Black Box Computer Accessories Cable Length Meter User Manual

December 2009  
CLM5000  
Cable Length Meter  
Use to measure cable length and generate tone  
on industrial, telco, and coax cable (not CATx).  
Works on single- or two-conductor cables.  
Compact, handheld unit.  
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call  
724-746-5500) • FREE technical support 24 hours a day, 7 days a  
week: Call 724-746-5500 or fax 724-746-0746 • Mailing address:  
Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 •  
Customer  
Support  
Information  
 
FCC and IC RFI Statements  
FEDERAL COMMUNICATIONS COMMISSION  
AND INDUSTRY CANADA  
RADIO FREQUENCY INTERFERENCE STATEMENTS  
This equipment generates, uses, and can radiate radio-frequency energy, and if  
not installed and used properly, that is, in strict accordance with the manufacturer’s  
instructions, may cause interference to radio communication. It has been tested  
and found to comply with the limits for a Class A computing device in accordance  
with the specifications in Subpart B of Part 15 of FCC rules, which are designed  
to provide reasonable protection against such interference when the equipment  
is operated in a commercial environment. Operation of this equipment in a  
residential area is likely to cause interference, in which case the user at his own  
expense will be required to take whatever measures may be necessary to correct the  
interference.  
Changes or modifications not expressly approved by the party responsible  
for compliance could void the user’s authority to operate the equipment.  
This digital apparatus does not exceed the Class A limits for radio noise emission  
from digital apparatus set out in the Radio Interference Regulation of Industry  
Canada.  
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant  
les limites applicables aux appareils numériques de classe A prescrites dans le  
Règlement sur le brouillage radioélectrique publié par Industrie Canada.  
WEEE Directive Compliance (RoHS)  
This product complies with the Waste Electrical and Electronic Equipment (WEEE)  
Directive, 2 002 /96/EC. It should not be disposed of as unsorted municipal waste  
and should be collected separately and disposed of according to your national  
regulations.  
724-746-5500  
|
blackbox.com  
Page 1  
 
Cable Length Meter  
Normas Oficiales Mexicanas (NOM)Electrical Safety Statement  
INSTRUCCIONES DE SEGURIDAD  
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes  
de que el aparato eléctrico sea operado.  
2. Las instrucciones de seguridad y operación deberán ser guardadas para  
referencia futura.  
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de  
operación deben ser respetadas.  
4. Todas las instrucciones de operación y uso deben ser seguidas.  
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca  
de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc.  
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que  
sean recomendados por el fabricante.  
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea  
recomendado por el fabricante.  
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a  
lo descrito en las instrucciones de operación. Todo otro servicio deberá ser  
referido a personal de servicio calificado.  
9. El aparato eléctrico debe ser situado de tal manera que su posición no  
interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá,  
alfombra o superficie similar puede bloquea la ventilación, no se debe colocar  
en libreros o gabinetes que impidan el flujo de aire por los orificios de  
ventilación.  
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor  
como radiadores, registros de calor, estufas u otros aparatos (incluyendo  
amplificadores) que producen calor.  
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del  
tipo descrito en el instructivo de operación, o como se indique en el aparato.  
724-746-5500  
|
blackbox.com  
Page 2  
 
NOM Statement  
12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización  
del equipo no sea eliminada.  
13. Los cables de la fuente de poder deben ser guiados de tal manera que no  
sean pisados ni pellizcados por objetos colocados sobre o contra ellos,  
poniendo particular atención a los contactos y receptáculos donde salen del  
aparato.  
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las  
recomendaciones del fabricante.  
15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas  
de energia.  
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea  
usado por un largo periodo de tiempo.  
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean  
derramados sobre la cubierta u orificios de ventilación.  
18. Servicio por personal calificado deberá ser provisto cuando:  
A: El cable de poder o el contacto ha sido dañado; u  
B: Objectos han caído o líquido ha sido derramado dentro del aparato; o  
C: El aparato ha sido expuesto a la lluvia; o  
D: El aparato parece no operar normalmente o muestra un cambio en su  
desempeño; o  
E: El aparato ha sido tirado o su cubierta ha sido dañada.  
724-746-5500  
|
blackbox.com  
Page 3  
 
