USER'S
MANUAL
FA162C Security System
N7527-1V2 Rev B 4/99
TABLE OF CONTENTS
SYSTEM OVERVIEW .............................................................. 4
USING DEVICE COMMANDS ............................................... 25
PAGING FEATURE ............................................................... 27
General ............................................................................... 4
A Partitioned System .......................................................... 4
Zones .................................................................................. 4
Burglary Protection ............................................................ 5
Security Codes.................................................................... 5
Fire Protection .................................................................... 6
Alarms ................................................................................. 6
Memory of Alarm................................................................. 6
Phone Access & Voice Response ...................................... 6
SECURITY CODES ............................................................... 27
General ............................................................................. 27
Babysitter Code ................................................................ 27
Duress Code ..................................................................... 27
Quick Arming .................................................................... 27
To Add or Change A User ................................................ 28
To Delete A User .............................................................. 28
TESTING THE SYSTEM........................................................ 29
TROUBLE CONDITIONS ...................................................... 31
FIRE ALARM SYSTEM ......................................................... 33
NFPA RECOMMENDATIONS ............................................... 34
EMERGENCY EVACUATION ............................................... 35
MAINTAINING YOUR SYSTEM ............................................ 36
QUICK GUIDE TO SYSTEM FUNCTIONS............................ 38
SUMMARY OF AUDIBLE NOTIFICATIONS......................... 40
GLOSSARY ........................................................................... 41
INSURANCE CREDIT REQUEST FORM.............................. 47
ENTRY/EXIT DELAYS ............................................................ 7
General Information ............................................................ 7
Exit Alarms .......................................................................... 8
COMMON ZONE OPERATION ............................................... 8
ABOUT THE KEYPADS .......................................................... 9
FUNCTIONS OF THE KEYPADS .......................................... 12
CHECKING FOR OPEN ZONES ........................................... 14
ARMING PERIMETER ONLY (STAY)................................... 15
ARMING PERIMETER ONLY (INSTANT)............................. 16
ARMING ALL PROTECTION (AWAY) .................................. 17
2-Partition Away Arming ................................................... 17
ARMING ALL PROTECTION (MAXIMUM) ........................... 19
DISARMING AND SILENCING ALARMS ............................. 20
Memory of Alarm............................................................... 20
BYPASSING PROTECTION ZONES .................................... 21
Quick Bypass .................................................................... 22
Displaying Bypassed Zones.............................................. 22
CHIME MODE ........................................................................ 23
PANIC KEYS ......................................................................... 24
– 3 –
SYSTEM OVERVIEW
Congratulations on your ownership of a First Alert Professional Partitioned Security System.
You've made a wise decision in choosing it, for it represents the latest in security protection
technology today.
General
This system offers you three forms of protection: burglary, fire and emergency. Your system
consists of at least one keypad which provides control of system operation, and includes
various sensors which provide perimeter and interior burglary protection, plus smoke or
combustion detectors designed to provide early warning in case of fire.
The system uses microcomputer technology to monitor all protection zones and system status
and provides appropriate information for display on the keypad(s) used with the system, and
initiates appropriate alarms. Your system may also have been programmed to automatically
transmit alarm or status messages over the phone lines to a central alarm monitoring station.
A Partitioned System
Simply stated, a partitioned system is a single physical alarm system that provides two
independent areas of protection intended for use by separate users. For the most part, you
need not know about other users and their structure in the system. However, when the system
is set up for 2-partition operation, you may see display messages from time to time which
indicate that the system is in use by another user; this is normal. A partitioned system may
also have a "common zone" area, which is an area shared by users of both partitions.
Refer to the COMMON ZONE OPERATION section for details on using this feature.
Zones
Your system's sensing devices have been assigned to various "zones." For example, the
sensing device on your Entry/Exit door may have been assigned to zone 01, sensing devices
on windows in the master bedroom to zone 02, and so on. These numbers will appear on the
display, along with a description for that zone (on Alpha display keypads only, if programmed)
when an alarm or trouble condition occurs.
– 4 –
SYSTEM OVERVIEW
Burglary Protection
Your system provides four modes of burglary protection: STAY, AWAY, INSTANT and
MAXIMUM, and allows you to BYPASS selected zones while leaving the rest of the system
armed. You must turn on or "arm" the burglary protection portion of your system before it will
sense burglary alarms. The system also provides a CHIME mode, for alerting users to the
opening of protected doors and windows while the system is disarmed. Refer to the other
sections of this manual for procedures for using these features.
The following table lists the four different arming modes and the results of each.
Features For Each Arming Mode
Arming
Mode
Exit Delay
Entry Delay
Perimeter Armed
Interior Armed
AWAY
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
No
STAY
INSTANT
MAXIMUM
No
No
Yes
Security Codes
Fire Protection
At the time of installation, you were assigned a personal four-digit security code, known only to
you. You must enter the security code when arming and disarming the system, and when
performing other system functions. As an additional safety feature, other users who do not have
a need to know your code can be assigned different security codes. Refer to the SECURITY
CODES section for procedures on adding security codes to the system.
The fire protection portion of your security system (if used) is always active and will sound an
alarm if a fire condition is detected. Refer to the FIRE ALARM SYSTEM section for important
information concerning fire protection, smoke detectors and planning emergency exit routes
from the premises.
– 5 –
SYSTEM OVERVIEW
Alarms
When an alarm occurs, both the keypad and external sounders sound, and the keypad displays
the zone(s) causing the alarm. If your system is connected to a central monitoring station, an
alarm message is also sent. To stop the alarm sounding, simply disarm the system.
Memory of Alarm
When an alarm condition occurs, the keypad displays the number(s) of the zone(s) that caused
the problem, and displays the type of alarm (ex. FIRE, ALARM). It remains displayed until it is
cleared by disarming the system (see DISARMING THE SYSTEM section).
Phone Access &
Voice Response
Capability
Your system may include a voice module that will permit you to access the system via a Touch-
tone phone, either on-premises or by call-in when away. The phone access feature will enable
you to do the following:
• Receive synthesized voice messages over the telephone regarding the status of the security
system.
• Arm and disarm the system and perform most function commands via the telephone, with
voice confirmation provided after each command entry.
Complete information regarding the use of this feature is provided in a separate manual entitled
PHONE ACCESS USER'S GUIDE, which accompanies the voice module.
Paging Feature
If the paging feature has been programmed for your system, your pager will respond to
certain conditions as they occur in your system, and display code numbers indicating the
type of condition that has occurred.
For detailed information, refer to PAGING FEATURE section later in this manual.
– 6 –
ENTRY/EXIT DELAYS
Your system has preset time delays, known as exit delay and entry delay. Whenever you arm
your system, exit delay gives you time to leave through the designated exit door without setting
off an alarm. Exit delay begins immediately after entering any arming command, and applies to
all modes of arming protection. Slow “beeps” will sound throughout the exit delay period, if
programmed.
General Information
Restarting Exit Delay While Armed: Your system may have been programmed to allow you
to restart the exit delay after the system has been armed in STAY mode. This is useful if you
wish to open the entry/exit door to let someone in after arming the system and avoids having to
disarm the system and then re-arm it again. If programmed, you can restart the exit delay by
pressing the [✱] key. Ask your installer if this feature is active for your system.
Exit Delay Restart
Active:
Entry Delays give you time to disarm the system when you re-enter through the designated
entrance door. But you must disarm the system before the entry delay period ends, or an alarm
will occur. The keypad beeps during the entry delay period, reminding you to disarm the
system. There are two entry delays (if programmed). The first is for your primary entrance and
the second may be used for a secondary entrance, where a longer delay is required to walk to
the keypad to disarm the system.
You can also arm the system with no entry delay at all by using either INSTANT or MAXIMUM
arming modes. These modes provide greater security while on the premises or while away for
extended periods of time.
See your installer for your delay times.
Partition 1
Partition 2
Exit Delay:
Exit Delay:
seconds
seconds
Entry Delay 1:
Entry Delay 2:
seconds
seconds
Entry Delay 1:
Entry Delay 2:
seconds
seconds
– 7 –
ENTRY/EXIT DELAYS
Exit Alarms
Whenever you arm the system, the exit delay begins. If an entry/exit door or interior zone is
faulted when the exit delay ends (e.g., exit door left open), the system sounds an alarm and
starts the entry delay timer. If you disarm the system before the entry delay ends, the alarm
sound stops and the message "CANCEL ALARM" or "CA" is displayed on the keypad, along
with a zone number indicating the faulted zone. No message is sent to the alarm monitoring
company. To clear the exit alarm condition, the open zone must be made intact; to clear the
display, enter your code plus OFF.
If you do not disarm the system before the entry delay ends, and an entry/exit door or interior
zone is still open, the alarm sound continues and an "exit alarm" message is sent to the alarm
monitoring company. The message ""EXIT ALARM" or "EA" is displayed on the keypad, along
with a zone number indicating the faulted zone. To stop the alarm, the system must be
disarmed (your code plus OFF); to clear the display, enter your code plus OFF a second time.
