Operating the W ireless W all Station  
I
Up-Dow n Button:  
Backlit LED Light:  
Momentarily pressing the Up/Down button starts or stops door  
The red LED blinks intermittently to help you locate the wall station in a  
movement or changes door s direction. Pressing and holding Up/  
dark garage. This blink rate can be changed for longer battery life or can  
Down button during the door s travel will override safety sensors. The be turned off. The default blink rate is one blink every 3 seconds. For  
Up/Down Button (when unit is closed) can be activated by pressing  
flip cover.  
longer battery life the blink rate can be changed to blink once every 6  
seconds. To change the blink rate, remove the battery cover and remove  
one battery. Re-install the battery and within 2 seconds, press the Light  
button. Re-install the battery cover.  
W ARNING  
IF DOOR REQUIRES THAT SAFETY SENSORS BE OVERRIDDEN  
THAT CONDITION MUST BE CORRECTED IMMEDIATELY. FAILURE  
TO MAKE ADJUSTMENTS/REPAIRS COULD RESULT IN SEVERE  
OR FATAL INJURY.  
For longest battery life, the blink can be turned off. To turn off the blink,  
remove the battery cover and remove one battery.  
Re-install the battery and within 2 seconds, press the Pet button. Re-  
install the battery cover.  
Light Button:  
Momentarily pressing the light button turns on the convenience light. NOTE: The wall station s red LED will blink rapidly while any wall station  
The light will remain on until either the light button is pressed again  
or the door is activated. The light automatically turns on with a door  
activation and remains on for 4 minutes. Pressing the light button  
before the 4 minutes has elapsed will turn off the light. W hile the  
door is in motion, the light button functions identically as the Up/  
Down button, stopping or reversing the door immediately.  
button remains pressed.  
Pet Position:  
Pressing the pet button opens a closed door to a preset position between  
5 and 30 inches above the floor, allowing pets to enter and exit the  
garage without the door being fully open. The door must be fully closed  
to activate the pet open feature. Pressing the pet button with a stationary  
door in the pet open position will cause the door to close. Pressing the  
Up/Down button while the door is in the pet position will cause the door  
to open. W hile the door is in motion, the pet button functions identically  
to the Up/Down button, stopping or reversing the door immediately. The  
pet feature allows for custom setting of the pet position door height.  
Tim er Button:  
Momentarily pressing the timer button causes a delayed activation of  
a stationary fully open door. The light fixture or the opener s lamp will  
blink on and off for about 10 seconds prior to closing the door,  
allowing enough time to exit the garage when the opener is in the  
timer mode. Pressing any button, except the program button while  
the opener lamp is blinking cancels the timer mode.  
NOTE: A door in the “pet position” (open 5-30 inches) is not locked and  
should not be used as a secured door position.  
NOTE: The timer feature will only function with the door in the full  
open position. Pressing the timer button with a stationary door in any  
other position will cause the opener lamp to blink 4 times and the  
door will not be activated.  
Program Button:  
The wall station program button has several functions.  
a. It can be used to set a custom pet position. (see Customizing the  
Settings, on the next page)  
W hile the door is in motion, the timer button functions identical to  
the Up/Down button, stopping or reversing the door immediately.  
b. It can be used to set the opener s closing force (see Adjustment  
#1 Page 32).  
Vacation Slide Sw itch:  
The slide switch has two positions: Normal, and Door lock.  
Normal position:  
Move the slide switch to normal position for all normal functions of  
the opener. The normal position will cancel the door lock feature.  
NOTE: W hen the slide switch is moved to the unlocked position the  
opener light fixture will blink on/off three times.  
Up/Down Button  
Light Button  
Door Lock position:  
If the door is stopped (fully open, fully closed or partially open) move  
the slide switch to the door lock position to suspend all normal  
functions of the opener. The opener will remain completely disabled  
and non-operational in this mode. All wall stations, transmitters and  
keyless entry units are ignored until the slide switch is moved to the  
normal position. If the door is moving when the slide switch is  
moved to the door lock position, the door lock mode is not activated  
and all functions of the opener remain active.  
Vacation  
Slide Switch  
Timer Button  
Program Button  
NOTE: W hen the slide switch is moved to the locked position the  
opener light fixture will blink on/off three times.  
Pet Button  
28  
Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need  
You can reach us Toll Free at 1-888-827-3667 for Consum er Assistance or online at w w w .w ayne-dalton.com  
 

TeleAdapt Switch TA 6500 User Manual
Texas Instruments Stereo Amplifier TAS5508 5142K7EVM User Manual
Toshiba Cash Register MA 600 User Manual
Toshiba CRT Television 13A23 User Manual
TP Link Network Card T4UH User Manual
TRENDnet Router 300Mbps Wireless N Gigabit Router User Manual
Tricity Bendix Cooktop CSIE 506 X User Manual
Tricity Bendix Freezer TB 110 FF User Manual
Uniden Cordless Telephone TRU9380 3 User Manual
ViewSonic Computer Monitor VX1932wm User Manual