Vector Power Supply VEC016 User Manual

VEC016  
START-IT® COMPACT  
JUMP-START SYSTEM  
AND 12 VOLT POWER SUPPLY  
PORTABLE • CORDLESS • RECHARGEABLE  
OWNER’S MANUAL  
& WARRANTY INFORMATION  
THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY,  
OPERATION, MAINTENANCE AND STORAGE OF THIS PRODUCT. BEFORE USING,  
READ AND UNDERSTAND ALL CAUTIONS, WARNINGS, INSTRUCTIONS AND  
PRODUCT LABELS, PLUS YOUR VEHICLE’S BATTERY MANUFACTURER GUIDELINES.  
FAILURE TO DO SO COULD RESULT IN INJURY AND/OR PROPERTY DAMAGE.  
4140 SW 28TH WAY, FT. LAUDERDALE, FL 33312  
TEL 954-584-4446 • TOLL FREE: 866-584-5504 • FAX 954-584-5556  
www.vectormfg.com  
 
IMPORTANT:  
Although this unit is delivered in a partially-charged state - you must fully charge it with  
the supplied 110/120 Volt AC charger for a full 24 hours before using it for the first time.  
You can not overcharge the unit using the AC charger method.  
CAUTIONS:  
Caution statements advise against certain conditions and practices that may result in  
damage to vehicles, appliances and/or The START-IT Compact Jump-start System.  
1) Use only the supplied cords/adapters for recharging this unit. Do not recharge for more  
than 3-4 hours maximum using 12 Volt DC method. Recharge unit after each use.  
2) All On/Off switches should be in the OFF position when the unit is charging or not in use.  
Make sure all switches are in the OFF position before connection to a power source or  
load.  
3) Never insert anything other than the supplied power/recharging cords or recommended  
appliance power/recharging cords into the 12 Volt DC charging/power socket on this  
unit. Do not use any accessory that is not recommended or provided by the manufacturer.  
4) Do not use this unit to operate appliances that draw more than 15 amps.  
5) This system is designed to be used only on vehicles with 12 Volt DC battery systems. Do not  
connect to a 6 Volt or 24 Volt battery system.  
6) This system is not designed to be used as a replacement for a vehicular battery. Do not  
attempt to operate a vehicle that does not have a battery installed.  
7) Vehicles that have on-board computerized systems may be damaged if vehicle battery is  
jump-started. Before jump-starting, read the vehicles owners manual to confirm that  
external-starting assistance is advised.  
8) Excessive engine cranking can damage a vehicles starter motor. If the engine fails to start  
after the recommended number of attempts. Discontinue jumpstart procedures and look  
for other problems that may need to be corrected.  
9) Although this unit contains a non-spillable battery, it is recommended that unit be kept  
upright during storage, use and recharging. To avoid possible damage that may shorten  
the units working life, protect it from direct sunlight, direct heat and/or moisture.  
10) Check unit periodically for wear and tear. Replace worn or defective parts immediately  
contact Vector customer service department at (954) 584-4446 or toll-free  
(954) 584-5504.  
11) Do not attempt to jump-start a frozen battery.  
12) Never submerge this unit in water.  
13) All wires, cables and cords must be positioned so that they can not be tripped over or  
damaged by moving parts, by pinching or abraiding.  
 
3
CONTENTS  
1. INTRODUCTION ............................................................ 5  
1.1 ADDITIONAL KEY FEATURES .................................................... 6  
1.2 USES OF START–IT COMPACT................................................... 7  
2. USE AS JUMP-START SYSTEM........................................ 7  
2.1 JUMP-START WARNINGS .......................................................... 7  
2.2 FIRST AID................................................................................. 7  
2.3 JUMP-START PROCEDURE......................................................... 8  
3. USE AS A 12 VOLT DC PORTABLE POWER SUPPLY .......... 9  
4. CHARGING/RECHARGING............................................ 9  
4.1 AC RECHARGE ........................................................................ 9  
4.2 DC RECHARGE ...................................................................... 10  
5. MAINTENANCE - REPLACEMENT PARTS ........................ 10  
5.1 LAMP REPLACEMENT .............................................................. 10  
6. BATTERY DISPOSAL .......................................................11  
7. SPECIFICATIONS ...........................................................11  
8. WARRANTY.............................................................. 11,12  
 
