Cornelius Beverage Dispenser 230 VAC User Manual

IMI CORNELIUS INC g One Cornelius Place g Anoka, MN 55303-6234  
Telephone (800) 238-3600  
Facsimile (612) 422-3246  
INSTALLATION INSTRUCTIONS  
VOLTAGE PROTECTOR MODULE KIT (P/N 440000401)  
ON  
230 VAC, 50Hz VANTAGE POST-MIX DISPENSERS  
Read and understand these instructions thoroughly before installing this Voltage Protector Module Kit. Purpose  
of the Voltage Protector Module is to shut the Dispenser down should a too low or a too high power voltage con-  
dition occur. Retain these instructions as part of your equipment manual.  
LOOSE-SHIPPED PARTS  
Note: Only qualified personnel should install this Kit.  
Unpack and inspect kit. Make sure items are present and in good condition.  
Table 1. Loose-Shipped Parts  
Item  
No.  
Part No.  
Name  
Qty  
1
1
XXXXXXXXX Voltage Protector Module  
2
560003334  
560003335  
560003336  
325282000  
Electrical Wire (brown)  
Electrical Wire (black)  
Electrical Wire (blue)  
1
3
1
4
1
5
Screw, Hex Washer Hd; Self-Drilling, No. 8–18 Thread by 1/2-inch Long  
4
KIT INSTALLATION  
WARNING: To avoid possible fatal electrical shock or serious injury to Installer, make sure  
Dispenser is disconneced from power source before attempting to install this kit.  
1. Disconnect electrical power from the Dispenser  
2. Remove screw securing the hood, then lift hood straight up off the Dispenser.  
3. Remove two screws securing the electrical control box cover, then remove cover for access to the control  
board.  
NOTE: It may be necessary to relocate the transformer to make room for installation of the VOLTAGE  
PROTECTOR MODULE (item 1) on the refrigeration deck as shown in Figure 1.  
4. Remove two screws securing the transformer to the refrigeration deck. Discard the two transformer retain-  
ing screws.  
July 21, 1998  
569000242  
EIMI Cornelius Inc; 1998  
OBSOLETE  
 
PRIMARY  
TERMINALS  
(HIGH VOLTAGE)  
AGITATOR MOTOR  
VOLTAGE PROTECTOR  
MODULE  
TRANSFORMER  
ELECTRICAL  
CONTROL BOX  
SECONDARY  
TERMINALS  
(24 VAC)  
FIGURE 1. TRANSFORMER/VOLTAGE PROTECTOR MODULE LOCATION  
5. Place the transformer and the VOLTAGE PROTECTOR MODULE (item 1) on the refrigeration deck in  
approximate locations as shown in Figure 1.  
6. Using the transformer and the VOLTAGE PROTECTOR MODULE (item 1) as templates, mark their mount-  
ing holes locations on the refrigeration deck.  
7. Using a 9/64 drill bit, center punch and drill the four mounting holes in the refrigeration deck.  
8. Install transformer and VOLTAGE PROTECTOR MODULE (item 1) on the refrigeration deck and secure  
with SCREWS (item 5).  
NOTE: Refer to Figure 2 (WIRING DIAGRAM) when making wiring connections between the Voltage  
Protector Module and the Control Board.  
9. Connect one end of the black ELECTRICAL WIRE (item 3) to LIVE OUTterminal on the Voltage Protec-  
tor Module.  
10. Disconnect Compressor black electrical wire from SW. COMPterminal on the Control Board.  
11. Connect other end of the black electrical wire, connected to LIVE OUTterminal on the Voltage Protector  
Module, to compressor black electrical wire disconnected from the control board SW. COMPterminal in  
preceding step 10.  
12. Connect one end of the blue ELECTRICAL WIRE (item 4) to LIVE INterminal on the Voltage Protector  
Module.  
13. Connect other end of the blue ELECTRICAL WIRE (item 4) to SW. COMPterminal on control board  
where compressor electrical wire was disconnected from in step 10 preceding.  
14. Connect one end of the brown ELECTRICAL WIRE (item 2) to L2terminal on the control board. This con-  
nection consist of two electrical wires connected to L2terminal with a piggy-back push on terminal.  
15. Connect other end of the brown ELECTRICAL WIRE (item 2) to NEUTRALterminal on the Voltage Pro-  
tector Module.  
16. Install control box cover and secure with two screws.  
17. Connect electrical power to the Dispenser. Check Dispenser for proper operation. When refrigeration com-  
pressor is operating, green light on the Voltage Protector Module will be illuminated. When refrigeration  
compressor is not operating, the yellow light on the Voltage Protector Module will be illuminated.  
18. Install hood on Dispenser and secure with screw.  
569000242  
2
 
ITEM 1  
ITEM 3  
GREEN  
INDICATOR  
LIGHT  
PIGGY BACK  
TERMINAL CONNECTION  
ITEM 4  
YELLOW  
INDICATOR  
LIGHT  
CONNECTOR  
ITEM 2  
FIGURE 2. WIRING DIAGRAM  
 

Coleman Camper 2000004679 User Manual
Conair Automobile Accessories HMC1 User Manual
Delta Electronics Power Supply SIQ124R User Manual
DigiPower Video Gaming Accessories TC U100 User Manual
Dixon Lawn Mower ZTR 428 User Manual
Eastman Outdoors Blender Reveo Food Processor Tumbler User Manual
Flip Video Camcorder Accessories 3250 00176 A User Manual
Fortinet Network Hardware Fortianalyzer 4000B User Manual
Frigidaire Cooktop FGGC3045K User Manual
Gefen Cable Box EXT DVI 2 MDP User Manual