Digital Pocket thermometer With
StainleSS Steel Probe
NOTE Please keep this manual handy as you use your new product. It contains practical step-by-step instructions, as well as technical specifications and warnings you should know about. Do not use a dishwasher to clean the
probe or immerse in water or liquid. Clean the probe with water and a mild detergent. Wipe the cabinet with a damp cloth.
FEATURES
TEMPERATURE MEASUREMENT
USING THE AUTO POWER OFF AND POWER OFF FUNCTIONS
1. Pull out the Pocket Thermometer from the plastic sleeve.
Press the [AUTO-OFF] button. This enables “AUTO” to display, indicating
the thermometer will turn off automatically. If you do not press any key for
6 to 7 minutes, the thermometer will turn off automatically.
Easy operation:
Displays the temperature reading automatically.
2. Pierce the sensor probe into meat or place the sensor probe into water.
Press and hold the [ON/FAST] button for a faster sensing rate, the
measuring temperature will show on the display in a second. The
temperature sensing rate will operate at its normal speed if you do not
press the [ON/FAST] button.
Error-free Reading: Digital display system ensures clear, error-free
reading at a glance.
If you press the [AUTO-OFF] button once again, the thermometer will turn
off immediately.
Wide Range:
User Friendly:
Measuring range from -50°C to 260°C
(-58°F to 500°F)
Caution: The effective measuring area is 1.5"–2" from the tip.
User selectable normal or fast sampling cycle.
Plastic sleeve for sensor probe protection.
SPECIFICATIONS
Do not expose the main unit out of the operating temperature.
Caution: Do not leave the thermometer in the food on the grill.
Operation temperature
:
:
0°C - 50°C (32°F - 122°F)
TEMPERATURE DISPLAY
AUTO - OFF
Temperature measuring range (probe)
-50°C to 260°C
(-58°F - 500°F)
USING THE MAXIMUM AND MINIMUM
TEMPERATURE MEMORY
Temperature display resolution
:
Min 0.1°C to Max 0.5°C
(Min 0.2°F to Max 1°F)
STAINLESS STEEL PROBE
1.5"–2"
Temperature sampling cycle
(Normal)
The Pocket Thermometer will automatically record the maximum and minimum
measurements.
You can recall those readings by doing the following:
:
:
:
:
:
:
10 seconds
MAX/MIN
(Fast)
2 seconds
EFFECTIVE
MEASURING AREA
Power Source
Battery life
One (1) LR-44 battery
Approximate 6 Months
Diameter 2.8 mm ∞ 110 mm
30g (with plastic sleeve)
FUNCTION
CURRENT ACTION
DISPLAY
NEXT
DISPLAY
ON/FAST
BATTERY COVER
Metal probe size
Weight
Recall the
Maximum
temperature
ꢀ
22.3
Press [MAX/MIN] once
s 28.8
Recall the
Minimum
s 28.8
Press [MAX/MIN] once
again
t18.8
temperature
Return to current t18.8
temperature
Press [MAX/MIN] once
again
22.3
METAL CLIP
PLASTIC SLEEVE
WARRANTY
RESETTING THE MAXIMUM OR MINIMUM
TEMPERATURE MEMORIES
Weber-Stephen Products Co., (Weber®) hereby warrants to the ORIGINAL
PURCHASER of this Digital Pocket Thermometer, that it will be free
from defects in material and workmanship from the date of purchase as
follows: 2 year(s) when assembled, and operated in accordance with the
printed instructions accompanying it.
INSTALLING AND REPLACING BATTERIES
The unit uses 1 LR-44 size battery which is included in the package.
Follow these steps to install or replace battery:
The Pocket Thermometer will automatically record the maximum and minimum
measurements.
You can reset those readings by doing the following:
Weber may require reasonable proof of your date of purchase.
THEREFORE, YOU SHOULD RETAIN YOUR SALES RECEIPT
OR INVOICE.
1. Use a screw driver to open the battery cover. (Follow the direction of
the arrow.)
FUNCTION
CURRENT ACTION
DISPLAY
NEXT
DISPLAY
2. Insert a new battery (make sure positive (+) is facing you).
This Limited Warranty shall be limited to the repair or replacement of
parts that prove defective under normal use and service and which on
examination shall indicate, to Weber’s satisfaction, that they are defective.
If Weber confirms the defect and approves the claim, Weber will elect to
repair or replace such parts without charge. If you are required to return
defective parts, transportation charges must be prepaid. Weber will return
parts to the purchaser, freight or postage prepaid.
Reset the
Maximum
temperature
memory
s 28.8
Press and hold
s 22.3
3. Replace the battery cover.
(With the
Maximum
temperature
display)
[ON/FAST] button for 1
second.
(The current
temperature
will become
the maximum
memory)
DISPLAY MODES
The thermometer has three different display modes:
Reset the
Minimum
temperature
memory
t18.8
Press and hold
[ON/FAST] button for 1
second.
t22.3
(With the
Minimum
temperature
display)
(The current
temperature
will become
the minimum
memory)
This Limited Warranty does not cover any failures or operating difficulties
due to accident, abuse, misuse, alteration, misapplication, vandalism,
improper installation or improper maintenance or service, or failure to
perform normal and routine maintenance. Deterioration or damage due
to severe weather conditions such as hail, hurricanes, earthquakes or
tornadoes, discolouration due to exposure to chemicals either directly or
in the atmosphere, is not covered by this Limited Warranty. Weber shall not
be liable under this or any implied warranty for incidental or consequential
damages. This warranty gives you specific legal rights, and you may also
have other rights, which vary from state to state.
DISPLAY MODE
FUNCTION
DISPLAY
22.3
Normal
Shows the current measuring
temperature.
Return to current t22.3
temperature
Press [MAX/MIN] once
22.3
Maximum Temperature
Memory
Shows the maximum temperature
recorded since last memory reset.
s 28.8
t18.8
Minimum Temperature
Memory
Shows the minimum temperature
recorded since last memory reset.
NOTE: You may like to clear the memory occasionally, so you can record
the Maximum / Minimum for a specified period.
Auto Power OFF
The thermometer will
AUTO 22.3
Weber Customer Service (US only) 1-800-446-1071.
Resetting a memory will result in the current temperature being
displayed in the Maximum or Minimum memory display.
automatically turn off, if you do not
press any key for 6 to 7 minutes.
178722 8/07
|