4
1.  
INTRODUCTION  
Congratulations on selecting the Vector® Model VEC016 Compact Jump Starter and DC Power  
System. It can jumpstart most vehicles or boats with a standard 12 volt DC electrical system:  
boat, small truck, car, airplane, RV, personal watercraft, snowmobile, tractor, etc. Note that this  
jump starter is extra safe compared to others because it has a Safety Power Switch and a self-  
contained Audible Polarity alarm that sounds when the cable clamps are connected to incorrect  
polarity.  
This advanced design is perfect for work during emergencies and it can also enhance your fun  
by powering DC appliances to 15 amperes on the road, at the beach and at camp. Be sure to  
read and understand all WARNINGS and CAUTIONS before using this product. Please read  
this guide carefully before use to ensure optimum performance and avoid damage to the sys-  
tem or items that you are using it with.  
The built-in work/area light is invaluable when it becomes necessary to locate battery terminals  
while preparing to jump-start a dead battery in the dark.  
It is also ideal for use with Vector(tm) 12 volt DC cordless, portable, rechargeable appliances  
with ratings up to 15 amperes. For information about Vector appliances, contact Vector  
Manufacturing at 866-584-5504 (toll free) for the location of the nearest retailer.  
The unit has an easy-to-read, series of LEDs (Light Emitting Diodes) arranged as a Charge  
Status Display that shows the level of charge in the battery (from Low to Full). The Charge Status  
Display activates whenever the Charge Status Pushbutton is pressed or automatically during AC  
recharge operations. One 12-volt DC cigarette lighter-type (accessory) socket is provided for  
use with appliances that can operate from a cigarette lighter type accessory socket. The DC  
accessory socket allows for DC recharge from a vehicle or other 12 volt source. Note that the  
exposed electrical socket and recharge port has a cover that help keep out dirt, dist and  
moisture. All covers must be open for socket or port use and closed after use.  
POWER SAFETY SWITCH  
FIGURE 1  
DC RECHARGE/  
RECHARGE PORT  
ACCESSORY SOCKET  
WORKLIGHT  
WORKLIGHT  
BATTERY  
STATUS DISPLAY  
BATTERY STATUS  
PUSHBUTTON  
O
N/OFF  
SWITCH  
POS CABLE AND  
CLAMP (RED)  
NEG CABLE AND  
CLAMP (BLACK)  
The Safety Power Switch is located on the upper right side of the unit. When the Safety Switch  
it is in the OFF position, The cable clamps are not powered and the audible polarity alarm is  
ready to sound if the clamps are connected to incorrect polarity.  
Below the Safety Power Switch is the AC Recharge port. It is covered by a rubber cap that keeps  
dust, dirt, and moisture out of the socket. The AC Recharge Adapters barrel connector plugs  
into this port during recharge.  
 
