Wolf Ventilation Hood PL582212 User Manual

Planning Information  
Pro Ventilation Hood Liner  
M O D E L P L 5 8 2 2 1 2  
Seamed  
construction  
Stainless steel  
enclosed liner  
Stainless steel  
baffle filters  
Model PL582212  
Location of  
rating plate  
Welded seams  
and hemmed edges  
Recessed easy-  
access controls  
Halogen lighting  
Infinite-speed  
blower control  
Wolf Pro hood liners allow you to incorporate  
superior ventilation within your kitchen design.  
Whether you prefer French country or modernist, Pro  
hood liners take care of the interior design, with true  
superior ventilation. All you have to do is decide what  
it will look like.  
Wolf Model PL582212 Pro hood liner  
will accommodate a 60" (1524) wide  
decorative hood. Pro hood liners are sold  
as a shell only; internal, in-line and remote  
blower options are available.  
Sometimes referred to as power packs, these liners  
bring all of the controls, lighting and convenience of  
our Pro ventilation line for those applications with a  
custom exterior treatment.  
Pro ventilation hood liners are recommended for use  
with all Wolf cooking appliances. Model PL582212 will  
accommodate a 60" (1524) wide decorative hood.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
1
7/07  
 
Planning Information  
Pro Ventilation Hood Liner  
M O D E L P L 5 8 2 2 1 2  
B L O W E R O P T I O N S  
S P E C I F I C A T I O N S  
Overall Width of Liner  
Overall Height of Liner  
Overall Depth of Liner  
Internal Blower Option  
In-Line Blower Option  
Remote Blower Options  
Discharge  
1200 CFM Internal Blower  
1100 CFM In-Line Blower  
900 CFM Remote Blower  
1200 CFM Remote Blower  
1500 CFM Remote Blower  
805087  
583/8" (1483)  
12" (305)  
808332  
801641  
801642  
804701  
221/2" (572)  
1200 CFM  
1100 CFM  
900, 1200 or 1500 CFM  
Vertical  
Refer to Pro Ventilation Recommendations  
at the end of this section.  
Duct Size  
10" (254) Round  
A C C E S S O R I E S  
Electrical Supply Requirements  
110/120 V AC, 60 Hz  
15 amp dedicated circuit  
38" (965) high classic stainless  
steel backsplash with or without  
warming racks  
Shipping Weight (shell only)  
82 lbs (37 kg)  
Specifications are subject to change without notice.  
Accessories are available through your  
Wolf dealer. To obtain local dealer  
information, visit the Showroom Locator  
section of our website, wolfappliance.com.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
3
 
Planning Information  
Pro Ventilation Hood Liner  
M O D E L P L 5 8 2 2 1 2  
I N S T A L L A T I O N S P E C I F I C A T I O N S  
LOCATION OF  
ELECTRICAL  
6"  
(152)  
E
5"  
(127)  
DECORATIVE HOOD  
HOOD LINER  
DECORATIVE HOOD  
HOOD LINER  
12" (305)  
HEIGHT OF LINER  
3
58 /8" (1483)  
WIDTH OF LINER  
1
30" TO 36"  
(762–914)  
TO COUNTERTOP  
22 /2" (572)  
DEPTH OF LINER  
30" TO 36"  
(762–914)  
TO COUNTERTOP  
D I M E N S I O N S  
Overall Width of Liner  
Overall Height of Liner  
Overall Depth of Liner  
583/8" (1483)  
12" (305)  
221/2" (572)  
30" (762) to 36" (914)  
Within shaded area  
Countertop to Bottom of Decorative Hood  
Location of Electrical  
See Installation Instructions shipped with unit for detailed specifications.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
4
 
