3. INSTALLATION  
resultwhenconnectingthebatterywiringduetoan  
initial charging of the internal input capacitor.  
3.05.2 Use stranded copper wire between  
the battery and inverter as indicated. A fuse must  
be installed between the battery and the inverter.  
U.L. requires that the fuse be within 18 inches of  
the battery.  
3.01 The following instructions should be  
thoroughly read and understood before installa-  
tion.  
3.02 CAUTION: Inverters produce hazard-  
ous voltages, to avoid risk of harm or fire the unit  
must be properly installed.  
CAUTION: Damage to the inverter will occur if  
correct polarity is not observed when installing  
the DC input cables.  
DC Input Cable Lengths (maximum)  
and Fusing Guide  
CAUTION: Damage to the inverter will occur if  
an external AC power source is applied to the  
inverter’s AC receptacle cord.  
CAUTION: Be sure the inverter's circuit breaker  
or fuse (if needed) are turned "OFF" during  
installation.  
Distance(feet)  
Model  
1 to 20  
6 Ga  
Fuse  
150A  
100A  
100A  
12Z8NV  
24Z8NV  
48Z8NV  
8 Ga  
8 Ga  
NOTE: All wiring must follow the National  
Electric Code, Provincial, or other codes in effect  
at the time of installation, regardless of sugges-  
tions in this manual. All wires should be copper  
conductors.  
3.05.3 NOTE: Using smaller input cable  
or longer length will greatly degrade the inverter  
peak performance.  
3.03 Mounting  
IMPORTANT NOTE FOR VEHICLE  
INSTALLATION: Do not use the vehicle chassis  
as the negative return in place of a return cable.  
Use the same size wire as the positive cable and  
run directly to the battery.  
3.05.4 Install the cables at the battery,  
inverter and then fuse holder. Make sure that  
clean, tightconnectionsaremade. Usecarenot  
totouchthepositiveandnegativewirestogether.  
Thiswillresultinaviolentsparkandcouldresultin  
explodingbatteriesandfire.  
3.05.5 The battery input terminals are at-  
tached to the unit : Red (+) and Black (-) cable,  
having 5/16" ring terminals. A spark may result  
when connecting the battery wire, due to an initial  
charging of the internal input capacitor.  
3.05.6 CAUTION: Damage to the inverter  
will occur if correct polarity is not observed. This  
damage is NOT covered by warranty.  
3.03.1  
Locate a suitable, secure flat  
mounting surface as close to the battery as  
possible without being in the same air tight  
compartment. The maximum recommended dis-  
tance between the mounting location and the  
battery is 20 feet. See DC Input Cable Lengths  
chart.  
3.03.2 The location should have adequate  
ventilation and clearance to maintain room tem-  
perature while the unit is operating. At least 1/2  
inch of clearance is required on all sides.  
3.03.3 Secure the unit with #8 or larger  
screws or bolts in the mounting slots on the  
flanges of the chassis.  
3.04 Chassis Bonding Lug - FIG. 1  
3.04.1 Connect a #8 gauge or greater cop-  
per wire between the bonding lug on the inverter  
and the earth grounding system or the vehicle  
chassis.  
3.06 Remote Switch for Inverter  
3.05 Battery Wiring - FIG. 1  
Operation - Fig. 1  
3.05.1 CAUTION: Make sure that hydro-  
gen gas does not accumulate near the battery by  
keeping the area well ventilated. A spark may  
3.06.1 All material used for the remote  
switch should be U.L. listed and installed per low  
Page 3  
 
voltage, Class 2, wiring code. The On/Off switch  
and in-line fuse to be purchased locally at an  
electrical supply outlet.  
5.02.1 Connect a 100 watt light bulb to the  
inverter output.  
5.02.2  
Make sure the inverter is turned  
3.06.2 A 3 Amp rated remote switch must  
be connected to the violet wire marked “Remote  
On/Off” coming out at front of the inverter.  
