Bertazzoni Cooktop CB36500X User Manual

Installation, Service and User Instructions  
Built-in gas cooktops  
BERTAZZONI  
DIMENSIONS: 36’’ (915 mm)(W) x 253/16’’ (640 mm)(D)  
Models  
Models  
CB36500X  
CB36600X  
[C3W0..U7X (2 or 5)A]  
[C3Y0..U7X(2 or 5)A]  
IMPORTANT - PLEASE READ AND FOLLOW  
-Before beginning installation, please read these instructions completely and carefully.  
-Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty. -Please observe all local  
and national codes and ordinances.  
-Please ensure that this product is properly grounded.  
-The installer should leave these instructions with the consumer who should retain for local inspector's use and for  
future reference.  
-The electrical plug should always be accessible.  
Installation must conform with local codes or in the absence of codes, the National Fuel Gas Code ANSIZ223.1-latest edition. Electrical  
installation must be in accordance with the National Electrical Code, ANIS/NFPA70 - latest edition and/or local codes. IN CANADA:  
Installation must be in accordance with the current CAN/CGA-B149.1 National Gas Installation Code or CAN/CGA-B 149.2, Propane  
Installation Code and/or local codes. Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical  
Codes Part 1 and/or local codes.  
Installation of any gas-fired equipment should be made by a licensed plumber. A manual gas shut-off valve must be installed in the gas  
supply line ahead of the oven in the gas flow for safety and ease of service.  
In Massachusetts: All gas products must be installed by a "Massachusetts" licensed plumber or gasfitter. A "T" handle type manual  
gas valve must be installed in the gas supply line to this appliance.  
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR’S USE.  
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.  
OBSERVE ALL GOVERNING CODES AND ORDINANCES.  
WARNING: If the information in this manual is not followed exactly, a  
fire or explosion may result causing property damage, personal injury  
or death.  
Do not store or use gasoline or other flammable vapors and liquids in  
the vicinity of this or any other appliance.  
WHAT TO DO IF YOU SMELL GAS  
- Do not light any appliance.  
- Do not touch any electrical switch.  
- Do not use any phone in your building.  
- Immediately call your gas supplier from a neighbor’s phone. Follow  
the gas supplier’s instructions.  
- If you cannot reach your gas suppliers, call the fire department.  
Installation and service must be performed by a qualified installer,  
service agency or the gas supplier.  
310496  
 
INSTALLATION MANUAL  
WORKTOP FRONTGUARD INSTALLATION INSTRUCTIONS  
In order to increase the clearance between front edge of the worktop and the burners for your safety it is  
recomended to install the worktop frontguard supplied with the appliance. For installation instructions follow  
the instructions indicated in the following figures  
3
 
PROXIMITY TO SIDE CABINET INSTALLATION  
1. This rangetop may be installed directly adjacent to existing 36" (91.5 cm) high base cabinets. IMPORTANT: The top  
grate support MUST be 3/8" (.95 cm) above the adjacent base cabinet countertOP.  
2.The rangetop CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical  
surfaces above 36" (91.5 cm) high. There must be a minimum of 6" (15.2 cm) side clearance from the rangetop to  
such combustible surfaces above the 36" (91.5 cm) counter height.  
3.3. Within the 6" (15.2 cm) side clearance to combustible vertical surfaces above 36" (91.4 cm) I the maximum wall  
cabinet depth must be 13" (33.0 cm) and wall cabinets within this 6" (15.2 cm) side clearance must be 18" (45.7 cm)  
above the 36" (91.4 cm) high countertop.  
4.4. Wall cabinets above .the rangetop must be a minimum of 36" (91.4 cm) for the open top burner models and a  
minimum of 42" (106.7 cm) for the sealed burner models above the rangetop cooking surface for the full width of the  
rangetop. This minimum height requirement does nQ1 apply if a rangehood is installed over the cooking surface.  
A
B
C
D
E
F
6”(15.2cm) MIN  
36”(91.5cm)  
36”(91.5cm)  
13”(33.0cm)MAX  
18”(45.7cm)MIN  
36”(91.5cm)  
G
H
i
6”1/2(16.5cm)  
1”(2.5cm) MIN  
9/16” (1.8cm)  
2”( 5 cm) MIN  
L
120 VAC/60 Hz withing  
48” (122.9cm) of right  
rear or rangetop  
4
 