Planning Information  
Pro Ventilation Hood Liner  
M O D E L P L 5 8 2 2 1 2  
I N S T A L L A T I O N N O T E S  
Refer to the illustrations and specifications  
for overall dimensions and installation specifics.  
You must follow all National Electrical Code  
regulations. In addition, be aware of local codes  
and ordinances when installing your service.  
Wolf Pro ventilation hood liners are recom-  
mended for use with any Wolf cooking appli-  
ance, and should be as least as wide as the  
cooking surface. It is recommended that the  
hood overlap the cooking surface by 3" (76) on  
either side.  
A decorative hood can be created out of  
wood, plaster, tile or metal. The shape of the  
decorative hood is not critical. The only place  
where the liner and outside cover must meet is  
at the bottom edge of the metal liner. The deco-  
rative hood and liner must fit at the bottom  
edge in both width and depth.  
Installation of all Pro hood liners should be  
30" (762) to 36" (914) from the bottom of the  
decorative hood to the countertop. Follow the  
dimensions shown in the Installation  
illustration on page 4.  
The height of the liner does not have to be  
the same as the height of the decorative hood  
and is generally shorter.  
Wolf Pro hood liners are shipped without a  
blower assembly. Internal, in-line or remote  
blower assemblies are available. Blower options  
also vary with the volume of air that needs to  
be moved and the length of the duct run. Refer  
to the charts at the end of this section for Pro  
ventilation recommendations and blower  
options.  
The top depth of the liner, which is 12" (305)  
standard, must be less than the interior depth  
of the decorative hood. Measure the interior  
depth of the hood at the top height of the liner  
to make sure the liner will fit inside the decora-  
tive hood.  
The hood liner comes standard with a 4"  
(102) lower reveal. Be sure to include this  
dimension in your decorative hood selection.  
IMPORTANT NOTE: Install this ventilation hood  
liner only with a Wolf blower.  
Always use the interior measurements of the  
decorative hood and measure in multiple places.  
Use the smallest dimensions to verify hood liner  
specifications.  
Pro hood liners require a separate, grounded  
110/120 V AC, 60 Hz power supply. The service  
should have its own 15 amp circuit breaker.  
Placement of the electrical supply is not critical,  
as long as you provide enough 120 V AC, 60 Hz  
power cable to make the electrical connection.  
Locate electrical within the shaded area shown  
in the Installation illustration on page 4.  
Refer to the installation instructions shipped  
with each Wolf product for detailed specifica-  
tions. This information can also be found on  
our website, wolfappliance.com.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
5
 
Planning Information  
Pro Ventilation Hood Liner  
M O D E L P L 5 8 2 2 1 2  
D U C T I N G C O N S I D E R A T I O N S  
Wolf Pro hood liners are shipped without the  
blower assembly. Internal, in-line and remote  
blower assemblies are available.  
Local building codes may require the use of  
make-up air. Consult your local HVAC profes-  
sional for specific requirements in your area.  
IMPORTANT NOTE: Install this ventilation hood  
liner only with a Wolf blower.  
IMPORTANT NOTE: Wolf Pro hood liners must  
be vented to the outside. Use only metal  
ductwork.  
Pro hood liners have a vertical discharge location  
with 10" (254) round duct. A transition with  
backdraft damper is included. The hood liner will  
operate most efficiently when ductwork does  
not exceed 50' (15 m) in length.  
Refer to the illustration below for ducting  
considerations for Pro ventilation hood liners.  
Ducting for Pro ventilation  
hood liners.  
DUCTWORK INSTALLATION  
THROUGH ROOF  
ROOF CAP OR REMOTE BLOWER  
10" ROUND DUCT  
TRANSITION  
221/4"W x 9"D  
TO 10" ROUND 10"H  
SOFFIT OR CABINET  
OR DUCT COVER  
DIMENSIONS INCLUDE FLANGES  
DECORATIVE HOOD  
VERTICAL DISCHARGE  
HOOD LINER  
12" (305)  
HEIGHT OF LINER  
1
22 /2" (572)  
DEPTH OF LINER  
30" TO 36"  
(762–914)  
COUNTERTOP  
TO BOTTOM OF  
DECORATIVE HOOD  
36" (914)  
STANDARD  
FLOOR TO  
COUNTERTOP  
HEIGHT  
VERTICAL DISCHARGE ONLY FOR VENTILATION HOOD LINERS.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
6
 