An “exit alarm” also results if an entry/exit door or interior zone is faulted within two minutes
after the end of the exit delay.
To minimize false alarms
sent to the alarm
monitoring company,
your system may have
been programmed for this
feature. Ask your installer
if "Exit Alarm" is active for
your system.
Exit Alarm Active
COMMON ZONE OPERATION
Your system may have been set up to use a common zone, which is an area shared by users of
both partitions, such as a foyer or lobby. If so, please note the following:
• The common zone will sound and report alarms only when both partitions are armed. If only
one partition is armed, the system ignores faults on the common zone.
Ask your
installer if a common
zone was assigned.
• Either partition may arm its system if the common zone is faulted, but once armed, the other
partition will not be able to arm unless the common zone is first bypassed or the fault is
corrected.
• If either partition is armed and the other is in chime mode, the common zone will not chime.
The common zone will chime if both partitions are disarmed and either is in chime mode.
• Faults on the common zone are displayed on keypads in both partitions.
• Either partition can clear and restore the common zone after an alarm.
– 8 –
ABOUT THE KEYPADS
Your keypads allow you to control all system functions. The keypads feature a telephone
style (digital) keypad and a Liquid Crystal Display (LCD) which shows the nature and location
of all occurrences.
General
The keypads also feature a built-in sounder which will sound during alarms and troubles. The
keypads also "beep" during certain system functions, such as during entry/exit delay times, in
CHIME mode, and when depressing any of the keys (to acknowledge the key press).
There are two basic types of keypads – a Fixed-Word keypad and an Alpha key-pad (both
described below). Fixed-Word and Alpha keypads are functionally the same, even though
they have different types of displays.
2-Line Alpha Keypad
1-Line Alpha Keypad
2-line Alpha keypads feature a 2-line, 32-character alphanumeric LCD which can display
system messages in friendly English. These keypads can also be programmed with custom
zone descriptors. The screen displays depicted throughout this manual are examples of
displays that would typically appear on a 2-line Alpha keypad.
1-line Alpha keypads feature a 16-character alphanumeric LCD which can display system
messages in friendly English. Messages are the same as those for 2-line Alpha keypads, but
are displayed one line at a time. To view the second line of the message, simply press the
#
key. To return to the first line, press the
#
again, or wait 3 seconds.
After pressing the key, wait at least 3 seconds before entering a command.
#
Fixed-Word Keypad
Fixed-Word keypads are functionally identical to Alpha keypads, but the LCD display uses
pre-designated words to identify the nature and location of occurrences.
Fixed-Word keypads are available with two styles of displays, “A” or “B” (see page 11),
depending on keypad used.
– 9 –
ABOUT THE KEYPADS
NO AC
First Alert ®
AWAY
BYPASS
NOT READY
CHIME BAT
ALARM STAY
AWAY
STAY
INSTANT
BYPASS
NO AC
CHIME
BAT
ARMED
CHECK INSTANT
FIRE
ALARM
CHECK
FIRE
READY
A
C
B
D
NOT READY
ARMED
READY
A
C
B
D
ARMED
READY
OFF
1
AWAY
2
STAY
3
OFF
1
AWAY
2
STAY
3
Professional
STAY
3
OFF
1
AWAY
2
MAXIMUM TEST BYPASS
4
6
5
TEST
5
BYPASS
6
MAXIMUM
4
TEST
5
BYPASS
6
MAXIMUM
4
INSTANT CODE CHIME
7
8
9
CODE
8
INSTANT
7
CHIME
9
CODE
8
INSTANT
7
CHIME
9
READY
0
#
READY
*
READY
First Alert
First Alert
PANIC
0
#
0
#
*
*
Professional
Professional
FA450KP/FA550KP Alpha Keypads
(single line/2-line)
FA210KP Fixed-Word Keypad
FA250KP Fixed-Word Keypad
– 10 –
ABOUT THE KEYPADS
Fixed-Word Keypad Displays
All burglary zones, interior & perimeter, are armed.
AWAY
STAY
Perimeter burglary zones, such as windows and doors
are armed.
NO AC
CHIME
BAT
AWAY
STAY
INSTANT
BYPASS
ALARM
CHECK
FIRE
INSTANT
BYPASS
Perimeter burglary zones armed and
delay is turned off.
entry
NOT READY
One or more burglary protection zones have
been bypassed.
STYLE A KEYPAD DISPLAY
NOT READY
Appears when burglary portion of the system is not
ready for arming (due to one or more open protection
zones).
NO AC
AWAY
BYPASS
NOT READY
ALARM STAY
CHIME BAT
CHECK INSTANT
READY
The burglary portion of the system is ready
to be armed.
FIRE
STYLE B KEYPAD DISPLAY
NO AC Appears when AC power has been cut off.
System is operating on backup battery power.
AC
Appears when AC power is present.
CHIME
BAT
Appears when the CHIME feature is ON.
Low battery condition in a wireless sensor (if zone number displayed) or low system battery (if no
zone number displayed).
ALARM
CHECK
Appears when an intrusion has been detected and the system is armed (also appears during a
fire alarm or audible emergency alarm). Accompanied by the protection zone in alarm.
Appears when a malfunction is discovered in the system at any time or if an open is detected in
a FIRE zone at any time or a fault in a DAY/NIGHT burglary zone during a disarmed period.
Accompanied by a display of zone number in trouble.
FIRE
Appears when a fire alarm is present. Accompanied by a display of the zone in alarm.
– 11 –
FUNCTIONS OF THE KEYPAD
SEE TYPICAL ALPHA KEYPAD ON NEXT PAGE
1. DISPLAY WINDOW. Alpha Keypad: A 2-line, 32-character
10. CHIME KEY: Turns CHIME mode on and off. When on, the
opening of windows or doors while the system is disarmed will
sound 3 beeps at the keypad(s).
Liquid Crystal Display (LCD). Displays protection zone
identification, system status, and messages.
Fixed-Word Keypad: Displays protection zone ID and system
status messages using pre-designated words.
✱
11.
12.
READY KEY: Displays all open protection zones.
2. OFF KEY: Disarms burglary portion of the system, silences
alarms and audible trouble indicators, and clears visual
display after problem's correction.
#
KEY: "Quick Arm" key permits ARMING of the system
without the use of a security code (if so programmed).
13. KEYS 0–9: Used to enter your security code(s). See Note on
3. AWAY KEY: Arms the entire burglary system, perimeter and
next page.
interior.
14. READY INDICATOR: (GREEN) Lit when the system is ready
to be armed (no faults present). While the system is disarmed,
this indicator will go on and off as protection zones are closed
and opened.
4. STAY KEY: Arms perimeter portion of burglary system only.
Interior protection is not armed, which allows movement within
premises without causing alarm.
5. MAXIMUM KEY: Arms in manner similar to AWAY mode, but
without the entry delay feature, thus providing maximum
protection. An alarm will occur immediately upon opening any
protection point, including the main door.
15. ARMED INDICATOR: (RED) Lit when the system has been
armed (STAY, AWAY, INSTANT or MAXIMUM).
16. INTERNAL SOUNDER: The built-in keypad sounder mimics
the alarm sounder during alarms, and will also "beep" during
certain system functions (see SUMMARY OF AUDIBLE/
VISUAL NOTIFICATION).
6. TEST KEY: Tests the system and alarm sounder if disarmed.
Refer to TESTING THE SYSTEM section for test procedures.
7. BYPASS KEY: Removes individual protection zones from
17. EMERGENCY (PANIC) KEYS:
being monitored by the system.
Individual keys A, B, and C (key D not used).
On some keypads, these keys are not present and certain key
pairs may be available for emergency functions.
8. INSTANT KEY: Arms in manner similar to STAY mode, but
without the entry delay feature. Entering via the entry/exit
door will cause an instant alarm.
For further information, refer to the PANIC KEYS section.
9. CODE KEY: Used to assign additional user codes for other
users of the system.
– 12 –
FUNCTIONS OF THE KEYPAD
1
•••• DISARMED ****
READY TO ARM
17
3
15
14
A
C
B
D
ARMED
READY
4
IMPORTANT!:
2
When entering codes and commands,
sequential key depressions must be made
within 2 seconds of one another. If 2
seconds elapses without a key depression,
the entry is aborted and must be repeated
from its beginning.
STAY
OFF
AWAY
6
1
2
3
TEST
5
BYPASS
MAXIMUM
4
5
6
7
CODE
8
INSTANT
7
CHIME
9
10
16
READY
First Alert
0
#
*
9
Professional
SHOWN WITH
FLIP-DOWN
KEY COVER
REMOVED
8
11
13
12
TYPICAL ALPHA KEYPAD
Fixed-Word Keypads are functionally similar,
except for screen displays (see page 10).
– 13 –
CHECKING FOR OPEN ZONES
Before arming your system, all protected doors, windows and other protection zones must be
closed or bypassed (see BYPASSING section). Otherwise the keypad will display a "Not
Ready" message. Using the READY key will display all zones that are faulted, making it easier
for you to secure any open zones.
