Cisco Systems Network Card OC192 STM64 LR LH 4 User Manual

Installing the Cisco ONS 15600 OC192/STM64  
LR/LH 4 Port 1550 Card  
Note  
The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These  
terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring  
configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer  
generally to Cisco's path protection feature, which may be used in any topological network  
configuration. Cisco does not recommend using its path protection feature in any particular  
topological network configuration.  
Product Name: 15600-192L4-LR1550=  
This document contains a description of OC192/STM64 LR/LH 4 Port 1550 card features, installation  
procedures, removal instructions, and technical specifications. Use this document in conjunction with  
the Cisco ONS 15600 Reference Manual, the Cisco ONS 15600 Procedure Guide, and the Cisco ONS  
15600 Troubleshooting Guide when working with OC192/STM64 LR/LH 4 Port 1550 cards.  
This document contains the following sections:  
This document contains the following procedures:  
Note  
For information about circuits and card capacities, see the Cisco ONS 15600 Reference Manual.  
Warning  
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.  
Co rp o ra t e He a d q u a rt e rs :  
Cis c o S ys t e m s , In c ., 1 7 0 We s t Ta s m a n Drive , S a n J o s e , CA 9 5 1 3 4 -1 7 0 6 US A  
Copyright © 2003-2007. Cisco System s, Inc. All rights reserved.  
 
OC192/STM64 LR/LH 4 Port 1550 Card  
Table 1  
OC192/ STM64 LR/ LH Card Perform ance Monitoring Thresholds  
Performance Monitoring  
Thresholds (15 min./1 day)  
Near-End Line PMs for the OC192/STM64 LR/LH Card  
CV-L  
85040/850400  
87/864  
10/40  
ES-L  
FC-L  
SES-L  
1/4  
UAS-L  
3/10  
PSC  
1/5  
PSD  
300/600  
Near-End Section PMs for the OC192/STM64 LR/LH Card  
CV-S  
10000/100000  
500/5000  
ES-S  
SES-S  
500/5000  
SEFS-S  
500/5000  
Near-End Path PMs for the OC192/STM64 LR/LH Card  
CV-P  
75/750  
60/600  
10/10  
3/7  
ES-P  
FC-P  
SES-P  
UAS-P  
10/10  
0/0  
PPJC-Pdet  
NPJC-Pdet  
0/0  
PPJC-Pgen  
0/0  
NPJC-Pgen  
0/0  
Far-End Line PMs for the OC192/STM64 LR/LH Card  
CV-LFE  
850400/85040  
864/87  
40/10  
ES-LFE  
FC-LFE  
SES-LFE  
4/1  
UAS-LFE  
10/3  
Far-End Path PMs for the OC192/STM64 LR/LH Card  
CV-PFE  
75/750  
60/600  
10/10  
3/7  
ES-PFE  
FC-PFE  
SES-PFE  
UAS-PFE  
10/10  
Physical PMs for the OC192/STM64 LR/LH Card  
Installing the Cisco ONS 15600 OC192/STM64 LR/LH 4 Port 1550 Card  
78-15181-01  
3
 
 
OC192/STM64 LR/LH 4 Port 1550 Card  
Table 1  
OC192/ STM64 LR/ LH Card Perform ance Monitoring Thresholds (continued)  
Performance Monitoring  
Thresholds (15 min./1 day)  
LBC-High  
LBC-Low  
OPT-High  
OPT-Low  
OPR-High  
OPR-Low  
150%  
50%  
120%  
80%  
200%  
50%  
Note  
SONET path PMs will not count unless IPPM is enabled. For additional information, see the Enabling  
Intermediate-Path Performance Monitoring section in the Cisco ONS 15600 Procedures Guide. To  
monitor SONET path PMs, log into the far-end node directly.  
Installing the Cisco ONS 15600 OC192/STM64 LR/LH 4 Port 1550 Card  
78-15181-01  
4
 
