B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 1
MAINS POWERED
CARBON MONOXIDE ALARM
- HARD WIRED TO MAINS
Model Ei 225EN
- WITH POWER CORD
Model Ei 220EN
Read and retain carefully for as long as the product is being used. It contains vital information
on the operation and installation. The leaflet should be regarded as part of the product.
If you are just installing the unit, the leaflet must be given to the householder. The leaflet is to
be given to any subsequent user.
INSTRUCTIONS
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 3
1. READ THIS FIRST
WARNING: The Ei225EN Alarm should be permanently wired to the mains by a
qualified electrician in accordance with IEE wiring regulations (BS7671).
The Ei220EN is just plugged in to the mains.
Install the Carbon Monoxide Alarm (CO Alarm) in every room that contains a fuel
burning appliance, particularly rooms where people spend a lot of time e.g.
bedrooms, kitchens and sitting rooms.
In rooms with an appliance install (preferably) on the ceiling, (300mm from
walls), and between 1m to 3m horizontally from appliance. In rooms remote from
the appliance install at breath level, where the light indicators can be seen.
Regularly check that the green power light is on. Important: The CO Alarm will
not work if the mains supply is off.
Test the unit weekly by pressing the test/hush button-the horn will sound.
Open the unit by sliding the cover up as shown in figure 1. Then remove the
terminal block screw. (Ei225EN only).
Immediately the unit is powered the green light will turn on & the red & amber
lights will flash once to show they are operational.
?
Replace unit after up to 6 years operation (see ‘Replace by’ date on sidewall
label).
?
3
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 4
When the CO Alarm detects abnormal levels of CO (above 50ppm CO) the red
light starts to flash and the horn will sound within 90 minutes. At higher levels
of CO the alarm will turn on sooner (see table B - page 9).
The CO Alarm will automatically reset once the CO has cleared. Pressing the
test/hush button resets the CO Alarm immediately (below 300ppm CO). If CO is
?
still present the red light and horn will turn on again after about 4 minutes.
The CO Alarm is no substitute for keeping chimneys and flues clear and in good
condition, and all of your appliances serviced regularly according to the
?
manufacturers’ instructions.
Do not fit alarm until all building work is completed to avoid contamination.
2. WHAT TO DO WHEN THE ALARM SOUNDS
(1) Open the doors and windows to ventilate the area.
(2) Turn off all fuel appliances where possible and stop using them. (The alarm
can be silenced immediately by pushing the test/hush button).
(3) Evacuate the property leaving the doors and windows open.
(4) Get medical help immediately for anyone suffering the effects of Carbon
Monoxide poisoning (headache, nausea), and advise that Carbon Monoxide
poisoning is suspected.
4
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 5
(5) Ring your gas or other fuel supplier on their emergency number. Keep the
number in a prominent place.
(6) Do not re-enter the property until the alarm has stopped. (If the alarm has been
silenced by pressing the test/hush button, wait at least 5 minutes so the alarm can
check that the CO has cleared).
(7) Do not use the fuel appliances again until they have been checked by an
expert. In the case of gas appliances this must be a CORGI registered installer.
Figure 1 - Alarm Installation
3. CARBON MONOXIDE
- THE SILENT KILLER!
2.1 What is Carbon Monoxide ?
Congratulations on becoming the owner of
an Ei Carbon Monoxide Alarm. This will
TERMINAL
BLOCK
COVER
SCREW
(Ei225EN only)
PRESS HERE
FIRST AND
SLIDE UP
help protect you and your household from
the dangerous effects of Carbon Monoxide
- the silent killer. (CO is the chemical
symbol, indicating the molecule has one
carbon atom and one oxygen atom).
MOUNTING
HOLES
GAS
ENTRY
HOLES
Many are killed each year, and many more
suffer ill health from Carbon Monoxide
5
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 6
(CO) poisoning. CO is an invisible, odourless, tasteless and extremely toxic gas. It is
produced by appliances and vehicles burning fuels, such as coal, oil, natural/bottled
gas, paraffin, wood, petrol, diesel, charcoal etc. CO is absorbed by red blood cells in
the lungs in preference to oxygen - this results in rapid damage to the heart and brain
from oxygen starvation.
High levels of CO in a house can be caused by:
• Incorrectly or poorly installed fuel-burning appliances.
• Blocked or cracked chimneys/flues.