Cable Length Meter  
Trademarks Used in This Manual  
Black Box and the Double Diamond logo are registered trademarks of  
BB Technologies, Inc.  
Any other trademarks mentioned in this manual are acknowledged to be the  
property of the trademark owners.  
724-746-5500  
|
blackbox.com  
Page 4  
 
Table of Contents  
Chapter  
Page  
1. Specifications..............................................................................6  
2. Overview ....................................................................................8  
2.1 Introduction..........................................................................8  
2.2 Features................................................................................8  
2.3 What’s Included ...................................................................9  
2.4 Hardware Description...........................................................9  
3. General Functions.....................................................................10  
3.1 PWR Key and Auto Power Off...........................................10  
3.2 Mode Key...........................................................................10  
3.3 AL/CU Units Key ................................................................10  
3.4 LCD Display Icons ............................................................... 11  
4. Using the Cable Length Meter.................................................12  
4.1 AWG Mode........................................................................12  
4.2 Pair SGL Key .......................................................................14  
4.3 Coax, Network, and Telco Modes......................................16  
4.4 Tone Mode.........................................................................18  
4.5 Calibrating the Test Lead....................................................19  
5. Installing the Battery.................................................................21  
6. Troubleshooting........................................................................22  
6.1 Calling Black Box................................................................22  
6.2 Shipping and Packaging.....................................................22  
724-746-5500  
|
blackbox.com  
Page 5  
 
Cable Length Meter  
1. Specifications  
Cable Types: Single or dual conductor, 8–30 AWG, network, coax, and telco  
Temperature Tolerance: Operating: 32 to 122° F (0 to 50° C);  
Storage: +14 to +140°F (-10 to +60° C)  
Humidity: 10 to 90%, noncondensing  
Power: (1) 9-V alkaline battery: Standby: 2.5 years;  
Cable Testing: 20 hours into 60-ohm load (smaller resistance loads will result in  
shorter battery life)  
High-Voltage Protection: 120 VAC maximum  
Size: 1.3"H x 3"W x 6"D (3.3 x 7.6 x 15.2 cm)  
Weight: 11.5 oz. (326 g)  
Table 1-1. Length measurement range opens (maximum 0.082 µF capacitance).  
Wire Type  
Telecom  
Typical  
Capacitance  
per foot  
Length, ft. (m) Tolerance  
17.5 pf  
15 pf  
0–4500 ft.  
(1371 m)  
Minimum cable  
length 3 ft. (0.91 m) 2%,  
+3 digits LSD*  
Network wire  
Coax  
5000 ft.  
(1524 m)  
Minimum cable length  
3 ft. (0.91 m) 2%,  
+3 digits LSD  
22 pf  
3500 ft.  
(1066 m)  
Minimum cable length  
3 ft. (0.91 m) 2%,  
+3 digits LSD  
*LSD = Least significant digit  
724-746-5500  
|
blackbox.com  
Page 6  
 
Chapter 1: Specifications  
Table 1-2. Length measurement range DC (resistance 0–635 ohms).  
AWG  
Min. (ft.)  
Length  
Tolerance  
8, 10  
5.0  
0-9999 ft.  
(3047 m)  
2%, 3 LSD*  
12, 14, 16  
18, 20, 22  
24, 26, 28  
30  
4.0  
3.0  
1.0  
1.0  
0–9999 ft.  
(3047 m)  
2%, 3 LSD  
2%, 3 LSD  
2%, 3 LSD  
2%, 3 LSD  
0–9999 ft.  
(3047 m)  
0–9999 ft.  
(3047 m)  
0–5879 ft.  
(1792 m)  
*LSD = Least significant digit  
724-746-5500  
|
blackbox.com  
Page 7  
 
