ROADWAY
150-400W
OVY LOW-PROFILE DROP PRISMATIC
MH/HPS/MERCURY
ROADWAY LUMINAIRE
30" [762mm]
9 3/4"
[248mm]
NOTE: In select distributions only.
16 15/16" [430mm]
STREETWORKS™
HOUSING
ORDERING INFORMATION
Die-cast aluminum housing with
stainless steel bail latch. Standard
grey polyester powder coat finish.
Other finish colors available.
Consult your Streetworks
SAMPLE NUMBER: OVY15SWW2D4
PRODUCT
FAMILY
OVY
LAMP WATTAGE
15=50W 1
20=200W
LAMP TYPE 3
S=High
Pressure
BALLAST TYPE 3
C=CWI
M=Mag. Reg.
W=CWA
R=Reac./NPF
P=Hi. Reac./HPF
H=Reac./HPF
N=Hi. Reac./NPF
K=10KV CWA
VOLTAGE3
2=120V
0=208V
4=240V
7=277V
8=480V
9=347V
DISTRIBUTION 5
2=Type II
3=Type III
4=Type IV
OPTIONS +
ACCESSORIES
(See Below)
CUTOFF
D=MCO
E=MSCO
J=LNCO
Representative. Optional NEMA
twistlock photocontrol receptacle
also available.
25=250W
31=310W
Sodium
V=Mercury 4
M=Metal Halide
40=400W 2
24=250/400
wired 250W 2
42=400/250W
wired 400W 2
SOCKET
F=120/240 wired 120V
P=240 w/PCR wired 120V
W=Multi-Tap wired 120V
N=Multi-Tap wired 277V
V=Multi-Tap wired 240V
Adjustable mogul-base porcelain
socket.
DOOR
Die-cast aluminum door frame with
integral hinges for hands free
installation, relamping and
maintenance. ANSI wattage/source
label.
OPTIONS + ACCESSORIES [ Must be listed in the order shown and separated by a dash]
OPTIONS (add as suffix)
1=Single Fuse, Internally Mounted (120 or 277V)
2=Double Fuse, Internally Mounted (208, 240, or 480V)
4=Photocontrol Receptacle
WH=White
BK=Black
BZ=Bronze
E=150W/100V/HPS Ballast
H=Plug-in Starter Receptacle
K=Level Indicator
ACCESSORIES (order separately)
RA1003=Cutoff Visor
LENS
OA/RA1013=Photocontrol Shorting Cap
OA/RA1014=120V Photocontrol
OA/RA1016=105V-285V Photocontrol
OA/RA1027=480V Photocontrol
OA1028=Field Installed PCR Kit
OA1215=TufGuard Vandal Shield
Removable borosilicate glass
refractor for use with High Pressure
Sodium, Metal Halide and Mercury
lamp sources. Low profile glass
provides 65% less glare than typical
drop lens reflectors.
OPTICAL ASSEMBLY
The optical system is a
hydroformed anodized aluminum
reflector with a Dacron polyester
filter.
L=Lamp
M=MOV Lightning Surge Protector 6
T=Swing-down Ballast Bridge
U=UL/CSA Listed
BALLAST ASSEMBLY
Hard mounted ballast with
encapsulated starter for protection
from environmental abuse.
Standard two position tunnel type
compression terminal block.
Optional swing-down ballast bridge
also available (Not available for 3G
applications).
OPTIONAL COLORS [ Standard color is grey, other finish colors available. Consult your Cooper Lighting representative]
WH
BK
BZ
White
Black
Bronze
MOUNTING
Two-bolt/one bracket slipfitter with
cast-in pipe stop and leveling steps.
Fixed-in-place birdguard seals
around 1 1/4" or 2" mounting arms.
(Birdguard not needed for 2" arm.)
EPA:
Effective Projective Area: .51
SHIPPING DATA
Approximate Net Weight:
33 lbs. (15 kgs.)
NOTE: 1 150W units are for S55 lamp. 2 400W Metal Halide requires ED28 lamp. 3 Refer to technical section for lamp/ballast/voltage compatibility. 4 Not available in 400W. 5 Other distributions & cutoffs available. Consult your
Streetworks Representative. 6 MOV option is not available for any system requiring a three position terminal block (Example—240V with PCR wired 120V). In order for MOV option to function center terminal of three
position terminal block must be connected to “Earth” ground.
124 STREETWORKS Outdoor Lighting Solutions
Cooper Lighting
|