Stand/ Dated/ Edition/ Versione/ Versiòn 06/99  
CP 343–1  
6GK7 343-1BA00-0XE0  
ab Ausgabestand 7 (FW–Stand V5.00)  
version 7 or higher (firmware V5.00)  
à partir de la version 7 (microprogramme V5.00)  
a partire dalla versione 7 (versione FW V4.00)  
a partir de la versión 7 (FW-V5.00)  
SIMATIC S7–300  
Deutsch / English / Français / Italiano / Español  
E SIEMENS AG 1998  
Änderungen vorbehalten  
Subject to alteration  
Sous réserve de modifications  
Con riserva di modifiche  
Sujeto a cambios  
english  
Contents  
Notes for the Reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
The CP 343-1 Communications Processor . . . . . . . . . . . . . . .  
1.1 Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1.2 Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1.2.1 Characteristics of S7 Communication . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1.2.2 Characteristics of ISO Transport Connections . . . . . . . . . . . . . . . . . . .  
1.3 Displays and Mode Selector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1.4 Further Information on Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2.1 Module Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2.2 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2.3 Attaching the CP 343-1 to Industrial Ethernet . . . . . . . . . . . . . . . . . . . .  
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3.1 General Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3.2 Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3.3 Notes on the CE Approval of SIMATIC NET Products . . . . . . . . . . . . .  
References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Compatibility with the Previous Version  
The version of the CP 343-1 described here is functionally compatible with and can  
be used to replace the CP 343-1 with order number 6GK7 3431BA000XE0 ver-  
sion 6.  
The CP 343-1 decribed here has more functions. Refer to the information in  
Section 1.1.  
Reply Form (at the end of this product information):  
We would like to know the purpose for which you are using this module  
and would also like to know your opinion of the module and the documen-  
tation. You can help us to provide you with better support and to further  
improve the product. We would be grateful if you would complete the reply  
form and return it to us by post or fax.  
1
Productinformation CP 3431  
C79000Z8964C03805  
 
english  
Notes for the Reader  
Safety Guidelines  
This manual contains notices which you should observe to ensure your  
own personal safety, as well as to protect the product and connected  
equipment. These notices are highlighted in the manual by a warning  
triangle and are marked as follows according to the level of danger:  
Note  
draws your attention to particularly important information on the product, handling  
the product, or to a particular part of the documentation.  
Caution  
!
!
!
indicates that minor personal injury or property damage can result if proper pre-  
cautions are not taken.  
Warning  
indicates that death, severe personal injury or substantial property damage can  
result if proper precautions are not taken.  
Danger  
indicates that death, severe personal injury or substantial property damage will  
result if proper precautions are not taken.  
Copyright E SiemensAG 1998..1999 All rights reserved  
DisclaimerofLiability  
The reproduction, transmission or use of this document or its  
contents is not permitted without express written authority.  
Offenders will be liable for damages. All rights, including rights  
createdbypatentgrantorregistrationofautilitymodelordesign,are  
reserved.  
Wehavecheckedthecontentsofthismanualforagreementwiththe  
hardware and software described. Since deviations cannot be  
precludedentirely, we cannot guarantee full agreement. However,  
the data in this manual are reviewed regularly and any necessary  
corrections included in subsequent editions. Suggestions for  
improvementare welcomed.  
Siemens AG  
A&D  
Technical data subject to change.  
IndustrialAutomationSystems  
Postfach4848, D-90327Nürnberg  
2
Productinformation CP 3431  
C79000Z8964C03805  
 
english  
1
The CP 343-1 Communications Processor  
Application  
The CP 343-1 communications processor is designed for operation in an  
S7-300 programmable logic controller. It allows the S7-300 to be attached to  
Industrial Ethernet.  
LED displays  
Mode selector  
AUI/ITP interface  
15-pin sub D  
with sliding locking  
mechanism  
Figure 1 CP 343-1  
Design  
The module has been designed to match the components of the S7-300  
programmable logic controller and has the following features:  
S Double-width module for simple installation in the S7-300 rack.  
S The operator controls and displays are all located on the front panel.  
S No fan necessary.  
S Direct backplane bus connection of the modules via accompanying  
backplane module connectors.  
S 15-pin sub D female connector with sliding locking mechanism for  
attaching the CP 343-1 to Industrial Ethernet (automatic switchover  
between the AUI interface and Twisted Pair interface).  
3
Productinformation CP 3431  
C79000Z8964C03805  
 