COOKER HOOD INSTALLATION  
The bottom of the hood should be 25 ½ " (65 cm) min. to 31 ½ " (80 cm) above the countertop. Refer to the rangehood  
installation instructions for additional information. These dimensions provide for safe and efficient operation of the hood.  
ELECTRICAL CONNECTION  
This unit is manufactured for a polarized, grounded 120 volt/60 Hz, 16 amp system. Electric power consumption is about  
1 W. The minimum of 102 VAC is required for proper operation of gas ignition systems. This circuit must be grounded  
and properly polarized. The unit is equipped witth a SJT power cord, and in case of replacement, the cable shall be  
replaced with one of the same type, size and length.  
WARNING  
Electrical Grounding Instructions  
This appliance is equipped with a three prong plug for your protection against shock hazard and should be plugged  
directly into a properly grounded socket. Do not cut or remove the grounding prong from this plug.  
WARNING  
ELECTRICAL SHOCK HAZARD  
Disconnect electrical power at the circuit breaker box or fuse before installing the appliance  
Electrically ground appliance  
Use copper conductors only. Failure to follow these instructions could result in seriuos injury or death  
5
 
Wiring diagram  
For freestanding gas range model CB36600X  
C3Y0..U7X(2 or 5)A  
CAUTION: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper  
and dangerous operation. Verify proper operation after servicing.  
For freestanding gas range model CB36500X  
C3W0..U7X(2 or 5)A  
CAUTION: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper  
and dangerous operation. Verify proper operation after servicing.  
6
 
GAS CONNECTION  
All gas connections must be made according to national and local codes. This gas supply (service) line must be the  
same size or greater than the inlet line of the appliance. This range uses a 1/2" NPT (see fig. in this chapter for details of  
gas connections installations) inlet. Sealant on ali pipe joints must be resistive to LP gas.  
1. Manual Shut-off Valve:  
This installer-supplied valve must be installed in the gas service line ahead of the appliance in the gas stream and in  
a position where it can be reached quickly in the event of an emergency. The manual shut-off valve shall be installed  
properly in order to be accessible when appliance is installed in definitive position. In Massachusetts: A 'T' handle  
type manual gas valve must be installed in the gas supply line to this appliance.  
2. Pressure Regulator (see fig. in this chapter)  
a) All cooking equipment must have a pressure regulator on the incoming service line for safe and efficient  
operation, since service pressure may fluctuate with local demand. The pressure regulator is supplied  
separately with the appliance; regulator has two female threads ½” NPT; it shall be installed properly in order  
to be accessible when appliance is installed in definitive position.  
b) Any conversion required must be performed by your dealer or a qualified licensed plumber or gas service  
company. Please provide the service person with this manual before work is started on the range. (Gas  
conversions are the responsibility of the dealer or end user.)  
c) This range can be used with Natural or LP/Propane gas. It is shipped from the factory adjusted for use with  
natural gas.  
d) Manifold pressure should be checked with a manometer, natural gas requires 4.0" W.c.P. and LP/Propane  
requires 11.0" W.C.P. Incoming line pressure upstream from the regulator must be 1" W.c.P. higher than the  
manifold pressure in order to check the regulator. The regulator used on this range can withstand a  
maximum input pressure of 1/2 PSI (14.0" W.c.P.) If the line pressure is in excess of that amount, a step-  
down regulator will be required.  
e) The appliance, its individuai shut-off valve, and pressure regulator must be disconnected from the gas  
supply piping system during any pressure testing of that system at pressures in excess of 1/2 psig (3.45kPa).  
f) The appliance must be isolated from the gas supply piping system by closing its individuai manual shut-off  
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2  
psig (3.45 kPa).  
3. Flexible Connections:  
a) If the unit is to be installed with flexible couplings and/or quick disconnect fittings, the installer must use a  
heavy-duty, AGA design-certified commerciai flexible connector of at least 1/2" (1.3 cm) ID NPT (with  
suitable strain reliefs) in compliance with ANSI Z21.41 and Z21.69 standards.  
b) In Massachusetts: The unit must be installed with a 36" (3-foot) long flexible gas connector.  
c) In Canada: CAN 1-6.10-88 metal connectors for gas appliances and CAN 1-6.9 M79 quick disconnect  
device for use with gas fuel.  
CAUTlON: Leak testing of the appliance shall be conducted according to the manufacturer's instructions. Before placing  
the oven into operation, always check for leaks with a soapy water solution or other acceptable method. DO NOT USE  
AN OPEN FLAME TO CHECK FOR LEAKS!  
PERFORMANCE CHECKLlST  
All burners are tested before leaving the factory. There are no adjustments for the burners if connected according to the  
information on the rating plate. Check each burner for proper operations. Flames should be blue in all settings. If service  
is required, contact your dealer for the name of their authorized servi ce agency. Gas conversions and initial installation  
are not the responsibility of the manufacturer.  
The installer should carry out the following performance checks. Refer to instructions below.  
1. Check surface burner ignition.  
2. Check low flame adjustment – surface burner valve center stem adjustment.  
3. Check for gas leaks (odors) at ali gas connections.  
FINAL PREPARATION  
1. Some stainless steel parts may have a plastic protective wrap which must be removed. The interior of the oven  
should be washed thoroughly with hot. soapy water to remove film residues and any installation dust or debris  
before being used for food preparation, then rinsed and wiped dry. Solutions stronger than soap and water are  
rarely needed.  
2. Ali stainless steel body parts should be wiped with hot, soapy water and with a liquid deaner designed for this  
materia!. If buildup occurs, do not use steel wool. abrasive cloths, cleaners, or powders! If it is necessary to  
scrape stainless steel to remove encrusted materials, soak with hot, wet cloths to loosen the material, then use a  
wood or nylon scraper. Do not use a metal knife, spatula, or any other metal tool to scrape stainless steel!  
Scratches are almost impossible to remove.  
NOTE: These installation instructions should remain with the unit for future reference. The electrical diagram is located in  
the backside or the ccoker  
7
 
