Wayne Dalton Garage Door Opener Wireless Wall Station User Manual |
Operating the W ireless W all Station
I
Up-Dow n Button:
Backlit LED Light:
Momentarily pressing the Up/Down button starts or stops door
The red LED blinks intermittently to help you locate the wall station in a
movement or changes door s direction. Pressing and holding Up/
dark garage. This blink rate can be changed for longer battery life or can
Down button during the door s travel will override safety sensors. The be turned off. The default blink rate is one blink every 3 seconds. For
Up/Down Button (when unit is closed) can be activated by pressing
flip cover.
longer battery life the blink rate can be changed to blink once every 6
seconds. To change the blink rate, remove the battery cover and remove
one battery. Re-install the battery and within 2 seconds, press the Light
button. Re-install the battery cover.
W ARNING
IF DOOR REQUIRES THAT SAFETY SENSORS BE OVERRIDDEN
THAT CONDITION MUST BE CORRECTED IMMEDIATELY. FAILURE
TO MAKE ADJUSTMENTS/REPAIRS COULD RESULT IN SEVERE
OR FATAL INJURY.
For longest battery life, the blink can be turned off. To turn off the blink,
remove the battery cover and remove one battery.
Re-install the battery and within 2 seconds, press the Pet button. Re-
install the battery cover.
Light Button:
Momentarily pressing the light button turns on the convenience light. NOTE: The wall station s red LED will blink rapidly while any wall station
The light will remain on until either the light button is pressed again
or the door is activated. The light automatically turns on with a door
activation and remains on for 4 minutes. Pressing the light button
before the 4 minutes has elapsed will turn off the light. W hile the
door is in motion, the light button functions identically as the Up/
Down button, stopping or reversing the door immediately.
button remains pressed.
Pet Position:
Pressing the pet button opens a closed door to a preset position between
5 and 30 inches above the floor, allowing pets to enter and exit the
garage without the door being fully open. The door must be fully closed
to activate the pet open feature. Pressing the pet button with a stationary
door in the pet open position will cause the door to close. Pressing the
Up/Down button while the door is in the pet position will cause the door
to open. W hile the door is in motion, the pet button functions identically
to the Up/Down button, stopping or reversing the door immediately. The
pet feature allows for custom setting of the pet position door height.
Tim er Button:
Momentarily pressing the timer button causes a delayed activation of
a stationary fully open door. The light fixture or the opener s lamp will
blink on and off for about 10 seconds prior to closing the door,
allowing enough time to exit the garage when the opener is in the
timer mode. Pressing any button, except the program button while
the opener lamp is blinking cancels the timer mode.
NOTE: A door in the “pet position” (open 5-30 inches) is not locked and
should not be used as a secured door position.
NOTE: The timer feature will only function with the door in the full
open position. Pressing the timer button with a stationary door in any
other position will cause the opener lamp to blink 4 times and the
door will not be activated.
Program Button:
The wall station program button has several functions.
a. It can be used to set a custom pet position. (see Customizing the
Settings, on the next page)
W hile the door is in motion, the timer button functions identical to
the Up/Down button, stopping or reversing the door immediately.
b. It can be used to set the opener s closing force (see Adjustment
#1 Page 32).
Vacation Slide Sw itch:
The slide switch has two positions: Normal, and Door lock.
Normal position:
Move the slide switch to normal position for all normal functions of
the opener. The normal position will cancel the door lock feature.
NOTE: W hen the slide switch is moved to the unlocked position the
opener light fixture will blink on/off three times.
Up/Down Button
Light Button
Door Lock position:
If the door is stopped (fully open, fully closed or partially open) move
the slide switch to the door lock position to suspend all normal
functions of the opener. The opener will remain completely disabled
and non-operational in this mode. All wall stations, transmitters and
keyless entry units are ignored until the slide switch is moved to the
normal position. If the door is moving when the slide switch is
moved to the door lock position, the door lock mode is not activated
and all functions of the opener remain active.
Vacation
Slide Switch
Timer Button
Program Button
NOTE: W hen the slide switch is moved to the locked position the
opener light fixture will blink on/off three times.
Pet Button
28
Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need
You can reach us Toll Free at 1-888-827-3667 for Consum er Assistance or online at w w w .w ayne-dalton.com
|