english  
Configuration  
You can configure the CP 3431 via MPI or LAN/Industrial Ethernet. You re-  
quire STEP 7 with the following version of NCM S7 for Industrial Ethernet  
(abbreviated to NCM IEbelow):  
Table 1  
Version STEP7/NCM IE  
Functionality of the CP 3431  
V2.x to V5.x  
The same functionality is available as with the previous  
versions of the CP.  
S Configuration data created with these STEP 7 or NCM  
versions can be downloaded to the CP 3431.  
V5.x + SP2 or higher  
The full functionality including the extended functions as  
listed in Section 1.1 can be used.  
Information about the required service pack (SP2) is  
available on the Internet at:  
1.1  
Characteristics  
Services  
The CP 343-1 supports the following communication services:  
S S5-compatible communication with  
SEND/RECEIVE interface via ISO transport connections  
FETCH/WRITE services (passive; according to the S5 protocol) via  
ISO transport connections and ISO-on-TCP connections  
S S7 communication with  
PG functions  
Operator control and monitoring functions  
Data exchange using communication function blocks  
PG functions:  
Using the PG functions, modules such as the FM 354 or FM 355 can be  
accessed via the CP (extendedPG functions).  
4
Productinformation CP 3431  
C79000Z8964C03805  
 
english  
Note  
If there is a diagnostic connection to the CP via the CPU, configuration  
data cannot be downloaded automatically to the CP by the CPU at the  
same time!  
Extended Functions Compared with Version 5  
S Reading and writing data in the FETCH/WRITE mode  
The services FETCH and WRITE are supported for direct access to sy-  
stem memory areas on the SIMATIC S7 PLC via ISO transport and and  
ISO-on-TCP connections. The SIMATIC S7-300 with the CP 343-1 is  
always the server (passive connection establishment), while the fetch or  
write access (client functionality with active connection establishment)  
originates from a SIMATIC S5 PLC or other device  
Requirements General Operation  
The following table shows the S7300 CPUs with which the CP 3431 can be  
operated with this range of functions:  
Table 2  
CPU  
MLFBNumber  
CPU 312 IFM  
6ES7 3125AC020AB0  
6ES7 3125AC820AB0  
6ES7 3131AD030AB0  
6ES7 3141AE040AB0  
6ES7 3141AE840AB0  
6ES7 3145AE030AB0  
6ES7 3145AE830AB0  
6ES7 3151AF030AB0  
6ES7 3152AF030AB0  
6ES7 3152AF830AB0  
6ES7 3162AG000AB0  
6ES7 3182AJ000AB0  
CPU 312 (T)  
CPU 313  
CPU 314  
CPU 314 (T)  
CPU 314 IFM  
CPU 314 IFM (T)  
CPU 315  
CPU 3152 DP  
CPU 3152 DP (T)  
CPU 3162 DP  
CPU 3182  
5
Productinformation CP 3431  
C79000Z8964C03805  
english  
Table 2  
CPU  
MLFBNumber  
CPU 614  
6ES7 6141AH030AB3  
6ES7 6141AH030AB3Z  
CPU 614Z  
The table lists the CPUs approved at the time of printing this product informa-  
tion bulletin. S7300 CPUs approved later and not listed in the table also  
support the range of functions described here.  
All versions of the SINUMERIK CPUs 840D and 810D are supported.  
Requirements ISO Transport Connections  
The following conditions must be taken into account on ISO transport con-  
nections depending on the length of the data to be transferred:  
Table 3  
Functionality  
Requirement  
Transfer of  
data fields <= 240 bytes  
The blocks AG_SEND FC5 and AG_RECV FC6 or as an  
alternative the blocks AG_LSEND FC50 and AG_ LRECV  
FC60 are required.  
Transfer of data  
Note the two requirments below:  
fields > 240 bytes  
S You require the blocks AG_LSEND FC50 and  
AG_LRECV FC60. These blocks are shipped with  
NCM V 4.02 with service pack 1.  
The blocks are shipped as standard components of  
newer versions of NCM.  
S Configuration:  
When configuring the CP 3431 with Hardware  
Configuration in STEP 7, select the option Data length  
> 240 bytesunder the Optionstab.  
6
Productinformation CP 3431  
C79000Z8964C03805  
english  
1.2  
Performance Data  
1.2.1  
Characteristics of S7 Communication  
The functions and characteristics of S7 communication are described in /8/  
and /11/.  
1.2.2  
Characteristics of ISO Transport Connections  
The following information is important for operating ISO transport connections  
(SEND/RECEIVE interface):  
Table 4  
Characteristic  
Explanation / Values  
Total number of connections on Industrial  
Ethernet  
32 maximum  
Number of connections for S7 communication The actual value depends on the CPU type  
on Industrial Ethernet  
being used. Please refer to /1/ for the values  
for your CPU.  
Number of ISO transport connections  
16 maximum  
Maximum data length for AG_SEND and  
AG_RECV blocks  
AG_SEND and AG_RECV allow the transfer  
of data fields of between 1 and 240 bytes.  
Maximum data length for AG_LSEND and  
AG_LRECV blocks  
AG_LSEND and AG_LRECV are shipped for  
the CP 3431 from version 5 or higher  
(firmware V3.00) and permit the transfer of  
data fields of between 1 and 8192 bytes (for  
more detailed information, see Table 3 ).  
Reaction Times of ISO Transport Connections  
The calculation of the reaction times with ISO transport connections is deter-  
mined by the run time of the function blocks required on the S7-300 CPU  
(AG-SEND, AGRECV).  
7
Productinformation CP 3431  
C79000Z8964C03805  
 
