20" (50.8 cm) Freestanding Gas Range
PRODUCT MODEL NUMBERS
PRODUCT DIMENSIONS
TGP200VD
Gas supply: Provide a gas supply line of 3/4" (1.9 cm) rigid
pipe to the range location. A smaller size pipe on longer runs
may result in insufficient gas supply. Pipe joint compounds
that resist the action of LP gas must be used. Do not use
TEFLON®† tape. With LP gas, piping or tubing size can be 1/2"
(1.3 cm) minimum. Usually, LP gas suppliers determine the
size and materials used in the system.
If local codes permit, a new CSA design-certified, 4-5 ft
(122-152.4 cm) long, 1/2" (1.3 cm) or 3/4" (1.9 cm) I.D.,
flexible metal appliance connector may be used for connecting
range to the gas supply line.
42"
(106.7 cm)
36"
(91.5 cm)
A 1/2" (1.3 cm) male pipe thread is needed for connection to
the female pipe threads of the inlet to the appliance gas
pressure regulator.
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve.
This valve should be located in the same room but external to
the range. It should be in a location that allows ease of opening
and closing.
Electrical: A 120-volt, 60-Hz, AC-only, 15-amp, fused
electrical circuit is required. A time-delay fuse or circuit breaker
is also recommended. It is recommended that a separate
circuit serving only this range be provided.
24 1/2"
(62.2 cm)
19 1/2"
(49.5 cm)
Do not use an extension cord.
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and
Company.
CABINET OPENING DIMENSIONS
13" (33.0 cm) max.
upper cabinet depth
20" (50.8 cm) min.
For minimum
cabinet opening width
clearance to
top of cooktop,
see NOTE
Cabinet opening dimensions shown are for 25" (64 cm) countertop
depth, 24" (61 cm) base cabinet depth and 36" (91.4 cm) countertop
height.
20 1/8" (51.12 cm)
opening width
18" (45.7 cm)
min. clearance
upper side
cabinet to
3" (7.6 cm) min.
countertop space to
side wall or other
combustible material
If the cabinet depth is greater than 24" (61 cm), the oven frame must
extend beyond cabinet fronts by 1/2" (13 mm) minimum.
countertop
This shaded area
NOTE: 24" (61 cm) minimum when bottom of wood or metal cabinet is
protected by not less than 1/4" (0.64 cm) flame retardant millboard
covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm)
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
recommended for
installation
of gas pipe
10" (25.4 cm)
30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an unprotected wood or metal cabinet.
IMPORTANT: If installing a range hood or microwave hood
combination above the range, follow the range hood or microwave hood
combination installation instructions for dimensional clearances above
the cooktop surface.
5 1/2"
(14 cm)
4"
(10 cm)
2"
(5.1 cm)
2 1/2"
(6.4 cm)
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10173324