1F80-24
Programmable Electronic Digital Thermostat
WHITE-RODGERS
INSTALLATION AND
OPERATION INSTRUCTIONS
Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
Your new White-Rodgers Digital Thermostat uses the technol-
ogy of a solid-state microcomputer to provide precise time/
temperature control. This thermostat offers you the flexibility to
design heating and cooling programs that fit your needs.
• LCD continuously displays set point, and alternately dis-
plays time and room temperature
• Temperature override until next program period
• Manual program override (HOLD temperature)
• User may select either 12- or 24-hour clock display
• °F/°C convertibility
Features:
• Battery powered (3 “AA” Energizer® alkaline batteries in-
cluded)
• Temperature range 45° to 90°F
• Same program for all days of the week
• Standard five terminals for single or dual transformer
systems
• B & O terminals for single stage heat pumps or damper
operation
• Simultaneous heat and cool program storage
• Four separate time/temperature settings per program
• Preprogrammed temperature control
PRECAUTIONS
Thisthermostatisintendedforusewithalowvoltagesystem;do
not use this thermostat with a line voltage system. If in doubt
about whether your wiring is millivolt, line, or low voltage, have
itinspectedbyaqualifiedheatingandairconditioningcontractor
or electrician.
CAUTION
!
To prevent electrical shock and/or equipment dam-
age, disconnect electric power to system at main fuse
or circuit breaker box until installation is complete.
Do not exceed the specification ratings.
WARNING
!
Allwiringmustconformtolocalandnationalelectricalcodesand
ordinances.
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
This control is a precision instrument, and should be handled
carefully. Roughhandlingordistortingcomponentscouldcause
the control to malfunction.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
SPECIFICATIONS
ELECTRICAL DATA
APPLICATIONS
Electrical Rating:
For use with:
8 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.5 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)
• Standard heat/cool or heat only systems
• Electric heat systems
• Gas or oil fired systems
• Gas systems with intermittent ignition devices (I.I.D.) and/
or vent dampers
• Hydronic (hot water or steam) systems
• Single-stage heat pump systems
• Millivolt systems
THERMAL DATA
Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range:
32°F to 105°F
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-40°F to 150°F
DO NOT USE WITH:
• Multi-stage systems
• Systems exceeding 30 VAC and 1.5 amps
• 3-wire zoned hydronic heating systems
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
PART NO. 37-5287E
Printed in U.S.A.
Replaces 37-5287D
9901
ST. LOUIS, MISSOURI 63123-5398
JUMPER
WIRE
THERMOSTAT
SYSTEM
Y
B
O
G
W
RC
RH
THERMOSTAT
SYSTEM
Y
B
O
G
W
RC RH
Heating
System
Cooling
System
Fan
Relay
Heating
System
24 VAC Transformer
NOTE
or
Hot
RED jumper wire (provided
with thermostat) must be
connected between thermo-
stat's RH and RC terminals
for proper thermostat oper-
ation with this system.
Thermopile
24 VAC
120 VAC
Neutral
Figure 3. Typical wiring diagram for heating only,
2-wire, single transformer systems or millivolt systems
TRANSFORMER
Figure 7. Typical wiring diagram for
heat/cool, 4-wire, single transformer systems
THERMOSTAT
Thermostat
NOTE
Y
B
O
G
W
RC
RH
3-wire Series 10
Primary Control
(located at furnace)
Jumper wire must be
added between R and B
terminals on the primary
control (jumper wire not
provided with thermostat).
SYSTEM
Hot
Cooling
System Relay System
Fan
Heating
R
W
24 VAC
120 VAC
Neutral
B
HEATING TRANSFORMER
W
Hot
R
24 VAC
120 VAC
Neutral
Furnace
Add jumper wire
(not provided with thermostat)
COOLING TRANSFORMER
Figure 4. Typical wiring diagram for
3-wire SERIES 10 heating systems
Figure 8. Typical wiring diagram for
heat/cool, 5-wire, two-transformer systems
JUMPER
WIRE
JUMPER
WIRE
JUMPER
WIRE
THERMOSTAT
SYSTEM
THERMOSTAT
SYSTEM
Y
B
O
G
W
RC
RH
Y
B
O
G
W
RC RH
NOTE
Reversing Compressor Fan
Valve*
Contactor Relay
Fan
Relay
Heating
System
RED jumper wire (provided
with thermostat) must be
connected between thermo-
stat's RH and RC terminals
for proper thermostat oper-
ation with this system.