Using the ✱
READY Key
To show faulted zones:
✱
DIS ARMED- PRESS
T O SH OW F AUL TS
Note: Keypads light a green READY indicator when system
is ready. If not lit, the system is not ready to be armed.
READY
PRESS THE READY KEY
1.
2.
✱
Do not enter the security code, but simply press the READY
key.
SECURE FAULTED ZONES
Typical fault display shows open zones. Secure or bypass
the zones displayed before arming the system.
F AULT 05 F RONT
UPS T AI RS BE DROOM
3.
SYSTEM CAN BE ARMED
DI S ARME D
RE ADY T O ARM
* * *
* * *
The "Ready" message will be displayed when all protection
zones have been either closed or bypassed.
You may now arm the system as usual.
– 14 –
ARMING PERIMETER ONLY
(With Entry Delay ON)
Using the
3
Use this key when you are staying home, but might expect someone to use the entrance door
later.
STAY key
When armed in STAY mode, the system will sound an alarm if a protected door or window is
opened, but you may otherwise move freely throughout the premises. Late arrivals can enter
through the entrance door without causing an alarm, but they must disarm the system within the
entry delay period or an alarm will occur.
Close all protected perimeter windows and doors before arming (see CHECKING FOR
OPEN ZONES section). The green READY indicator on the keypad should be lit if the system
is ready to be armed.
STAY
1.
+
3
ENTER SECURITY CODE THEN PRESS STAY
Example: 7 then press the STAY key.
(Security Code)
2
9
6
2.
LISTEN FOR 3 BEEPS
ARME D S T AY
* * *
* * *
The keypad will beep three times and will display the armed
STAY message. The red ARMED indicator also lights.
NOTE: If you wish to open the entry/exit door to let someone in after arming STAY, you can
re-start the exit delay at any time (if programmed) – simply press the [✱] key, and
then let that person in. This will avoid having to disarm the system and then re-arm it
again.
– 15 –
ARMING PERIMETER ONLY
(With Entry Delay OFF)
Using the
Use this key when you are staying home and do not expect anyone to use the entrance door.
7
INSTANT Key
When armed in INSTANT mode, the system will sound an alarm if a protected door or window
is opened, but you may otherwise move freely throughout the premises. The alarm will also
sound immediately if anyone opens the entrance door.
Close all protected perimeter windows and doors before arming (see CHECKING FOR
OPEN ZONES section). The green READY indicator on the keypad should be lit if the system
is ready to be armed.
INSTANT
1.
2.
+
7
ENTER SECURITY CODE THEN PRESS INSTANT
Example: 7 then press the INSTANT key.
(Security Code)
2
9
6
LISTEN FOR 3 BEEPS
The keypad will beep three times and will display the armed
INSTANT message. The red ARMED indicator also lights.
ARME D I NS T ANT
*
*
NOTE: If you wish to open the entry/exit door to let someone in after arming STAY, you can
re-start the exit delay at any time (if programmed) – simply press the [✱] key, and
then let that person in. This will avoid having to disarm the system and then re-arm it
again.
– 16 –
ARMING ALL PROTECTION
(With Entry Delay ON)
Using the
Use this key when no one will be staying on the premises.
2
AWAY Key
When armed in AWAY mode, the system will sound an alarm if a protected door or window is
opened, or if any movement is detected inside the premises. You may leave through the
entrance door during the exit delay period without causing an alarm. You may also re-enter
through the entrance door, but must disarm the system within the entry delay period or an alarm
will occur.
Close all protected perimeter windows and doors before arming (see CHECKING FOR
OPEN ZONES section). The green READY indicator on the keypad should be lit if the system is
ready to be armed.
AWAY
1.
2.
+
2
ENTER SECURITY CODE THEN PRESS AWAY
(Security Code)
Example: 7
2
9
6
then press the AWAY key.
LISTEN
ARME D AWAY
Y OU MAY E X I T NOW
* *
* *
The keypad will beep twice, or beep continuously if an exit
warning has been programmed for your system, and
displays the armed AWAY message. The red ARMED
indicator also lights.
The "You May Exit Now"
portion of the message
disappears when the exit
delay expires.
2-Partition AWAY
Arming
In a two-partition system, you can arm both partitions in the AWAY mode at the same time if the
same master code is assigned to both partitions. You can do this from either partition's keypad.
This procedure is not applicable to disarming or any other system function.
(Continued)
– 17 –
ARMING ALL PROTECTION
(With Entry Delay ON)
2-Partition AWAY
Arming
To arm both partitions, first make sure both partitions are READY TO ARM.
AWAY
AWAY
(Continued)
1.
+
2
+
2
ENTER MASTER CODE THEN PRESS AWAY
TWICE
(Master Code)
Example: 7
2
9
6 and press the AWAY key, then
press the AWAY key again.
The first press of AWAY arms the local partition, the
second press of AWAY arms the other (remote) partition.
The “Armed Away” display should appear, and remain
displayed (with exit warning beeps, if programmed)
throughout the exit delay period if both partitions were
successfully armed AWAY. The red ARMED indicator
should also light.
2.
ARME D AWAY
Y OU MAY E X I T NOW
* *
* *
The "You May Exit Now"
portion of the message
disappears when the exit
delay expires.
If the “READY TO ARM” message re-appears when the
second AWAY key press is made, both partitions have
failed to arm due to an open zone in the remote partition.
If the remote partition is not ready to arm, neither
partition will arm when using this particular
procedure.
– 18 –
ARMING ALL PROTECTION
(With Entry Delay OFF)
Using the
Key
Use this key when the premises will be vacant for extended periods of time such as vacations,
etc., or when no one will be moving through protected interior areas.
4
MAXIMUM
When armed in MAXIMUM mode, the system will sound an alarm if a protected door or window
is opened, or if any movement is detected inside the premises. You may leave through the
entrance door during the exit delay period without causing an alarm, but an alarm will be
sounded as soon as someone re-enters.
Close all protected perimeter windows and doors before arming (see CHECKING FOR
OPEN ZONES section). The green READY indicator on the keypad should be lit if the system is
ready to be armed.
MAXIMUM
1.
2.
+
4
ENTER SECURITY CODE THEN PRESS MAXIMUM
(Security Code)
Example: 7
2
9
6
then press the MAXIMUM key.
LISTEN
ARME D MAX I MUM
Y OU MAY E X I T NOW
*
*
The keypad will beep twice, or beep continuously if exit
warning has been programmed for your system, and will
display the armed MAXIMUM message (AWAY/INSTANT on
fixed-word keypads). The red ARMED indicator also lights.
The "You May Exit Now"
portion of the message
disappears when the exit
delay expires.
– 19 –
DISARMING AND SILENCING ALARMS
Using the
Use the OFF key to disarm the system and to silence alarm and trouble sounds. See
"SUMMARY OF AUDIBLE NOTIFICATIONS" section for information which will help you to
distinguish between FIRE and BURGLARY alarm sounds.
1
OFF Key
IMPORTANT: If you return and the main burglary sounder is on, DO NOT enter the premises,
but call the police from a nearby safe location. If you return after an alarm has occurred and
the main sounder has shut itself off, the keypad will beep rapidly upon entering, indicating that
an alarm has occurred during your absence and an intruder may still be on the premises.
LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location.
To disarm the system and silence burglary alarms:
OFF
1.
2.
+
1
ENTER SECURITY CODE, THEN PRESS OFF
Example: 7 then press the OFF key.
LISTEN FOR 1 BEEP
The “Ready” message will be displayed (if no alarms have
occurred while armed) and the keypad will beep once to
confirm that the system is disarmed.
(Security Code)
2
9
6
DI S ARME D
* * *
* * *
RE ADY T O ARM
Memory of Alarm
If an alarm occurs, the keypad displays the zone number (s) that caused the alarm and the type
of alarm. These messages remain displayed until cleared by a user. To clear the display, note
the zone number displayed and repeat step 1 above. If the “Ready“ message will not display,
go to the displayed zone and correct the fault (close windows, etc.). If the fault cannot be
corrected, notify your alarm company.
– 20 –
BYPASSING PROTECTION ZONES
This key is used when you want to arm your system with one or more zones intentionally
unprotected. Bypassed zones are unprotected and will not cause an alarm when violated while
your system is armed. All bypasses are removed when an OFF sequence (security code
plus OFF) is performed. Bypasses are also removed if the arming procedure that follows the
bypass command is not successful.
Using the
6
BYPASS Key
The system will not allow fire zones to be bypassed.
To bypass zones, the system must be disarmed first.
BYPASS
1.
2.
+
6
ENTER SECURITY CODE THEN PRESS BYPASS
Example: 7 then press the BYPASS key.
ENTER ZONE NUMBERS
(Security Code)
(Zone Numbers)
2
9
6
Enter the zone number(s) for the zones to be bypassed
(e.g., 01, 02, 03, etc.).
Important! All single-digit numbers must be preceded by a
zero (for example, enter 01 for zone 1).
3.
WAIT
BY PAS S 07 F RONT
The keypad will display the word BYPASS along with each
bypassed zone number. Wait for these zones to be
displayed, to be sure that intended zones are bypassed.
