F92-1011
Regulated L.P. to Natural Gas
Conversion Kit for 36G/36J Two-Stage
INSTALLATION INSTRUCTIONS
Installer: Save these instructions for future use!
FAILURETOREADANDFOLLOWALLINSTRUCTIONSCAREFULLYBEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
WARNING
TO CONVERT FROM L.P. TO NATURAL GAS
!
This conversion kit shall be installed by a qualified
service agency in accordance with the manufacturer’s
instructionsandallapplicablecodesandrequirements
oftheauthorityhavingjurisdiction.Iftheinformationin
1. Remove both regulator cover screws.
2. Remove both regulator adjustment screws (beneath the
cover screws).
these instructions is not followed exactly, a fire, explo-
sion, or production of carbon monoxide may result,
causing property damage, personal injury, or loss of
life. The qualified service agency performing the work
assumes the responsibility for the proper conversion
of this appliance with this kit.
3. Remove both regulator springs from regulator sleeves. (L.P.
configuration may be two L.P. springs, color-coded white, or
one L.P., color-coded white, and one Natural, color-coded
silver/plain).
4. Insert the Natural Gas regulator springs (provided in the
conversion kit and color-coded silver/plain) into the regulator
sleeves.
5. Replace the High regulator adjustment screw and adjust
approximately 14 turns from top of sleeve.
APPLICATION
This conversion kit allows the 36G Series and 36J Series Two-
Stage gas valves to be used on Natural gas applications. This
conversion kit is for use on all 36G/36J Two-Stage, fast and
slow open models.
6. Replace the Low regulator adjustment screw and adjust
approximately 10 turns from top of sleeve.
7. Adjust both outlet pressures to the appliance manufacturer's
requirements.
8. Replace both regulator cover screws.
High
Low
9. Remove the L.P. WARNING label, if
present, fromthegasvalve. Alsoattachthe
small round NAT GAS labels to the top of
the regulator cover screws.
!
WARNING
VALVE CONVERTED FOR USE ON L.P.
GAS. IMPROPER OPERATION COULD
RESULT IN DEATH OR SERIOUS
INJURY.
Regulator
Cover Screw
!
MISE EN GARDE
SOUPAPE CONVERTIE POUR USAGE
SUR GAZ DE PÉTROLE LIQUÉFIÉ.
UN FONCTIONNEMENT INAPPROPRIÉ
PEUT PROVOQUER LA MORT OU DES
BLESSURES GRAVES.
Plastic Regulator
Adjustment Screw
WARNING Label
Regulator Spring
Natural Gas Regulator
Springs (silver/plain)
NAT.
GAS
NAT.
GAS
Natural Gas Labels
Figure 2. Contents of kit
Figure 1. 36G/36J 2-Stage models
PARTNO.37-6586B
Replaces 37-6586A
1005
White-Rodgers is a division
of Emerson Electric Co.
|