of all straight duct sections. The
charts on the following pages show you how to calculate
total equivalent ductwork length using the approximate
feet of equivalent length of some typical ducts.
OPTIONAL POWER CORD KIT JXHC1
An optional Power Cord Connection Kit, model
JXHC1, is available at extra cost from your GE
supplier for installation using a standard 3-prong,
grounded wall outlet. Follow the Installation
Instructions packed with the kit to connect
the power cord to the range hood.
* IMPORTANT: If a rectangular-to-
round transition adaptor is used, the
bottom corners of the damper will
have to be cut to fit, using the tin
snips, in order to allow free
movement of the damper.
Equivalent lengths of duct pieces
are based on actual tests and reflect
requirements for good venting
performance with any hood.
6
Installation Instructions
WORKSHEET—CALCULATE TOTAL EQUIVALENT DUCTWORK LENGTH
DUCT
PIECES
EQUIVALENT NUMBER
DUCT
PIECES
EQUIVALENT NUMBER
LENGTH x USED
LENGTH
x USED
= TOTAL
= TOTAL
31⁄4″x 10″
Rect.,
straight
1 Ft.
x (
)
=
Ft.
6″Round 24 Ft.
x (
x (
)
)
=
=
Ft.
wall cap
with
(18 ft. w/o
damper)
Ft.
Ft.
Ft.
damper
7″ Round,
straight
1 Ft.
1 Ft.
14 Ft.
x (
x (
x (
)
)
)
=
=
=
Ft.
Ft.
Ft.
6″ Round 33 Ft.
roof cap
x (
x (
)
)
=
=
6″ Round,
straight
6″ Round 2 Ft.
to
31⁄4″x 10″
Rect. 90°
elbow
31⁄4″x 10″
rect.
transition
31⁄4″x 10″
Rect. 45°
elbow
8 Ft.
x (
x (
)
)
=
=
Ft.
Ft.
6″ Round 4 Ft.
to
x (
)
=
Ft.
31⁄4″x 10″
rect.
31⁄4″x 10″
Rect. 90°
flat elbow
33 Ft.
transition
90° elbow
7″ Round, 14 Ft.
x (
x (
)
)
=
=
Ft.
Ft.
31⁄4″x 10″
Rect.
wall cap
with
24 Ft.
(18 ft. w/o
damper)
x (
x (
)
)
=
=
Ft.
Ft.
90° elbow
7″ Round, 9 Ft.
45° elbow
damper
7″ Round 28 Ft.
x (
x (
)
)
=
=
Ft.
Ft.
31⁄4″x 10″
Rect. to
6″ round
transition
2 Ft.
4 Ft.
x (
)
)
=
=
Ft.
Ft.
wall cap
with
(21 ft. w/o
damper)
damper
7″ Round 39 Ft.
roof cap
x (
x (
)
)
=
=
Ft.
Ft.
31⁄4″x 10″
Rect. to
6″ round
transition
90° elbow
x (
7″ Round 1 Ft.
to
31⁄4″x 10″
rect.
6″ Round,
90° elbow
12 Ft.
7 Ft.
x (
x (
)
)
=
=
Ft.
Ft.
transition
7″ Round 5 Ft.
to
x (
)
=
Ft.
6″ Round,
45° elbow
31⁄4″x 10″
rect.
transition,
90° elbow
Subtotal column 1
=
Ft.
Subtotal column 2
Subtotal column 1
Total ductwork
=
=
=
Ft.
Ft.
Ft.
MAXIMUM DUCT LENGTH: For satisfactory air
movement, the total duct length of a 31⁄4″ x 10″
rectangular, 6″ or 7″ diameter round duct should
not exceed 65 equivalent feet.
7
Installation Instructions
DAMAGE – SHIPMENT/INSTALLATION
TOOLS YOU WILL NEED
• If the unit is damaged in shipment, return the unit to the
store in which it was bought for repair or replacement.