UPS T AI RS BE DROOM
Typical bypass message
4.
ARM AS USUAL
Arm the system as usual when the keypad displays the
"Ready ” message.
DI S ARME D BY PAS S
RE ADY T O ARM
(Continued)
– 21 –
BYPASSING PROTECTION ZONES (Continued)
Quick Bypass
Your system may allow you to easily bypass all open (faulted) zones without having to enter
zone numbers individually. Ask your installer if this feature is active.
All open (faulted) zones
All open zones, plus these zones as checked: 17
30
31
BYPASS
1.
2.
+
6
ENTER SECURITY CODE THEN PRESS BYPASS
Example: 7 then press the BYPASS key.
(Security Code)
2
9
6
WAIT. In a few moments, all open zones will be displayed
along with the word BYPASS. Wait for these zones to be
displayed before arming. Arming the system before zones
are displayed eliminates all bypasses.
BY PAS S 07 F RONT
UPS T AI RS BE DROOM
Typical bypass message
3.
ARM AS USUAL. Arm the system as usual when the
keypad displays the "Ready" message.
DI S ARME D BY PAS S
RE ADY T O ARM
Displaying Bypassed
Zones
Previously bypassed zones can be displayed only when the system is disarmed, and when the
“Bypass” message shown in step 3 above is displayed.
BYPASS
1.
2.
+
6
ENTER SECURITY CODE THEN PRESS BYPASS
(Security Code)
Example: 7
2
9
6
then press the BYPASS key.
WAIT
BY PAS S 07 F RONT
UPS T AI RS BE DROOM
Typical bypass message
In a few moments, all open zones will be sequentially
displayed along with the word BYPASS.
– 22 –
CHIME MODE
†
Using the
9
Key
Your system can be set to alert you to the opening of any door or window while it is disarmed
by using CHIME mode. When activated, three beeps will sound at the keypad whenever a
protected perimeter door or window is opened. Pressing the READY key will display the open
protection points.
†
or selected doors or
windows if chime-by-zone
feature is active. Ask
installer if this feature
applies to your system.
Note that the Chime mode can be activated only when the system is disarmed.
To turn Chime Mode on:
CHIME
1.
2.
+
9
ENTER SECURITY CODE THEN PRESS CHIME
(Security Code)
Example: 7
2
9
6
then press the CHIME key.
VIEW
DI S ARME D C HI ME
RE ADY T O ARM
The “Chime” message displays while chime mode is on.
To turn Chime Mode off:
CHIME
1.
+
9
ENTER SECURITY CODE THEN PRESS CHIME
(Security Code)
Example: 7
2
9
6
then press the CHIME key.
2.
VIEW
DI S ARME D
RE ADY T O ARM
* * *
* * *
The “Chime” message disappears from the display.
– 23 –
PANIC KEYS
(FOR MANUALLY ACTIVATING SILENT AND/OR AUDIBLE ALARMS)
Using
Panic Keys
Your system may have been programmed to use special keys to manually activate panic
functions. The functions that might be programmed are listed below. See your installer for the
function(s) that may have been programmed for your system.
Keys
Zone
95
99
Active Panic Function
A* or 1 and ✱
B* or ✱ and #
C* or 3 and #
Your installer
should note the
functions that
are active in
96
* Not present on certain Fixed-word keypads, which use paired keys to activate panic alarms (e.g., 1 and ✱, etc.).
your system.
If your keypad has lettered keys for panic functions, press the designated key and hold down
for at least 2 seconds to activate the panic function. To use a panic function initiated by paired
keys, simply press both keys of the assigned pair at the same time.
Types of Panic
Alarms
A silent emergency sends an alarm signal
to the alarm monitoring company,* but there
will be no audible alarms or visual displays.
An audible emergency sends an
emergency message to the alarm monitoring
company* and sounds a loud, steady alarm
at your keypad and at any external sounders
that may be connected (ALARM plus a zone
number is also displayed).
A personal emergency alarm sends an
emergency message to the alarm monitoring
company* and sounds at keypads, but not at
external sounders (ALARM plus a zone
number is also displayed).
* If your system is
connected to an
alarm monitoring
company.
A fire alarm sends a fire alarm message to
the alarm monitoring company* and uniquely
activates the keypad and any external
sounders (FIRE plus a zone number is also
displayed).
– 24 –
USING DEVICE COMMANDS
Your system may be set up so that certain lights or other devices can be turned on or off by
using the device command from the keypad. Ask your installer if this has been done in your
system. If programmed for your system, some devices may activate automatically upon certain
system conditions. In this case, the following commands can be used to override the device
activation. See your installer for a full explanation of this feature.
General Information
To activate devices
ENTER SECURITY CODE THEN PRESS
+ 7
#
+
7
+ DEVICE NUMBER
+
#
+
(Security Code)
Example: 7
device you wish to activate. See your installer for device numbers assigned for your system.
ENTER SECURITY CODE THEN PRESS + DEVICE NUMBER
(Device Number)
2
9
6 then press [#] , then press [7], then enter the number representing the
To de-activate
devices
#
+
8
+
#
+
8
+
(Security Code)
Example: 7
(Device Number)
2
9
6 then press [#] , then press [8], then enter the number representing the
device you wish to de-activate. See your installer for device numbers assigned for your system.
Device
Description
Device
Description
1
2
3
4
5
6
7
8
– 25 –
PAGING FEATURE
If the paging feature has been programmed for your system, a pager will respond to certain conditions as they
occur in your system by displaying a 10-digit code that will indicate the type of condition that has occurred. The
10-digit code will use the following format:
SSSS–EEE–NNN
SSSS will be your particular 4-digit subscriber No. (this same number will always appear at the beginning of the
display on your pager).
EEE will be a 3-digit number that describes the event that has occurred in your system (see explanation below).
NNN will be a 3-digit User or a zone number, depending on the type of event that has occurred.
The 3-digit Event Codes (EEE) that can be displayed are:
911 = Alarm (NNN that follows this code will be the zone number that has caused the alarm)
001 = Open, System disarmed (NNN that follows this code will be the User number)
002 = Close, System armed (NNN that follows this code will be the User number)
811 = Trouble (NNN that follows this code will be the zone number that has caused the trouble)
Example 1. Pager displays: 1 2 3 4 –9 1 1 –0 0 4
This indicates that your system (Subscriber No. 1234) is reporting an Alarm (911), due to zone 4 (004) being
faulted.
Example 2. Pager displays: 1 2 3 4 –0 0 1 –0 0 5
This indicates that your system (Subscriber No. 1234) is reporting an open/disarming (001) by User 5 (005).
– 26 –
SECURITY CODES
General Information
As an additional safety feature, other users who do not have a need to know your code can be
assigned different security codes. These secondary users are identified by "user numbers,"
which are selected when assigning a user's security code. You can assign up to 14 additional
user codes (user numbers 03-16), including the babysitter and duress codes. Note that the
master (primary) user of the system is the only one who can assign codes to secondary (or
temporary) users, and is user number 02; user number 01 is reserved for the installer of the
system.
All codes can be used interchangeably when performing system functions (a system armed with
one user's code can be disarmed by another user's code), with the exception of the babysitter
code described below.
Babysitter Code This code can be used to arm the system in assigned partitions, but cannot disarm the system
unless the system was armed with this code. This code is typically assigned to someone (such
as a babysitter) who has a need to arm/disarm the system only at certain times. The babysitter
code is assigned to user 15. The user of this code should not use the “Quick Arming” feature
described below.
Duress Code
This feature is intended for use when you are forced to disarm or arm the system under threat.
When used, the system will act normally, but can silently notify the alarm monitoring company
of your situation, if that service has been provided. Duress code is assigned to user 16.
Important: This code is useful only when the system is connected to a alarm monitoring
company.
Quick Arming
pressed in
key can be
Note that if "Quick Arming" was programmed by the installer, the
#
place of the security code when arming the system. The security code must
disarm the system, however.
always be used to
– 27 –
SECURITY CODES
Important: Temporary users of the system (e.g., babysitters, cleaning staff, etc.) should not be
shown how to use any system function they do not need to know, such as bypassing protection
zones for example.
To Add a User or
Change a User's
Code
Sequential key depressions for all steps in a procedure must be made within 2 seconds of one
another, or else the entire entry is aborted and must be repeated from its beginning (e.g.,
perform steps 1, 2, and 3 below with no delay between steps).
(Master Code)
CODE
1.
+
8
Enter your 4-digit master code then press CODE key.
2.
Enter 2-digit user number.
(User Number)
Enter the 2-digit User Number (03–16) for the user you are adding or changing.
3.
Enter 4-digit user's code.
(User's Code)
Enter the new 4-digit security code for that user.
To Delete a User
(Master Code)
CODE
+
8
Enter master code then press CODE key.
Enter 2-digit user number to be deleted.
2.
(User Number)
Enter the 2-digit User Number (03–16) for the user whose code you are deleting.
Wait (about 3 seconds) until the keypad beeps once before pressing any other
key. The code is automatically deleted.