english  
Table 5  
Component  
Explanation / Values  
Run time in the CPU 314-1  
per block  
AG-SEND/AG-LSEND,  
AG-RECV/AG-LRECV  
2.5 ms to 5 ms  
1.3  
Displays and Mode Selector  
LED Displays  
The LED panel on the front of the CP 343-1 has three display elements:  
SF  
RUN  
STOP  
Figure 2 LED Displays  
CP Operating Mode  
The LEDs indicate the current operating mode of the CP 343-1 as follows:  
STOPLED  
RUNLED  
SFLED  
CP operating mode  
(yellow)  
(green)  
(red)  
start up  
RUN  
STOPPING  
STOP  
STOP with internal error  
8
Productinformation CP 3431  
C79000Z8964C03805  
 
english  
STOPLED  
(yellow)  
RUNLED  
(green)  
SFLED  
(red)  
CP operating mode  
Module fault / system error  
flashing  
Legend:  
lit  
off  
Note  
Read the explanations of the operating modes in the NCM S7 for  
Industrial Ethernet manual /8/.  
Controlling the Operating Mode  
There are three ways in which you can control the mode of the CP 343-1, as  
follows:  
S Mode selector  
S From a PG/PC. You can also control the modes using the configuration  
software in STEP 7, as follows .  
NCM S7, Diagnostics for Industrial Ethernet (see /8/);  
SIMATIC Manager\CP343-1\PLC\Operating Mode  
Mode Selector  
With the mode selector, you can set the following modes:  
S Switch from STOP to RUN:  
In the RUN mode, all communication services are available.  
The CP modes can only be controlled using NCM S7 or the SIMATIC  
Manager when the selector is set to RUN.  
S Switch from RUN to STOP:  
The CP changes to the STOP mode.  
In the STOP mode, only the configuration and diagnostic functions are  
available on the CP 343-1.  
9
Productinformation CP 3431  
C79000Z8964C03805  
english  
Note  
Read the sections about downloading configuration data to the CP in the  
NCM S7 for Industrial Ethernet manual /8/.  
1.4  
Further Information on Operation  
Downloading Firmware  
The CP 343-1 supports firmware updates using the Firmware Loader.  
An update of the firmware can be downloaded from the PC/programming de-  
vice at any time. After downloading the firmware, the CPU must be reconfigu-  
red (power off/on or memory reset).  
For more information on downloading the firmware, refer to the README file  
of the NCM S7 for Industrial Ethernet configuration software.  
Note  
Read the information on downloading a database to the CP in the  
NCM S7 manual /8/.  
Group status 8183on the FC call interface  
The return values DONE=0; ERROR=1; Status=8183 can be caused by the  
following states:  
S The CP is in the STOP mode.  
S The connection is not configured.  
S The connection is not established  
10  
Productinformation CP 3431  
C79000Z8964C03805  
 
