C&H Technologies, Inc. • 445 Round Rock West Drive • Round Rock, TX 78681-5012
VX405C
M/MA Module
Carrier
The VX405C carrier provides the
mechanical and electrical interfaces
between the VXIbus and up to six
(6) VITA 12-1996 standard M/MA
Modules. The carrier provides VXI
register configuration and access to
the M/MA modules I/O space and
memory (if present). Each M/MA
module is controlled separately and
appears as a different Logical
Address in the VXI environment.
Over 200 M/MA modules are
available that can provide custom
interfacing to the unit under test
(UUT). Up to six (6) unique
instruments or interfaces may be
provided in a single VXI slot.
VXIbus Compliance
Specifications:
Complies with ANSI/IEEE Std 1014-
1987, IEC8921, and VXIbus Rev 1.4
Number of M/MA Modules
Carried:
• Up to six(6). Each appears as an
independent VXI instrument.
Connectors:
• Each M/MA Module has its own
front panel and connectors.
A16/24/32:D8/16/32 Slave
SYSFAIL: Supported
Indicators:
MODID
Unique Logical Address for each
M/MA Module:
• Can be configured for sequential
numbering or Modulo-8 numbering
for Agilent Command Module
compatibility.
SYSFAIL
Interrupts: ROAK, programmable
levels
M/MA Module Access (6)
BRX tied to BGX
Power:
+5V @ 1.3 A typical
Plus M/MA Power
TTL Triggers: Supports I/O
synchronous (SYNC) trigger
protocol
+12V and –12V provided to the
M/MA Modules but not used
by the carrier.
M/MA Module Triggers:
• TRIGA or TRIGB of M/MA module
may be connected to any VXI TTL
Trigger under software control.
Form Factor: Size C
Applications
M/MA Module Interrupts:
• Each module interrupt can have a
software programmable VXI IRQ
level.
• Multiple instrument types in a
single VXI slot.
Ordering Information
• Port customer interfaces from ITA
to a VXI slot
Description
Part Number
M/MA Module Identification:
• M/MA IDENT function supported.
M/MA Mod. Carrier 11027050-0001
• VXI ATE “glue logic”
|