Cable Length Meter  
2. Overview  
2.1 Introduction  
The Cable Length Meter for industrial, network, telco, and coax cable (not CATx) is  
an easy-to-use, versatile compact handheld unit that measures cable length and  
generates tone. It works on single- or two-conductor cables for testing and trouble-  
shooting.  
CAUTION: Do not attach test leads to energized cables. The Cable Length Meter  
might be damaged.  
2.2 Features  
• Measures the distance to an open or the distance to a short  
• Operates in six modes: AWG/mm/mm2, Telco, Network, Coax, Tone Generator,  
and Ohms  
• Measures one- or two-pair conductor lengths in feet or meters  
• Includes an audible indicator for shorted wires  
• Has a large LCD that‘s easy to read in sunlight  
• Measures wires 8 to 30 AWG (3.264 mm/8.366 mm2 to 0.255m/0.051 mm2)  
• Provides copper (CU) or Aluminum (AL) wire measurements  
• Protects voltages up to 120 VAC  
• Features 12 preset wire gauge settings  
• Choose from 12 user-programmable wire gauge settings  
• Provides four selectable tones  
• Requires a 9-volt battery (not included)  
• Enables auto shutdown  
• Supports resistance from 0 to 635 ohms  
• Measures opens/capacitance from 0 to 0.82 µf (approximately 5K feet)  
• Features milliohm resolution  
• CE certified  
724-746-5500  
|
blackbox.com  
Page 8  
 
Chapter 2: Overview  
2.3 What’s Included  
• (1) Cable Length Meter  
• (1) double-banana to BNC + BNC F to F jack  
• (2) test leads  
• (2) clips  
• (1) carrying pouch  
2.4 Hardware Description  
Figure 2-1 illustrates the Cable Length Meter.  
6. Heavy-Duty  
Test Leads  
7. Mode Select  
Button  
1. Large LCD Display  
2. Test Lead  
Calibration Button  
8. Copper/Aluminum  
Distance Button  
3. Up Button  
9. Down Button  
4. Power Button  
10. Set Wire  
Length Button  
5. Pair/Single  
Conductor Button  
Figure 2-1. Cable Length Meter.  
724-746-5500  
|
blackbox.com  
Page 9  
 
Cable Length Meter  
3. General Functions  
3.1 PWR Key and Auto Power Off  
Press the PWR key to turn the unit on and off. If no keys have been pressed, the  
Cable Length Meter powers off automatically after 10 minutes. The timer resets  
every time you press a key. In Tone mode, the unit will automatically power off after  
1 hour.  
3.2 Mode Key  
The Cable Length Meter operates in eight modes. Press the “Mode” key to cycle  
through the various modes:  
AWG/mm/mm2 mode: measures cable length in AWG/mm/mm2, feet/meters,  
copper/aluminum  
Coax mode: measures cable length, distance to opens, or distance to short  
Telco mode: measures cable length, distance to opens or distance to short  
Network: measures cable length, distance to opens, or distance to short  
Ohm: measures resistance from 0 to 635 ohms  
Tone: generates four different tones  
3.3 AL/CU Units Key  
The AL/CU key functions in two ways.  
Function #1: Press the AL/CU/Units key to select wire alloy type: copper (CU) or  
aluminum (AL). When selected, the ALor “CU” icon will light in the lower right  
corner of the display.  
Function #2: Hold the AL/CU/Units key down for approximately 1.5 seconds. The  
unit will toggle between “Feet” or “Meters. When selected, the “FT” or“M” icon  
will light in the center right hand side of the screen.  
724-746-5500  
|
blackbox.com  
Page 10  
 
Chapter 3: General Functions  
3.4 LCD Display Icons  
Table 3-1 describes the icons that appear on the LCD display.  
Table 3-1. LCD display icons.  
Icon  
Description  
Coax mode  
Telco mode  
Network mode  
Tone mode  
Two-conductor icon (AWG/mm/mm2 mode)  
One-conductor icon (AWG/mm/mm2 mode)  
Short symbol, indicates the presence of a short  
between two conductors. An audible tone is  
also generated. (Coax, Telco, and Network  
mode)  
Unit detects voltage on the line  
Battery low icon. The Cable Length Meter mon-  
itors the battery status continuously when it is  
powered on. When the battery low icon is acti-  
vated, the unit has approximately 15 minutes of  
battery life. Replace the battery as soon as pos-  
sible. If the 15-minute period is exceeded, then  
cable testing results will become unreliable.  
724-746-5500  
|
blackbox.com  
Page 11  
 