• If the unit is damaged by the customer, repair or
Flat blade and Phillips
screwdrivers
Pencil
replacement is the responsibility of the customer.
Duct tape
• If the unit is damaged by the installer (if other than
the customer), repair or replacement must be made
by arrangement between customer and installer.
Electric drill
Metal snips
Saw (saber or keyhole)
(in some
applications)
Bottom edge of
MOUNTING SPACE
cabinet needs
to be 30″ or
more from
the cooking
surface
Tape measure
Level
Wire stripper
Pliers
1/4″ pivoting
hex socket
30″
min.
Caulking
Flashlight
1/4″ Nutdriver
PARTS INCLUDED
66″ or more
from the floor
to the top of
the hood
PART
QUANTITY
Grease Filter only (JV338)
1
Charcoal Filter only
(JN327 and RN328)
1
2
4
1
Grease Filter and Charcoal
Filter (JV347 and JV367)
Mounting Screws
(8 - 18 x 3/4 Phillips pan head)
Exhaust Adaptor
(for 31⁄4″ x 10″ rect. venting)
NOTES:
Exhaust Adaptor Screw
(8 - 18 x 3/8 Phillips pan head
or hex head)
1
• This range hood is for installation over ranges or
cooktops up to 36″ wide.
• If you are going to vent your range hood to the
outside, see the “Ducting Requirements” section
for exhaust duct preparation.
8
Installation Instructions
1
CHOOSE VENT OPTION
Determine the vent option that your installation will
require and that is available for your model from the
below choices.
IMPORTANT: If the hood is to be installed in a
recirculating, non-vented ductless manner, do not
knock out any vent openings in the hood. Only an
electrical access hole will be knocked out of the hood.
Outside top exhaust
Outside rear exhaust
A
C
(Vertical duct–31⁄4″ x 10″ Rectangular)
(Horizontal duct–31⁄4″ x 10″
Rectangular)
JV338
JV338
JV347
JV367
JV347
JV367
Recirculating
(non-vented/ductless)
Outside top exhaust
(Vertical duct–7″ Round)
B
D
JV338
JN327
RN328
JV347
JV367
JV347
JV367
9
Installation Instructions
5
2
REMOVE WIRING COVER
REMOVE EXHAUST ADAPTOR
If exhausting/venting using the 31⁄4″ x 10″ rectangular
duct—optional for JV338, JV347 and JV367 models
only:
Remove the exhaust adaptor from the inside of the
hood. Set it aside along with its mounting screws.
Remove the wiring cover from inside the hood.
Set the cover and its mounting screw aside.
Wiring
cover
31⁄4″ x 10″
rectangular
exhaust
adaptor
and screws
6 REMOVE WIRING KNOCKOUT
Remove either the top or the back wiring knockout as
needed and install an approved strain relief clamp.
3
REMOVE FILTER
Remove the shipping tape holding the metal grease
filter in place. Pull down on the center of the front
edge of the filter. The filter will then slip out of the
retaining tabs on the back.
Top knockout Back knockout
Strain relief
Strain relief
clamp
clamp
Metal grease filter
7
REMOVE DUCT KNOCKOUT
If recirculating, non-vented ductless (JN327 and RN328,
and optional for JV347 and JV367 models only), skip to
Step 10 D and proceed.
4
REVERSE THE BAFFLE FOR
DUCTED INSTALLATIONS ONLY
(JV347 and JV367 models)
If the hood is to be recirculated, skip to the next step.
Remove the baffle from the top of the hood. Re-install
the baffle so the short side marked “VENTED” is
visible. The long side of the baffle should be inside
the hood.
Using a flat blade screwdriver, remove the appropriate
duct knockout from the top or back of the hood.
31⁄4″ x 10″ Rectangular
vertical discharge.
Remove top rectangular
duct knockout only.
7″ Round vertical
discharge. Remove circular
duct knockout only.
