Installation,
Operation &
Maintenance
Instructions
Fine Cooking Equipment For Over 70 Years
RLRB-A BUDGET SERIES CHAR BROILERS
For Your Safety
Warning!
Do NOT store or use gasoline or
other flammable vapors and liquids
in the vicinity of this, or any other
equipment.
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, injury or death.
Read the installation, operation and maintenance
instructions thoroughly before installing or servicing this
equipment.
To Purchaser
After installation of your broiler, immediately contact your local gas supplier to obtain information
in the event the user of your equipment smells gas. This information must be posted in a
prominent location.
To User
RETAIN THIS MANUAL FOR FUTURE USE
Upon receipt of this broiler, inspect it thoroughly for any damage which may have occurred
during shipment. If damage is observed, contact the delivery agency immediately.
1. Preparation For Installation: Safe and satisfactory operation of the broiler depends, to a great extent,
upon it’s proper installation. It should be installed in accordance with the National Fuel Gas Code
Z223.1, these instructions, and applicable State and Local Codes.
Installation must be made by a licensed plumber.
A gas pressure regulator is supplied with your broiler. The regulator must be installed before
connecting broiler to gas supply line. Please note: air vent can plug with grease, thereby shutting gas
supply off. Install regulator in a drip-free area.
The broiler and it’s individual shutoff valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45 kPa).
The broiler must be isolated from the gas supply piping system by closing it’s individual manual
shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or
less than 1/2 psig (3.45 kPa).
For radiant-type broilers, radiant tabs drop into holes in the firebox. For lava rock-type broilers, lava
rock grates rest on front and rear support surface of the firebox. Disburse lava rock evenly in one layer
ONLY throughout the firebox area, leaving air spaces. For both types, top grates are notched to secure
grate to lip of firebox gutter.
The Connerton Company
1131 E. Wakeham Avenue, Santa Ana, CA 92705-4145
Telephone: (714) 547-9218 Fax: (714) 547-1969
6
10
5
11
7
2
9
8
16
17
1
14
13
12
3
15
4
RLRB-A BUDGET SERIES CHAR BROILERS
1. 65-400-xx
2. 60-475-xx
3. 60-425-xx
4. 65-450-xx
5. 60-100-02
6. 60-100-01
7 60-150-00
8. 60-200-01
60-200-02
Body
Firebox
Front Panel
Grease Pan
Waffle Grate
Top Grate
Burner
Orifice Hood - Natural
Orifice Hood - Propane
9. 00-675-00
10. 60-125-00
11. 60-350-00
12. 60-300-xx
13. 00-225-00
14. 00-250-00
15. 00-500-00
16. 00-275-01
00-275-02
Air Shutter
Radiant
Pilot w/tubing
Gas Manifold
Pilot Valve
Manual Control Valve
Chrome Knob
Regulator - Natural
Regulator - Propane
Lava Rock
17. 00-175-00
*** For part numbers ending in xx, specify model size (ie: 65-400-37 for a RLRB-23-37R/L)
*** IMPORTANT: Lava Rock NOT to be used with Radiants (10)
TROUBLESHOOTING GUIDE
Condition
Probable Cause
Solution
Small/no burner flame
Regulator failure
Unplug regulator vent hole or
replace regulator.
Plugged orifice hood
Plugged burner port
Unplug hole or replace orifice.
Unplug burner port(s).
Small/no pilot flame
Yellow burner flame
Pilot valve setting
Plugged pilot tip
Adjust flame height.
Unplug pilot ports.
Improper air shutter setting
Increase air shutter setting until
flame is blue.
Enlarged orifice hood
Replace w/correct orifice.
Flame lifts off burner
Too hot/cold
Improper air shutter setting
Decrease air shutter setting
until flame sits on burner.
Plugged orifice hood
Improper level setting
Improper control setting
Unplug orifice hole or replace orifice.
Adjust level w/feet or shims.
Adjust control setting or replace
control.
Improper level setting
Adjust level w/feet or shims.
Too much/little lava rock
Add/remove lava rock to proper
level; single layer only with air
space.
LIMITED WARRANTY
The Connerton Company warrants to the original user for a period of one year from date of installation, not
to exceed 18 months from date of shipment by Connerton, that the equipment manufactured is free from
defects in material or workmanship.
Our obligation under this warranty shall be limited to furnishing without charge any part of said product
which, upon examination by The Connerton Company shall prove to be defective. Parts wear is not
considered a defect. The Connerton Company will not be responsible for labor or transportation charges
incidental to the replacement of same.
The Connerton Company assumes no responsibility for failure of the equipment to operate properly due to
improper installation or operation. This warranty applies to all equipment that has been unaltered, properly
installed and maintained in accordance with national and local codes and in accordance with the
installation and operating instructions included with this equipment.
This warranty does not extend to normal maintenance items, including but not limited to, air and gas
adjustments and adjustments to pilot flames. Proper installation, adjustments, and initial checkout is the
responsibility of the dealer, the owner-user or installer and not that of The Connerton Company.
Exceptions to warranty:
1) Lower lava rock broiler grates.
Please fill out and refer to the following when contacting the factory:
Model # RLRB-23-
-A Serial#
Gas Type:
Purchase Date:
|