• Blocked vents or draught-proofing which makes areas with fuel burning appliances
or fireplaces airtight.
• Engines of cars, lawnmowers etc. left running in confined spaces.
• Portable paraffin or gas heaters in badly ventilated rooms.
2.2 Symptoms of Carbon Monoxide Poisoning
Most people know that high levels of CO are harmful, however the period of exposure
is also important.
The following symptoms are related to Carbon Monoxide poisoning and should be
discussed with all members of the household.
6
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 7
Mild Exposure: Slight headache, nausea, vomiting, fatigue (often described as
“flu-like” symptoms).
Medium Exposure: Severe throbbing headache, drowsiness, confusion, fast heart
rate.
Extreme Exposure: Unconsciousness, convulsions, cardiorespiratory failure, death.
A high level of CO for a short period (e.g. 350 ppm CO for 30 minutes) will cause the
same symptoms, a slight headache, as a lower level for a longer time (e.g. 150 ppm
for 90 minutes). Table A shows how exposure to different concentrations of CO
generally affects people.
Many cases of reported Carbon Monoxide poisoning indicate that while victims are
aware they are not well, they become so disorientated they are unable to save
themselves by either leaving the building or calling for assistance. Young children and
household pets may be the first affected.
7
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 8
Table A: Effects of Carbon Monoxide Poisoning
Concentration
of CO in Air
Inhalation Time (approx) and Symptoms Developed
ppm
35
The maximum allowable concentration for continuous exposure in any 8 hour period
according to OSHA *.
150
Slight headache after 1.5 hours.
200
400
Slight headache, fatigue, dizziness, nausea after 2-3 hours.
Frontal headaches within 1-2 hours, life threatening after 3 hours, also maximum parts per
million in flue gas (on an air free basis) according to US Environmental Protection Agency.
800
Dizziness, nausea and convulsions within 45 minutes. Unconsciousness within 2 hours.
Death within 2-3 hours.
1,600
3,200
6,400
12,800
Headache, dizziness and nausea within 20 minutes. Death within 1 hour.
Headache, dizziness and nausea within 5-10 minutes. Death within 25-30 minutes.
Headache, dizziness and nausea within 1-2 minutes. Death within 10-15 minutes.
Death within 1-3 minutes.
ppm = parts per million
*OSHA Occupational Safety & Health Association
2.3 What happens when your CO Alarm detects Carbon Monoxide ?
When the Alarm detects potentally dangerous levels of CO, it flashes the red alarm
light and then sounds a loud alarm if the CO persists.
8
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 9
Table B shows how the CO Alarm reacts to different levels of CO gas and exposure time.
At higher levels of CO the alarm turns on sooner. The rate of flashing of the red light
indicates the level of CO.
Table B: CO Alarm Response
Red
Alarm Light
Horn On
within
CO Level
ppm
0 ppm
50ppm
Off *
Off
1 Flash / 2 Seconds
4 Flashes / 2 Second
8 Flashes / 2 Second
60 to 90 minutes
10 to 40 minutes
3 minutes
100 ppm
300 ppm
* unless it has been in alarm (see CO Alarm Memory below)
If your CO Alarm sounds follow the instructions on page 4.
When ventilation is provided by leaving the window and doors open, the CO build up
may have dissipated by the time help arrives and the alarm may have stopped
sounding. Although your problem may appear temporarily solved it is crucial that the
source of the CO is determined and appropriate repairs made.
NEVER IGNORE THE ALARM.
Pre-Alarm: When the alarm detects over 50ppm CO the red light flashes every 2
seconds. This helps locate CO leaks, as the unit gives an indication straight away.
9
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 10
(Without this feature the CO level would need to be at 50ppm CO for 90 minutes for
an indication to be given). Note the Pre-Alarm signal may be triggered by CO coming
for example, from cooking with gas, from car engines or from nearby barbecues. This
is usually not a concern unless the Pre-Alarm signal persists until the alarm sounds
and the CO source is unknown.
NOTE: The CO Alarm may sound if cigarette smoke is blown into it, or aerosols are
released nearby.
CO ALARM MEMORY
- Red light is Off – No CO detected since reset or power up.
- Red light flashes 2 times (in 2 seconds) every 40 seconds, 50 ppm CO detected
for least about 90 minutes.
- Red light flashes 4 times (in 2 seconds) every 40 seconds, 100 ppm CO detected
for least about 40 minutes.