To Change Your Master Code
Original Master Code
CODE
Master’s User No. New Master Code
New Master Code
Note that the new Master
Code must be entered twice.
+
8
+
0
2
+
+
– 28 –
TESTING THE SYSTEM
(TO BE CONDUCTED WEEKLY)
Using the
TEST Key
The TEST key puts your system into the Test mode, which allows each protection point to be
checked for proper operation. The keypad sounds a single beep every 40 seconds as a
reminder that the system is in the Test mode.
5
Note: An alarm message will not be sent to your alarm monitoring company during the
following tests.
DISARM THE SYSTEM
1.
DI S ARME D
RE ADY T O ARM
* * *
* * *
Disarm the system and close all protected windows,
doors, etc. The “Ready” message should be displayed and the
green READY indicator lit.
TEST
2.
3.
+
5
ENTER THE SECURITY CODE THEN PRESS TEST
(Security Code)
Example: 7
2
9
6
then press the TEST key.
LISTEN
The external sounder should sound for 2 seconds and then
turn off.
If the sounder does not sound, CALL FOR SERVICE
IMMEDIATELY.
4.
FAULT ZONES
Open each protected door and window in turn and listen for
three beeps from the keypad. Identification of each faulted
protection point should appear on the display. The display will
clear when the door or window is closed.
(Continued)
– 29 –
TESTING THE SYSTEM
Walk in front of any interior motion detectors (if used) and
listen for three beeps. The identification of the detector should
appear on the display when it is activated. The display will
clear when no motion is detected. Note that if wireless motion
detectors are used, there is a 3-minute delay between
activations. This is to conserve battery life.
To test all smoke detectors, follow the manufacturer's
instructions. The identification of each detector should appear
on the display when each is activated.
If a problem is experienced with any protection point (no
confirming sounds, no display), CALL FOR SERVICE
IMMEDIATELY.
When all protection points have been checked and are intact
(closed), there should be no zone identification numbers
displayed on the keypad
When testing is completed, exit the TEST mode by continuing
with step 5.
OFF
5.
+
1
EXIT TEST MODE
(Security Code)
Enter your security code and press the OFF key.
If the test mode is inadvertently left active, it automatically
turns off after 4 hours.
– 30 –
TROUBLE CONDITIONS
The word CHECK on the Keypad's display, accompanied by a rapid "beeping" at the Keypad,
indicates that there is a trouble condition in the system. The displays in parenthesis may appear
on non-alpha keypads when the associated trouble condition is present. To silence the
beeping sound for "check" conditions, press any key.
Typical "Check"
Displays
1. CHECK +
Zone No.
and/or
Indicates that a problem exists with those zone(s)*. First, determine
if the zone(s) displayed are intact and make them so if they are not.
If the zone uses a wireless detector, check that changes in the room
(moving furniture, televisions, etc.) are not blocking wireless signals
from the detector. If the problem has been corrected, the zone
*
Note that zone
number 9 represents
a problem with
wireless receivers or
other system devices,
which are not user
serviceable. CALL
FOR SERVICE
descriptor
(or CHECK
and Zone No. descriptor(s) and CHECK should disappear. If not, key an OFF
sequence (security code plus OFF) to clear the display. A CHECK
condition can also indicate a wiring problem. If the “check” display
persists, CALL FOR SERVICE IMMEDIATELY.
IMMEDIATELY.
Note that the system will not allow arming if a CHECK condition exists. To
arm the system with a CHECK condition present, you must first bypass
the zone(s) having the CHECK condition.
2. Telco Fault
If the telephone line monitor feature has been programmed for your
system, this display indicates that the telephone line has been
disconnected or cut. In some systems, this display will be accompanied by
a trouble sound from the keypad and the external sounder may be
activated. CONTACT YOUR SERVICE COMPANY IMMEDIATELY.
(or CHECK
and zone 94)
To silence the trouble sound, enter your security code plus OFF.
3. COMM.
Indicates that a failure has occurred in the telephone communication
portion of your system. CALL FOR SERVICE IMMEDIATELY.
FAILURE
(or FC)
– 31 –
TROUBLE CONDITIONS (Continued)
4. SYSTEM LO BAT
Indicates that a low system battery condition exists;
this is accompanied by a trouble sound* at the Keypad.
CALL FOR SERVICE AT ONCE.
* The beeping that
accompanies a low
battery display
(or BAT with no zone No.)
(items 4 & 5) can be
stopped by entering
an OFF sequence
(code + OFF).
5. LO BAT + zone descriptor
(or BAT with zone No.)
Indicates that a low battery condition exists in the
wireless transmitter** displayed; accompanied by
by a once-per-minute "beeping"* at the Keypad. Replace
the battery in the affected wireless transmitter as soon
as possible (see page 00), or CALL FOR SERVICE.
6. MODEM COMM
(or CC)
Indicates that the control is on-line with the central
station's remote computer. The control will not operate
while on-line. Wait a few minutes. The display should
disappear.
** Not all systems use
wireless
transmitters.
7. POWER indicator (if present)
is off. AC LOSS is displayed
(or NO AC)
The system is operating on battery power only. If only
some lights are out on the premises, check circuit
breakers and fuses and reset or replace as necessary.
CALL FOR SERVICE IMMEDIATELY if AC power
cannot be restored to the system.
8. Busy-Standby (or dI)
9. OPEN CIRCUIT (or OC )
10. Long Rng Trbl (or bF)
If this remains displayed for more than 1 minute, the
system is disabled. CALL FOR SERVICE IMMEDIATELY.
The keypad is not receiving signals from the control.
CALL FOR SERVICE IMMEDIATELY.
If programmed, your back-up Long Range Radio
communication has failed. CALL FOR SERVICE
IMMEDIATELY.
– 32 –
FIRE ALARM SYSTEM (IF INSTALLED)
General
Your fire alarm system (if installed) is active 24 hours a day, providing continuous protection. In
the event of an emergency, the installed smoke and heat detectors will automatically activate
you security system, triggering a loud, interrupted sound from the Keypad. An interrupted
sound will also be produced by optional exterior sounders. A FIRE message will appear at your
Keypad and remain on until you silence and clear the alarm display.
1. Should you become aware of a fire emergency before your detectors sense the problem,
go to your nearest Keypad and press the single panic key (or panic key pair) assigned as
FIRE emergency (if programmed by the installer) and hold down for at least 2 seconds. The
alarm will sound.
In Case Of Fire
2. Evacuate all occupants from the premises.
3. If flames and/or smoke are present, leave the premises and notify your local Fire
Department immediately.
4. If no flames or smoke are apparent, investigate the cause of the alarm. The zone descriptor
of the zone(s) in an alarm condition will appear at the Keypad.
Silencing A Fire Alarm
1. Silence the alarm by pressing the OFF key. To clear the alarm display, enter your code and
press the OFF key again.
2. If the Keypad indicates a trouble condition after the second OFF sequence, check that
smoke detectors are not responding to smoke or heat producing objects in their vicinity.
Should this be the case, eliminate the source of heat or smoke.
3. If this does not remedy the problem, there may still be smoke in the detector. Clear it by
fanning the detector for about 30 seconds.
4. When the problem has been corrected, clear the display by entering your code and
pressing the OFF key.
– 33 –
NATIONAL FIRE PROTECTION ASSN.
RECOMMENDATIONS ON SMOKE DETECTORS
With regard to the number and placement of
✪
▲
✪
✪
✪
✪
KITCHEN
▲
✪
KITCHEN
BDRM
DINING
BEDROOM
BEDROOM
smoke/heat detectors, we subscribe to the
recommendations contained in the National Fire
Protection Association's (NFPA) Standard #74
noted below.
TV ROOM
DINING
■
BDRM
LIVING ROOM
■
✪
✪
✪
■
✪
BEDROOM
BEDROOM
LIVING ROOM
Early warning fire detection is best achieved by
the installation of fire detection equipment in all
rooms and areas of the household as follows: A
smoke detector installed outside of each
separate sleeping area, in the immediate
vicinity of the bedrooms and on each additional
story of the family living unit, including
basements and excluding crawl spaces and
unfinished attics.
✪
▲
Smoke Detectors for Minimum Protection
Smoke Detectors for Additional Protection
Heat-Activated Detectors
■
✪
▲
■
BEDROOM
■
✪
BEDROOM
✪
BEDROOM
TO
BR
▲
■
▲
KTCHN
GARAGE
In addition, the NFPA recommends that you
install heat or smoke detectors in the living
room, dining room, bedroom(s), kitchen,
hallway(s), attic, furnace room, utility and
storage rooms, basements and attached
garages.
CLOSED
DOOR
LVNG RM
.
■
BASEMENT
– 34 –
EMERGENCY EVACUATION
Establish and regularly practice a plan of escape in the event of fire. The following steps
are recommended by the National Fire Protection Association:
Steps to Safety
1. Plan on your detector or your interior and/or exterior sounders warning all occupants.
CLOSET
BEDROOM
2. Determine two means of escape from each room. One path of escape should lead to the
door that permits normal exit from the building. The other may be a window, should your
path be unpassable. Station an escape ladder at such windows if there is a long drop to
the ground.