Connect the violet wire to the load side of the  
remote switch. The line side of the switch must be  
connected to the DC power source with a 3 Amp  
fuse within 18" of the source. The cable clamp  
strainreliefshouldbeusedtosecurethefieldwires.  
3.06.3 The switch should be mounted at a  
convenient location in a listed outlet box with  
approved strain relief. The in-line fuse to be  
mounted on appropriate fuse holder.  
"On", the output circuit breaker is reset and that  
the voltage is at least 12VDC, 24VDC or 48 VDC  
(depending on inverter model) at the DC input  
terminals. If not, check DC wiring connections  
and the line fuse.  
5.02.3  
Check the connection to the  
remote switch, +12VDC, +24VDC or +48VDC  
must be present at the violet wire for the unit to  
operate. If not, check any in-line fuses in the  
+12VDC, +24 or +48 VDC remote switch circuit.  
5.02.4 Observe the fault indicating lights  
on the front of the inverter.  
3.06.4 NOTE: A remote switch, must be  
installed to operate the inverter. You may use  
several switches or relays in parallel in lieu of one  
remote switch.  
a) The Low battery light indicates a low  
battery condition. Switch the inverter “Off” for 5  
seconds, then “On” again. The light coming on  
againindicatesafaultinthebatterywiring,battery  
capacity and voltage or the fuse.  
3.07 120 VAC Output  
3.07.1 CAUTION: Do not connect another  
source of AC power directly to the output of the  
inverter. This will result in damage to the inverter  
that is not covered under warranty!  
3.07.2 The 120 VAC output is provided at  
the GFCI protected female receptacle cord at-  
tached to the inverter.  
b) The Overload light indicates an output  
wiringshortcircuitoraloadthatistoolargeforthe  
power rating of the inverter. Switch the inverter  
“Off”, remove the short circuit or excessive load  
from the output, then switch the inverter back  
“On”.  
c) TheHightemp. lightindicatestheinverter  
has overheated. The unit will automatically turn  
back on when it has cooled to 400C (1040F).  
5.03 If the above steps are completed and the  
inverterstillwillnotoperatesatisfactorilycallAirpax  
Dimensions,Inc.forareturnauthorizationnumber.  
4. START UP / OPERATION  
4.01 To operate the inverter turn the remote  
switch to “On”. Makesurethattheoutputbreakeris  
reset.  
4.02 Turn the switch to “Off” when the inverter  
is not in use.  
5. TROUBLESHOOTING  
5.01 Airpax Dimensions Inc. offers free phone  
consultationconcerninginstallationortroubleshoot-  
ing. Call the Customer Service Department at:  
1-800-553-6418 or 1-651-653-7000  
Fax:651-653-7600;  
5.02 If the inverter fails to operate correctly,  
use the following troubleshooting procedure.  
Page 4  
 
FRONT VIEW  
WIRING DIAGRAM FOR MODEL 48Z8NV  
Note 1: Remote switch to be connected to +12VDC, +24VDC or +48VDC depending on inverter model.  
Output Breaker  
Inv. Power  
Fig #1  
Low battery  
Overload  
Hightemp.  
Dimensions  
GFCI  
Chassis  
Bonding Lug  
Remote  
On/Off  
Battery  
Input  
A.C.  
Output  
Ground  
Remote  
On/Off  
Switch  
120VAC, 60Hz  
Output  
Fuse  
Fuse  
Red (+)  
Black (-)  
+
-
+
-
+
-
+
-
12VDC  
12VDC  
12VDC  
12VDC  
Four batteries in series  
Page 5  
 
Limited Warranty Terms & Conditions  
SHIPPING TERMS  
F.O.B. St. Paul Minnesota. Freight prepaid and billed, subject to prior credit approval.  
MINIMUM ORDER  
$50.00 Net Price  
LOSS OR DAMAGE  
Loss or damage in transit are the responsibility of the carrier. Any claim should be filed with the delivering transport company. Invoice, Bill of  
Lading and Delivery receipt with damage noted therein must accompany any claims for freight damage. Claims for shortage and lost shipments  
must be made in writing to Airpax Dimensions, St. Paul, MN within 10 days of date of shipment. Claims not reported within this time frame will  
notbehonored.  