Hot
Hot
24 VAC
120 VAC
Neutral
24 VAC
120 VAC
Neutral
* Reversing valve is energized when the
system switch is in the COOL position
TRANSFORMER
TRANSFORMER
Figure 9. Typical wiring diagram for
Figure 5. Typical wiring diagram for
heat only, 3-wire, single transformer systems
heat pump with cool active reversing valve
JUMPER
WIRE
JUMPER
WIRE
THERMOSTAT
SYSTEM
THERMOSTAT
Y
B
O
G
W
RC RH
Y
B
O
G
W
RC
RH
SYSTEM
Reversing Compressor Fan
Valve*
Contactor Relay
Cooling
System
Fan
Relay
Hot
Hot
24 VAC
120 VAC
Neutral
24 VAC
120 VAC
* Reversing valve is energized when the
system switch is in the HEAT position
Neutral
TRANSFORMER
TRANSFORMER
Figure 10. Typical wiring diagram for
heat pump with heat active reversing valve
Figure 6. Typical wiring diagram for
cool only, 3-wire, single transformer systems
3. Move FAN switch to AUTO position. The blower should stop
CHECK THERMOSTAT OPERATION
immediately.
If at any time during testing your system does not operate
properly, contact a qualified serviceperson.
Heating System
1. Move SYSTEM switch to HEAT position. If the heating
Fan Operation
system has a standing pilot, be sure to light it.
If your system does not have a G terminal connection, skip to
Heating System.
2. Press
to adjust thermostat setting above room tempera-
ture. The heating system should begin to operate.
1. Turn on power to the system.
2. Move FAN switch to ON position. The blower should begin
3. Press
toadjusttemperaturesettingbelowroomtempera-
to operate.
ture. The heating system should stop operating.
3
1. Move SYSTEM switch to COOL position.
2. Press to adjust thermostat setting below room tempera-
ture.Theblowershouldcomeonimmediatelyonhighspeed,
Cooling System
This thermostat has a built-in short-term (5-minute) time delay.
This feature is activated after the compressor shuts down and
the setpoint is changed within the 5-minute period. During this
5-minute period, COOL will flash on the display indicating that
followed by cold air circulation
the thermostat has locked out the compressor to allow head 3. Press
pressure to stabilize. This thermostat does not sense AC power
loss and therefore does not activate the short term compressor
protection feature when power is restored.
to adjust temperature setting above room tem-
perature. The cooling system should stop operating.
CAUTION
!
Topreventcompressorand/orpropertydamage, ifthe
outdoor temperature is below 50°F, DO NOT operate
the cooling system.
OPERATION
Before you begin programming your thermostat, you should be
familiarwithitsfeaturesandwiththedisplayandthelocationand
operation of the thermostat buttons. Your thermostat consists of
two parts: the thermostat cover and the base. To remove the
cover, gently pull it straight out from the base. To replace the
cover, line up the cover with the base and press gently until the
cover snaps onto the base.
1
2
THE THERMOSTAT BASE
SET TIME VIEW PRGM RUN PRGM HOLD TEMP
FAN ON
AUTO
COOL OFF HEAT
Other than
and
, the following buttons and switches are
located behind the door on the bottom of the thermostat cover
(see fig. 11). Pull the door down to open it.
The Thermostat Buttons and Switches
3
4
5
6
7
8
(Red arrow) Raises temperature setting.
(Blue arrow) Lowers temperature setting.
SET TIME button.
1
2
3
4
5
6
7
8
9
HEAT
AM
10
COOL
BATTERY
HOLD
VIEW PRGM (program) button.
RUN PRGM (program) button.
HOLD TEMPerature button.
11
12
10 13
9
Figure 11. Thermostat display, buttons, and switches
FAN switch (ON, AUTO).
Alternately displays current time and temperature.