english  
Status on the FC call interface; special situation with FC versions  
With the FCs AG_SEND (FC 5) and AG_RECV (FC 6), you receive the follo-  
wing return values after a connection is aborted:  
S AG_SEND: DONE=1; ERROR=0; Status=0000H  
S AG_RECV: DONE=0; ERROR=1; Status=8183H  
The new FCs for longer data fields (FC AG_LSEND and AG_LRECV) react in  
exactly the same way to a connection abort, in other words with the return  
values  
S DONE=0; ERROR=1; Status=8183  
Influence of MPI Connections on Connections via Industrial Ethernet  
If a station on MPI is added or removed, for example because a service PG  
has been connected or disconnected, it is possible that all the connections on  
the communications bus are aborted. This has the following effects on the  
communication connections on Industrial Ethernet:  
S All S7 connections are temporarily aborted.  
S The ISO Transport connections on which a job with a data length > 240  
bytes is being processed are aborted.  
The return values must be handled accordingly on the FC interface in the  
user program.  
2
Installation  
2.1  
ModuleAccessories  
The accessories required to attach the CP 343-1 to an Industrial Ethernet  
LAN must be ordered separately. For more detailed information, see /9/, /10/,  
/12/.  
11  
Productinformation CP 3431  
C79000Z8964C03805  
 
english  
2.2  
Procedure  
Steps in Installation  
Installing the CP 343-1 involves the following steps.  
S Plug in the CP 343-1 and secure it with the screws (make sure that the  
bus connector between the CPU/IM and CP 343-1 is present).  
S Attach the CP 343-1 to Industrial Ethernet as illustrated in Section 2.3.  
S Connect a 24 V power supply.  
Note  
Make sure that you use the same voltage source as for the CPU or  
IM 361.  
Note  
The two front panels must be kept closed during operation. The module  
must be installed so that its upper and lower ventilation slits are not  
covered, allowing adequate ventilation.  
Configuration  
To initialize the CP 343-1 for communication services, use the configuration  
tool NCM S7 for Industrial Ethernet.  
PG/PC Connection  
You can connect the programming device when configuring the CP as  
follows:  
S via MPI  
S via Industrial Ethernet  
If you configure the module via Industrial Ethernet, the CP 343-1 must  
already have a MAC address, in other words the hardware configura-  
tion of the CP 343-1 must already have been downloaded via the MPI  
interface (for details of node initialization, see /8/).  
12  
Productinformation CP 3431  
C79000Z8964C03805  
 
english  
2.3  
Attaching the CP 343-1 to Industrial Ethernet  
The CP 343-1 can be attached to Industrial Ethernet using a  
S Transceiver with an AUI interface  
CP 3431  
SF  
RUN  
STOP  
RUN  
STOP  
Transceiver  
cable  
R
(dropcable) 727-1  
Transceiver  
Figure 3 Attaching the CP 343-1 to Industrial Ethernet with AUI/Transceiver  
The CP 343-1 generates and supplies the 13 V power required by the  
transceiver.  
S Industrial Twisted Pair attachment, for example using a Optical Switch  
Module (OSM) or hub.  
When using the Industrial Ethernet installation cable shown in Figure 4,  
the CP 343-1 automatically switches over to Twisted Pair. Information  
about the pinout can be found at the end of this section.  
With Industrial Twisted Pair, cables with a length of up 100 m can be  
installed between the CP and Optical Switch Module (OSM).  
13  
Productinformation CP 3431  
C79000Z8964C03805  
 
