Field Controls Air Conditioner CAC 120 User Manual

CAC-120 COMBUSTION  
AIR CONTROL  
This kit is designed to control more than one appliance on a system using the Field Controls CAS-3  
Combustion Air System with a chimney vented oil fired system. The controls in the CAS-3 will operate only  
one appliance, therefore a CAC-120 is required for each additional appliance to be added to the same  
CAS-3 unit. One CAS-3 unit can handle at max, a total combined firing rate input of up to 500,000 BTU/  
Hr. Refer to the instructions included with the CAS-3 for more details and other restrictions.  
Items Included In Kit:  
1) Junction box with mounted fan proving switch and relay base  
1) 120 VAC relay  
1) Conduit connector  
1) 10 Ft. length of 14" plastic tubing  
1) Plastic Tee  
Mounting Junction Box:  
The junction box may be mounted anywhere that is convenient for routing the wiring and tubing. Mount the  
CAC-120 to a wall or floor joist using the four dimpled locations on the base of the box (See Figure 1.)  
Note: The unit must be mounted so the draft proving switch is vertical as shown in Figure 1. The CAC-120  
should be placed close enough to the CAS unit to route the provided 10 foot long plastic tubing from the  
draft proving switch to the exposed tubing on the CAS. If mounting further away, the installer must provide  
any necessary fittings and extra tubing.  
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.  
This device MUST be installed by a qualified agency in accordance with the manufacturer's installation instructions. The definition of  
a qualified agency is: any individual, firm, corporation or company which either in person or through a representative is engaged  
in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the  
precautions required, and has complied with all the requirements of the authority having jurisdiction.  
Please retain these instructions after installation.  
Installed By:  
Phone:  
Installation Date:  
 
Fan Proving Switch Air Sensing Tube Installation:  
1. Attach the provided plastic tubing to the fan proving switch on the CAC-120 using the plastic  
compression fitting on the switch.  
2. Cut the exposed tubing on the CAS-3 as shown in Figure 2. Install the provided plastic Tee and connect  
the tubing from the CAC-120 to the Tee.  
Figure 2  
page 3  
 
LIMITED WARRANTY  
Field Controls, LLC (“Company”) warrants that its products shall be free from defects in material and workmanship  
under normal use for the limited period indicated, from the date of manufacture, subject to the provisions 1-8 below.  
Eighteen (18) months  
All Field Controls Products (except for those listed below as 5 years or 90 days).  
Five (5) years  
Field Controls Direct Vent Systems (FDVS), Field Oil Vent Kits (FOVP), and ComboVents (CV).  
Field Controls warrants that the products listed below shall be free from defects in material and workmanship under  
normal use for the limited period indicated, from the date of purchase by the consumer, subject to the provisions  
1-8 below.  
Ninety (90) days  
UV lamps/bulbs  
Provisions:  
1. During the limited warranty period, Company, or its authorized service representative, will repair or replace, at Company’s  
option, without charge, a defective Product. Product that is repaired may be repaired with new or refurbished replacement  
parts. Product that is replaced may be replaced with a new or refurbished product of the same or similar design. Company  
will return repaired or replacement Product to customer in working condition. Labor charges are not covered as part of the  
limited warranty.  
2. With regard to UV lamps/bulbs, customer shall be required to include a "valid proof of purchase" (sales receipt) identifying  
the Product purchased (Product model or accurate date code information) and the date the Product(s) was purchased.  
3. Product whose warranty/quality stickers, Product serial number plates or electronic serial numbers have been removed,  
altered or rendered illegible shall not be covered under the limited warranty.  
4. Defective Product must be returned to Company, postage prepaid.  
5. IN NO EVENT SHALL COMPANY BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR SIMILAR  
DAMAGES (INCLUDING, BUT NOT LIMITED TO, LOST PROFITS OR REVENUE, INABILITY TO USE PRODUCT, OR OTHER  
ASSOCIATED EQUIPMENT, THE COST OF SUBSTITUTE EQUIPMENT, AND CLAIMS BY THIRD PARTIES) RESULTING FROM  
THE USE OF PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the  
above limitation or exclusion may not apply to you.  
6. THIS WARRANTY AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, REMEDIES AND  
CONDITIONS, WHETHER ORAL, WRITTEN, EXPRESS, STATUTORY OR IMPLIED. TO THE EXTENT PERMITTED BY LAW,  
COMPANY DISCLAIMS ALL IMPLIED AND STATUTORY WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY  
AND FITNESS FOR A PARTICULAR PURPOSE.  
7. Company makes no warranty of any kind in regard to other manufacturer’s products distributed by Company. Company will  
pass on all warranties made by the manufacturer and where possible, will expedite the claim on behalf of the customer, but  
ultimately, responsibility for disposition of the warranty claim lies with the manufacturer.  
8. Product that has been subjected to misuse, accident, shipping or other physical damage, improper installation or application,  
abnormal operation or handling, neglect, fire, water or other liquid intrusion are not covered by the warranty.  
Phone: 252.522.3031 • Fax: 252.522.0214  
© Field Controls, LLC  
P/N 46188900 Rev B 08/09  
 

Electro Voice Microphone PL24 User Manual
Exido Kitchen Grill 243 045 User Manual
Extron electronic Portable Generator BBG 6 A User Manual
Fisher Price Dollhouse 77974 User Manual
FujiFilm Digital Camera XP10 User Manual
Fujitsu Battery Charger FMW51BC1 User Manual
GE Electronic Accessory ge multilin User Manual
GE Fryer 169030 User Manual
Generac Power Systems Portable Generator NP Series User Manual
GE Refrigerator 162D9639P004 User Manual