OC192/STM64 LR/LH 4 Port 1550 Card  
OC192/STM64 LR/LH 4 Port 1550 Faceplate and Block Diagram  
Figure 1 shows the OC192/STM64 LR/LH 4 port 1550 faceplate and a block diagram of the card.  
Figure 1  
OC192/ STM64 LR/ LH 4 port 1550 faceplate and block diagram  
OC192/STM64  
LR/LH 4 PORT  
1550  
STAT  
SRV  
SD  
SF  
LASER ON  
16  
C-STS-48 copy A  
C-STS-48 copy B  
16  
OC192  
4 x OC-192  
4 x OC-192  
16  
16  
C-STS-48 copy A  
C-STS-48 copy B  
Note: Each C-STS-192 is split into four  
C-STS-48s for cross-connect purposes.  
Installing the Cisco ONS 15600 OC192/STM64 LR/LH 4 Port 1550 Card  
78-15181-01  
5
 
 
OC192/STM64 LR/LH 4 Port 1550 Card  
OC192/STM64 LR/LH 4 Port 1550 Card-Level Indicators  
Table 2 describes the functions of the card-level LEDs on the OC192/STM64 LR/LH card.  
Table 2  
OC192/ STM64 LR/ LH 4 port 1550 Card-Level Indicators  
Indicators  
Color  
Description  
STAT LED  
Red  
Indicates a hardware fault; this LED is off during normal operation.  
Replace the unit if the STAT LED persists. During diagnostics, the LED  
will flash quickly during initialization and flash slowly during  
configuration synchronization.  
SRV LED  
Green  
Green  
Indicates the service mode of the card. Green indicates the card is in use;  
off indicates when the card can be removed for service.  
LASER ON  
The green LASER ON LED indicates that at least one of the card’s lasers  
is active.  
OC192/STM64 LR/LH 4 Port 1550 Network-Level Indicators  
Table 3 describes the functions of the network-level LEDs on the OC192/STM64 LR/LH card.  
Table 3  
OC192/ STM64 LR/ LH 4 port 1550 Network-Level Indicators  
Indicators  
SD LED  
Color  
Description  
Blue  
The blue SD LED indicates a signal degrade or condition such as a low  
signal level on at least one of the card’s ports.  
SF LED  
Red  
The red SF LED indicates a signal failure or condition such as LOS,  
LOF, or high BERs on at least one of the card’s ports. The red SF LED  
also illuminates when the transmit and receive fibers are incorrectly  
connected. When the fibers are properly connected, the LED turns off.  
Warning  
Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do  
not stare into the beam or view directly with optical instruments. Viewing the laser output with  
certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance  
of 100 mm may pose an eye hazard. Use of controls or adjustments or performance of procedures other  
than those specified may result in hazardous radiation exposure.  
Installing the Cisco ONS 15600 OC192/STM64 LR/LH 4 Port 1550 Card  
78-15181-01  
6
 
   
OC192/STM64 LR/LH 4 Port 1550 Card  
OC192/STM64 LR/LH 4 Port 1550 Specifications  
Table 4 shows the OC192/STM64 LR/LH card specifications.  
Table 4  
OC192/ STM64 LR/ LH 4 Port 1550 Card Specifications  
Specification Type  
Line  
Description  
Bit Rate: 9.96 Gbps  
Code: Scrambled NRZ  
Fiber: 1550 nm Single Mode  
Max. Transmitter Output Power: +7 dBm  
Min. Transmitter Output Power: +4 dBm  
Center Wavelength: 1530 nm to 1565 nm  
Nominal Wavelength: 1550 nm  
Transmitter  
Transmitter: LN (Lithium Niobate) external modulator transmitter  
Max. Receiver Level: –9 dBm  
Receiver  
Min. Receiver Level: –22 dBm  
Receiver: APD/TIA  
Link Loss Budget: 24 dB min., with no dispersion or 22 dB optical path loss  
at BER = 1- exp (–12) including dispersion  
Loopback Mode  
Payload  
Note  
You must use a 19 to 24 dB (20 recommended) fiber attenuator when  
connecting a fiber loopback to an OC192/STM64 LR/LH  
4 port 1550 card. Never connect a direct fiber loopback.  
Connectors  
OGI  
Operating Temperature  
Operating Humidity  
Dimensions  
23 to 122 degrees Fahrenheit (–5 to +50 degrees Celsius)  
5 to 95%, non-condensing  
Height: 16.50 in. (419 mm)  
Width: 1.07 in. (27 mm)  
Depth: 18.31 in. (465 mm)  
Card Weight: 12.0 lbs (5.44 kg)  
Telcordia SONET, GR-253  
Compliance  
When installed in a system, ONS 15600 cards comply with these safety  
standards: UL 60950, CSA C22.2 No. 950, EN 60950, IEC 60950  
Eye Safety Compliance: Class 1 (21 CFR 1040.10 and 1040.11) and Class 1  
(IEC 60825) laser products  
Installing the Cisco ONS 15600 OC192/STM64 LR/LH 4 Port 1550 Card  
78-15181-01  
7
 
