Chief Manufacturing TV Mount RLF2 User Manual

I N S T A L L A T I O N I N S T R U C T I O N S  
Instrucciones de instalación  
Installationsanleitung  
Istruzioni di installazione  
Installatie-instructies  
Instruções de Instalação  
Instructions d´installation  
RMF2  
RLF2  
RXF2  
Universal Fixed Mounts  
Spanish Product Description  
German Product Description  
Portuguese Product Description  
Italian Product Description  
Dutch Product Description  
French Product Description  
RMF2/RLF2/RXF2  
 
Installation Instructions  
RMF2/RLF2/RXF2  
DIMENSIONS - RMF2  
558.8  
22.00  
[449]  
17.68  
MAX  
200  
WALL PLATE  
OPENING  
7.87  
TOP MOUNTING  
HOLE TO C ENTERLINE  
ARROW ON THE  
WALL PLATE  
8.7  
.34  
279.4  
11.00  
20.1  
.79  
177.8  
7.00  
WALL PLATE  
OPENING  
25.4  
1.00  
212.7  
8.38  
(UP TO 1.54  
USING SPAC ERS)  
419.1  
16.50  
400  
15.75  
MAX  
ORIENTATION  
63.5  
2.50  
C ENTERLINE  
TO BOTTOM OF  
WALL PLATE  
OPENING  
AND C ENTERLINE  
NOTC HES  
C ENTERLINE  
DIAMOND  
-KIC KSTAND LANYARDS  
-WHEN KIC KSTAND  
IS AC TIVATED, THE  
DISPLAY TILTS BAC K 5  
7.1  
.28  
HOLE SIZE  
FOR LOC K  
DETAIL A  
SC ALE 1 : 2  
DETAIL B  
SC ALE 1 : 2  
DIMENSIONS - RLF2  
WALL PLATE  
OPENING  
781.1  
30.75  
200  
[670]  
26.38  
MAX  
7.87  
TOP MOUNTING  
HOLE TO CENTERLINE  
ARROW ON THE  
WALL PLATE  
8.7  
.34  
390.5  
15.38  
20.1  
.79  
177.8  
7.00  
WALL PLATE  
OPENING  
25.4  
1.00  
212.7  
8.38  
(UP TO 1.54  
USING SPAC ERS)  
419.1  
16.50  
400  
15.75  
MAX  
ORIENTATION  
AND C ENTERLINE  
NOTC HES  
63.5  
2.50  
C ENTERLINE  
DIAMOND  
CENTERLINE  
TO BOTTOM OF  
WALL PLATE  
OPENING  
-KICKSTAND LANYARDS  
-WHEN KIC KSTAND  
IS AC TIVATED, THE  
DISPLAY TILTS BACK 5  
7.1  
.28  
HOLE SIZE  
FOR LOC K  
DETAIL A  
SC ALE 1 : 2  
DETAIL B  
SC ALE 1 : 2  
3
 
RMF2/RLF2/RXF2  
Installation Instructions  
DIMENSIONS - RXF2  
WALL PLATE  
OPENING  
965.2  
38.00  
200  
7.87  
[965.2]  
38.00  
MAX  
TOP MOUNTING  
HOLE TO C ENTERLINE  
ARROW ON THE  
WALL PLATE  
482.6  
19.00  
20.1  
.79  
25.4  
1.00  
177.8  
7.00  
WALL PLATE  
OPENING  
(UP TO 1.54  
USING SPAC ERS)  
212.7  
8.38  
8.7  
.34  
500  
19.69  
MAX  
ORIENTATION  
AND C ENTERLINE  
NOTC HES  
63.5  
2.50  
C ENTERLINE  
TO BOTTOM OF  
WALL PLATE  
OPENING  
C ENTERLINE  
DIAMOND  
7.1  
.28  
HOLE SIZE  
FOR LOC K  
-KIC KSTAND LANYARDS  
DETAIL A  
SC ALE 1 : 2  
-WHEN KIC KSTAND  
IS AC TIVATED, THE  
DISPLAY TILTS BAC K 5  
DETAIL B  
SC ALE 1 : 2  
4
 