10
11
SYSTEM switch (COOL, OFF, HEAT).
BATTERY is displayed when the 3 “AA” batteries are low
and should be replaced. Nothing else will be displayed.
The Display
Displays currently programmed set temperature (this is
12
13
HEAT is displayed when the SYSTEM switch is in the
9
blank when SYSTEM switch is in the OFF position).
HEATposition. COOL isdisplayed(non-flashing)whenthe
SYSTEM switch is in the COOL position. COOL is dis-
played (flashing) when the compressor is in lockout mode.
The word HOLD is displayed when the thermostat is in the
HOLD mode.
4
• TEMPERATURE DISPLAY ADJUSTMENT — Your new
thermostathasbeenaccuratelysetinourfactory.However,
if you wish, you may adjust your new thermostat tempera-
ture display to match your old thermostat. This can be
accomplished (within a ±4° range) as follows:
OPERATING FEATURES
Now that you are familiar with the thermostat buttons and
display, read the following information to learn about the many
features of the thermostat.
• SIMULTANEOUS HEATING/COOLING PROGRAM
STORAGE—Whenprogramming,youcanenterbothyour
heating and cooling programs at the same time. There is no
need to reprogram the thermostat at the beginning of each
season.
1. Press VIEW PRGM and HOLD TEMP buttons at the
same time.
2. Press
or
to adjust the displayed temperature to
your desired setting.
3. PressRUNPRGMtoresumenormalprogramoperation.
• TEMPERATURE OVERRIDE — Press
or
until the
display shows the temperature you want. The thermostat
will override current programming and keep the room
temperature at the selected temperature until the next
program period begins. Then the thermostat will automati-
cally revert to the program.
• HOLD TEMPERATURE — The thermostat can hold any
temperaturewithinitsrangeforanindefiniteperiod, without
reverting to the programmed temperature. Press HOLD
TEMP button. HOLD will be displayed. Then choose the
PROGRAMMING YOUR THERMOSTAT
Now you are ready to program your thermostat. This section will
help you plan your thermostat’s program to meet your needs.
For maximum comfort and efficiency, keep the following guide-
lines in mind when planning your program.
• When heating (cooling) your building, program the tem-
peratures to be cooler (warmer) when the building is vacant
or during periods of low activity.
• During early morning hours, the need for cooling is usually
minimal.
desired hold temperature by pressing
or
. The
thermostat will hold the room temperature at the selected
setting until you press RUN PRGM button to start program
operation again.
• Programthethermostattoallowabout 30minutestoreach
the desired temperature. (For example, if the first person
gets up at 6:00 AM, program the first period to begin at
5:30 AM.)
• °F/°C CONVERTIBILITY — Press SET TIME and HOLD
TEMP buttons until the temperature display is in Celsius
(°C). To display Fahrenheit (°F), repeat the process.
Look at the factory preprogrammed times and temperatures
shown below. If this program will suit your needs, simply press the
RUN PRGM button to begin running the factory preset program.
• 12-HOUR/24-HOUR CLOCK DISPLAY — The clock is set
to display 12-hour time, which means that the clock will
display AM and PM time (12:00 AM is midnight; 12:00 PM is
noon). However, you may want to display a 24-hour clock
(military-style time). The 24-hour clock display will show 1:00
PM as 13:00, 2:00 PM as 14:00, and so on. To change to the
24-hour clock display, press SET TIME and RUN PRGM
buttons at the same time. In the 24-hour clock mode, AM and
PM are not displayed.
FACTORY PREPROGRAMMING
Cooling Program for
ALL Days of the Week:
Heating Program for
ALL days of the Week:
TEMP
PERIOD
TIME
TEMP
PERIOD
1st
2nd
3rd
4th
TIME
68°F
68°F
68°F
64°F
1st
2nd
3rd
4th
6:00 AM
8:00 AM
5:00 PM
10:00 PM
6:00 AM
8:00 AM
5:00 PM
10:00 PM
78°F
82°F
78°F
78°F
If you want to change the preprogrammed times and tempera-
tures, follow these steps.