 
Replace an OC-192 Card  
OC1928/STM64 LR/LH 4 Port 1550 Card OGI Connector Pinout  
Table 5 shows the OC192/STM64 LR/LH card OGI connector pinouts.  
Table 5  
OC192/ STM64 LR/ LH 4 Port 1550 Card OGI Connector Pinout  
Connector  
OGI Pin and Card Port  
1
1
2
3
4
5
6
7
8
1
2
Transmit 1 Receive 1  
5
6
7
8
2
3
4
3
4
1
2
Transmit 2 Receive 2  
5
6
7
8
3
4
1
2
Transmit 3 Receive 3  
5
6
7
8
3
4
Transmit 4 Receive 4  
Replace an OC-192 Card  
Purpose  
This procedure is used to replace a faulty OC-192 card.  
Tools/Equipment  
Prerequisite Procedures  
Required/As Needed  
Onsite/Remote  
Replacement OC-192 card  
None  
As needed  
Onsite  
Warning  
Note  
Do not reach into a vacant slot or chassis while you install or remove a module or a fan. Exposed  
circuitry could constitute an energy hazard.  
Card removal raises an improper removal (IMPROPRMVL) alarm, but this clears after the card  
replacement is completed.  
Step 1  
Step 2  
Log into the node where you will replace the OC-192 card. If necessary, refer to the  
Cisco ONS 15600 Procedure Guide for a login procedure.  
Ensure that the card you are replacing does not carry traffic in a 1+1 group:  
a. In the node view, click the Maintenance > Protection tabs.  
b. Choose the first group listed under Protection Groups.  
c. Verify that the slot number for the card you are replacing does not appear in the Selected Groups  
list. For example, if you are replacing the OC-192 card in slot 3, make sure that Selected Groups  
does not contain any entries that start with s3, regardless of the port.  
d. Repeat Steps b and c for each protection group.  
e. If any of the groups contain a port on the card you want to replace, perform the “Force-Switch 1+1  
Installing the Cisco ONS 15600 OC192/STM64 LR/LH 4 Port 1550 Card  
78-15181-01  
8
 
       
Replace an OC-192 Card  
Step 3  
Ensure that the card you are replacing does carry path protection circuit traffic.  
Note  
A port can be part of a 1+1 protection group or part of a path protection, but it cannot be  
configured for both. However, different ports on one card can be configured in different ways. If  
you move all of the traffic off some 1+1 ports, you still need to check whether the remaining  
ports are carrying path protection traffic.  
a. In the CTC node view, click View > Go to Parent View.  
b. Click the Circuits tab.  
c. View the circuit source and destination ports and slots. If any circuits originate or terminate in the  
slot containing the card you are replacing, perform the “Force-Switch Path Protection Paths” task  
Note  
If the card you are replacing is not configured for any port or circuit protection, but does  
carry traffic, bridge and roll this traffic onto another card. Follow the “Bridge and Roll  
Traffic” procedure in the Cisco ONS 15600 Procedure Guide.  
Step 4  
Step 5  
Remove any fiber optic cables from the ports.  
Physically remove the card to be replaced from the ONS 15600 shelf:  
a. Open the card ejectors.  
b. Slide the card out of the slot.  
Step 6  
Physically replace the OC-192 card in the shelf:  
a. Open the ejectors on the replacement card.  
b. Slide the replacement card into the slot along the guide rails until it contacts the backplane.  
c. Close the ejectors.  
Note  
When you replace a card with an identical type of card, you do not need to make any changes  
to the database.  
Step 7  
Step 8  
Clear the Force switches.  
To clear 1+1 Force switches, complete the “Clear a 1+1 Force Switch” task on page 11.  
To clear Path Protection Force switches, complete the “Clear a Path Protection Force Switch” task  
Once the card is placed in service and is receiving traffic, reset the card’s physical receive power level  
threshold in CTC:  
a. Double-click the newly installed card in CTC node view.  
b. Click the Provisioning > Threshold tabs.  
c. Click the Physical radio button.  
d. Click Set OPM for each port on the card.  
.
Installing the Cisco ONS 15600 OC192/STM64 LR/LH 4 Port 1550 Card  
78-15181-01  
9
 
