Extron electronic Stereo System MHRVGA User Manual

Specifications — MHRVGA Cable  
UL NEC/  
C(UL) CEC  
UL AWM  
Temp.  
Standard  
Lengths Weights  
Shipping Conductor  
Nominal  
Core OD  
Shielding  
Materials  
(% coverage)  
Nom. DCR  
Nominal  
OD  
Nominal  
Capacitance  
Nominal  
Attenuation  
Description  
Nom.  
Vel.  
of  
No.  
of  
Cond.  
Nom.  
Imp.  
(ohms)  
(stranding)  
Diameter  
Nom. DCR  
Part No. (length)  
Model  
dB/  
dB/  
MHz  
Prop.  
Ft.  
m
Lbs. kg  
Inch mm  
Inch mm  
pF/ft pF/m  
100 ft 100 m  
Composite Cable: (3) 26 AWG Miniature Coax • (2) 26 AWG Shielded Twisted Pairs • (7) 26 AWG Insulated Conductors  
Overall Cable Shield: Aluminum Foil (100%) + Tinned Copper Braid  
Nonplenum Cable • Natural Foamed Polyolefin Insulation • PVC Inner Jackets • Gray PVC Outer Jacket  
1
5
10  
20  
50  
-0.5  
-1.2  
-1.7  
-2.4  
-3.8  
-4.5  
-5.4  
-6.3  
-7.3  
-7.7  
-9.1  
-11.5  
-16.4  
-19.5  
-43.6  
-1.7  
-3.9  
-5.5  
26 AWG  
(7/34)  
0.019"  
Alum. Foil  
(100%)  
3
coax  
0.076 1.93  
75  
83%  
18.0  
59.1  
500 152.4 54 24.5  
304.8  
Single:  
0.105 2.67  
red, green, blue  
22-024-01 (500')  
22-024-03 (1000')  
1000  
95 43.1  
Tinned Cu  
Serve (95%)  
-7.8  
MHRVGA  
0.48 mm,  
-12.3  
-14.8  
-17.6  
-20.6  
-23.9  
-25.4  
-29.9  
-37.3  
-53.8  
-64.0  
-143.0  
Tinned Cu  
12.2 ohms/  
1k ft,  
40.0 ohms/  
1 km  
71  
100  
135  
180  
200  
270  
400  
750  
1000  
3000  
41 ohms/  
1k ft,  
135 ohms  
1 km  
Sweep tested 5 MHz to 1 GHz.  
66% 35 115  
Same as  
above  
Tinned Cu  
Braid (85%)  
Single:  
black & red  
black & white  
2
0.033 0.84  
NEC CM  
UL 1581  
CSA FT-4  
AWM 2990  
VW-1  
shielded  
twisted  
pairs  
conductor-  
conductor  
62  
203  
conductor-  
conductor,  
connected to  
shield  
Min. bend radius: 4.0"  
60 °C  
Same as  
above  
Single:  
blue, green,  
violet, grey,  
yellow, orange,  
brown  
7
0.033 0.84  
insulated  
conduct-  
ors  
Alum. Foil and  
Tinned Cu  
Braid (85%)  
Overall:  
Overall  
cable  
0.330 8.39  
gray  
Plenum Cable • Natural Foamed FEP Insulation • PVC Inner Jackets • Blue Fire-Resistant PVC Outer Jacket  
58  
1
5
10  
20  
50  
-0.5  
-1.1  
-1.6  
-2.3  
-3.6  
-4.3  
-5.1  
-6.0  
-7.0  
-7.4  
-8.8  
-11.8  
-17.6  
-21.4  
-51.2  
-1.5  
-3.7  
-5.4  
152.4  
26 AWG  
(7/34)  
0.019"  
Alum. Foil  
(100%)  
500  
26.3  
3
coax  
0.074 1.88  
75  
81%  
16.7  
54.8  
Single:  
0.102 2.60  
red, green, blue  
22-131-02 (500')  
22-131-03 (1000')  
1000 304.8 99 44.9  
Tinned Cu  
Serve (95%)  
-7.5  
MHRVGAP  
0.48 mm,  
-11.8  
-14.1  
-16.8  
-19.7  
-23.0  
-24.3  
-28.8  
-38.7  
-57.8  
-70.1  
-168.0  
Tinned Cu  
12.2 ohms/  
1k ft,  
40.0 ohms/  
1 km  
71  
100  
135  
180  
200  
270  
400  
750  
1000  
3000  
41 ohms/  
1k ft,  
135 ohms  
1 km  
Sweep tested 5 MHz to 1 GHz.  
66% 35 115  
Same as  
above  
Tinned Cu  
Braid (85%)  
Single:  
black & red  
black & white  
2
0.033 0.84  
shielded  
twisted  
pairs  
conductor-  
conductor  
NEC CMP  
UL 910  
75 °C  
62  
203  
conductor-  
conductor,  
connected to  
shield  
Min. bend radius: 6.0"  
Same as  
above  
Single:  
blue, green,  
violet, grey,  
yellow, orange,  
brown  
7
0.033 0.84  
insulated  
conduct-  
ors  
Alum. Foil and  
Tinned Cu  
Braid (85%)  
Overall:  
Overall  
cable  
0.330 8.38  
blue  
02 December, 2008  
 

Eton Weather Radio G1000A User Manual
Excalibur electronic Games EI PT1001 User Manual
FEIN Power Tools Grinder WSG 20 180 User Manual
Fujitsu Laptop SPFC T901 DGFX 1 User Manual
Fujitsu Scanner iX500 User Manual
GBC Paper Shredder 3550X User Manual
GE Clothes Dryer 234D1050P001 User Manual
GE Cooktop AHH50 User Manual
GE Home Security System 45136 User Manual
GE Washer WWA8657R User Manual