Installation Instructions  
RMF2/RLF2/RXF2  
LEGEND  
Tighten Fastener  
Pencil Mark  
Apretar elemento de fijación  
Befestigungsteil festziehen  
Apertar fixador  
Marcar con lápiz  
Stiftmarkierung  
Marcar com lápis  
Segno a matita  
Serrare il fissaggio  
Bevestiging vastdraaien  
Serrez les fixations  
Potloodmerkteken  
Marquage au crayon  
Loosen Fastener  
Drill Hole  
Aflojar elemento de fijación  
Befestigungsteil lösen  
Desapertar fixador  
Perforar  
Bohrloch  
Fazer furo  
Praticare un foro  
Gat boren  
Allentare il fissaggio  
Bevestiging losdraaien  
Desserrez les fixations  
Percez un trou  
Phillips Screwdriver  
Adjust  
Destornillador Phillips  
Ajustar  
Kreuzschlitzschraubendreher  
Chave de fendas Phillips  
Cacciavite a stella  
Einstellen  
Ajustar  
Regolare  
Afstellen  
Ajuster  
Kruiskopschroevendraaier  
Tournevis à pointe cruciforme  
Open-Ended Wrench  
Llave de boca  
Remove  
Quitar  
Gabelschlüssel  
Chave de bocas  
Chiave a punte aperte  
Steeksleutel  
Entfernen  
Remover  
Rimuovere  
Verwijderen  
Retirez  
Clé à fourche  
By Hand  
Optional  
Opcional  
Optional  
Opcional  
Opzionale  
Optie  
A mano  
Von Hand  
Com a mão  
A mano  
Met de hand  
À la main  
En option  
Hex-Head Wrench  
Security Wrench  
Llave de cabeza hexagonal  
Sechskantschlüssel  
Chave de cabeça sextavada  
Chiave esagonale  
Llave de seguridad  
Sicherheitsschlüssel  
Chave de segurança  
Chiave di sicurezza  
Veiligheidssleutel  
Clé de sécurité  
Zeskantsleutel  
Clé à tête hexagonale  
5
 
RMF2/RLF2/RXF2  
Installation Instructions  
TOOLS REQUIRED FOR INSTALLATION  
7/32" (5.5mm)  
5/16" (7.9mm)  
1/2" (12.7mm)  
#2  
PARTS  
B(2)  
[vertical bracket]  
A(1)  
[wall plate]  
[RLF2 shown]  
For below kit, quantities  
are 4 for RMF2 and  
RLF2, 6 for RXF2  
F (1)  
Hardware Bag  
FA(8)  
M4 x 16mm  
FE(6)  
M5 x 16mm  
FI(6)  
M6 x 16mm  
FL(6)  
M8 x 20mm  
FP(8)  
1/4"(6.4mm)  
C(4 or 6)  
5/16 x 2 1/2"  
FF(6)  
M5 x 20mm  
FM(6)  
M8 x 30mm  
FJ(6)  
M6 x 25mm  
FB(6)  
M4 x 20mm  
FQ(8)  
1/2"(12.7mm)  
D(4 or 6)  
5/16"  
FN(6)  
M8 x 40mm  
FC(6)  
M4 x 25mm  
FG(6)  
M5 x 25mm  
FK(6)  
M6 x 35mm  
FS(8)  
[universal washer]  
E(4 or 6)  
[concrete anchor]  
FD(6)  
M4 x 35mm  
FH(6)  
M5 x 35mm  
FO(6)  
M8 x 50mm  
6
 
Installation Instructions  
RMF2/RLF2/RXF2  
Assembly And Installation  
Install Wall Plate to Wall - Wood Studs  
2
x 4 or 6  
WARNING: Failure to provide adequate structural strength  
for this component can result in serious personal injury or  
damage to equipment! It is the installer’s responsibility to  
make sure the structure to which this component is attached  
can support five times the combined weight of all equipment.  
Reinforce the structure as required before installing the  
component. The wall to which the mount is being attached  
may have a maximum drywall thickness of 5/8" (1.6cm). Do  
not install drywall anchors into the seam between drywall  
pieces.  
3
1. Unfold wall plate (A) to prepare it for mounting to wall. (See  
Figure 1)  
Figure 2  
2 x 24"  
1
(A)  
2 x 16"  
1
Figure 1  
3 x 16"  
C E N T E R  
L IN E  
2. Level wall plate (A) and mark locations of pilot holes.(See  
Figure 2)  
NOTE: The RMF2 must be installed on two 16" studs. The  
RLF2 can be installed on 16" studs (inner holes) or 24"  
studs (outer holes). For the RXF2, it can be mounted  
over two or three 16" studs or two 24" studs. If  
Figure 3  
mounting to three 16" studs, it must be mounted to all  
three studs using the outer holes and center holes.  
(See Figures 2 and 3) All studs must be 2"x4".  
4. Install 5/16 x 2 1/2" hex head cap screws (C) through four  
flat washers (D), wall plate (A) and into wood studs. (See  
Figure 4)  
NOTE: The vertical center of the display will be even with the  
center line indicated on the labels located directly  
below each hinge. Keep this in mind when determining  
mounting location. (See Figure 3)  
(D) x 4 or 6  
3. Drill 7/32" (5.5mm) diameter pilot holes into wood studs at  
marked locations. (See Figure 2)  
(C) x 4 or 6  
(A)  
4
Figure 4  
7
 
