IN1124/IN1128/IN1130 TP Wiring Guide
The design of Extron Enhanced Skew-Free™ A/V UTP (unshielded twisted pair)
cable has changed. The new design makes the TIA/EIA T 568A wiring standard
incompatible with the Extron IN1124, IN1128, and IN1130 TP transmitters and
receivers.
Contrary to the instructions stated in the IN1124, IN1128, IN1130 manual
(part # 68-754-01) and affixed to the side of spools of Enhanced Skew-Free A/V
UTP cable, do not terminate the cable in accordance with the TIA/EIA T 568A
wiring standard. Rather, terminate the Enhanced Skew-Free A/V UTP cable in
accordance with the diagram on the reverse side of this card.
The TIA/EIA T 568 A and TIA/EIA T 568 B wiring standards are
acceptable for the IN1124, IN1128, and IN1130 when using Category
(CAT) 5, 5e, or 6 cables only.
Extron Electronics, USA
1230 South Lewis Street
Anaheim, CA 92805
USA
Extron Electronics, Europe
Beeldschermweg 6C
3821 AH Amersfoort
The Netherlands
Extron Electronics, Asia
135 Joo Seng Road, #04-01
PM Industrial Building
Singapore 368363
Extron Electronics, Japan
Daisan DMJ Building 6F
3-9-1 Kudan Minami
Chiyoda-ku, Tokyo 102-0074 Japan
+81.3.3511.7655
68-754-02
Rev. A
05 04
714.491.1500
+31.33.453.4040
+65.6383.4400
Fax 714.491.1517
Fax +31.33.453.4050
Fax +65.6383.4664
Fax +81.3.3511.7656
Printed in the USA
Side
Clip Down
12345678
RJ-45 connector
Skew-Free cable
Wire color
Pin
Signal
1
White-green
Red/V. sync+
2
3
4
5
Green
Red/V. sync-
Green/H. sync+
Blue+
White-brown
Blue
White-blue
Blue-
12345678
6
7
8
Brown
Green/H. sync-
Mono audio +
Mono audio -
White-orange
Orange
Twisted
Pairs
NOTE If you are using Enhanced Skew-Free™
UTP A/V cable, use the wiring scheme
shown on this card only.
1&2
7&8
3&6 4&5
|