english  
CP 3431  
CP 3431  
SF  
SF  
e.g Optical Switch Modul  
(OSM)  
RUN  
RUN  
STOP  
STOP  
RUN  
STOP  
RUN  
STOP  
R
R
ITP installation  
cable  
Figure 4 Attaching the CP343-1 to Industrial Ethernet with TP/Optical Switch Module (OSM) or Hub  
S Optical Industrial Ethernet using an AUI attachment  
Connection of the CP 343-1 TCP to Industrial Ethernet is also possible  
using an optical transceiver with an AUI interface.  
Optical  
module  
CP 3431  
SF  
RUN  
STOP  
Star  
RUN  
STOP  
coupler  
R
727-1  
Fiber optic cable  
Connectingcable  
Figure 5 Attaching the CP 343-1 to Industrial Ethernet with AUI/ Optical Transceiver  
14  
Productinformation CP 3431  
C79000Z8964C03805  
english  
3
Technical Data  
3.1  
General Technical Data  
Dimensions and Weight  
Dimensions, module in casing H x W x D (mm)  
Weight  
125x80x120  
approx. 750 g  
Voltage, Current, Operating Conditions  
Power supply  
5 V DC +/5%  
24 V DC +/5%  
Current consumption:  
from the S7-300 backplane bus:  
from the external 24 V supply:  
70 mA  
0.6 A.  
Permitted ambient temperature  
Specifications according to /7/ must be  
adhered to when operating an S7-300 tier  
horizontal installation  
vertical installation  
0 to 60° C  
0 to 40° C  
Altitude  
up to 3000m above sea level  
All the information in /7/ in the Section General Technical Dataregarding the  
following topics also applies to the CP 343-1:  
S Electromagnetic compatibility  
S Transportation and storage conditions  
S Mechanical and climatic ambient conditions  
S Insulation tests, class of protection and degree of protection  
15  
Product information CP 3431  
C79000Z8964C03805  
 
english  
3.2  
Pinout  
Connector for Industrial Ethernet  
On the front panel of the CP 343-1, there is a 15-pin sub D female connector  
with a sliding locking mechanism for connecting a transceiver cable. The  
signals of an ITP interface can also be applied to this connector (switchover  
by relay).  
For operation via the AUI interface, use the 727-1 transceiver cable. A  
special SIMATIC NET ITP cable must be used when operating via the ITP  
interface.  
PinNo  
Signalname  
Function  
External ground, shield  
Collision +  
1
2
3
MEXT  
CLSN  
TRMT / TPETXD  
Transmit + / TPE transmit  
data +  
4
Ground  
Ground 5V  
CP 3431  
5
RCV / TPERXD  
Receive + / TPE Receive  
data +  
SF  
6
7
M 15 V  
Ground 15 V  
AUI/ITP switchover  
Ground 5 V  
RUN  
TPE_SEL  
Ground  
STOP  
RUN  
STOP  
8
9
CLSN_N  
Collision –  
10  
TRMT_N /  
Transmit / TPE Transmit  
TPETXD_N  
data –  
R
11  
Ground  
Ground 5V  
12  
RCV_N /  
Receive / TPE Receive  
TPERXD_N  
data –  
13  
14  
15  
P15 V  
Ground  
+15 V  
Ground 5V  
Figure 6 ConnectorPinoutDiagram  
Notes on the Pinout  
The pinout complies with the IEEE 802.3 AUI interface.The signals TPETXD /  
TPETXD_N and TPERXD / TPERXD_N implement the ITP interface.  
16  
Productinformation CP 3431  
C79000Z8964C03805  
 
english  
3.3  
Notes on the CE Approval of SIMATIC NET Products  
Product name:  
CP 343-1  
Order number: 6GK7 343-1BA00-0XE0  
EU Directive EMC89/336/EEC  
The SIMATIC NET products listed above meet the requirements of the EU  
directive 89/336/EEC Electromagnetic Compatibility.  
The EU conformity certificates are available for the relevant authorities accor-  
ding to the EU directives and are kept at the following address:  
Siemens Aktiengesellschaft, Bereich A&D  
Industrielle Kommunikation  
SIMATIC NET (A&D PT 2)  
Postfach 4848  
D90327 Nürnberg  
Germany  
Area of Application  
The product is designed for use in an industrial environment.  
Requirements  
Area of application  
Industrial  
Noise emission  
EN 50081-2 : 1993  
Noise immunity  
EN 50082-2 : 1995  
Directive on Machines  
The product remains a component in compliance with Article 4(2) of the EU  
directive on machines 89/392/EEC.  
According to the directive on machines, we are obliged to point out that this  
product is intended solely for installation in a machine. Before the final pro-  
duct is started up, it must be established that it conforms to the directive  
89/392EEC.  
Installation Guidelines  
The product meets the requirements providing you adhere to the guidelines  
for installation and operation in the following documentation /7/, /9/ and /12/.  
17  
Productinformation CP 3431  
C79000Z8964C03805  
 