“VENTED” is visible
31⁄4″ x 10″ Rectangular
horizontal discharge. Remove
rear rectangular duct knockout only.
10
Installation Instructions
FOR 31⁄4″ X 10″ RECTANGULAR
DUCTED DISCHARGE
8
10
FOR RECESSED-BOTTOM
CABINETS ONLY
INSTALLATIONS ONLY:
Attach exhaust adaptor/damper over the appropriate
knockout opening (for vertical or horizontal,
depending on installation) with two exhaust adaptor
screws. Make sure damper pivot is nearest to top/back
edge of hood. Remove tape from damper flap.
Wood shims
(minimum thickness 3/8″)
Exhaust adaptor/damper
(vertical discharge position)
• If the cabinets have front, side or back trim, make
2 wood shims a minimum of 3/8″ thick and cut to
fit the width of the inner recessed cabinet bottom.
Attach them to the cabinet bottom recess on both
sides. See Step 11 for marking locations.
Tape
Up to 1″ side-to-
side adjustment
Pivot
(depending on
installation)
Top/back edge
Exhaust adaptor/damper
(horizontal discharge position)
NOTE: The exhaust adaptor/damper can be installed
up to 1 inch on either side of the hood center to
accommodate off-center ductwork. In extreme off-
center installations, one end of the duct connector may
need to be trimmed to clear the electrical cable clamp.
9
FOR 7″ ROUND VERTICAL
DUCTED DISCHARGE
INSTALLATIONS ONLY:
Bend up the duct alignment ears in preparation for
later attachment of the 7″ duct.
Attachment ear tabs
11
Installation Instructions
11
MARK HOLES
C. Outside rear exhaust
(Horizontal duct–31⁄4
• Use the diagram or the hood as a template and
mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.
Select the vent option that your installation will
require and proceed to that section:
″
x 10″ Rectangular)
A.Outside top exhaust
(Vertical duct–31⁄4
x 10 Rectangular)
• Use the diagram or the hood as a template and
mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.
″
″
Wood shims
(recessed-bottom cabinets only–shims must be a
minimum of 3/8″ thick and cut to fit the width
of the inner recessed cabinet bottom)
1⁄2″
Hood mounting screws (4)
Cabinet front
11⁄4″
133⁄4″ (30″ hood)
163⁄4″ (36″ hood)
Cabinet front
133⁄4
163⁄4
″
″
(30
(36
″
″
hood)
hood)
Horizontal duct
access hole
33⁄4″
Cabinet
bottom
73⁄4″
Cabinet Bottom
51⁄4″ 51⁄4″
51⁄4″
51⁄4″
73⁄4″
133⁄4″ (30″ hood)
133⁄4″ (30″ hood)
163⁄4″ (36″ hood)
95⁄8″
13⁄8″
11⁄4″
163⁄4″ (36″ hood)
Vertical duct
33⁄4″
access hole
1⁄2″
Electrical access hole
(in wall)
Hood mounting screws (4)
Center line
Electrical access hole
(in cabinet bottom)
Wood shims
Center
line
(recessed-bottom cabinets
only–shims must be a
minimum of 3/8″ thick
and cut to fit the width
of the inner recessed
cabinet bottom)
D.Recirculating (non-vented ductless–
JN327 and RN328, and optional on
JV347 and JV367 models only)
• Use the hood as a template and mark the locations
on the cabinet for the electrical wiring and keyhole
screw slots.
• Since the hood is to be recirculated (not to be vented
outside), do not cut out any vent openings in the wall
or cabinet bottom.
B.Outside top exhaust (Vertical duct–7″ Round)
• Use the diagram or the hood as a template and
mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.
