Connerton Co Oven RLRB A User Manual

Installation,  
Operation &  
Maintenance  
Instructions  
Fine Cooking Equipment For Over 70 Years  
RLRB-A BUDGET SERIES CHAR BROILERS  
For Your Safety  
Warning!  
Do NOT store or use gasoline or  
other flammable vapors and liquids  
in the vicinity of this, or any other  
equipment.  
Improper installation, adjustment, alteration, service or  
maintenance can cause property damage, injury or death.  
Read the installation, operation and maintenance  
instructions thoroughly before installing or servicing this  
equipment.  
To Purchaser  
After installation of your broiler, immediately contact your local gas supplier to obtain information  
in the event the user of your equipment smells gas. This information must be posted in a  
prominent location.  
To User  
RETAIN THIS MANUAL FOR FUTURE USE  
Upon receipt of this broiler, inspect it thoroughly for any damage which may have occurred  
during shipment. If damage is observed, contact the delivery agency immediately.  
1. Preparation For Installation: Safe and satisfactory operation of the broiler depends, to a great extent,  
upon it’s proper installation. It should be installed in accordance with the National Fuel Gas Code  
Z223.1, these instructions, and applicable State and Local Codes.  
Installation must be made by a licensed plumber.  
A gas pressure regulator is supplied with your broiler. The regulator must be installed before  
connecting broiler to gas supply line. Please note: air vent can plug with grease, thereby shutting gas  
supply off. Install regulator in a drip-free area.  
The broiler and it’s individual shutoff valve must be disconnected from the gas supply piping system  
during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45 kPa).  
The broiler must be isolated from the gas supply piping system by closing it’s individual manual  
shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or  
less than 1/2 psig (3.45 kPa).  
For radiant-type broilers, radiant tabs drop into holes in the firebox. For lava rock-type broilers, lava  
rock grates rest on front and rear support surface of the firebox. Disburse lava rock evenly in one layer  
ONLY throughout the firebox area, leaving air spaces. For both types, top grates are notched to secure  
grate to lip of firebox gutter.  
The Connerton Company  
1131 E. Wakeham Avenue, Santa Ana, CA 92705-4145  
Telephone: (714) 547-9218 Fax: (714) 547-1969  
 
6
10  
5
11  
7
2
9
8
16  
17  
1
14  
13  
12  
3
15  
4
RLRB-A BUDGET SERIES CHAR BROILERS  
1. 65-400-xx  
2. 60-475-xx  
3. 60-425-xx  
4. 65-450-xx  
5. 60-100-02  
6. 60-100-01  
7 60-150-00  
8. 60-200-01  
60-200-02  
Body  
Firebox  
Front Panel  
Grease Pan  
Waffle Grate  
Top Grate  
Burner  
Orifice Hood - Natural  
Orifice Hood - Propane  
9. 00-675-00  
10. 60-125-00  
11. 60-350-00  
12. 60-300-xx  
13. 00-225-00  
14. 00-250-00  
15. 00-500-00  
16. 00-275-01  
00-275-02  
Air Shutter  
Radiant  
Pilot w/tubing  
Gas Manifold  
Pilot Valve  
Manual Control Valve  
Chrome Knob  
Regulator - Natural  
Regulator - Propane  
Lava Rock  
17. 00-175-00  
*** For part numbers ending in xx, specify model size (ie: 65-400-37 for a RLRB-23-37R/L)  
*** IMPORTANT: Lava Rock NOT to be used with Radiants (10)  
 
TROUBLESHOOTING GUIDE  
Condition  
Probable Cause  
Solution  
Small/no burner flame  
Regulator failure  
Unplug regulator vent hole or  
replace regulator.  
Plugged orifice hood  
Plugged burner port  
Unplug hole or replace orifice.  
Unplug burner port(s).  
Small/no pilot flame  
Yellow burner flame  
Pilot valve setting  
Plugged pilot tip  
Adjust flame height.  
Unplug pilot ports.  
Improper air shutter setting  
Increase air shutter setting until  
flame is blue.  
Enlarged orifice hood  
Replace w/correct orifice.  
Flame lifts off burner  
Too hot/cold  
Improper air shutter setting  
Decrease air shutter setting  
until flame sits on burner.  
Plugged orifice hood  
Improper level setting  
Improper control setting  
Unplug orifice hole or replace orifice.  
Adjust level w/feet or shims.  
Adjust control setting or replace  
control.  
Improper level setting  
Adjust level w/feet or shims.  
Too much/little lava rock  
Add/remove lava rock to proper  
level; single layer only with air  
space.  
LIMITED WARRANTY  
The Connerton Company warrants to the original user for a period of one year from date of installation, not  
to exceed 18 months from date of shipment by Connerton, that the equipment manufactured is free from  
defects in material or workmanship.  
Our obligation under this warranty shall be limited to furnishing without charge any part of said product  
which, upon examination by The Connerton Company shall prove to be defective. Parts wear is not  
considered a defect. The Connerton Company will not be responsible for labor or transportation charges  
incidental to the replacement of same.  
The Connerton Company assumes no responsibility for failure of the equipment to operate properly due to  
improper installation or operation. This warranty applies to all equipment that has been unaltered, properly  
installed and maintained in accordance with national and local codes and in accordance with the  
installation and operating instructions included with this equipment.  
This warranty does not extend to normal maintenance items, including but not limited to, air and gas  
adjustments and adjustments to pilot flames. Proper installation, adjustments, and initial checkout is the  
responsibility of the dealer, the owner-user or installer and not that of The Connerton Company.  
Exceptions to warranty:  
1) Lower lava rock broiler grates.  
Please fill out and refer to the following when contacting the factory:  
Model # RLRB-23-  
-A Serial#  
Gas Type:  
Purchase Date:  
 

Cranium Games Jungle Adventure User Manual
Cub Cadet Lawn Mower 108 User Manual
Cypress Computer Hardware CY8C20396 User Manual
Dimplex Indoor Fireplace DF3015 User Manual
Dukane Projector 8970 User Manual
DVS Car Stereo System DSV 811 User Manual
Eaton Electrical Power Supply 10000LXL User Manual
Electro Voice Microphone PL80a User Manual
Extron electronic Switch VSW 2VGA A User Manual
Frigidaire Cooktop 318200650 User Manual