- Red light flashes 8 times (in 2 seconds) every 40 seconds, 300 ppm CO detected
for at least about 3 minutes.
When the test button is pressed the horn will sound, and the red light will only flash if the
unit has previously detected CO and been in alarm. The flash rate indicates the level of
CO detected as in table B.
Reset Memory by holding down the test button for over 20 seconds until the red light
stops flashing. Cover the horn with a cloth to muffle the alarm during this time.
Please note that the memory will also be reset when the unit is unpowered.
10
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 11
4. WHERE TO PLACE CO ALARMS
3.1 Ideally a Carbon Monoxide Alarm should be installed in:
- Every room containing a fuel burning appliance, and
- Remote rooms where occupants spend a considerable amount of time
- Every bedroom.
However if the number of Carbon Monoxide Alarms is limited the following points
should be considered when deciding where best to fit the alarm(s)
- If there is an appliance in a room where people sleep, place a CO Alarm in this room and
- Locate a CO alarm in a room containing a flueless or open-flued appliance, and
- Locate an alarm in a room where the occupant(s) spend most of their time (e.g.
sitting room) and
- In a bedsit, the CO alarm should be placed as far away from the cooking appliance
as possible, but near to where the person sleeps and
- If the appliance is in a room not normally used, such as a boiler room, the CO alarm
should be placed just outside the room so that the alarm will be heard more easily.
3.2 Unsuitable Locations
Do not place the CO Alarm in any of the following areas.
(1) In the immediate vicinity of a cooking appliance (keep it at least 1 metre
horizontally from it).
11
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 12
(2) Outside the building.
(3) In an enclosed space (e.g. in or below a cupboard).
(4) In a damp or humid area.
(5) Directly above a sink or cooker.
(6) Next to a door, window, air vent or anywhere that it would be affected by
draughts.
(7) Next to an extractor fan.
(8) Where it would be obstructed, e.g. by curtains or furniture.
(9) In an area where the temperature could drop below –10°C or rise above 40°C.
(10) Where dirt or dust could block the sensor.
(11) Where it could be easily knocked or damaged, or where it could be accidentally
turned off or removed.
(12) In a bathroom or other areas where the CO alarm may be exposed to water
splashes, dripping or condensation (e.g. above an electric kettle).
(13) Near paint, thinners, solvent fumes or air fresheners.
3.3 If locating the CO alarm in a room with a fuel burning appliance (see figure 2)
• If it is mounted on a wall, it should be located at a height greater than the height of
any door or window but still be at least 150mm from the ceiling.
• If it is mounted on the ceiling it should be at least 300mm from any wall or light fitting.
12
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 13
• The CO alarm should be a horizontal distance of between 1m and 3m from the
potential CO source.
• If there is a partition in the room, the CO alarm should be located on the same side
of the partition as the potential source.
• In rooms with sloped ceilings, the CO alarm should be located at the high side of the
room (see fig 3).
300mm
CO Alarm
150mm
1 to 3 m
DEAD AIR
DON'T LOCATE
HERE
1 to 3 m
Figure 2. Location in room with a fuel burning appliance
13
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 14
3.31 If locating the CO alarm in a bedroom or in rooms remote from a fuel
burning appliance (see figure 4)
• Mount the CO alarm relatively close to the breathing zone of the occupants.
Whatever position is chosen make sure it is possible to view the three light indicators,
when in the vicinity of the alarm.
CO Alarm
CO Alarm
about
1 to 2m
Figure 3. Location in rooms with
sloped ceilings, the CO alarm should
be located at the high side of the room
Figure 4. Location in bedroom &
rooms remote
from the appliance
(i.e. at breathing level)
14
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 15
5. INSTALLING YOUR CARBON MONOXIDE ALARMS
The Alarm is designed to be permanently mounted. The unit can be screwed directly
to the wall or ceiling and connected to the mains. It requires a current of 60mA. The
Alarm must not be exposed to dripping or splashing. There are important markings on
the underside of the alarm.
IMPORTANT PRECAUTION: Do not install the actual alarm itself in new or
renovated buildings until all work is completed (including floor coverings) and
the building has been fully cleaned. The wiring can be installed when
appropriate. (Excessive dust and debris from building work can contaminate the
sensor and cause problems, it will also invalidate the guarantee). If it must be
installed, cover it completely, particularly around the edges, with a dust cover,
until all cleaning is finished.
