ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm.
• When opening the sliding carriage for the first time after installing the hood, pull it out briskly until it
clicks.
USE
Control panel
L
M - V
M-V
L
L Light
Switches the lighting system on
and off
L Light
Switches the lighting system on
and off
M Motor Switches the extractor motor on
M Motor Switches the extractor motor on
and off
and off
V Speed Sets the operating speed of the ex-
tractor:
V Speed Sets the operating speed of the ex-
tractor:
1. Low speed, used for a contin-
uous and silent air change in
the presence of light cooking
vapour.
I. Low speed, used for a contin-
uous and silent air change in
the presence of light cooking
vapour.
2. Medium speed, suitable for
most operating conditions
given the optimum treated air
flow/noise level ratio.
II. Maximum speed, used for
eliminating the highest cook-
ing vapour emission, includ-
ing long periods
3. Maximum speed, used for
eliminating the highest cook-
ing vapour emission, includ-
ing long periods
GB
7
MAINTENANCE
Grease filters
CLEANING METAL SELF-SUPPORTING GREASE FILTERS
The filters must be cleaned every 2 months of oper-
ation, or more frequently with heavy usage, and can
be washed in a dishwasher.
• Remove the filters one at a time, after
disconnecting the relative fastening elements.
• Wash the filters, taking care not to bend them.
Allow them to dry before refitting.
• When refitting the filters, make sure that the
handle is visible on the outside.
CLEANING MULTILAYER METAL GREASE FILTERS
The filters must be cleaned every 2 months of oper-
ation, or more frequently with heavy usage, and can
be washed in a dishwasher.
• Release the filter retaining grill using the lateral
sliding handles.
• Remove the filter retaining clips.
• Remove and wash the filters. Allow them to dry
before refitting.
• Replace the filters on the grill, fix them in
position using the filter retaining clips and close
the filter retaining grill.
REPLACING SYNTHETIC GREASE FILTER
The filter is not washable and cannot be regenerat-
ed, and must be replaced every 2 months of use, or
more frequently with heavy usage.
• Release the filter holder frame using the lateral
sliding handles.
• Remove the fIlter retaining clips.
• Replace the saturated synthetic filter.
• Fix the new synthetic filter using the retaining
clips and close the filter holder frame.
GB
8
Odour filters (Recirculation version)
REPLACING ACTIVATED CHARCOAL FILTERS
These filters are not washable and cannot be regen-
erated, and must be replaced every 4 months of op-
eration, or more frequently with heavy usage.
• Remove the grease filters.
• Remove the saturated activated charcoal filters as
shown (A).
B
• Fit new filters (B).
• Replace the grease filters.
A
GB
9
This appliance conforms to European Low Voltage Directive 73/23/CEE governing electrical safety, European Directive 89/336/