Planning Information  
Pro Ventilation Hood Liner  
M O D E L P L 5 8 2 2 1 2  
W O L F B L O W E R A S S E M B L I E S  
A ventilation system must include a blower  
assembly. Wolf ventilation hood liners are  
shipped without the blower assembly. An  
internal, in-line or remote blower assembly must  
be selected to accommodate the cooking appli-  
ance, CFM requirements and homeowner prefer-  
ences. Internal, in-line and remote blower assem-  
blies are available as sales accessories through  
your Wolf dealer.  
Internal blowers are mounted inside the hood  
liner canopy. In-line blowers are mounted in  
between the hood liner and the exterior of the  
home. Remote blowers can be mounted on the  
roof or in some cases, on an exterior wall. Refer  
to the illustrations below for dimensions of Wolf  
in-line and remote blowers.  
Pro ventilation recommendation charts on the  
following page provide minimum CFM recom-  
mendations according to the cooking appliance  
and hood liner used and blower options for each  
specific Pro hood liner.  
IMPORTANT NOTE: Use only a Wolf blower  
with all Wolf ventilation products.  
7
24 /8"  
(632)  
18"  
(457)  
12"  
(305)  
8"  
(203)  
22"  
(559)  
18"  
(457)  
In-line BLOWER-110IL  
21" (533)  
18" (457)  
3
20 /4"  
(527)  
10"  
(254)  
10"  
(254)  
1
1
28 /4"  
(718)  
1
29 /2"  
(749)  
29 /2"  
(749)  
10" (254)  
10" (254)  
Diameter  
10" (254)  
Diameter  
Diameter  
1
15 /2"  
(394)  
3
3
14 /4"  
(375)  
14 /4"  
(375)  
1
1
1
29 /2"  
(749)  
29 /2"  
(749)  
24 /2"  
(622)  
3
1
14"  
(356)  
10 /8"  
(264)  
10 /8"  
(257)  
3
/4"  
(121)  
4
3
24 /4"  
(629)  
1
7
(184)  
1
25"  
(635)  
22"  
(559)  
7
/4"  
/4"  
(184)  
Remote BLOWER-90REM  
Remote BLOWER-120REM  
Remote BLOWER-150REM  
Unit dimensions may vary by 1/8" (3).  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
7
 
Planning Information  
Pro Ventilation Hood Liner  
M O D E L P L 5 8 2 2 1 2  
P R O V E N T I L A T I O N C F M R E C O M M E N D AT I O N S  
Pro Hood Liners  
Model  
PL342212  
600  
PL402212  
600  
PL462212  
PL522212  
PL582212  
DF304 / R304 / SRT304  
DF366 / R366 / SRT366 / RT366  
DF364 / R364 / SRT364 / RT364  
RT362  
900  
900  
900  
900  
900  
900  
R488 / RT488  
1100  
1100  
900  
1100  
1100  
900  
DF486 / R486 / SRT486 / RT486  
DF484 / R484 / SRT484 / RT484  
DF606 / R606  
1500  
1500  
DF604  
Minimum CFM requirements for Wolf ranges and rangetops. CFM recommendations are based on total Btu/hr output.  
Additional CFM may be required for charbroilers, griddles and long duct runs.  
P R O V E N T I L A T I O N B L O W E R O P T I O N S  
Pro Hood Liners  
Blower Description  
1200 CFM Internal  
1100 CFM In-Line  
900 CFM Remote  
1200 CFM Remote  
1500 CFM Remote  
Blower Number  
Hood Liner Models  
All Hood Liners  
All Hood Liners  
All Hood Liners  
All Hood Liners  
All Hood Liners  
LBLOWER-120INT (805087)  
BLOWER-110IL (808332)  
BLOWER-90REM (801641)  
BLOWER-120REM (801642)  
BLOWER-150REM (804701)  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
8
 

Whirlpool Ventilation Hood 99044504A User Manual
Whirlpool Ventilation Hood RH2624XJQ3 User Manual
Wibur Curtis Company Water Dispenser F 3366 User Manual
Windsor Carpet Cleaner PSP I User Manual
Yamaha Musical Instrument BST1 User Manual
Zanussi Range 178002 User Manual
Zanussi Range ZCM 5600 User Manual
Zanussi Refrigerator ZB1420T User Manual
Zanussi Refrigerator ZTR 57 R User Manual
Zephyr Ventilation Hood ZVO E30AG User Manual