The Ei225EN Alarm must not be connected when the house wiring insulation is being
checked with high voltages i.e. don’t use an insulation tester on the alarm.
WARNING: Do not use the CO Alarm on an intermittent basis, or as a portable detec-
tor for the spillage of combustion products from fuel burning appliances or chimneys.
WARNING: The Alarm must be continuously powered 24 hours a day so it is
important that it is not on a circuit that can be turned off by a switch.
15
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 16
INSTALLATION PROCEDURE
Ei225EN (Only)
Warning: The CO alarm should be installed by a qualified electrican in accordance with
the IEE wiring regulations (BS 7671). Failure to install this alarm correctly may expose
the user to shock or fire hazards.
Procedure:
1. Select a location complying with the above advice.
2. Disconnect the AC mains supply from the circuit to be used.
3. Slide off the cover as shown in fig 1. Press gently in the centre to release the catches
before sliding upwards.
4. Remove the terminal cover screw and expose the connecting terminals.
5. (a) If the wires are coming directly out from the ceiling/wall locate the wire entry
slot over the wires and mark the two mounting screw locations. Screw the unit to the
ceiling/wall (ensure screws do not penetrate buried wires. The unit can also be
screwed on to a standard recessed junction box if required. Seal the wire exit holes
(with silicone or similar) to prevent air draughts preventing the carbon monoxide from
reaching the sensor.
(b) If surface wiring is being used, bring the wiring in from either of the vertical sides
or the bottom as shown in figure 5. Note surface wiring cannot be brought in from the
top as it would be in the way of the cover sliding off and also might allow water to
penetrate. Screw the unit to the wall.
16
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 17
6. The Brown wire (terminal 3) must be connected to the house wiring coloured
brown or to a house terminal marked “L”. The Blue wire (terminal 4) must be
connected to the house wiring coloured blue or to a house terminal marked “N”.
The alarm does not need to be earthed, however for convenience a spare terminal
(no. 5) is provided to hold an earth wire if present.
7. Turn on the mains power to the CO Alarm circuit.
Figure 5 - Surface Wiring
Figure 6 - Recessed Wiring
Not Suitable
Locations for
Surface Wiring
Conduit
17
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 18
Ei220EN (Only)
1. Slide the cover off as shown in Figure 7 to expose the mounting screw holes.
2. Cut a notch in the back sidewall (on the centre of either side or at the bottom, for
the power cord) to allow the unit to lie flush against the ceiling/wall.
3. Mark the two screw locations. Drill suitable holes (6mm drill) then insert the
plastic anchors and screw the unit to the ceiling/wall.
4. Insert the plug into a suitable socket.
Figure 7
Warning: Do not open (apart
from the cover shown in fig-
ure 7) or tamper with the CO
Alarm. There are no user
serviceable parts inside.
This can damage the unit
and may expose the user to
shock or fire hazards.
18
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 19
6. TESTING YOUR CO ALARM
(1) Regularly check that the green mains power light is on. The unit cannot detect CO
if the mains power is not on. (If it is off check circuit breakers, fuses, wiring etc).
(2) Test the unit weekly by pressing the test/hush button. Hold the test button (for up
to 10 seconds) until the horn sounds for over 5 seconds. This will help to familiarise
you and your family with the distinctive on-off sound of the CO Alarm. This test checks
that the electronics and horn are working correctly. (If the red alarm light flashes when
the button is pressed - see CO Alarm Memory section on page 10.
(3) If the CO Alarm gives a short beep and the amber fault light flashes every 40
seconds it means the self-checking circuit has detected a fault. Press and hold the
test/hush button. If the amber light flashes without the horn sounding, the sensor is
faulty.
(4) If the Alarm fails to operate when the test/hush button is pressed, disconnect the
mains supply at the distribution fuse board for 3 minutes. Re-connect the mains and
try again. (This procedure resets the microprocessor in the unit).
(5) If the CO Alarm fails any of the above tests it must be replaced immediately (see
section 11 “Getting the CO Alarm Serviced” on page 28).
Testing with Carbon Monoxide
The unit can be tested with CO by using one of the kits that comes with CO either in
a glass phial or aerosol can. Follow the instructions on the kit. It is best if possible to
19
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 20
inject the CO gas into the gas entry holes, see Figure 1. When it senses the CO it
flashes the red light (as per Table B) to confirm that is detecting CO gas.