RMF2/RLF2/RXF2  
Installation Instructions  
3. Drill 5/16" (8mm) diameter pilot holes into wall at marked  
locations. Holes must be drilled at least 3 1/4 inches deep.  
(See Figure 5)  
Install Wall Plate to Wall - Concrete or  
Concrete Block  
4. Install four or six concrete anchors (E) into drilled holes. Use  
a hammer to tap anchors into holes. (See Figures 6 and 7)  
WARNING: Failure to provide adequate structural strength  
for this component can result in serious personal injury or  
damage to equipment! It is the installer’s responsibility to  
make sure the structure to which this component is attached  
can support five times the combined weight of all equipment.  
Reinforce the structure as required before installing the  
component. The wall to which the mount is being attached  
may have a maximum drywall thickness of 5/8" (1.6cm).  
IMPORTANT ! : The anchors must be installed through  
any wall covering until flush with the concrete wall. (See  
Figure 6)  
concrete  
wall  
Pilot Hole -  
5/16 x 3 1/4"  
(M8 x 82.5mm)  
(D)  
WARNING: ELECTRICAL SHOCK HAZARD! CUTTING  
OR DRILLING INTO ELECTRICAL CORDS OR CABLES  
CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY!  
ALWAYS make certain area behind mounting surface is free  
of electrical wires and cables before drilling or installing  
fasteners.  
(C)  
Anchor (E)  
WARNING: EXPLOSION AND FIRE HAZARD! CUTTING  
OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH  
OR SERIOUS PERSONAL INJURY! ALWAYS make certain  
area behind mounting surface is free of gas, water, waste, or  
any other plumbing before cutting, drilling, or installing  
fasteners.  
Anchor  
flush with  
concrete  
wall  
(A)  
1. Unfold wall plate (A) to prepare it for mounting to wall. (See  
Figure 1)  
wall covering  
2. Level wall plate (A) and mark locations of pilot holes at  
desired mounting location. (See Figure 5)  
Figure 6  
IMPORTANT ! : The RMF2-RLF2-RXF2 mounts are  
designed to be mounted to 8" concrete or 8"x8"x16"  
concrete block.  
5. Using 1/2" (12.7mm) wrench, install screws (C) through flat  
washers (D), wall plate (A) and into concrete anchors (E).  
(See Figure 7)  
NOTE: For the RLF2, either the inner or outer four holes may  
be used.  
(E) x 4 or 6  
4
NOTE: For the RXF2, use the outer four holes and the two  
middle holes on wall plate for installation.  
(D) x 4 or 6  
NOTE: The vertical center of the display will be even with the  
center line indicated on the labels located directly  
below each hinge. Keep this in mind when determining  
mounting location. (See Figure 5)  
2
x 4 or 6  
3
CENTER  
LINE  
(C) x 4 or 6  
5
(A)  
Figure 5  
Figure 7  
8
 
Installation Instructions  
RMF2/RLF2/RXF2  
(non-recessed holes)  
(FS) x4,x6,x8  
Install Brackets to Display  
WARNING: The minimum hole pattern size is 100mm x  
100mm for the RMF2 and 200mm x 200mm for the RLF2 and  
the RXF2.  
(FA-FO) x4,x6,x8  
6
1. Lay display face down on protective surface.  
2
4
CAUTION: Using screws of improper diameter may  
damage your display! Proper screws will easily thread into  
display mounting holes.  
2. Select screw diameter by examining hardware (FA-FO)  
(8mm, 6mm, 5mm, or 4mm) and comparing with mounting  
holes on display. (See Figure 8)  
5
3. Select spacers: (See Figure 8)  
If mounting holes are not recessed and both  
brackets (B) can lay flat against display, then no  
spacers are required.  
If mounting holes are recessed, or if protrusions  
prevent brackets (B) from laying flat, then spacers  
(FP or FQ) must be used.  
(B) x 2  
If additional depth is needed behind display,  
spacers (FP and FQ) can be stacked on top of  
each other.  
(recessed holes or  
extra depth needed)  
(FA-FO) x4,x6,x8  
6
CAUTION: Using screws of improper length may damage  
your display! Proper screws will have adequate thread  
engagement without contacting bottom of display mounting  
holes.  
(FS) x4,x6,x8  
(FP or FQ)*  
2
4
3
4. Select screw length: (See Figure 8)  
Using your hand, insert SHORTEST length screw  
of selected diameter (FA, FE, FI or FL) through  
bracket (B), universal washer (FS), selected  
spacer (FP or FQ, if required), into display  
mounting hole. Do NOT thread screw into hole at  
this time.  
5
Proper screw length requires base of screw head  
to protrude above flat washer a distance equal to  
or greater than the screw diameter. If screw  
length is inadequate, select longer screw. Select  
shortest screw which will protrude the required  
distance.  
(B) x 2  
5. Place brackets (B) on display, ensuring: (See Figure 8)  
Upper hooks are towards top of display.  
Center of brackets (B) are as close to the center  
of the back of display as possible after being  
installed. Center of bracket is indicated by the  
diamond-shaped hole.  
*If additional depth is needed,  
spacers (FP or FQ) can be  
stacked on top of each other  
6. Using Phillips screwdriver, carefully install selected screws  
through universal washers (FS), brackets (B), and spacers  
(FP or FQ, if required), into display. (See Figure 8)  
Figure 8  
7. Tighten all screws. Ensure all applicable display mounting  
holes (4, 6, or 8) are used.  
9
 