REPLACEMENT PARTS  
Only authorized replacement parts may be used in performing service on the appliance. Replacement parts are available  
from factory authorized parts distributors.  
CONVERSIONE TO DIFFERENT TYPES OF GAS  
Before carrying out any maintenance work, disconnect the appliance from the gas and electric  
supply. For Natural Gas fit regulator assembly described in Fig.  
Adaptation of the pressure regulator for use with different type of gas  
The pressure regulator supplied with the appliance is a convertible type pressure regulator for use with Natural Gas at a  
nominal outlet pressure of 4” w.c. or LP gas at a nominal outlet pressure of 11” w.c. and it is pre-arranged from the  
factory to operate with one of these gas/pressure as indicated in the pre-arranging labels affixed on the appliance,  
package and Instruction booklet.  
To convert the regulator for use with the other gas different from which one it is pre-arranged it is enough perform the  
following operations:  
1) Unscrew by hand the upper metal stopper of the regulator.  
2) Unscrew by hand the white plastic piece screwed under the above mentioned metal stopper, afterward screw it again  
in opposite way under the metal stopper (for gas reference see the written “LP” and “NAT” with relative indicating arrows  
on the white piece).  
3) Screw again by hand the metal stopper in the original position on the regulator.  
Operating in this way the gas regulator is converted for use with the other gas/pressure.  
It is essential that the gasket and the pressure test point stopper are properly installed to avoid gas leakage  
- CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS:  
To change the nozzles of the burners use the following procedure:  
Lift up the burners and unscrew the nozzles ( Fig.) using an adjustable spanner of 7 mm and change the nozzles with  
those designed for the new gas supply according to the information given in TABLE shown below.  
8
 