How to distinguish between CO Alarm and Smoke Alarm Warnings
The CO Alarm has a distinctive on-off sound of 3 pulses, followed by a pause as
compared with a typical Smoke Alarm which has a rapid pulsing sound.
In addition, when your CO Alarm is sounding, the red alarm light in the centre of the
cover will be flashing.
Testing both your CO Alarms and Smoke Alarms weekly will help you and your family
to clearly distinguish between them in an emergency.
7. MAINTAINING YOUR CO ALARM
Clean the outside case by occasionally wiping with a clean damp cloth, (after first
disconnecting the mains supply on an Ei225EN unit at the distribution/fuse board or by
unplugging the Ei220EN unit). Do not use any cleaning agents, bleaches, detergents or
polishes, including those in aerosol cans. Avoid spraying air fresheners, hair spray, paint
or other aerosols near the CO Alarm. Do not place air fresheners near the unit.
Use the narrow nozzle of a vacuum cleaner to remove fluff and other contamination
from the cover slots to ensure CO gas can reach the sensor.
Caution: Do not paint the CO Alarm.
20
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 21
Remove the CO Alarm when decorating. Do not allow water or dust to contaminate the
alarm.
Warning: Do not open or tamper with the CO Alarm. There are no user serviceable
parts. This can damage the unit and may expose the user to shock or fire hazards.
END OF LIFE
When the unit has completed up to 6 years of operation the amber light will flash every
40 seconds. The entire unit must then be replaced.
It must also be replaced when the date on the ‘Replace unit by’ label on the side wall
is exceeded.
Product Disposal
The crossed out wheelie bin symbol on the product means that it should
not be put into household waste. Please recycle where facilities exist.
Check with your local authority or retailer for recycling advice.
The date code on the product indicates when the product was manufactured e.g.
05W40 means week 40 in the year 2005.
How to disconnect and remove the alarm:
Ei225EN only
1. First disconnect the mains supply to the CO Alarm circuit at the distribution / fuse
board.
2. Slide cover up as shown in figure 1.
21
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 22
3. Unscrew the terminal cover screw.
4. Disconnect the wires from the terminal block and make safe, particularly if the
circuit is going to be turned on again after the CO Alarm is removed.
5. Unscrew from the wall.
Ei220EN only
1. Unplug the unit.
2. Slide cover up as shown in figure 7.
3. Unscrew from the wall.
8. LIMITATIONS OF CO ALARMS
(1) The CO Alarm will not work without mains power. The green power light must be
on at all times as far as possible.
(2) Carbon Monoxide must enter the unit for it to be detected. There may be Carbon
Monoxide in other areas of the house (e.g. downstairs, in a closed room etc). but not
in the vicinity of the CO Alarm. Doors, air draughts and obstructions can prevent the
CO reaching the Alarm. For these reasons we recommend CO Alarms are fitted both
near and in bedrooms, particularly if bedroom doors are closed at night. Additionally
install in rooms where members of the household spend much of their time, and in
rooms with potential sources of CO gas.
22
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 23
(3) The CO Alarm may not be heard. The sound output is loud but it may not be heard
behind a closed door or if it is too far away. The Alarm may not wake up somebody
who has taken alcohol or drugs. The alarm sound may be masked by other sounds
such as T.V., stereo, traffic noise etc. Fitting CO Alarms on either side of closed doors
will improve their chance of being heard.This CO Alarm is not designed for people with
impaired hearing.
(4) CO Alarms don’t last indefinitely. CO Alarms are sophisticated electronic devices
with many parts. Although the alarm and its component parts have undergone
stringent tests, and are designed to be very reliable, it is possible that parts can fail.
Therefore, you should test your CO Alarm weekly. The CO Alarm must be replaced
after up to 6 years operation (see ‘Replace by’ date on side wall label).
(5) CO Alarms are not a substitute for life insurance. House-holders are responsible
for their own insurance. The CO Alarm warns of increasing CO levels, but we do not
guarantee that this will protect everyone from CO poisoning.
(6) CO Alarms are not suitable as early warning Smoke Alarms. Some fires produce
Carbon Monoxide, but the response characteristics of these CO Alarms are such that
they would not give sufficient warning of fire. Smoke Alarms must be fitted to give early
warning of fire.
