Channel Plus Carrying Case H218 User Manual

ChannelPlus Enclosures  
OpenHouse modules attach from the top  
1
1) Hook from the top  
2) Swing into place  
3) push button to lock  
H218 18” enclosure  
3
Telephone Master Hub (4 lines  
x
6
phones)  
ChannelPlus model H616  
From  
Telco  
Expansion  
Ports  
Telephones  
R
T
RJ31X  
4
3
2
1
R
T
R
T
Out  
R
T
H236 36” enclosure  
2
H290 AC outlet accessory  
H254 54” enclosure  
Mounting the enclosure  
16”  
Mounting the H290 AC outlet accessory  
On  
Center  
Use the mounting tabs when  
mounting the enclosure between  
the studs and using 1/2”  
wallboard.  
H290 installs in either of 2 locations  
Enclosure  
The H290 accessory brings AC power  
inside the H218, H236 or H254  
enclosure. The H290 gives the  
installer a clean, UL approved location  
to mount power adaptors. Mount the  
H290 to either the upper right or upper  
left corner of the enclosure using the  
four #6 screws provided. Installation  
of AC outlets should be done only by a  
qualified electrician.  
Attach enclosure using 4 screws.  
Either from mounting tabs  
or inside holes.  
1/8”  
Enclosure  
Wallboard  
When using other than 1/2”  
Stud  
wallboard, remove the mounting tabs  
and mount the enclosure to protrude  
1/8” beyond the wallboard surface.  
1/2” knockouts for 120VAC  
14 3/8“  
Mounting in existing wallboard or  
surface mounting …  
Remove the mounting tabs.  
OEM  
AC ADAPTOR  
The H290 provides space for 4  
standard duplex receptacles.  
Wires should exit the H290 using  
the grommets provided. The  
grommets may be cut as shown.  
Part no.: 123-456  
U
L
181/8” for H218  
361/8” for H236  
541/8” for H254  
Grab the tabs with  
pliers and rock back  
and forth to remove.  
Installing cables  
Remove knockouts as needed  
and line holes with grommets provided  
Grommet  
Installing the cover  
An old electrician’s trick  
When hanging a heavy cabinet cover,  
insert nails through the mounting holes  
on the cover. Guide the nails into the  
mating holes on the enclosure and let  
the cover hang from the nails while you  
attach the screws. (We’ve included two  
of these sophisticated devices for your  
assistance.)  
Remove paint shield and save.  
Route cabling into enclosure.  
After cabling is routed, reverse  
paint shield and return it to the  
enclosure to protect cabling.  
Grounding the cabinet  
When used with model H290 accessory, the grounding lug on the  
H290 is used. No separate ground lug is provided on the H218,  
H236 or H254. The user must install ground lugs as necessary.  
If H290 is installed, fold flaps on the  
paint shield to bend the shield over  
the H290 AC outlet accessory.  
 

Belkin Battery Charger F6H375 USB User Manual
Black Box Computer Hardware 16 24 Port 10 100 1000 RJ 45 Unmanaged Gigabit Switches User Manual
Black Box Network Hardware GSHDSL Four Wire Ethernet Network Extender Kit User Manual
Briggs Stratton Portable Generator 030235 01 User Manual
Canon Camera Lens 6472A002 User Manual
Carrier Air Conditioner 42C User Manual
Channel Vision Switch C 0501 User Manual
Chevrolet Automobile 2010 Tahoe Hybrid User Manual
Chicago Electric Septic System 92481 User Manual
Cisco Systems Conference Phone 1452302 User Manual