PRICES  
Prices are subject to change without notice. All orders are subject to acceptance at the factory. We reserve the right to invoice prices in effect  
at time of shipment.  
TERMS  
Net 30 days with approved credit, credit card or C.O.D.  
RETURN GOODS POLICY  
• No returned materials will be accepted without an accompanying Returned Materials Authorization Number (RMA) from the factory.  
• Credit will be issued for returned goods to the original purchaser within 60 days of purchase, provided the inverter is returned to Dimensions  
unused and not mounted. The amount of credit will be issued at Dimensions discretion based on the condition of the product.  
• Customer must be in good standing with Dimensions.  
• Inverters that are discontinued, special-order or used are excluded and will not be eligible for credit. Non-inverter items such as cable  
assemblies, fuses and fuse holders, will not be eligible for credit  
• Support components supplied by Dimensions vendors will be covered under that manufacturer’s credit return policy.  
• Customer pays return freight.  
PLEASE SHIP AUTHORIZED RETURNS TO: Airpax Dimensions, Inc. / 4467 White Bear Parkway / St. Paul, MN 55110  
ReturnFreightPrepaid  
LIMITED WARRANTY  
Airpax Dimensions, Inc. extends the following warranty to the original purchaser of those goods subject to the qualifications indicated.  
Dimensions warrants to the original purchaser for use that the goods or any component thereof manufactured by Dimensions will be free from  
defects in workmanship from the date of purchase for the period listed on the product label, provided such goods are installed, maintained  
and used in accordance with Dimensions and the original manufacturer’s written instructions.  
Components not manufactured by Dimensions, but used within the assembly provided by Dimensions, are subject to the warranty period as  
specifiedbytheindividualmanufacturerofsaidcomponent,providedsuchgoodsareinstalled,maintainedandusedinaccordancewithDimensions  
and the manufacturer’s written instructions.  
Dimensions sole liability and the Purchaser’s sole remedy for a failure of goods under this limited warranty and for any and all claims arising out  
of the purchase and use of the goods, shall be limited to the repair or replacement of the goods that do not conform to this warranty. The  
return of the purchase price in cash is at the sole discretion of Dimensions.  
To obtain repair or replacement service under the limited warranty, the purchaser must contact the factory for a Return Material Authorization  
(RMA). Once obtained, send the Return Material Authorization Number along with the defective part or goods to: Airpax Dimensions, Inc., 4467  
White Bear Parkway, St. Paul, MN 55110, freight prepaid.  
THERE ARE NO EXPRESS WARRANTIES COVERING THESE GOODS OTHER THAN AS SET FORTH ABOVE. THE IMPLIED WARRANTIES OF  
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO ONE YEAR FROM DATE OF PURCHASE.  
DIMENSIONS ASSUMES NO LIABILITY IN CONNECTION WITH THE INSTALLATION OR USE OF THE PRODUCT, EXCEPT AS STATED IN THIS  
LIMITED WARRANTY. DIMENSIONS WILL IN NO EVENT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.  
WARNING: LIMITATIONS ON USE  
Dimensions products are not intended for use in connection with Life Support Systems and for Avionic use. Dimensions makes no warranty or  
representation in connection with their products for such uses.  
Page 6  
 

Belkin Network Card P75481 User Manual
Bissell Hot Beverage Maker 29H3 User Manual
Black Box Switch DVI Switches User Manual
Black Decker Blender BLP7600BF User Manual
BMW Automobile 01 41 0 157 980 User Manual
Califone MP3 Player 2396 User Manual
Campbell Hausfeld Paint Sprayer AL2150 User Manual
Canon Calculator P27 DH User Manual
Canon Camera Lens 4426B002 User Manual
Chauvet Stereo Equalizer TFX 24C User Manual