The CO Alarm does not detect the presence of natural gas (methane), bottled gas
(propane, butane) or other combustible gases. Fit combustion gas alarms to detect
these.
WARNING: THIS CO ALARM IS DESIGNED TO PROTECT INDIVIDUALS FROM
23
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 24
THE ACUTE EFFECTS OF CARBON MONOXIDE EXPOSURE. IT WILL NOT FULLY
SAFEGUARD INDIVIDUALS WITH SPECIFIC MEDICAL CONDITIONS. IF IN DOUBT
CONSULT A MEDICAL PRACTITIONER.
9. HOW TO PROTECT YOUR FAMILY
Follow these guidelines to reduce the risk of Carbon Monoxide poisoning.
(1) Know and look out for tell-tale signs that Carbon Monoxide may be present.
These include:-
- The CO Alarm warning of abnormal levels.
- Staining, sooting or discolouration on or around appliances.
- A pilot light frequently going out.
- A strange smell when an appliance is working.
- A naked gas flame which is yellow or orange, instead of the normal blue.
- Family members (including pets) exhibiting the “flu-like” symptoms of CO
poisoning described above.
If any of these signs are present get the appliance checked out by an expert
before further use. If family members are ill get medical help.
(2) Choose all appliances and vehicles which burn fossil fuels such as coal, oil,
natural/bottled gas, paraffin, wood, petrol, diesel, charcoal etc. with care and
have them professionally installed and regularly maintained.
(3) These appliances must “breathe in” air to burn the fuel properly. Know where the
24
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 25
air comes from and ensure vents/air bricks etc. remain unobstructed (particularly
after building work).
(4) The appliances must also “breathe out” the waste gases (including the CO) –
usually through a flue or chimney. Ensure chimneys and flues are not blocked or
leaking, and get them checked every year. Check for excessive rust or cracks on
appliances and pipe work.
(5) Never leave your car, motor bike or lawnmower engine running in the garage
with the garage door closed. Never leave the door from the house to the garage
open if the car engine is running.
(6) Never adjust your own gas pilot lights.
(7) Never use a gas cooker or a barbecue for home heating.
(8) Children should be warned of the dangers of CO poisoning and instructed never to
touch, or interfere with the CO Alarm. Do not allow small children to press the
test/hush button as they could be subjected to excessive noise when the unit alarms.
(9) Leaving windows or doors slightly open (even a few inches) will significantly
reduce the risk of high levels of CO occurring. The high levels of draught-
proofing in modern houses reduces ventilation and can allow dangerous gases
to build up.
(10) Install CO Alarms in all the areas recommended in this leaflet.
(11) Recognise that CO poisoning may be the cause when family members suffer
from “flu-like” symptoms when at home but feel better when they are away for
extended periods.
25
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 26
10. TECHNICAL SPECIFICATION
Operating Voltage
Power
: 230±10% VAC, 50Hz
: 1 Watt, (60 mA)
Power on Indicator
Sensor
: Green Light on
: Electrochemical Sensor
CO Sensitivity
: Meets BS EN 50291: 2001.
Unit operates as per Table B (page 9).
Electrical Safety
: Complies with relevant sections of EN 60335-1: 1994
: Complies with BS EN 50270
Electromagnetic
Compatibility
Test/Hush Button
: Checks electronics and horn.
When the unit is alarming, after sensing CO, pressing the test/hush button
will immediately stop the horn (the red light will continue to flash). If CO is
still present the red light and the horn will turn on again after about 4
minutes. The unit can only be silenced once during a CO incident. At 300
ppm CO the unit cannot be silenced. (With interconnected units, the hush
only works on the alarm sensing CO).
Testing with CO
: The red light flashes (see Table B, page 9) within 10
seconds of the unit detecting CO.
26
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 27
Initialisation Time
: 70 seconds. On power up red and amber lights flash
momentarily to show they are operational.
Operating Temperature : -10°C to 40°C
Humidity Range
: 15% to 95% R.H. (non-condensing)
Audible Alarm
Self Diagnostics
: 85dB(A) at 3m minimum
: Horn beep and amber fault light flashes every 40 seconds if a
sensor fault is found.
Tamperproof
: Ei225EN - Screwdriver needed to unscrew unit from wall.
Mains cover over terminal block screw must also be removed.
Ei220EN - Screwdriver needed to unscrew unit from wall.
End of Life Indication:
CO Alarm Memory:
Amber light flashes every 45 seconds after 6 years to
show the unit must be replaced.