english  
4
References  
The following documentation is necessary for configuration and operation  
and contains detailed information:  
/7/  
/8/  
For installing and starting up the CP 343-1  
Manual: S7-300 Programmable Controller, Hardware and Installation  
For using and configuring the CP 343-1  
Manual: SIMATIC NET NCM for S7 Industrial Ethernet  
/9/  
SIMATIC NET Manual: Triaxial Networks for Industrial Ethernet  
Ethernet Manual (HIR)  
/10/  
/11/  
Users Guide to STEP 7  
Part of the basic STEP 7 package.  
/12/  
SIMATIC NET Manual: ITP Networks for Industrial Ethernet  
Order Numbers  
The order numbers for the SIEMENS documentation listed above can be  
found in the catalogs SIMATIC NET Industrial Communication, Catalog IK  
10and SIMATIC Programmable Logic Controllers SIMATIC S7 / M7 / C7.  
These catalogs and additional information about the products and training  
courses can be obtained from your local SIEMENS office.  
-
18  
Productinformation CP 3431  
C79000Z8964C03805  
 
From  
C79000-Z8974-C43-01  
Mail / FAX Reply (Call ++911-978-3321)  
Name  
.............................................................................  
.............................................................................  
.............................................................................  
.............................................................................  
.............................................................................  
.............................................................................  
.............................................................................  
Position  
Company  
Address  
Town  
To  
Siemens AG, Infoservice  
A&D Z 032  
Postfach 2348  
D-90713 Fürth  
Germany  
Postcode  
Country  
Dear customer,  
You can order a sticker to mark the actual version  
level of your CP`s with this letter or by fax.  
! Please send me the sticker  
---  
Our Industrial Ethernet application:...................................................................................................................  
Type of application  
Which S7-300 CPU  
are you using ?  
!
!
CPU 312 IFM  
CPU 315  
!
!
CPU 313  
!
CPU 314 / 314 IFM  
CPU 315-2  
andere :............  
How many CP 343-1 modules are  
you using ?  
No. of CP 343-1:  
.............. No. of CP 443-1:  
..............  
No. of S5 CPs: ..............  
Which and how many  
Send/Receive: ! SIMATIC S5............... ! SIMATIC S7................  
communication partners are you  
using in your system?  
! PC with CP 1413.......... ! PC with SOFTNET........  
! WS.............................  
S7-Functions: ! SIMATIC S7............... ! PC with CP 1413...........  
! PC with SOFTNET....... ! WS..............................  
Number of connections ?  
SEND/RECV : ...........................  
SEND/RECV :............................  
S7-Functions: .............................  
S7-Functions:..............................  
Average data length in bytes per  
connection ?  
---  
Type of cabling  
!
!
Electrical with ITP  
!
!
Optical with OLM  
other:  
...............................................  
Electrical with  
Triax (Yellow  
Cable)  
Optical with star  
couplers  
Network topology  
!
Bus  
!
Redund. ring  
!
Star  
other : ................  
Suggestions:...........................................................................................................................................................  
................................................................................................................................................................................  
Note: Your information will be used to improve our products and will of course be handled confidentially.  
Suggestions for improvement are welcome on e-mail address [email protected]. Please include for  
identification “CP 343-1”.  

Yorkville Sound Car Speaker YS1098 User Manual
Toshiba HDD2136 User Manual
Toshiba Full Color Led Display System TR 2010E User Manual
Sony WM EC1 User Manual
Sony VCT HM1 User Manual
Sony TRV78 User Manual
Sony ISSUE 3 User Manual
Sony Handycam HDR CX700VE User Manual
Sony CCD TR3400 User Manual
Sanyo LNS S02Z User Manual