Cable Length Meter  
4. Using the Cable Length Meter  
4.1 AWG Mode  
This mode allows length measurements from 8 to 30 AWG (8, 10, 12, 14, 16, 18,  
20, 22, 24, 26, 28, and 30 AWG). Use the UP/DOWN keys to scroll through the  
various wire gauges. Select from copper or aluminum type wires and meters or feet.  
Figure 4-1 shows a typical AWG Mode screen.  
Figure 4-1. AWG Mode screen.  
724-746-5500  
|
blackbox.com  
Page 12  
 
Chapter 4: Using the Cable Length Meter  
Table 4-1. AWG/mm/mm2 cross-reference data.  
AWG  
#8  
Diameter (mm)  
3.264  
2.906  
2.588  
2.305  
2.053  
1.828  
1.628  
1.450  
1.291  
1.150  
Area (mm2)  
8.37  
#9  
6.63  
#10  
#11  
#12  
#13  
#14  
#15  
#16  
#17  
#18  
#19  
#20  
#21  
#22  
#23  
#24  
#25  
#26  
#27  
#28  
#29  
#30  
5.26  
4.17  
3.31  
2.62  
2.08  
1.65  
1.31  
1.04  
1.024  
0.823  
0.653  
0.518  
0.410  
0.326  
0.258  
0.205  
0.162  
0.129  
0.102  
0.081  
0.064  
0.051  
0.912  
0.812  
0.723  
0.644  
0.573  
0.511  
0.455  
0.405  
0.361  
0.321  
0.286  
0.255  
724-746-5500  
|
blackbox.com  
Page 13  
 
Cable Length Meter  
4.2 Pair SGL Key  
The Cable Length Meter can measure single- or two-conductor wires. Press the  
PAIR SGL key to toggle between single or two conductor. For single-conductor  
measurement, the unit is connected at both ends of the wire/conductor. For two-  
conductor measurements, the unit is connected one end of the wire and the other  
end of the pair is shorted (wire length = total resistance/2).  
SET LEN Key (AWG Mode Example)  
The Set Length function allows the user to change factory default ohms per feet  
coefficients values, based on a sample length of wire. Press the SET LEN key to tog-  
gle between the AWG Mode screen (Figure 4-1) and the Set Length Mode screen  
(Figure 4-2, below). In Set Length mode, the unit measures the sample wire’s resis-  
tance. Press the UP/DOWN keys to adjust the wire length from 100 to 200 feet  
(31.3 to 62.5 m). The smaller digits display ohms per feet, based on the sample wire.  
Press and hold the SET LEN key down for a few seconds to store the new coeffi-  
cients and override factory default values.  
Figure 4-2. Set Length Mode screen.  
Example: The factory default for 12 AWG copper is .0017 ohms/feet.  
1. Using the MODE key, select AWG mode.  
2. Using the UP/DOWN keys, set the AWG to 12.  
724-746-5500  
|
blackbox.com  
Page 14  
 
Chapter 4: Using the Cable Length Meter  
3. Press the SET LEN (LEN = Length) key, and the Set Length screen (Figure 4-2)  
appears. In this mode, use the UP/DWN keys to adjust the larger digits to match  
the length of the sample wire (100–200 ft. range). If the sample wire is 150 feet  
and its resistance is equal to 0.315 ohms, the smaller digits on the left-hand side  
of the screen will display “0.0021 ohms/ft. (150 feet/0.315 ohms = 0.0021 ohms/  
ft.)  
4. To store the new value, press the SET LEN key for approximately 1.5 seconds. The  
unit generates a confirmation beep. The new 12 AWG length coefficient of  
0.0021 ohms/feet will be stored in memory in place of the factory default of  
0.0017 ohms/feet.  
NOTE: Restoring Factory Default Values. To restore factory coefficients back to  
their original values, hold the UP/DOWN keys and the Power key down at  
the same time when powering down the unit. Any previous values stored by  
the user will be deleted from memory. Table 4-2 lists the factory default  
values.  
Table 4-2. Factory default values, ohms/feet.  
AWG  
Aluminum  
Copper  
8
0.00103  
0.00164  
0.00261  
0.00414  
0.00659  
0.0105  
0.0167  
0.0265  
0.0421  
0.067  
0.00063  
0.0011  
0.0017  
0.0025  
0.00455  
0.0061  
0.00945  
0.0168  
0.0273  
0.0436  
0.0637  
0.108  
10  
12  
14  
16  
18  
20  
22  
24  
26  
28  
30  
0.106  
0.169  
724-746-5500  
|
blackbox.com  
Page 15  
 