Hood mounting screws (4)
12
CUT HOLES
133⁄4″ (30″ hood)
163⁄4″ (36″ hood)
Cabinet front
133⁄4
163⁄4
″
″
(30
(36
″
″
hood)
Cut holes at marked locations for duct and electrical
wiring. For the vertical duct, cut out 3/4″ extra
toward the front of the cabinet so you can move the
duct freely when installing the hood. It may also ease
installation by cutting the hole 101⁄2″ instead of 10″.
hood
)
73⁄4″
Cabinet
bottom
8″ DIA.
95⁄8″
13⁄8″
11⁄4″
Access
HOLE
hole for 7″
53⁄4″
round duct
Electrical access
hole (in cabinet bottom)
Wood shims
Center
line
(recessed-bottom cabinets
only–shims must be a minimum
of 3/8″ thick and cut to fit the
width of the inner recessed
cabinet bottom)
13
RUN WIRES
Run the electrical wires through the wall or
cabinet according to National Electrical Code
and applicable local codes.
NOTE: DO NOT turn the power on until
installation is complete.
12
Installation Instructions
14
15
SCREW IN PARTWAY
17
SECURE HOOD
Drive a mounting screw (from the hardware packet)
partway into each center of the narrow neck of the
keyhole slots marked on the cabinet bottom.
Slide the hood back against the wall. Tighten
the mounting screws. Be sure the screw heads
are in the narrow neck of the keyhole slot.
OPTIONAL POWER CORD
KIT JXHC1
An optional Power Cord Connection Kit, model
JXHC1, is available at extra cost from your GE
supplier for installation using a standard 3-prong,
grounded wall outlet. Follow the Installation
Instructions packed with the kit to connect the
power cord to the range hood.
Mounting
screw (4)
Keyhole (4)
NOTE: DO NOT PUSH ON FAN BLADE. Pushing
on the blade may cause it to interfere with other
hood parts.
C
L
Cabinet
3-prong
18
CONNECT DUCTWORK TO
HOOD (Ducted installations only)
On 7″ round installations, attach the 7″ duct
with sheet metal screws through the holes in
the alignment ears.
wall outlet
(if using cord
connection)
73⁄4″
11⁄4″
13⁄4″ dia. clearance hole
for optional power
supply location
7″ round duct
NOTE: If using optional Power Cord Kit JXHC1,
feed the power cord through the hole in the top
cabinet while raising the hood. Loop any excess
length of cord and tie away with a suitable tape
or tie.
Attachment ear tabs
Use duct tape to make joints secure and air tight.
16
FEED IN WIRES
Lift the hood into position and feed the house
wiring through the wiring knockout.
Duct tape
13
Installation Instructions
19
23
INSTALL LIGHT BULB
REPLACE FILTER
NOTE: A light bulb is not shipped with the hood.
Obtain one locally. Purchase and install an ordinary
screw-base light bulb, not more than 60 watts.
Make sure fan blade turns freely and replace the
filter. NOTE: On model JV347, install the metal
grease filter if ducted or the charcoal filter if
recirculated.
20
21
FOLLOW ELECTRICAL CODE
Complete the electrical wiring according to
National Electrical Code and local codes.
NOTE: This hood must be permanently grounded.
Connect house wiring (120 VAC) to hood wiring.
Metal grease filter or charcoal filter
The installation is complete. Turn on power at
service panel, and test for proper operation.
TROUBLESHOOTING CHECKLIST
If the hood seems to be operating at high speed when
the control is not set on high, or if ventilation seems
inadequate, check the following:
❏ Knockouts not removed from hood.
❏ Damper blade not opening.
CONNECT WIRING
Connect house black to hood black wire, house
white to hood white wire and house ground under
green ground screw. Securely tighten the strain
relief clamp onto the house wiring.
❏ Reduced airflow because the duct is too small or
Green ground screw
the duct length is too long.
❏ The duct is blocked.
❏ Undersized or restrictive wall or roof cap.
If the hood seems to make excessive noise:
❏ Fan may be hitting the filter. Turn off the fan and
remove the filter. Bend the filter down slightly in the
center (into a dome shape) to allow fan clearance.
Reinstall and adjust as needed.