Replace an OC-192 Card  
Force-Switch 1+1 Ports  
Purpose  
This procedure forces 1+1 protection group traffic from one port in the  
group to the other. It is used to remove traffic from a card for  
replacement.  
Tools/Equipment  
Installed OC-N cards  
Installed OC-192 card  
As needed  
Prerequisite Procedures  
Required/As Needed  
Onsite/Remote  
Onsite or remote  
Note  
The Force switch is performed even if the destination path is degraded.  
Step 1  
Step 2  
Step 3  
In the CTC node view, click the Maintenance > Protection tabs.  
Select the protection group you want to Force-switch from Protection Groups.  
Under Selected Groups, choose the port belonging to the card you are replacing by clicking it. For  
example, if the card you are replacing contains the protect/standby port, click this port.  
Step 4  
Step 5  
Step 6  
Click the Force button.  
If the switch is successful, the group will say either FORCE TO WORKING or FORCE TO PROTECT.  
Return to the “Replace an OC-192 Card” procedure on page 8, or to your originating procedure.  
Force-Switch Path Protection Paths  
Purpose  
This procedure forces all circuits in a path protection from one span to  
the other. It is used to remove traffic from a card that originates or  
terminates path protection circuits.  
Tools/Equipment  
Installed OC-192 cards  
None  
Prerequisite Procedures  
Required/As Needed  
Onsite/Remote  
As needed  
Onsite or remote  
Note  
The Force switch is performed even if the destination path is degraded.  
Step 1  
Step 2  
Step 3  
In the CTC node view, click View > Go to Network View if this view is not already displayed.  
Click the Circuits tab.  
Note, print, or export the list of circuits from this tab, and mark the circuits involving the slot containing  
the card you are replacing.  
For information about doing this from CTC, refer to the procedures in the  
Cisco ONS 15600 Procedures Guide.  
Installing the Cisco ONS 15600 OC192/STM64 LR/LH 4 Port 1550 Card  
78-15181-01  
1 0  
 
   
Replace an OC-192 Card  
Step 4  
In the network map, right-click a circuit connected to the node where you are performing the Force  
switch. Choose Circuits from the shortcut menu.  
The Circuits window is displayed.  
Step 5  
Step 6  
Verify that this list contains the same circuits that you marked in the list.  
Choose Force from the pull-down menu at the bottom of the window.  
If the switch was successful, all circuits will show FORCE in the Switch State column.  
Return to the“Replace an OC-192 Card” procedure on page 8, or to your originating procedure.  
Step 7  
Clear a 1+1 Force Switch  
Purpose  
This procedure clears a 1+1 protection group Force switch. It is used to  
revert traffic to the original port after the card has been serviced.  
Tools/Equipment  
None  
Prerequisite Procedures  
As needed  
Required/As Needed  
Onsite/Remote  
Onsite or remote  
Note  
If the ports terminating a span are configured as revertive, clearing a Manual or Force switch to protect  
(or working) moves traffic back to the working (or protect) port. If ports are not configured as revertive,  
clearing a Manual or Force switch to protect does not move traffic back.  
Step 1  
Step 2  
Step 3  
Step 4  
Step 5  
In the CTC node view, click the Maintenance > Protection tabs.  
Under Protection Groups, click the protection group containing the port you want to clear.  
Under Selected Group, click the port you want to clear.  
In the Inhibit Switching area, click Clear.  
Click Yes in the confirmation dialog box.  
The lockout is cleared.  
The Force switch is cleared. Traffic will revert to the original port if the group was configured for  
revertive switching.  
Step 6  
Return to the “Replace an OC-192 Card” procedure on page 8, or to your originating procedure.  
Installing the Cisco ONS 15600 OC192/STM64 LR/LH 4 Port 1550 Card  
78-15181-01  
1 1  
 