TH
BA
BEDROOM
BEDROOM
2ND FLOOR
3. Sketch a floor plan of the building. Show windows, doors, stairs and rooftops that can be
used to escape. Indicate escape routes for each room. Keep these routes free from
obstruction and post copies of the escape routes in every room.
KITCHEN
BACK DOOR
BEDROOM
TH
BA
4. Make sure that all bedroom doors are shut while you are asleep. This will prevent deadly
smoke from entering while you escape.
BEDROOM
1ST FLOOR
5. Try the door. If the door is hot, check your alternate escape route. If the door is cool,
open it cautiously. Be prepared to slam the door if smoke or heat rushes in.
•
6. In smoky areas, crawl close to floor, hold your breath, and/or cover mouth and nose with
a wet cloth.
•
7. Escape quickly; don't panic.
BACK
8. Establish a common meeting place outdoors, away from your premises, where everyone
can meet and then take steps to contact the authorities and account for those missing.
Choose someone to assure that nobody returns to the premises — many die going back.
See “How to Prepare a Fire Escape Plan”, published by First Alert Professional, for more
details.
•
FRONT
– 35 –
MAINTAINING YOUR SYSTEM
The components of your security system are designed to be as maintenance-free as possible.
However, to make sure that your system is in reliable working condition.
Taking Care of Your
System
1. Test your system weekly.
2. Test your system after any alarm occurs (see TESTING THE SYSTEM ).
Replacing
Batteries in
Wireless Sensors
Each wireless sensor in your system has a 9-volt or 3-volt battery. The system detects a low
battery in any wireless sensor, including smoke detectors, the optional personal emergency
transmitter, and the optional portable wireless keypad. (A low battery in a portable wireless
keypad is detected as soon as one of its keys is pressed, and the wired keypad will display
“00”.)
Wireless sensors
may not have
Alkaline batteries provide a minimum of 1 year of operation, and in most units and applications,
provide 2–4 years of service. 3-volt lithium batteries provide up to 4 or more years of operation.
Actual battery life will depend on the environment in which the sensor is used, the number of
signals that the transmitter in the sensor has had to send, and the specific type of sensor.
Factors such as humidity, high or low temperatures or large swings in temperature, may all lead
to the reduction of actual battery life in an installation.
been used in your
security system
If you have a low battery in a wireless sensor, a low battery message is displayed on the
keypad.
In addition, a battery-operated smoke detector with a low battery also emits a single "chirp"
sound approximately once every 20–30 seconds, identifying itself as the smoke detector with
the weak battery.
Note: The low battery message comes on as a warning that battery replacement in indicated
sensor(s) is due within 30 days. In the meantime, a sensor causing a low battery indication is
still fully operational.
Important: Use only batteries recommended by your installer as replacement.
– 36 –
MAINTAINING YOUR SYSTEM
Silencing Low Battery
Warning Tones at the
Keypad
You can silence the keypad’s warning tones by pressing the OFF key, but the keypad's low
battery message display will remain on as a reminder that you have a low battery condition in
one or more of your sensors. When you replace the weak battery with a fresh one, the sensor
will send a "good battery" signal to the control as soon as the sensor is activated
(opening/closing of door, window, etc.), causing the low battery display to turn off. If the sensor
is not activated, the display will automatically clear within approximately 1 hour.
Routine Care
• Treat the components of your security system as you would any other electrical equipment. Do
not slam sensor-protected doors or windows.
• Keep dust from accumulating on the keypad and all protective sensors, particularly on motion
sensors and smoke detectors.
• The keypad and sensors should be cleaned carefully with a dry soft cloth. Do not spray water
or any other fluid on the units.
– 37 –
QUICK GUIDE TO
SYSTEM FUNCTIONS
FUNCTION
PROCEDURE
COMMENTS
Check Zones
Press [✱]
Do this to view faulted zones when system not ready.
Arm System
Enter code
Do this to arm the system in the mode selected.
Press arming key desired
(AWAY, STAY, INSTANT,
MAXIMUM)
Disarm System
Bypass zones
Enter code
Press OFF [1]
Do this to disarm the system and silences alarms.
Enter code
Press BYPASS [6]
Do this to bypass protection zones. Bypassed zones are un-
protected and will not cause an alarm if violated.
Enter zone numbers to be
bypassed (use 2-digit entries)
Quick Bypass
Enter code
Do this to bypass all faulted zones automatically, if programmed.
Press BYPASS [6] and stopZones 17, 30 and 31 will also be bypassed, even if not
faulted (depending on programming, and if used in your
particular system).
Chime Mode ON Enter code
Press CHIME [9]
Chime Mode OFF Enter code
Press CHIME [9]
Do this to turn on chime mode. Keypad will sound if doors or
windows are violated while system disarmed.
Do this to turn chime mode off.
– 38 –
QUICK GUIDE TO
SYSTEM FUNCTIONS
(Continued)
FUNCTION
PROCEDURE
COMMENTS
Test Mode ON
Enter code
Press TEST [5]
Do this to enter test mode. Sounds alarm sounder and allows
sensors to be tested.
Test Mode OFF
Enter code
Press OFF [1]
Do this to turn test mode off. System returns to normal mode.
Add or Change
a User
Enter master code
Press CODE [8]
Enter user's 2-digit user No.
Enter code for that user
Do this to add or change a user code.
Delete a User
Enter master code
Press CODE [8]
Enter user number. to be
deleted
Do this to delete a user code from the system.
Do this to change the existing master code.
Change a Master
Code
Enter master code
Press CODE [8]
Press [0] + [2] (master user no.)
Enter new 4-digit master code
Enter new master code again
– 39 –
SUMMARY OF AUDIBLE NOTIFICATIONS
(ALPHA DISPLAY KEYPADS)
SOUND
CAUSE
FIRE ALARM
DISPLAY
LOUD, INTERRUPTED*
Keypad & External
LOUD, CONTINUOUS*
Keypad & External
FIRE is displayed; descriptor of zone in alarm is displayed.
BURGLARY/AUDIBLE
EMERGENCY ALARM
a. SYSTEM DISARM
b. SYSTEM ARMING ATTEMPT
WITH AN OPEN ZONE.
ALARM is displayed; descriptor of zone in alarm is also displayed.
ONE SHORT BEEP
(not repeated)
Keypad only
a. DISARMED/READY TO ARM is displayed.
b. The number and descriptor of the open protection zone is displayed.
c. Numbers and descriptors of the bypassed protection zones are displayed
(One beep is heard for each zone displayed). Subsequently, the following is
displayed: DISARMED BYPASS ...Ready to Arm
c. BYPASS VERIFY
ONE SHORT BEEP
(once every 40 seconds)
Keypad only
SYSTEM IS IN TEST MODE
Opened Zone identifications will appear.
ONE BEEP every 40 sec.
Keypad only
LOW BATTERY AT A TRANSMITTER LO BAT displayed with description of transmitter.
TWO SHORT BEEPS
Keypad only
ARM AWAY OR MAXIMUM
a. ARM STAY OR INSTANT
ARMED AWAY or ARMED MAXIMUM is displayed. Red ARMED indicator is
lit.
THREE SHORT BEEPS
Keypad only
a. ARMED STAY or ARMED INSTANT is displayed. Red ARMED
indicator is lit.
b. CHIME displayed, descriptor of open protection zone will be displayed if
the [✱] key is pressed.
b. ZONE OPENED WHILE
SYSTEM IS IN CHIME MODE.
RAPID BEEPING
Keypad only
a. TROUBLE
b. MEMORY OF ALARM
a. CHECK displayed. Descriptor of troubled protection zone is displayed.
b. FIRE or ALARM is displayed; descriptor of zone in alarm is displayed.
SLOW BEEPING
Keypad only
a. EXIT DELAY WARNING (if
programmed)
a. ARMED AWAY or ARMED MAXIMUM is displayed along with You May
Exit Now
b. ENTRY DELAY WARNING
b. DISARM SYSTEM OR ALARM WILL OCCUR is displayed.
the delay time without disarming causes alarm.
Exceeding
* If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.
– 40 –
GLOSSARY
The following terms are used throughout the manual.
ARM/DISARM: "Armed" simply means that the burglary portion of your system is turned ON and is in a state of
readiness. "Disarmed" means that the burglary system is turned OFF, and must be rearmed to
become operational. However, even in a "disarmed" state, "emergency" and "fire" portions of
your system are still operational.
KEYPAD: This is the area on your Keypad containing numbered pushbuttons similar to those on
telephones or calculators. These keys control the arming or disarming of the system, and
perform other functions which were previously described in this manual.
ZONE: A specific area of protection.
PARTITION: An independent group of zones that can be armed and disarmed without affecting other zones
or users.
BYPASS: To disarm a specific area of burglary protection while leaving other areas operational.
DELAY ZONE: An area of protection containing doors most frequently used to enter or exit (typically, a front
door, back door, or door from the garage into the building). The delay zone allows sufficient
time for authorized entry or exit without causing an alarm. Consult your installer for the entry
and exit delay times that have been set for your system during installation and record them in
the space provided in this manual on page 7.