WARNING: IMPROPER CONNECTION OF
ALUMINUM HOUSE WIRING TO THESE
COPPER LEADS CAN RESULT IN A SERIOUS
PROBLEM. USE ONLY CONNECTORS
DESIGNED FOR JOINING COPPER TO
ALUMINUM AND FOLLOW THE
The fan does not work but the lights do:
❏ Switch power off at the service panel and lock the
service disconnecting means to prevent power from
being switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag,
to the service panel.
MANUFACTURER’S RECOMMENDED
PROCEDURE CLOSELY.
❏ Check the wiring connections. See the CONNECT
WIRING section in these Installation Instructions.
22
REPLACE WIRING COVER
Wiring cover
14
GE Range Hood Warranty.
All warranty service provided by our Factory Service Centers, or
Staple your receipt here.
Proof of the original purchase
date is needed to obtain service
under the warranty.
an authorized Customer Care® technician. To schedule service,
on-line, 24 hours a day, visit us at ge.com, or call 800.GE.CARES
(800.432.2737). Please have serial number and model number
available when calling for service.
For The Period Of: GE Will Replace:
One Year
From the date of the
original purchase
Any part of the range hood which fails due to a defect in materials or workmanship.
During this limited one-year warranty, GE will also provide, free of charge, all labor and
in-home service to replace the defective part.
What GE Will Not Cover:
IService trips to your home to teach you how to use
the product.
IDamage to the product caused by accident, fire, floods
or acts of God.
IImproper installation, delivery or maintenance.
IIncidental or consequential damage caused by possible
defects with this appliance.
IFailure of the product if it is abused, misused, or
used for other than the intended purpose or used
commercially.
IDamage caused after delivery.
IProduct not accessible to provide required service.
IReplacement of house fuses or resetting of circuit
breakers.
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in
this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness
for a particular purpose, are limited to one year or the shortest period allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home
use within the USA. If the product is located in an area where service by a GE Authorized Servicer is not available, you
may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service Location
for service. In Alaska, the warranty excludes the cost of shipping or service calls to your home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives
you specific legal rights, and you may also have other rights which vary from state to state. To know what your
legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.
Warrantor: General Electric Company. Louisville, KY 40225
15
Consumer Support.
GE Appliances Website
ge.com
ge.com
ge.com
Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day,
any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals,
order parts or even schedule service on-line.
Schedule Service
Expert GE repair service is only one step away from your door. Get on-line and schedule your service at
your convenience 24 hours any day of the year! Or call 800.GE.CARES (800.432.2737) during normal
business hours.
Real Life Design Studio
GE supports the Universal Design concept—products, services and environments that can be used by
people of all ages, sizes and capabilities. We recognize the need to design for a wide range of physical and
mental abilities and impairments. For details of GE’s Universal Design applications, including kitchen
design ideas for people with disabilities, check out our Website today. For the hearing impaired, please call
800.TDD.GEAC (800.833.4322).
Extended Warranties
ge.com
Purchase a GE extended warranty and learn about special discounts that are available while your warranty
is still in effect. You can purchase it on-line anytime, or call 800.626.2224 during normal business hours.
GE Consumer Home Services will still be there after your warranty expires.
Parts and Accessories
ge.com
Individuals qualified to service their own appliances can have parts or accessories sent directly to their
homes (VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or
by phone at 800.626.2002 during normal business hours.
Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally
should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause
unsafe operation.
Contact Us
ge.com
If you are not satisfied with the service you receive from GE, contact us on our Website with all the details
including your phone number, or write to: General Manager, Customer Relations
GE Appliances, Appliance Park
Louisville, KY 40225
Register Your Appliance
ge.com
Register your new appliance on-line—at your convenience! Timely product registration will allow for
enhanced communication and prompt service under the terms of your warranty, should the need arise.
You may also mail in the pre-printed registration card included in the packing material.
Printed in China
|