Fluke Thermometer PN 4060712 User Manual

62 MAX/62 MAX +  
Infrared Thermometer  
Users Manual  
PN 4060712  
April 2012  
© 2012 Fluke Corporation. All rights reserved. Printed in China.  
Specifications are subject to change without notice.  
All product names are trademarks of their respective companies.  
 
Table of Contents  
Title  
Page  
Introduction.................................................................................................................1  
How to Contact Fluke.................................................................................................1  
Safety Information ......................................................................................................2  
Maintenance...............................................................................................................5  
How to Change the Battery ....................................................................................5  
How to Clean the Product ......................................................................................5  
Specifications .............................................................................................................6  
Standards and Agency Approval................................................................................8  
The Product................................................................................................................9  
i
 
62 MAX/62 MAX +  
Users Manual  
Download from Www.Somanuals.cioim. All Manuals Search And Download.  
Introduction  
The Fluke 62 MAX and 62 MAX + Infrared Thermometers (the Product) can determine the  
surface temperature by measuring the amount of infrared energy radiated by the target’s  
surface. Note that the Japanese models indicate Celsius only.  
WWarning  
Read all safety information before you use the Product.  
How to Contact Fluke  
To contact Fluke, call one of the following telephone numbers:  
Technical Support USA: 1-800-44-FLUKE (1-800-443-5853)  
Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853)  
Canada: 1-800-36-FLUKE (1-800-363-5853)  
Europe: +31 402-675-200  
Japan: +81-03-6714-3114  
Singapore: +65-6799-5655  
Anywhere in the world: +1-425-446-5500  
1
 
 
62 MAX/62 MAX +  
Users Manual  
Or, visit Fluke's website at www.fluke.com.  
To register your product, visit http://register.fluke.com.  
To see, print, or download the latest manual supplement, visit  
Safety Information  
A Warning identifies conditions and procedures that are dangerous to the user. A Caution  
identifies conditions and procedures that can cause damage to the Product or the equipment  
under test.  
Table 1 tells you about symbols used on the Product and in this manual.  
*WWarning  
To prevent eye damage and personal injury:  
Read all safety Information before you use the Product.  
Do not use the Product if it operates incorrectly.  
Use the Product only as specified, or the protection supplied by the  
Product can be compromised.  
Before you use the Product, inspect the case. Do not use the Product if it  
appears damaged. Look for cracks or missing plastic.  
2
 
 
Infrared Thermometer  
Safety Information  
See emissivity information for actual temperatures. Reflective objects  
result in lower than actual temperature measurements. These objects  
pose a burn hazard.  
Do not look directly into the laser with optical tools (for example,  
binoculars, telescopes, microscopes). Optical tools can focus the laser  
and be dangerous to the eye.  
Do not look into the laser. Do not point laser directly at persons or  
animals or indirectly off reflective surfaces.  
Replace the batteries when the low battery indicator shows to prevent  
incorrect measurements.  
Do not use the Product around explosive gas, vapor, or in damp or wet  
environments.  
Use the Product only as specified or hazardous laser radiation exposure  
can occur.  
3
 
62 MAX/62 MAX +  
Users Manual  
Table 1. Symbols  
Symbol  
Symbol  
Meaning  
Meaning  
Do not dispose of this product as  
unsorted municipal waste. Go to  
Fluke’s website for recycling  
information.  
Risk of danger. Important  
information. See Manual.  
~
W
Conforms to European Union  
directives.  
Warning. Laser.  
Battery  
P
*
Conforms to relevant Australian  
standards.  
4
 
Infrared Thermometer  
Maintenance  
Maintenance  
WCaution  
To avoid damage to the Product, do not leave the thermometer on or near  
objects of high temperature.  
How to Change the Battery  
To install or change the AA IEC LR06 battery, open the battery compartment and replace the  
battery as shown in Figure 16.  
How to Clean the Product  
Use soap and water on a damp sponge or soft cloth to clean the Product case. Carefully wipe  
the surface with a moist cotton swab. The swab may be moistened with water. See Figure 17.  
5
 