 
Related Documentation  
Clear a Path Protection Force Switch  
Purpose  
This procedure clears a path protection circuit Force switch. It is used to  
revert traffic to the original circuits after the card has been serviced.  
Tools/Equipment  
None  
Prerequisite Procedures  
Required/As Needed  
Onsite/Remote  
As needed  
Onsite or remote  
Step 1  
Step 2  
In the CTC node view, click View > Go to Network View if this view is not already displayed.  
In the network map, right-click the span that you Force switched. Choose Circuits from the shortcut  
menu.  
The Circuits window is displayed.  
Step 3  
Choose Clear from the pull-down menu at the bottom of the window.  
The Force switch is cleared.  
Note  
Active circuits are displayed green in the Circuits window. Standby circuits are displayed purple  
in the window.  
Note  
If these circuits are configured for revertive switching, they will revert to original paths after the  
revertive time expires. If they are not revertive, they will not move back unless you Force-switch  
them back. If the switch state is clear, you can complete the “Force-Switch Path Protection  
Paths” task on page 10 again to force traffic back to the original path.  
Step 4  
Return to the“Replace an OC-192 Card” procedure on page 8, or to your originating procedure.  
Related Documentation  
DOC-7814303= Cisco ONS 15600 Procedure Guide  
DOC-7814706= Cisco ONS 15600 Reference Manual  
DOC-7814707= Cisco ONS 15600 Troubleshooting Guide  
Obtaining Documentation  
The following sections explain how to obtain documentation from Cisco Systems.  
Installing the Cisco ONS 15600 OC192/STM64 LR/LH 4 Port 1550 Card  
78-15181-01  
1 2  
 
   
Obtaining Documentation  
World Wide Web  
You can access the most current Cisco documentation on the World Wide Web at the following URL:  
Translated documentation is available at the following URL:  
Documentation CD-ROM  
Cisco documentation and additional literature are available in a Cisco Documentation CD-ROM  
package, which is shipped with your product. The Documentation CD-ROM is updated monthly and may  
be more current than printed documentation. The CD-ROM package is available as a single unit or  
through an annual subscription.  
Ordering Documentation  
Cisco documentation is available in the following ways:  
Registered Cisco Direct Customers can order Cisco product documentation from the Networking  
Products MarketPlace:  
Registered Cisco.com users can order the Documentation CD-ROM through the online Subscription  
Store:  
Nonregistered Cisco.com users can order documentation through a local account representative by  
calling Cisco corporate headquarters (California, USA) at 408 526-7208 or, elsewhere in North  
America, by calling 800 553-NETS (6387).  
Documentation Feedback  
If you are reading Cisco product documentation on Cisco.com, you can submit technical comments  
electronically. Click Leave Feedback at the bottom of the Cisco Documentation home page. After you  
complete the form, print it out and fax it to Cisco at 408 527-0730.  
You can e-mail your comments to [email protected].  
To submit your comments by mail, use the response card behind the front cover of your document, or  
write to the following address:  
Cisco Systems  
Attn: Document Resource Connection  
170 West Tasman Drive  
San Jose, CA 95134-9883  
We appreciate your comments.  
Installing the Cisco ONS 15600 OC192/STM64 LR/LH 4 Port 1550 Card  
78-15181-01  
1 3  
 
Obtaining Technical Assistance  
Obtaining Technical Assistance  
Cisco provides Cisco.com as a starting point for all technical assistance. Customers and partners can  
obtain documentation, troubleshooting tips, and sample configurations from online tools by using the  
Cisco Technical Assistance Center (TAC) Web Site. Cisco.com registered users have complete access to  
the technical support resources on the Cisco TAC Web Site.  
Cisco.com  
Cisco.com is the foundation of a suite of interactive, networked services that provides immediate, open  
access to Cisco information, networking solutions, services, programs, and resources at any time, from  
anywhere in the world.  
Cisco.com is a highly integrated Internet application and a powerful, easy-to-use tool that provides a  
broad range of features and services to help you to  
Streamline business processes and improve productivity  
Resolve technical issues with online support  
Download and test software packages  
Order Cisco learning materials and merchandise  
Register for online skill assessment, training, and certification programs  
You can self-register on Cisco.com to obtain customized information and service. To access Cisco.com,  
go to the following URL:  
Technical Assistance Center  
The Cisco TAC is available to all customers who need technical assistance with a Cisco product,  
technology, or solution. Two types of support are available through the Cisco TAC: the Cisco TAC  
Web Site and the Cisco TAC Escalation Center.  
Inquiries to Cisco TAC are categorized according to the urgency of the issue:  
Priority level 4 (P4)—You need information or assistance concerning Cisco product capabilities,  
product installation, or basic product configuration.  
Priority level 3 (P3)—Your network performance is degraded. Network functionality is noticeably  
impaired, but most business operations continue.  
Priority level 2 (P2)—Your production network is severely degraded, affecting significant aspects  
of business operations. No workaround is available.  
Priority level 1 (P1)—Your production network is down, and a critical impact to business operations  
will occur if service is not restored quickly. No workaround is available.  
Which Cisco TAC resource you choose is based on the priority of the problem and the conditions of  
service contracts, when applicable.  
Installing the Cisco ONS 15600 OC192/STM64 LR/LH 4 Port 1550 Card  
78-15181-01  
1 4  
 