5
Moving to the left of the AC recharge port are three LEDs, called the Battery Status Display, and  
a Battery Status Pushbutton. Pressing the pushbutton turns on the Battery Status Display. The  
pushbutton is pressed to check the battery level at any time. During AC recharge, the display is  
automatically active. During DC recharge, the display pushbutton can be periodically pressed  
to monitor the recharge process.  
The colors of the three Battery Status Display LEDs are two red and one green. During AC  
recharge, the Battery Status Display is active to indicate the level of charge on the battery. The  
leftmost red LED indicates minimum charge on the battery. Recharge the battery when a single  
LED is the only one that lights. The center LED (red) indicates moderate charge on the battery.  
The green LED on the right indicates when the battery is FULL and you can stop charging.  
To the left of the Battery Status Pushbutton is a work light. This provides the user with light while  
changing a tire, and connecting battery clamps. The work light is a long lasting lamp and will  
continuously operate for 32 hours from a fully charged battery. To the left of the Work light is  
the ON/Off rocker switch that controls operation of the work light.  
Above the work light switch is a 12 Volt Accessory Socket. It is covered with a rubber protective  
cap. The cap keeps dust, dirt and moisture out of the socket. When the cap is lifted, the  
accessory socket can be used for powering 12 volt appliances that draw up to 15 amps current.  
This socket is also used during DC recharge.  
1.1  
ADDITIONAL KEY FEATURES  
1. ON/OFF safety power switch (no key required, no key to get lost!).  
2. Audible Polarity alarm that sounds when cable clamps are connected to  
incorrect polarity.  
3. Cordless/rechargeable-includes recharge adapters for standard 110-volt AC wall  
socket, and vehicles 12-volt DC accessory outlet using adapter cables.  
4. Powerful-225 CCA cranking amps - 400 Amp rated clamps  
5. Includes non-spillable, maintenance-free, heavy duty, 9-ampere hour sealed  
lead-acid battery.  
6. Requires no maintenance (other than recharging) for optimum operation.  
7. Heavy duty, industrial grade copper clamps and #6AWG jumper cables-with  
exclusive recessed cable holsters.  
8. Exclusive cable storage channels that keep jumper cables out of the way until  
they are needed.  
9. 110-volt AC charger is Underwriter Laboratories safety tested and listed.  
10.Easy-to-read LED Battery Charge Status Display - activated by pressing the  
Charge Status Button and automatically activated during AC recharge.  
1.2  
USES OF START-IT COMPACT  
- Jumpstart (using heavy duty battery cable and clamps):  
Most batteries of engines with a standard 12 volt DC battery system: boat, small truck, car,  
airplane, RV, personal watercraft, snowmobile, tractor, etc.  
- Operate (using 15 ampere rated 12 Volt Accessory Socket): 12-volt DC Fans, fluorescent  
work lights, air compressors, spotlights, TVs, portable radios, cassette or CD players, and  
more. The unit can quick-charge a cellular phone by using the phones 12-volt DC  
adapter cord.  
- Illuminate areas: under the hood, inside tents, work areas while changing tires, etc.  
NOTE: Other Vector appliances may also be used with this jump starter as long as they do not  
exceed the 15 ampere limit of the jump starters cigarette lighter type socket.  
 
6
READ INSTRUCTION MANUAL AND PRODUCT LABELING CAREFULLY, BEFORE USING THIS  
PRODUCT. FOLLOW RECOMMENDED WARNINGS, CAUTIONS, AND SAFETY PROCEDURES,  
AND MANUFACTURER’S GUIDELINES FOR YOUR VEHICLE BATTERY.  
IMPORTANT  
This unit is delivered in a partially charged state - you must fully charge it before using it for the  
first time. Initial AC Charge should be for 24 hours.  
Refer to Sections 4.1 and 4.2 for use of AC Recharge Adapter and DC/DC Charging Adapter.  
2.  
USE AS A JUMP-START SYSTEM  
2.1  
JUMPSTART WARNINGS  
1. There is risk of explosive gas being released when batteries are improperly charged or  
discharged. Failure to follow instructions may Cause property damage, explosion hazard,  
and/or personal injury.  
2. Do not smoke while jump starting  
3. Only attempt to jumpstart a vehicle or boat in a well ventilated area.  
4. This power system is to be used ONLY on vehicles or boats with 12-volt DC battery systems.  
5. Do not attempt to jumpstart a frozen battery.  
6. Do not wear vinyl clothing when jumpstarting a vehicle — friction can cause dangerous  
static electricity sparks.  
7. Remove all metal jewelry - this can cause short circuits. Always use protective eyewear  
when jump-starting: contact with battery acid may cause blindness and/or severe burns.  
8. Never touch red and black clamps together - this can cause dangerous sparks, power  
arcing, and/or explosion.  
9. Do not attempt to jumpstart a frozen battery  
10.After use as jump starter, turn OFF Power Safety Switch. Keep out of reach of children.  
11.Vehicles that have on-board computerized systems may be damaged if vehicle battery is  
jump-started. Before jump-starting this type of vehicle, read the vehicles owners manual to  
confirm that external-starting assistance is advised.  
12.Always start jump-starting with Power Safety Switch turned OFF - this allows the polarity  
alarm to sound if reverse (incorrect) polarity connection is made.  
WARNING: Reverse Polarity Alarm Sounds, Reverse the cable clamp connections.  
13.Excessive engine cranking can damage the vehicle ‘s starter motor. If the engine fails to start  
after the recommended number of attempts, discontinue jump-start procedure and look for  
other problems that may need to be corrected.  
14.If vehicle to be started has a Positive Grounded System (positive battery terminal is  
connected to chassis): Replace steps 9 and 10 of the jump-start procedure (below) with the  
following steps A and B, and then proceed to step 11.  
A. Connect negative (-) black clamp to vehicle battery ‘s negative terminal.  
B. Connect positive (+) red clamp to vehicle chassis or a solid, non-moving, metal vehicle  
component or body part. DO NOT clamp directly to positive battery terminal or moving part.  
15.Replace worn or defective parts immediately - contact Vector Customer Service  
Department at (954)584-4446 or toll free at 866-584-5044.  
2.2  
FIRST AID:  
SKIN: if battery acid comes in contact with skin, rinse Immediately with water, then wash  
thoroughly with soap and water. If Redness, pain, or irritation occurs, seek immediate  
medical attention.  
EYES: if battery acid comes in contact with eyes, flush eyes Immediately-for minimum of 15  
minutes-seek immediate medical attention.  
 