Models CB36600X [C3Y0..U7X(2 or 5)A]  
Adapting to different types of gas  
Burner  
Auxiliary  
Semi-Rapid  
Rapid  
Position  
Injector  
diam. [mm.]  
0,92  
Gas  
Type  
NG  
Pressure  
[i.w.c.]  
4”  
Max Rate  
Min Rate  
[BTU/h]  
900  
900  
1500  
1500  
2500  
2500  
900  
By-pass  
diam. [mm]  
Regulated  
0,29  
Regulated  
0,36  
Regulated  
0,47  
Regulated  
0,29  
[BTU/h]  
[W]  
1098  
1098  
1759  
1845  
[W]  
264  
264  
439  
439  
732  
732  
264  
264  
1319  
1319  
Front R  
3750  
3750  
6000  
6300  
0,56  
1,17  
0,73  
1,55  
LP (Propane)  
11”  
4”  
11”  
4”  
11”  
4”  
11”  
4”  
Rear L & C  
Front C  
Rear R  
NG  
LP (Propane)  
NG  
10400 2046  
11400 3339  
0,98  
LP (Propane)  
Front L Inner  
Front L Outer  
0,80  
0,50  
N°2 x 1,30  
N°2 x 0,83  
NG  
2730  
2900  
799  
8479  
Dual Burner  
LP (Propane)  
NG  
LP (Propane)  
900  
4500  
4500  
15000 4394  
16400 4804  
Regulated  
0,65  
11”  
Models CB36500X  
[C3W0..U7X(2 or 5)A]  
Adapting to different types of gas  
Burner  
Auxiliary  
Semi-Rapid  
Rapid  
Position  
Injector  
diam. [mm.]  
0,92  
Gas  
Type  
NG  
Pressure  
[i.w.c.]  
4”  
Max Rate  
Min Rate  
By-pass  
Diam. [mm]  
Regulated  
0,29  
Regulated  
0,36  
Regulated  
0,47  
Regulated  
0,29  
[BTU/h]  
[W]  
1098  
1098  
1759  
1845  
[BTU/h]  
[W]  
264  
264  
439  
439  
732  
732  
264  
264  
1319  
1319  
Front R  
3750  
3750  
6000  
6300  
900  
900  
0,56  
1,17  
0,73  
1,55  
LP (Propane)  
11”  
4”  
11”  
4”  
Rear L and R  
Front L  
NG  
LP (Propane)  
NG  
1500  
1500  
2500  
2500  
900  
10400 2046  
11400 3339  
0,98  
LP (Propane)  
11”  
Centre Inner  
Centre Outer  
0,80  
0,50  
N°2 x 1,30  
N°2 x 0,83  
NG  
LP (Propane)  
NG  
4”  
11”  
4”  
2730  
2900  
15000 4394  
16400 4804  
799  
8479  
Dual Burner  
900  
4500  
4500  
Regulated  
0,65  
LP (Propane)  
11”  
CAUTION: save the orifices removed from the appliance for future use  
Regulation of burners  
Work surface burner adjustment: follow the instructions below to adjust the work surface burner minimum:  
1) Light the burner and set the knob to the MINIMUM position (small flame).  
2) Remove the knob of the valve that is press fit on the rod of that valve.  
3) The cooker is equipped with safety valves, use a small slotted screwdriver the choke valve located on the valve body  
and turn the choke screw to the right or left until the burner flame is adjusted to minimum  
4) Make sure that the flame does not go out when switching quickly from the  
MAXIMUM to the MINIMUM position.  
WARNING: The above-mentioned adjustment should be made only for natural gas, while for operation with  
liquid gas the screw must be locked at the end in a clockwise direction. The grill burner always  
operates at maximum and therefore no minimum adjustment is required.  
9
 
SERVICE & MAINTENANCE INSTRUCTIONS  
Service and maintenance only to be carried out by an authorised person  
To replace parts such as burners, valves and electric components, the appliance must be open removing the worktop.  
Note: if the valves must be replaced, first disassemble the ignitions switches wires.  
It is recommended to replace the valve gaskets each time the valve is replaced, thus ensuring a perfect seal between the  
body and the gas train.  
WARNING: After first installation of the appliance or after any service intervention concerning main gas parts of  
the appliance, make the leak test using water with soap on the gas connections in order to verify the correct  
installation. Do not use fire for gas leak testing.  
USER MANUAL  
DESCRIPTIONS  
DESCRIPTIVE CAPTION FOR HOB  
1. Small Burner  
2. Medium burner  
DESCRIPTION OF HOBS  
Model CB36500X [C3W0..U7X(2 or 5)A]Fig. A  
Model CB36600X [C3Y0..U7X(2 or 5)A]Fig. B  
3. Rapid burner  
4. Dual burner  
Fig. A  
Fig. B  
CONTROL PANEL DESCRIPTION  
On the control panel, small symbols show the function of each knob or key. Here as follows are the several controls that  
a cooker can have:  
the symbol  
shows the disposition of burners on the worktop, the full dot identifies the burner in object (in  
this case the front burner on the right).  
WARNINGS:  
Keeping appliance area clear and free from combustible materials, gasoline and other flammable vapors and  
liquid.  
Do not store dangerous or flammable material in the cabinet areas above appliance; store them in a safe place  
in order to avoid potential hazards.  
For safe use of appliance, do not use it for space heating.  
Do not use aerosol sprays in the vicinity of this appliance while it is in operation  
10  
 