 
Obtaining Technical Assistance  
Cisco TAC Web Site  
The Cisco TAC Web Site allows you to resolve P3 and P4 issues yourself, saving both cost and time. The  
site provides around-the-clock access to online tools, knowledge bases, and software. To access the  
Cisco TAC Web Site, go to the following URL:  
All customers, partners, and resellers who have a valid Cisco services contract have complete access to  
the technical support resources on the Cisco TAC Web Site. The Cisco TAC Web Site requires a  
Cisco.com login ID and password. If you have a valid service contract but do not have a login ID or  
password, go to the following URL to register:  
If you cannot resolve your technical issues by using the Cisco TAC Web Site, and you are a Cisco.com  
registered user, you can open a case online by using the TAC Case Open tool at the following URL:  
If you have Internet access, it is recommended that you open P3 and P4 cases through the Cisco TAC  
Web Site.  
Cisco TAC Escalation Center  
The Cisco TAC Escalation Center addresses issues that are classified as priority level 1 or priority  
level 2; these classifications are assigned when severe network degradation significantly impacts  
business operations. When you contact the TAC Escalation Center with a P1 or P2 problem, a Cisco TAC  
engineer will automatically open a case.  
To obtain a directory of toll-free Cisco TAC telephone numbers for your country, go to the following  
URL:  
Before calling, please check with your network operations center to determine the level of Cisco support  
services to which your company is entitled; for example, SMARTnet, SMARTnet Onsite, or Network  
Supported Accounts (NSA). In addition, please have available your service agreement number and your  
product serial number.  
CCVP, the Cisco logo, and the Cisco Square Bridge logo are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn is a  
service mark of Cisco Systems, Inc.; and Access Registrar, Aironet, BPX, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, Cisco, the Cisco  
Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity,  
Enterprise/Solver, EtherChannel, EtherFast, EtherSwitch, Fast Step, Follow Me Browsing, FormShare, GigaDrive, HomeLink, Internet Quotient, IOS,  
iPhone, IP/TV, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, iQuick Study, LightStream, Linksys, MeetingPlace, MGX, Networking Academy,  
Network Registrar, Packet, PIX, ProConnect, ScriptShare, SMARTnet, StackWise, The Fastest Way to Increase Your Internet Quotient, and TransPath are  
registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries.  
All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner does not imply a  
partnership relationship between Cisco and any other company. (0705R)  
Copyright © 2003-2007, Cisco Systems, Inc.  
All rights reserved.  
Installing the Cisco ONS 15600 OC192/STM64 LR/LH 4 Port 1550 Card  
78-15181-01  
1 5  
 
Obtaining Technical Assistance  
Installing the Cisco ONS 15600 OC192/STM64 LR/LH 4 Port 1550 Card  
78-15181-01  
1 6  
 

Belkin Switch F1DS102U User Manual
BenQ Projector MP770 User Manual
Bolens Lawn Mower 115 050 000 User Manual
Bowflex Fitness Equipment 552 User Manual
Bravetti Cookware CW23HCH User Manual
Briggs Stratton Automobile Parts 132200 User Manual
Briggs Stratton Tiller 5055 6 HP User Manual
Bushnell Hunting Equipment 204100 204101 User Manual
Cateye Home Gym EC 37OO User Manual
Cavalier Cordless Telephone cav 100753 User Manual