: A unit will indicate if it has been in alarm previously by
flashing the red light for 2 seconds every 40 seconds (2
flashes for 50 ppm CO, 4 flashes for 100 ppm CO and 8
flashes, for 300 ppm CO). When the test button is
pressed the red light flashes as per table B and also
indicates the previous CO alarm level detected. The
memory is cleared by holding down the test button until
the red light stops flashing or if the unit is unpowered.
27
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 28
Dimensions
Weight
: 135 x 105 x 71 mm.
: 195g - Ei225EN
290g - Ei220EN
11. GETTING THE CO ALARM SERVICED
If your CO Alarm fails to work after you have carefully read all the instructions, checked
the unit has been installed correctly, and is receiving AC power, - see “How to disconnect
and remove the Alarm” in section 7, page 20. Return it for repair or replacement. This
should be to where it was purchased, alternatively return it in a padded box to “Customer
Assistance and Information” at the nearest address given on the CO Alarm or in this
leaflet. State the nature of the fault, where the CO Alarm was purchased, and the date of
purchase.
12. GUARANTEE
Ei Electronics guarantees the Ei225EN Carbon Monoxide Alarm for five years from the
date of purchase against any defects that are due to faulty materials or workmanship.
Ei Electronics guarantees the Ei220EN Carbon Monoxide Alarm for two years from the
date of purchase against any defects that are due to faulty materials or workmanship.
This guarantee only applies to normal conditions of use and service, and does not
include damage resulting from accident, neglect, misuse, unauthorised dismantling, or
contamination howsoever caused.
28
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 29
This guarantee excludes incidental and consequential damage. If this Carbon
Monoxide Alarm should become defective within the guarantee period, it must be
returned to where it was purchased or alternatively to Ei Electronics., carefully
packaged, with the problem clearly stated. (see section 11 “Getting the CO Alarm
Serviced”) along with proof of the date of purchase. We shall at our discretion repair
or replace the faulty unit.
29
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 30
13. TROUBLESHOOTING
1. ALARM DOES NOT WORK WITH THE TEST BUTTON:
(1) Check that the green mains power light is on. If it is off check the wiring, fuse,
circuit breakers etc.
(2) Hold the test button down for at least 5 seconds.
2. ALARM BEEPS AND AMBER LIGHT FLASHES EVERY 40 SECONDS:
If the alarm beeps and the amber fault light flashes every 40 seconds, the CO sensor
is probably defective. Press the test/hush button to reset the unit. If the beeping and
the amber light flashing re-occurs replace the unit.
3. AMBER LIGHT FLASHES EVERY 40 SECONDS
The unit has been operating for up to 6 years and must be replaced.
4. ALARM SOUNDS FOR NO APPARENT REASON:
Follow the detailed instructions on page 4. entitled “What to do when the alarm
sounds”. If there are still problems:
(1) Ensure there are no fuel-burning appliances in the vicinity which could be leaking
CO gas (e.g. even from next door).
30
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 31
(2) Ensure there are no fumes in the area (e.g. paint, thinners, alcohol, hair spray,
chemical cleaners aerosol sprays etc).
(3) Ensure there is no outdoor source of CO in the vicinity (e.g. a car with engine
running, heavy traffic, heavy air pollution, barbecue fumes etc).
(4) Press the test/hush button to silence the alarm.
If the unit continues to sound it is possibly defective and should be replaced, follow the
instructions in section 7 on “How to disconnect and remove your alarm” and then see
section 11 “Getting the CO Alarm Serviced”.
4. TEST/HUSH BUTTON DOES NOT SILENCE ALARMS:
Hush button will only silence the unit once at CO levels less than 300 ppm CO during
a CO incident.
5. THE RED AND AMBER LIGHTS FLASH:
On power up the red and amber lights turn on in sequence to show they are working.
THIS IS NORMAL.
31
B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 32
PRODUCT DISPOSAL
Ei Electronics
Shannon, Co. Clare, Ireland.
Tel: (061) 471277 Fax: (061) 471053
E-mail. [email protected]
Aico Ltd.
Mile End Business Park, Maesbury Rd, Oswestry,
Shropshire, SY10 8NN,
U.K. Tel: 0870 7584000 Fax: 0870 7584010
E-mail: [email protected]
© Ei Electronics 2005
P/N B15584 Rev 0
|