Cable Length Meter  
4.3 Coax, Network, and Telco Modes  
Coax, Network, and Telco modes detect the distance to opens and the distance to  
shorts.  
The Cable Length Meter determines the length by measuring line capacitance when  
the line is open or by measuring resistance when the line is shorted. When measur-  
ing opens, use the UP/DOWN keys to adjust the capacitance coefficient (10 to 40  
pf per feet) to calculate the cable length. The Cable Length Meter supports three  
user-adjustable length coefficients, one for each type of cable (Coax, Network and  
Telco). It stores these coefficients in memory even when the unit is powered off.  
Short/Resistance coefficients are stored in memory (see Table 4-2 for factory default  
values). These values can be changed by running the Set Length Function. The Set  
Length function allows the user to change factory default values, ohms per feet  
coefficients, based on a sample known length of wire. Press the SET LEN key to  
toggle between Normal Measuring screen (Figure 4-3) and Set Length Mode screen,  
Figure 4-4. In Set Length mode (line shorted), the unit will measure the resistance  
of the sample wire. Adjust the length of the sample wire using the UP/DOWN keys  
in the range of 100 to 200 feet. The smaller digits display the ohms per feet based  
on the sample wire. Press and hold the SET LEN key down for a few seconds to  
store the new coefficients.  
Figure 4-3. Normal Network Measuring screen.  
724-746-5500  
|
blackbox.com  
Page 16  
 
Chapter 4: Using the Cable Length Meter  
Example: The factory default for Network wire is .0273 ohms per feet.  
Press the MODE key to select Network mode.  
Press the SET LEN (LEN = Length) key, and a new screen will pop up (see Figure  
4-4). In this mode, use the UP/DOWN keys to adjust the larger digits to match the  
length of the sample wire (100–200 feet range). If the sample wire is 150 feet and  
its resistance is equal to .315 ohms, the smaller digits on the left hand side of the  
screen will display “002.1m.  
To store the new value, press the SET LEN key for approximately 1.5 seconds. The  
unit will generate a confirmation beep. The unit stores the new network length  
coefficient of .0021per feet in memory.  
Figure 4-4. Set Length Mode screen.  
NOTE: Restoring Factory Default Values. To restore ohms per feet factory coeffi-  
cients back to their original values, hold the Power and UP/DOWN keys  
down at the same time while powering down the unit. Any previously stored  
values will be overwritten by the factory default values.  
NOTE: To obtain symmetrical test results for Shorts and Opens measurements, the  
Cable Length Meter must have the correct “capacitance per feet coef-  
fiecient” and “resistance per feet coefficient“ of the wire under test.  
724-746-5500  
|
blackbox.com  
Page 17  
 
Cable Length Meter  
Changing Opens/Capacitance Coefficient Using Set Length  
To change capacitance coefficients, follow the steps above (cable/wire must be  
open) based on the sample wire (100 to 200 feet). The Cable Length Meter  
measures the total capacitance of the cable and displays the value in the lower left-  
hand corner of the LCD (the cable must be within 10 to 40 pf per feet range, other-  
wise meter will indicate OL).  
Table 4-3. Opens/shorts factory default values.  
Mode  
Coax  
Capacitance Opens  
22.0 pf  
Ohms per Feet/AWG Shorts  
0.0663 ohms/NA  
Network  
Telco  
15.0 pf  
0.0273 ohms/24 AWG  
0.0273 ohms/24 AWG  
17.5 pf  
Figure 4-5. BNC-to-F connection for measuring coax.  
4.4 Tone Mode  
To generate a tone on the cable/wire, select Tone Mode (see Figure 4-6). The Cable  
Length Meter has four unique tones. Use the UP/DOWN keys, to scroll through the  
four tones. The tones generated match audio frequencies used with tone tracers/  
probes. The signal generated on a pair is nominal 5 volts peak-to-peak across the  
pair. The unit will power down automatically after 1 hour.  
Available tones include:  
1. High tone 1 KHz  
2. Low tone 704 Hz  
3. Warble tones, low tone for 160 ms, followed by 115 ms of high tone  
724-746-5500  
|
blackbox.com  
Page 18  
 
