BATTERY REPLACEMENT
WARNING: Risk of Electrocution.
Before use, always test the Detector on
a known live circuit to verify proper
operation
SAFETY PRECAUTIONS
Owners’ Manual
1. Turn power OFF
2. Slide the pocket clip off (as shown) to
access batteries.
3. Replace the four LR44 batteries. The
negative sides of the batteries face in
the same direction, as shown. The
positive sides of the batteries face in the
opposite direction.
1. Improper use of this meter can cause
damage, shock, injury or death. Read
and understand this manual before
use.
2. Secure any covers or battery doors
before use.
3. Inspect the condition of the meter for
any damage before use.
4. Remove the batteries from the meter if
the meter is to be stored for long
periods.
CURRENT DETECTION
AC Voltage and Current
Detector
-
NOTE: There must be a load on the
circuit (current flow) for the
current detection function to
work.
Model 82147
+
DESCRIPTION
1. Current Sensor and LED
2. Current Detector “ON” LED
3. Current Detector Sensitivity adjustment
4. Current/Voltage/OFF function selector
switch
5. Voltage Sensor and LED
6. Voltage Detector “ON” LED
7. Voltage Detector Sensitivity adjustment
8. Audible beeper
1. Slide the Function switch to the Current
position.
ꢀ Safety
ꢀ Operation
ꢀ Español
CAUTION: Read,
understand and
follow Safety Rules
and Operating
Instructions in this
manual before using
this product.
2. The “CURRENT” LED will light. If the
LED is dim or does not light, replace
the batteries.
OPERATING INSTRUCTIONS
3. Set the Sensitivity adjustment to the
max position
WARNING: Risk of Electrocution.
Before use, always test the Detector on
a known live circuit to verify proper
operation
4. If detector begins to beep/flash, slowly
turn the sensitivity down until the
beep/flash stops.
ONE YEAR FULL WARRANTY
ONE YEAR FULL WARRANTY ON
CRAFTSMAN Detector
5. Move the detector current sensor near
the current carrying conductor until the
current tip flashes and beeper sounds.
VOLTAGE DETECTION
If this CRAFTSMAN Detector fails to
give complete satisfaction within one
year from the date of purchase,
RETURN IT TO THE NEAREST
SEARS STORE OR OTHER
CRAFTSMAN OUTLET IN THE
UNITED STATES, and Sears will
replace it, free of charge.
This warranty gives you specific legal
rights, and you may also have other
rights which vary from state to state.
Sears, Roebuck and Co., Dept.
817WA, Hoffman Estates, IL 60179
1. Slide the Function switch to the Voltage
position.
6. Slowly reduce the sensitivity and
reduce the distance between the
sensor and conductor to zero-in and
identify the conductor.
SPECIFICATIONS
2. The “VOLTAGE” LED will light. If the
LED is dim or does not light, replace
the batteries.
Voltage detection 12V to 600VAC
Current sensitivity 200mA (0.2A) AC at
0.2”
Audible indication Beeper (Voltage &
Current)
Visible indication Flashing LED (Voltage
& Current)
Frequency range 50 to 500Hz
Operating Temperature 14 to 122°F (-
10°C to 50°C)
3. Set the Sensitivity adjustment to max.
4. If the detector begins to beep/flash,
slowly turn the sensitivity down until
the beep/flash stops.
5. Touch the detector voltage sensor to
the hot conductor or insert into the hot
side of the electrical outlet.
For Customer Assistance Call 9am -
5pm (ET)
Monday through Friday 1-888-326-1006
6. If AC voltage is present, the detector
light will flash and the audible beeper
will sound.
Operating Humidity < 80% RH
Altitude
< 2000m
Power supply
Weight
(4) LR44 batteries
2.1 oz. (60g)
7. Adjust the sensitivity as needed to
zero-in and identify the live conductor.
WARNING: USE EXTREME CAUTION
IN THE USE OF THIS DEVICE.
Improper use of this device can result
in injury or death. Follow all
safeguards suggested in this manual
in addition to the normal safety
precautions used in working with
electrical circuits. DO NOT service
this device if you are not qualified to
do so.
Dimensions
7.6 x 1.2 x 0.9”
(192x31x24mm)
Category III 600V
Indoor use
© Sears, Roebuck and Co.,
Hoffman Estates, IL 60179 U.S.A.
IEC 1010
061906
UL LISTED
The UL mark does not indicate that this product has
been evaluated for the accuracy of its readings.
|