RMF2/RLF2/RXF2  
Installation Instructions  
Install Display to Wall Plate  
(view from left side)  
WARNING: Exceeding the weight capacity can result in  
serious personal injury or damage to equipment! It is the  
installer’s responsibility to make sure the combined weight of  
all components attached does not exceed 125 lbs (56.7 kg)  
for the RMF2 and RLF2 or 175 lbs (79.4 kg) for the RXF2.  
Use with products heavier than the maximum weight  
indicated may result in collapse of the mount and its  
accessories causing possible injury.  
2
WARNING: Display may be very heavy! Ensure display  
can be safely lifted and maneuvered as required to install on  
wall plate. Failure to take adequate precautions can result in  
serious personal injury or damage to equipment!  
kickstand engaged  
WARNING: Interface brackets must be hung on opposite  
sides of the center tab on wall plate! (See Figure 9)  
center tab  
1
5
interface brackets  
must be hung on opposite  
sides of center tab  
Figure 10  
NOTE: Any cable management or rear display adjustments  
should be made when the display is resting on the  
kickstand.  
Figure 9  
1. Make sure interface brackets are in the kickstand position  
by pulling down on handles as far as possible. (See Figure  
10)  
2. Hang display with brackets (B) on upper rail of wall plate (A).  
Kickstand should be engaged with lower portion of wall  
plate. (See Figure 10)  
10  
 
Installation Instructions  
RMF2/RLF2/RXF2  
(views from left side)  
kickstand  
against wall  
locked  
position  
3
4
6
Figure 11  
3. Unlock kickstand by pushing up on interface brackets until  
kickstand rests against the wall. (See Figure 11)  
4. Push up on the interface brackets further in order to lock  
display into position against wall. (See Figure 11)  
5. Straps can be tucked behind display on notch on interface  
brackets (B) after installation is complete so that they will  
not be visable to the viewer. (See Figure 9)  
6. (Optional) Route padlock or cable lock (not included)  
through bottom holes on interface bracket to provide  
additional security. (See Figure 11)  
11  
 
RMF2/RLF2/RXF2  
Installation Instructions  
USA/International  
Europe  
A
P
F
A
P
F
6436 City West Parkway, Eden Prairie, MN 55344  
800.582.6480 / 952.225.6000  
877.894.6918 / 952.894.6918  
Franklinstraat 14, 6003 DK Weert, Netherlands  
+31 (0) 495 580 852  
+31 (0) 495 580 845  
Chief Manufacturing, a products division  
of Milestone AV Technologies  
Asia Pacific  
A
Office No. 1 on 12/F, Shatin Galleria  
18-24 Shan Mei Street  
Fotan, Shatin, Hong Kong  
852 2145 4099  
852 2145 4477  
8800-002426 Rev00  
¤2013 Milestone AV Technologies, a  
Duchossois Group Company  
11/13  
P
F
 

Black Decker Blender BL10451G AR CL User Manual
Black Decker Food Processor FP1450C User Manual
Blue Rhino Outdoor Fireplace WAF501C User Manual
Bosch Appliances Recording Equipment 811 User Manual
Brookstone Blood Pressure Monitor 516328 User Manual
Bryant Air Conditioner 342 User Manual
Casablanca Fan Company Fan 54031 User Manual
Chariot Carriers Baby Carrier 51100926 User Manual
Chevrolet Automobile 2008 Avalanche User Manual
Cisco Systems Network Card 350 User Manual