Chapter 4: Using the Cable Length Meter  
4. Warble tones, low tone for 365 ms, followed by 65 ms of high tone.  
Figure 4-6. Tone Mode screen.  
4.5 Calibrating the Test Lead  
1. Hold down the LEAD CAL key until the unit displays CAL. The unit will display  
CAL for a few seconds then display Shrt Lead.  
2. Short the leads as illustrated Figure 4-7. Once connected properly to the bus wire,  
press the LEAD CAL key again. The unit will beep and display OPEN LEAD.  
3. Disconnect the leads from the short. With the test leads open, press the LEAD  
CAL button. The unit will be beep and go into its normal operation mode. This  
completes the calibration procedure. This procedure must be done correctly for  
good measuring results.  
724-746-5500  
|
blackbox.com  
Page 19  
 
Cable Length Meter  
Test Clips  
8–14 AWG  
Bus Wire  
Test Clips  
Figure 4-7. Wire under test.  
NOTE: Make sure the wire surface is clean and the clips are making good contact.  
For best results, use solid wire 8 to 14 AWG. Make sure clips are as close  
together as possible.  
724-746-5500  
|
blackbox.com  
Page 20  
 
Chapter 5: Installing the Battery  
5. Installing the Battery  
Batteries are not included. Use only an alkaline 9-volt battery. When installing a new  
battery, disconnect any test cables connected to the Cable Length Meter. (See  
Figure 5-1.)  
1. Using a #2 Phillips screwdriver, unscrew the battery cover screw and remove the  
battery cover on the back of the unit.  
2. Remove the old battery from the battery compartment and detach the battery cap.  
3. Connect a new alkaline 9-volt battery to the battery cap.  
4. Slide the battery into the cavity.  
5. Close the battery cover and replace the screw. Do not overtighten.  
Battery  
cover screw  
Battery  
cover  
Cable Length  
Meter, back view  
Figure 5-1. Battery installation.  
724-746-5500  
|
blackbox.com  
Page 21  
 
Cable Length Meter  
6. Troubleshooting  
6.1 Calling Black Box  
If you determine that your Cable Length Meter is malfunctioning, do not attempt to  
alter or repair the unit. It contains no user-serviceable parts. Contact Black Box  
Technical Support at 724-746-5500.  
Before you do, make a record of the history of the problem. We will be able to  
provide more efficient and accurate assistance if you have a complete description,  
including:  
• the nature and duration of the problem.  
• when the problem occurs.  
• the components involved in the problem.  
• any particular application that, when used, appears to create the problem or make  
it worse.  
6.2 Shipping and Packaging  
If you need to transport or ship your Cable Length Meter:  
• Package it carefully. We recommend that you use the original container.  
• If you are returning the unit, make sure you include everything you received with  
it. Before you ship for return or repair, contact Black Box to get a Return  
Authorization (RA) number.  
724-746-5500  
|
blackbox.com  
Page 22  
 
NOTES  
724-746-5500  
|
blackbox.com  
Page 23  
 
NOTES  
724-746-5500  
|
blackbox.com  
Page 24  
 
NOTES  
724-746-5500  
|
blackbox.com  
Page 25  
 
Black Box Tech Support: FREE! Live. 24/7.  
Tech support the  
way it should be.  
Great tech support is just 20 seconds away  
at 724-746-5500 or blackbox.com.  
About Black Box  
Black Box Network Services is your source for more than 118,000 networking  
and infrastructure products. You’ll find everything from cabinets and racks and  
power and surge protection products to media converters and Ethernet switches  
all supported by free, live 24/7 Tech support available in 20 seconds or less.  
© Copyright 2009. All rights reserved.  
 

BIXOLON Printer SRP F310 User Manual
Blackberry Cell Phone 8703e User Manual
Bosch Appliances Computer Monitor UML 273 90 User Manual
Breville Slow Cooker BTS200 User Manual
Briggs Stratton Pressure Washer HU80530 User Manual
Briggs Stratton Snow Blower 1694919 User Manual
Brinkmann Gas Grill ProSeries 4435 User Manual
Canon Digital Camera 480EG User Manual
Channel Vision Stereo System AB 114 User Manual
Chrysler Automobile SRT6 User Manual