GE Monogram Refrigerator ZISS360NRSS User Manual

ZISS360NRSS – GE Monogram 36" Stainless Steel Built-In Side-by-Side  
Refrigerator with Automatic Icemaker and Water Filter  
The Installation Space  
36" Models 12"  
42" Models 18"  
48" Models 20"  
* Shipping height.  
The refrigerator  
35"  
Case Width  
25-3/4"  
can be adjusted to  
fit into a cutout that  
is 83-1/2” min. to  
84-1/2” max. height  
Note that the top  
case trim at the  
*Finished Width  
*84" From  
Floor to  
Top Frame  
6"  
*83-1/2"  
at  
Rear  
Electrical  
Area  
84-1/2" max  
83-1/2" min  
Finished  
front is 1/2” higher  
and will overlap  
5"  
upper cabinetry or  
soffit. Use leveling  
legs and wheels for  
a maximum 1" height  
adjustment.  
75" From Floor  
to Bottom  
of Electrical  
Area  
Opening  
24"  
36"  
27-3/4"  
including  
handle  
Frame to Frame  
5"  
5"  
Water Supply  
3-1/2"  
3-1/2"  
Water and Electrical Locations  
Product Clearances  
These refrigerators are equipped with a 2 position door stop.  
The factory set 130° door swing can be adjusted to 90° if  
clearance to adjacent cabinets or walls is restricted.  
The opening must be prepared with the electrical and water  
supply located as shown.  
15"  
13"  
The cutout depth must be 24".  
The refrigerator will project forward, slightly beyond adjacent  
cabinetry, depending on your installation.  
23-7/8"  
Behind  
Frame  
The cutout depth beneath a soffit:  
When installed beneath a soffit, the soffit cannot exceed the  
24" installation depth shown. The top case trim overlaps the  
bottom of the soffit.  
20-5/8  
4" Min.  
to Wall  
Frameless cabinets:  
The case trim overlaps cabinets at the top and sides.  
Therefore, frameless cabinets may require filler strips to  
prevent interference with cabinet door swing. The opening  
must allow for filler strips.  
Allow minimum clearances for freezer door and fresh food  
door for a full 130° door swing and to allow for pan removal.  
4" minimum clearance is required when door swing is adjusted  
to 90°. If the 90° door stop position is used, pan access is  
maintained, but pan removal is restricted.  
Additional Specifications  
• A 115 volt 60Hz., 15 or 20 amp power supply is required.  
An individual properly grounded branch circuit or circuit  
breaker is recommended. Install a properly grounded  
3-prong electrical receptacle recessed into the back wall.  
Electrical must be located on rear wall as shown.  
Installation Information: Before installing, consult  
installation instructions packed with product, or available  
at Monogram.com, for current dimensional data.  
As an EnErgy StAr®  
Note: GFI (ground fault interrupter) is not recommended.  
partner, gE has determined  
that this product meets the  
EnErgy StAr guidelines  
for energy efficiency.  
Listed by  
Underwriters  
Laboratories  
• Water line can enter the opening through the floor or back  
wall. The water line should be 1/4" O.D. copper tubing or  
GE SmartConnectkit between the cold water line and  
water connection location, long enough to extend to the  
front of the refrigerator. Installation of an easily accessible  
shut off valve in the water line is recommended.  
For answers to your Monogram, gE Profileor  
gE® appliance questions, visit our website at  
gEAppliances.com or call  
®
Specification Revised 3/08  
gE Answer Center® service, 800.626.2000.  
110104  
 

Fisher Paykel Cooktop OR61 User Manual
Fluke Thermometer PN 3612805 User Manual
Freedom9 Switch IP 100 User Manual
FujiFilm Camera Lens DV38X4SR4A SA1 User Manual
GE Convection Oven ZET857BBBB User Manual
GE Dishwasher 165D4700P389 49 55065 07 09 JR User Manual
Gefen Switch DVI Hub User Manual
Generac Plumbing Product 6294 User Manual
GE Network Router MM200 User Manual
GE Water System GXUL30Z User Manual