7
2.3  
JUMP-START PROCEDURE  
FIGURE 2  
CABLE CLAMP  
HOLSTERS  
CABLE CLAMP  
1. Turn Off ignition and all accessories (radio, a/c, lights, cellphone, etc). If vehicle, place  
transmission in “park” and set the emergency brake.  
2. Make sure the units Power Safety Switch is turned OFF.  
3. Observe jump-starting negative or positive ground system, as follows:  
Negative ground (negative battery Terminal connected to chassis) - most common.  
4. Carefully lift negative (black) jumper cable wire from storage channel starting at clamp end  
of cable.  
5. Squeeze negative (black) clamp handle and remove clamp from holster.  
6. Carefully lift positive (red) jumper cable wire from storage channel starting at clamp end of  
cable.  
7. Squeeze positive (red) clamp handle and remove clamp from holster.  
8. Connect positive (+) red clamp to vehicles positive battery terminal.  
9. Connect negative (-) black clamp to chassis or a solid, non-moving, metal vehicle component  
or chassis part - never clamp directly to negative battery terminal or moving part.  
WARNING: If reverse polarity alarm sounds, DO NOT TURN ON SAFETY SWITCH.  
Change (swap) positions of Red and Black clamps. When proper polarity connection is  
made, the alarm will not sound - continue with next step.  
10. Turn ON units Power Safety Switch  
11. Start vehicle (crank engine in 5 - 6 second bursts) If engine won’t start, seek help and go  
to step 14.  
12. After vehicle starts turn units Power Safety Switch to OFF position.  
13. Leave engine running.  
14. Turn OFF Safety Power Switch  
15. Remove clamps. First, disconnect the clamp connected to the engine or chassis, followed  
by the clamp connected to the battery..  
16. Carefully press negative (black) jumper cable wire into storage channel starting at end  
away from the clamp.  
17. Squeeze negative (black) clamp handles and slide clamp into holster.  
18. Carefully press positive (red) jumper cable wire into storage channel starting at end away  
from the clamp.  
19. Squeeze positive (red) clamp handles and slide clamp into holster.  
20. Recharge Start-It Compact as soon as possible  
 