DAY/NIGHT ZONE: An area of protection whose violation causes a trouble indication during the disarmed (DAY)
mode and an alarm during the armed (NIGHT) mode.
– 41 –
CANADIAN DEPARTMENT OF COMMUNICATIONS (DOC) STATEMENT
NOTICE
AVIS
The Canadian Department of Communications label identifies
certified equipment. This certification means that the equipment
meets certain telecommunications network protective, operational
and safety requirements. The Department does not guarantee the
equipment will operate to the user's satisfaction.
L'étiquette du ministère des Communications du Canada identifie le matériel
homologué. Cette étiquette certifie que le matériel est conforme à certaines
normes de protection, d'exploitation et de sécurité des réseaux de
télécommunications. Le ministère n'assure toutefois pas que le matériel
fonctionnera à la satisfaction de l'utilisateur.
Avant d'installer ce matériel, l'utilisateur doit s'assurer qu'il est permis de le
raccorder aux installations de l'entreprise locale de télécommunications. Le
matériel doit également être installé en suivant une méthode acceptée de
raccordement. Dans certains cas, les fils intérieurs de l'entreprise utilisés pour
un service individuel à la ligne unique peuvent être prolongés au moyen d'un
dispositif homologué de raccordement (cordon prolongateur téléphonique
interne). L'abonné ne doit pas oublier qu'il est possible que la conformité aux
conditions énoncées ci-dessus n'empèchet pas la dégradation du service dans
certaines situations. Actuellement, les entreprises de télécommunications ne
permettent pas que l'on raccorde leur matériel aux prises d'abonnés, sauf
dans les cas precis prévus par les tarifs particuliers de ces entreprises.
Les réparations du matériel homologué doivent être effectuées pas un centre
d'entretien canadien autorisé désigné par le fournisseur. La compagnie de
télécommunications peut demander à l'utilisateur de débrancher un appareil à
la suite de réparations ou de modifications effectuées par l'utilisateur ou à
cause de mauvais fonctionnement.
Pour sa propre protection, l'utilisateur doit s'assurer que tous les fils de mise
en terre de la source d'énergie électrique, des lignes téléphoniques de réseau
de conduites d'eau s'il y en a, soient raccordés ensemble. Cette précaution est
particulièrement importante dans les régions rurales.
Avertissement: L'utilisateur ne doit pas tenter de faire ces raccordements lui-
même; il doit avoir recours à un service d'inspection des installations
électriques, ou à un électricien, selon le cas.
Before installing this equipment, users should ensure that it is
permissible to be connected to the facilities of the local
telecommunications company. The equipment must also be
installed using an acceptable method of connection. In some
cases, the company's inside wiring associated with a single line
individual service may be extended by means of certified connector
assembly (telephone extension cord). The customer should be
aware that compliance with the above conditions may not prevent
degradation of service in some situations.
Repairs to certified equipment should be made by an authorized
Canadian maintenance facility designated by the supplier. Any
repairs or alterations made by the user to this equipment, or
equipment malfunctions, may give the telecommunications
company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical
ground connections of the power utility, telephone lines and internal
metallic water pipe system, if present, are connected together. This
precaution may be particularly important in rural areas.
Caution: User should not attempt to make such connections
themselves, but should contact the appropriate electric inspection
authority, or electrician, as appropriate.
The Load Number (LN) assigned to each terminal device denotes
the percentage of the total load to be connected to a telephone
loop which is used by the device, to prevent overloading. The
termination on a loop may consist of any combination of devices
subject only to the requirement that the total of the Load Numbers
of all the devices does not exceed 100.
L'indice de charge (IC) assigné à chaque dispositif terminal pour éviter toute
surcharge indique le pourcentage de la charge totale qui peut être raccordé à
un circuit téléphonique bouclé utilisé par ce dispositif. La terminaison du circuit
bouclé peut être constituée de n'importe quelle combinaison de dispositifs,
pourvu que la somme des indices de charge de l'ensemble des dispositifs ne
dépasse pas 100.
– 42 –
OWNER'S INSURANCE PREMIUM CREDIT REQUEST
This form should be completed and forwarded to your homeowner's insurance carrier for possible premium credit.
A. GENERAL INFORMATION:
Insured's Name and Address:
Insurance Company:
Policy No.
Both
First Alert Professional FA162C
Other _____________
Fire
Type of Alarm:
Burglary
Installed by:
Serviced by:
Name
Address
Name
Address
B. NOTIFIES (Insert B = Burglary, F = Fire)
Local Sounding Device
Police Dept.
Fire Dept.
Alarm Monitoring Company
Name:
Address:
Phone:
C. POWERED BY: A.C. With Rechargeable Power Supply
D. TESTING: Quarterly Monthly
Weekly
Other
(continued on other side)
– 43 –
OWNER'S INSURANCE PREMIUM CREDIT REQUEST (cont.)
E. SMOKE DETECTOR LOCATIONS
Furnace Room
Kitchen
Bedrooms
Attic
Hall
Basement
Living Room
Dining Room
F. BURGLARY DETECTING DEVICE LOCATIONS:
Front Door
Basement Door
Rear Door
All Exterior Doors
1st Floor Windows
All windows
I nterior locations
All Accessible Openings, Including Skylights, Air Conditioners and Vents
G. ADDITIONAL PERTINENT INFORMATION:
Signature:
Date:
– 44 –
UL NOTICE: This is a "GRADE A" system.
FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15 STATEMENT
This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following
statement for your information:
This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with
the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply
with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to
provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
• If using an indoor antenna, have a quality outdoor antenna installed.
• Reorient the receiving antenna until interference is reduced or eliminated.
• Move the receiver away from the control/communicator.
• Move the antenna leads away from any wire runs to the control/communicator.
• Plug the control/communicator into a different outlet so that it and the receiver are on different branch circuits.
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions.
The user or installer may find the following booklet prepared by the Federal Communications Commission helpful: "Interference
Handbook". This booklet is available from the U.S. Government Printing Office, Washington, DC 20402.
The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's
Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment.
IN THE EVENT OF TELEPHONE OPERATIONAL PROBLEMS
In the event of telephone operational problems, disconnect the control by removing the plug from the RJ31X (CA38A in Canada)
telephone wall jack. We recommend that your certified installer demonstrate disconnecting the phones on installation of the system.
Do not disconnect the phone connection inside the control/communicator. Doing so will result in the loss of your phone lines. If the
regular phone works correctly after the control/communicator has been disconnected from the phone lines, the control/communicator
has a problem and should be returned for repair. If upon disconnection of the control/communicator, there is still a problem on the
line, notify the telephone company that they have a problem and request prompt repair service. The user may not under any
circumstances (in or out of warranty) attempt any service or repairs to the system. It must be returned to the factory or an authorized
service agency for all repairs.
– 45 –
FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 NOTICE
This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a label that contains,
among other information, the FCC registration number and ringer equivalence number (REN) for this equipment. If
requested, this information must be provided to the telephone company.
This equipment uses the following jacks:
An RJ31X is used to connect this equipment to the telephone network.
The REN is used to determine the quantity of devices which may be connected to the telephone line. Excessive RENs
on the telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the
sum of the RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to the line,
as determined by the total RENs, contact the telephone company to determine the maximum REN for the calling area.
If this equipment causes harm to the telephone network, the telephone company will notify you in advance that
temporary discontinuance of service may be required. If advance notice is not practical, the telephone company will
notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you
believe necessary.
The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the
operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make
the necessary modifications in order to maintain uninterrupted service.
If trouble is experienced with this equipment, please contact the manufacturer for repair and warranty information. If the
trouble is causing harm to the telephone network, the telephone company may request you remove the equipment from
the network until the problem is resolved.
There are no user serviceable components in this product, and all necessary repairs must be made by the
manufacturer. Other repair methods may invalidate the FCC registration on this product.
This equipment cannot be used on telephone company-provided coin service. Connection to Party Line Service is
subject to state tariffs.
This equipment is hearing-aid compatible.
When programming or making test calls to an emergency number, briefly explain to the dispatcher the reason for the
call. Perform such activities in the off-peak hours; such as early morning or late evening.
– 46 –
WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM
While this system is an advanced design security system, it does not offer guaranteed protection against burglary or fire
or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn
for a variety of reasons. For example:
•
Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm
sensor or disconnect an alarm warning device.
•
Intrusion detectors (e.g. passive infrared detectors), smoke detectors, and many other sensing devices will not work
without power. Battery operated devices will not work without batteries, with dead batteries, or if the batteries are not
put in properly. Devices powered solely by AC will not work if their AC power supply is cut off for any reason,
however briefly.
•
Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarm receiver.
Even if the signal path has been recently checked during a weekly test, blockage can occur if a metal object is
moved into the path.
•
•
A user may not be able to reach a panic or emergency button quickly enough.