USING BURNERS  
A diagram is etched on the control panel above each knob which indicates which burner corresponds to that knob.  
Manual ignition:  
Manual ignition is always possible even when the power is cut off or in the event of prolonged power failure.  
Turn the knob that corresponds to the burner selected counterclockwise to the MAXIMUM position at the etched star  
(large flame) and place a lit match up to the burner.  
Automatic electric ignition:  
Turn the knob that corresponds to the burner selected anticlockwise direction to the MAXIMUM position at the etched  
star (large flame) and then press the knob down to activate the spark ignition. Once ignited, keep pressing the knob for  
about 10 seconds to allow the flame to heat the thermocouple. If the burner does not remain alight after releasing the  
knob repeat the above procedure,  
Note: It is recommended not to try to ignite the burner if the relative flame cap is not in the correct position  
Note: Dual burner is composed by two burner (inside and outside); each one operates under the relative gas valve  
indipendently from the other one.  
Tips for using burners correctly:  
WARNING: During use of each gas burner(s) adjust the burner flame size properly so it does not extend beyond  
the edge of the cooking utensil. This is an instruction based on safety considerations  
- Use suitable pots for each burner (see Fig. and Table )  
- When the liquid is boiling, turn down the knob to the MINIMUM position.  
- Always use pots with a cover.  
Correct flame aspect: verify that aspect flame of the worktop burners be completely blue and with an aspect as  
indicated in figure(flame)  
Table  
Burner  
Small  
Recommended pan diameters inches (mm)  
35½”-551/8”(90 – 140)  
Medium  
Large  
551/8”- 1023/8”(140 – 260)  
707/8”- 1023/8” (180 – 260)  
Dual burner  
862/3”-1023/8” (220 – 260)  
WARNING: check the position of the burner caps before operation.  
Correct usage of pans:  
- Dry the bottom of the pan before placing it on the hotplate.  
- Use pots with a flat, thick bottom, except for wok cooking.  
- When using the burners, ensure that the handles of the pans are correctly positioned. Keep children away from the  
appliance.  
- When cooking foods with oil and fat, which are very flammable, the user should not leave the appliance unattended.  
WOK PAN: To use the wok pan, please utilize a suitable wok adaptor grid; wok pan external diameter shall not be less  
than 10” (25cm) and not more than 16”(40cm).  
11  
 
WARNING: If the power is cut off, the burners can be lit with matches.  
The burners equipped with a safety thermocouple can only be lit when the knob is in the MAXIMUM position (large flame  
etching).  
CLEANING THE APPLIANCE:  
Never use abrasive cleaners  
Before cleaning the appliance it should be disconnected from the power supply.  
Cleaning the work surface: periodically clean the burner heads, the cast iron pan supports and the burner caps using  
warm water.  
Any spillage must always be removed as soon as possible using a rag.  
If it become difficult to open or close a valve, do not force it, but immediately request the assistance of the  
technical service personnel.  
Cleaning the enamelled parts: Enamelled parts should be cleaned frequently with soapy water. Never use abrasive  
powder. Do not leave acidi or alkaline substances on the enamelled parts (such as vinegar, lemon juice, salt, tomato  
sauce, etc.) and do not wash the enamelled parts while they are still hot.  
Cleaning the stainless steel parts: Clean the parts with soapy water and dry them with a soft cloth. The shine is  
maintained by periodically using specific stainless steel cream cleaner. Never use abrasive powders. Use specific  
stainless steel cream cleaner to eliminate the glue remains afther the elimination of the blue plastic protection film on the  
worktop after installation.  
Cleaning the burner caps: Lift the burner caps from the burner heads and wash them in soapy water and dry  
thoroughly. Before replacement on the burner head ensure that the holes are not clogged.  
ATTENTION: for further details about cleaning of the appliance, please contact your applliance retailer.  
AFTER SALE SERVICE:  
Please note here below details for after save service.  
Refer to warranty certificate for warranty condiftions  
Dealer /Importer:  
Name, address, phone  
SERVICE CENTERS  
Name  
Phone  
MANUFACTURER:  
BERTAZZONI SPA  
VIA PALAZZINA, 8 – 42016 – GUASTALLA (REGGIO E.) ITALY  
Tel. 0522/226411 – telefax 0522/226440 – http://www.bertazzoni.com  
12  
 

Blue Rhino Outdoor Fireplace WAD808WD User Manual
Bose Speaker System 34104 User Manual
Bose Speaker System Surround Sound Speaker System User Manual
Bryan Boilers Boiler LDTV 10 User Manual
Carrier Thermometer TP NRH A User Manual
Casio Cell Phone C721 User Manual
Casio Digital Camera EX Z 280 User Manual
C Crane Radio CC Radio 2 User Manual
Char Broil Charcoal Grill 463250511 User Manual
Cisco Systems Conference Phone CP9951CCAMK9 User Manual