 
62 MAX/62 MAX +  
Users Manual  
Specifications  
62 MAX  
62 MAX +  
-30 °C to 650 °C  
(-22 °F to 1202 °F)  
-30 °C to 500 °C  
(-22 °F to 932 °F)  
Temperature Range  
0 °C: 1.5 °C or 1.5 % of  
reading, whichever is  
greater  
(32 °F: 3 °F or 1.5 % of  
reading, whichever is  
greater)  
-10 °C to <0 °C: 2 °C  
(14 °F to <32 °F: 4 °F)  
< -10 °C: 3 °C  
0 °C: 1 °C or 1 % of  
reading, whichever is  
greater (32 °F: 2 °F or  
1 % of reading, whichever  
is greater)  
-10 °C to <0 °C: 2 °C  
(14 °F to <32 °F: 4 °F)  
< -10 °C: 3 °C  
Accuracy  
(<14 °F: 6 °F)  
(<14 °F: 6 °F)  
Response Time (95 %)  
Spectral Response  
Emissivity  
<500 ms (95 % of reading)  
<300 ms (95 % of reading)  
8 to 14 microns  
0.10 to 1.00  
6
 
 
Infrared Thermometer  
Specifications  
10:1  
12:1  
Optical Resolution  
Display Resolution  
Repeatability (% of reading)  
Power  
(calculated at 90 % energy)  
(calculated at 90 % energy)  
0.1 °C (0.2 °F)  
0.8 % of reading or 1.0 °C  
(2 °F), whichever is greater  
0.5 % of reading or 0.5 °C  
(1 °F), whichever is greater  
1 AA IEC LR06 Battery  
10 hours with laser and  
backlight on  
8 hours with laser and  
backlight on  
Battery Life  
Weight  
255 g (8.99 oz)  
Size  
(175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches  
0 °C to 50 °C (32 °F to 122 °F)  
-20 °C to 60 °C (-4 °F to 140 °F), (without battery)  
10 % to 90 % RH non-condensing @ 30 °C (86 °F)  
2000 meters above mean sea level  
Operating Temperature  
Storage Temperature  
Operating Humidity  
Operating Altitude  
Storage Altitude  
12,000 meters above mean sea level  
7
 
62 MAX/62 MAX +  
Users Manual  
IP Rating  
IP 54 per IEC 60529  
Drop Test  
3 meters  
Vibration and Shock  
EMC  
IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms  
EN 61326-1:2006 EN 61326-2:2006  
Standards and Agency Approval  
Compliance .............................................EN/IEC 61010-1: 2001  
Laser Safety............................................FDA and EN 60825-1 Class II  
8
 
 
Infrared Thermometer  
The Product  
The Product  
1
2
gtt01.eps  
9
 
 
62 MAX/62 MAX +  
Users Manual  
3
4
5
6
/
5
Max/Min/Avg/Diff  
gtt14.eps  
10  
 
Infrared Thermometer  
The Product  
7
+
=
10 min  
OFF  
gtt16.eps  
11  
 
62 MAX/62 MAX +  
Users Manual  
8
9
30 Min  
10  
11  
12  
9
3
0ºC  
32ºF  
6
22ºC  
72ºF  
125°F  
gtt15.eps  
12  
 
Infrared Thermometer  
The Product  
12  
13  
60 mm @ 100 mm @  
38 mm @  
300 mm  
33 mm @ 50 mm @ 85 mm @  
600 mm  
900 mm  
300 mm  
600 mm  
900 mm  
S
S
1.5" @ 2.4" @  
4" @  
36"  
1.4" @  
12"  
2" @  
24"  
3.4" @  
36"  
12"  
24"  
D
D
62 MAX +  
D:S = 12:1  
62 MAX  
D:S = 10:1  
gtt08-11.eps  
13  
 
62 MAX/62 MAX +  
Users Manual  
14  
70  
21  
gtt03.eps  
14  
 
Infrared Thermometer  
The Product  
15  
75°  
225°  
75°  
gtt04.eps  
15  
 
62 MAX/62 MAX +  
Users Manual  
16  
17  
-
+
gtt13.eps  
16  
 

Extron electronic TV Video Accessories EDID 101D User Manual
Fellowes Car Stereo System 2233BW User Manual
Fitness Quest Home Gym 386da User Manual
Frigidaire Dishwasher FGHD2433K F W B User Manual
Gardena Elliptical Trainer 1242 1250 1243 1244 1245 User Manual
GE Car Video System VTPR1000 User Manual
GE Clothes Dryer DCVH680EJ User Manual
GE Home Security System 60 960 95 User Manual
GE Refrigerator 200D2600P043 User Manual
Gianni Industries Door GL 80F User Manual