• LOW BATTERY INDICATOR — If the 3 “AA” alkaline
batteries are low and should be replaced, the display will be
blank except for the word BATTERY. When the batteries are
low, pressing any button will cause the display to operate for
ten seconds. After ten seconds, the display will be blank
exceptforthewordBATTERY. Youcannotprogramwithlow
batteries, but you can override setpoint temperature.
Determine the time periods and heating and cooling tempera-
tures for your heating and cooling programs. You must program
four periods for both the heating and cooling programs. How-
ever, you may use the same heating and cooling temperatures
for consecutive time periods. Use the table at the bottom of the
page to plan your program time periods, and the temperatures
you want during each period. You may also want to look at the
sample program table to get an idea of how the thermostat can
be programmed.
SAMPLE
Heating/Cooling Schedule Plan
Heating/Cooling Schedule Plan
COOL PROGRAM
COOL PROGRAM
HEAT PROGRAM
HEAT PROGRAM
Start
Start
Start
Start
Period
Time
Temperature
Time
Temperature
Period
Time
Temperature
Time
Temperature
1ST
1ST
5:30 AM
68°F
6:30 AM
76°F
2ND
3RD
4TH
2ND
3RD
4TH
8:00 AM
5:00 PM
10:30 PM
65°F
70°F
65°F
2:00 PM
5:00 PM
10:30 PM
78°F
72°F
78°F
5
Enter Cooling Program
Entering Your Program
Follow these steps to enter the heating and cooling programs
you have selected.
CAUTION
!
If the outside temperature is below 50°F, disconnect
power to the cooling system before programming.
Energizing the air conditioner compressor during
cold weather may cause personal injury or property
damage.
Set Current Time and Day
1. Press SET TIME button once. The display will show the hour
only.
1. Move SYSTEM switch to COOL position.
PM
EXAMPLE:
2. Follow the procedure for entering your heating program,
using your selected cooling times and temperatures.
2. Press and hold either
or
until you reach the correct
CHECK YOUR PROGRAMMING
hour and AM/PM designation (AM begins at midnight; PM
begins at noon).
Follow these steps to check your thermostat programming one
final time before beginning thermostat operation.
3. Press SET TIME once. The display window will show the
minutes only.
1. Move SYSTEM switch to HEAT position.
2. Press VIEW PRGM to view the 1st heating period time and
temperature. Each time you press VIEW PRGM, the next
heating period time and temperature will be displayed in
sequence (you may change any time or temperature during
this procedure).
EXAMPLE:
4. Press and hold either
minutes.
or
until you reach the correct
3. Press RUN PRGM.
4. Move SYSTEM switch to COOL position.
5. Repeat step 2 to check cooling temperatures.
6. Press RUN PRGM to begin program operation.
5. Press RUN PRGM once. The display will show the correct
time and room temperature alternately.
Enter Heating Program
YOUR THERMOSTAT IS NOW COMPLETELY PRO-
GRAMMED AND READY TO AUTOMATICALLY PROVIDE
MAXIMUM COMFORT AND EFFICIENCY!
1. If you want to change the display from Fahrenheit to Celsius
(or vice-versa), press SET TIME and HOLD TEMP at the
same time.
2. Move the SYSTEM switch to HEAT.
3. Press VIEW PRGM once. The currently programmed start
time for the 1st heating period and the currently pro-
grammed temperature will be displayed (flashing).
MO TU WE TH FR
AM
EXAMPLE:
This display window shows that for the 1st heating period,
the start time is 6:00 AM, and 68° is the programmed
temperature(thisexamplereflectsfactorypreprogramming).
4. Press
or
tochangethedisplayedtemperaturetoyour
selected temperature for the 1st heating program period.
5. Press SET TIME once (the programmed time will flash).
Press
or
until your selected time appears. The time
will change in 15 minute increments. Press SET TIME a
second time to return to the change temperature mode.
6. Press VIEW PRGM once. The currently programmed start
time and setpoint temperature for the 2nd heating program
period will appear.
7. Repeat steps 4 and 5 to select the start time and heating
temperature for the 2nd heating program period.
8. Repeatsteps4through6forthe3rdand4thheatingprogram
periods. The heating programs are now complete.
9. When you have completed entering your heating program,
press RUN PRGM.
|