While smoke detectors have played a key role in reducing residential fire deaths in the United States, they may not
activate or provide early warning for a variety of reasons in as many as 35% of all fires, according to data published
by the Federal Emergency Management Agency. Some of the reasons smoke detectors used in conjunction with this
System may not work are as follows. Smoke detectors may have been improperly installed and positioned. Smoke
detectors may not sense fires that start where smoke cannot reach the detectors, such as in chimneys, in walls, or
roofs, or on the other side of closed doors. Smoke detectors also may not sense a fire on another level of a
residence or building. A second floor detector, for example, may not sense a first floor or basement fire. Moreover,
smoke detectors have sensing limitations. No smoke detector can sense every kind of fire every time. In general,
detectors may not always warn about fires caused by carelessness and safety hazards like smoking in bed, violent
explosions, escaping gas, improper storage of flammable materials, overloaded electrical circuits, children playing
with matches, or arson. Depending upon the nature of the fire and/or the locations of the smoke detectors, the
detector, even if it operates as anticipated, may not provide sufficient warning to allow all occupants to escape in
time to prevent injury or death.
– 47 –
WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM (continued)
•
•
Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their
installation manual. Passive Infrared Detectors do not provide volumetric area protection. They do create multiple
beams of protection, and intrusion can only be detected in unobstructed areas covered by those beams. They cannot
detect motion or intrusion that takes place behind walls, ceilings, floors, closed doors, glass partitions, glass doors, or
windows. Mechanical tampering, masking, painting or spraying of any material on the mirrors, windows or any part of
the optical system can reduce their detection ability. Passive Infrared Detectors sense changes in temperature;
however, as the ambient temperature of protected area approaches the temperature range of 90° to 105°F, the
detection performance can decrease.
Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are located on
the other side of closed or partly open doors. If warning devices sound on a different level of the residence from the
bedrooms, then they are less likely to waken or alert people inside the bedrooms. Even persons who are awake may
not hear the warning if the alarm is muffled from a stereo, radio, air conditioner or other appliance, or by passing
traffic. Finally, alarm warning devices, however loud, may not warn hearing-impaired people or waken deep sleepers.
•
•
Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of
service or temporarily out of service. Telephone lines are also subject to compromise by sophisticated intruders.
Even if the system responds to the emergency as intended, however, occupants may have insufficient time to protect
themselves from the emergency situation. In the case of a monitored alarm system, authorities may not respond
appropriately.
•
This equipment, like other electrical devices, is subject to component failure. Even though this equipment is designed
to last as long as 10 years, the electronic components could fail at any time.
The most common cause of an alarm system not functioning when an intrusion or fire occurs is inadequate
maintenance. This alarm system should be tested weekly to make sure all sensors and transmitters are working
properly.
Installing an alarm system may make one eligible for lower insurance rates, but an alarm system is not a substitute for
insurance. Homeowners, property owners and renters should continue to act prudently in protecting themselves and
continue to insure their lives and property.
We continue to develop new and improved protection devices. Users of alarm systems owe it to themselves and their
loved ones to learn about these developments.
– 48 –
SERVICING INFORMATION
Your local First Alert dealer is the person best qualified to service your alarm system.
Arranging some kind of regular service program with him is advisable.
Your local First Alert dealer is:
Name:_________________________________________________________________
Address: _______________________________________________________________
_______________________________________________________________
Phone: _______________________________
– 49 –
– INDEX –
1-Line Alpha Keypads ......................9
2-Line Alpha keypads .......................9
2-Partition AWAY Arming................17
Exit Alarm ......................................... 8
Fire .......... 4, 6, 11, 20, 21, 33, 35, 41
Fire Alarm .......................... 24, 33, 40
Fire Protection ..................... 6, 34, 35
Fire Emergency .............................. 33
Fire Escape .................................... 35
Fixed-Word Keypads ................. 9, 11
Quick Bypass............................ 22, 38
Quick Guide to System Functions .. 38
Replacing Batteries in Wireless
Sensors ....................................... 36
Ready Key ............................... 14, 33
AC Loss .........................................32
Add A User ...............................28, 39
Alpha Keypad .............................9, 13
Arming .........13, 15, 16, 17, 18, 19, 38
Audible Emergency ............11, 24, 40
Audible Notifications .......................40
Away ............5, 11, 12, 17, 26, 38, 40
Away Mode ..................12, 17, 26, 38
Security Codes .................... 5, 27, 28
Servicing Information ...................... 49
Silencing Alarms ...................... 20, 33
Silencing Low Battery Warning ...... 37
Silent Emergency .......................... 24
Sounder ....... 76, 9, 12, 20, 24, 29, 40
Special AWAY Arming .................... 17
Stay ............. 5, 11, 12, 15, 26, 38, 40
Stay Mode ................... 12, 15, 26, 38
System Lo Battery ......................... 32
Summary of Audible Notifications .. 40
Instant ............... 5, 11, 12, 16, 38, 40
Instant Mode ........................... 16, 38
Keypads .................. 9, 10, 11, 12, 13
Keyswitch ...................................... 26
Babysitter Code .............................27
Burglary Protection .................4, 5, 41
Bypass ...................12, 14, 21, 38, 41
Lo Bat ...................................... 32, 40
Low Battery ............ 11, 32,36, 37, 40
Maximum ............. 5, 7, 12, 19, 38, 40
Maximum Mode ....................... 19, 38
Memory Of Alarm .......... 6, 20, 26, 40
Modem Comm ............................... 32
Check .......................................11, 31
Chime ...............................5, 7, 23, 38
Chime Mode .........5, 9, 11, 23, 38, 40
Comm. Failure ................................32
Common Zone ..................................8
Delete A User ...........................28, 39
Telephone Problems ...................... 42
Temporary Users ........................... 28
Test Key ........................................ 29
Test Mode .................... 29, 30, 39, 40
Trouble Conditions .................. 31, 32
National Fire Protect Assn. ..... 34, 35
Not Ready ............. 11, 14, 18, 26, 38
Off Key .......................................... 20
Disarming .....................20, 26, 38, 41
Displaying Bypassed Zones............22
Duress Code ............................13, 27
Panic Functions ............................. 24
Panic Keys ......................... 13, 33, 24
Partitioned System .......................... 4
Personal Emergency ..................... 24
User Codes .............................. 12, 27
User Number ..................... 27, 38, 39
Emergency Evacuation ..................35
Entry Delay .............................5, 7, 11
Exit Delay ...5, 7, 8, 17, 18, 19, 40, 41
Voice Module ................................... 6
Wireless Sensor ...................... 11, 36
Zones .............................................. 4
Quick Arming ................................. 27
– 50 –
ONE YEAR LIMITED WARRANTY
Pittway Corporation, and its divisions, subsidiaries and affiliates ("Seller"), 165 Eileen Way, Syosset, New York 11791, warrants its
First Alert Professional security equipment (the "product") to be free from defects in materials and workmanship for one year from
date of original purchase, under normal use and service. Seller's obligation is limited to repairing or replacing, at its option, free of
charge for parts, labor, or transportation, any product proven to be defective in materials or workmanship under normal use and ser-
vice. Seller shall have no obligation under this warranty or otherwise if the product is altered or improperly repaired or serviced by
anyone other than the Seller. In case of defect, contact the security professional who installed and maintains your security equipment
or the Seller for product repair.
This one year Limited Warranty is in lieu of all other express warranties, obligations or liabilities. THERE ARE NO EXPRESS
WARRANTIES, WHICH EXTEND BEYOND THE FACE HEREOF. ANY IMPLIED WARRANTIES, OBLIGATIONS OR LIABILITIES
MADE BY SELLER IN CONNECTION WITH THIS PRODUCT, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY,
OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, ARE LIMITED IN DURATION TO A PERIOD OF ONE YEAR
FROM THE DATE OF ORIGINAL PURCHASE. ANY ACTION FOR BREACH OF ANY WARRANTY, INCLUDING BUT NOT
LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY, MUST BE BROUGHT WITHIN 12 MONTHS FROM DATE OF
ORIGINAL PURCHASE. IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL
DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF
LIABILITY WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE OR FAULT.
Some states do not allow limitation on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you.
Seller does not represent that the product may not be compromised or circumvented; that the product will prevent any personal injury
or property loss by burglary, robbery, fire or otherwise; or that the product will in all cases provide adequate warning or protection.
Buyer understands that a properly installed and maintained alarm may only reduce the risk of a burglary, robbery, fire or other events
occurring without providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal
injury or property loss as a result. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY,
PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING. HOWEVER, IF
SELLER IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING UNDER THIS
LIMITED WARRANTY OR OTHERWISE, REGARDLESS OF CAUSE OR ORIGIN, SELLER'S MAXIMUM LIABILITY SHALL NOT IN
ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT, WHICH SHALL BE THE COMPLETE AND EXCLUSIVE
REMEDY AGAINST SELLER. This warranty gives you specific legal rights, and you may also have other rights which vary from state
to state. No increase or alteration, written or verbal, to this warranty is authorized.
175 Eileen Way
Syosset, New York 11791
Copyright © 1997 PITTWAY CORPORATION
àN7527- 1V2! ä
N7527-1V2 Rev B 4/99
|