8
3.  
USE AS A 12-VOLT DC PORTABLE POWER SUPPLY  
WARNING: NEVER INSERT A CIGARETTE LIGHTER INTO ACCESSORY SOCKET  
NOTE: Make sure that the Units Power Safety Switch is ALWAYS in the Off position when  
using the units 12 volt DC cigarette-lighter type accessory outlet.  
1. Lift up the cover of the unit ‘s 12 volt DC socket.  
2 Insert the 12 volt DC plug from the appliance into the cigarette lighter type socket on the unit.  
DO NOT EXCEED A 15 AMP LOAD.  
3. Switch on the appliance, as usual.  
4. Periodically press the Battery Status Pushbutton to check battery status.  
CAUTION: DO NOT OPERATE APPLIANCES THAT DRAW MORE THAN 15 AMPS.  
4.  
CHARGING/RECHARGING  
Lead-acid batteries require maintenance to maintain a full charge and to ensure good battery  
life. All batteries lose energy from self-discharge over time and more rapidly when they are at  
higher temperatures. Therefore, batteries need periodic charging to replace energy lost through  
self-discharge. When Start-It Compact is not in use, Vector recommends that the battery is  
recharged at least every 60 days.  
All batteries must be recharged as soon as possible after each use. If a battery is allowed to  
remain in a discharged state, battery life will be reduced.  
NOTE: RECHARGING BATTERY AFTER EACH USE WILL PROLONG BATTERY LIFE;  
FREQUENT HEAVY DISCHARGES BETWEEN RECHARGES WILL REDUCE BATTERY LIFE.  
OVERCHARGING WILL REDUCE BATTERY LIFE.  
The battery can be recharged using an AC adapter or DC adapter. See figures 3a and 3b - AC  
Recharge Adapter and DC Recharge Adapter.  
12 VOLT AC  
PLUG ADAPTER  
FIGURE 3  
(A)  
(B)  
110 VOLT DC  
WALL ADAPTER  
Check the battery charge level by pressing the Charge Status Button. The LED Charge Status  
display will indicate the level of charge of the main battery When only one red LED lights, be  
sure to recharge the unit.  
4.1  
AC RECHARGE  
The AC Recharge Adapter is a UL approved “wall” type unit that operates from any 110 volt,  
60 Hz AC supply that has a standard North American receptacle. The wire has a barrel con-  
nector that plugs into the unit to recharge the internal battery. See Figure 3A AC Recharge  
Adapter.  
Make sure that the Safety Switch and the Work light are turned off during AC recharge. When  
a powered AC Recharge adapters barrel connector is plugged into the Recharge Port, the  
Battery Status Display will automatically activate. As recharge progresses, the red LEDs will  
light one by one. Charge the unit until the Battery Status Display lights the or flashes the green  
FULL LED. Continue to recharge for one to two hours, and then disconnect the AC Recharge  
Adapter. AC recharge system is an automatic taper charge and The AC Recharge Adapter can  
be left connected to the Main Unit for long periods. See Figure 1 for AC Recharge port location  
of the Start-It..  
 
9
4.2  
DC RECHARGE  
Recharging the Main Unit from an external DC power source requires the use of the DC/DC  
Recharge Cable. This cable has a DC connector at each end. See Figure 3B.  
MAKE SURE SAFETY ON/OFF SWITCH AND WORKLIGHT ARE TURNED OFF  
DURING RECHARGE, THIS MAY SLOW RECHARGE OF THE MAIN BATTERY.  
Unlike the AC Recharge method, DC Recharge does not automatically activate the Battery  
Status Display and provide a taper charge. To check the battery status, press the Battery Status  
Display Pushbutton. If the Jump Starters battery is fully discharged, it is recommended that the  
host vehicle or boats engine being used for recharging be left operating while the unit is being  
charged using the 12 volt DC/DC method.  
NOTE: The DC recharge method will recharge the units battery, but the green LED may not  
light if the charging source is below 12.6 volts.AC recharge is the best method.  
WARNING: DO NOT RECHARGE MAIN UNIT FOR MORE THAN 3 HOURS MAXIMUM  
USING 12 VOLT DC METHOD. DO NOT LEAVE UNIT UNATTENDED WHILE  
DC CHARGING.  
1. Insert the DC Plug of the DC Recharge Adapter into a DC Recharge/Accessory socket on the  
unit.  
2. Plug the other DC Plug into an accessory socket in a vehicle, power supply or other 12 volt  
DC source.  
3. Charge the unit until the green CHARGED indicator is lit when the Charge Status Button is  
pressed - DO NOT EXCEED 3 HOURS MAXIMUM.  
4. After charging, disconnect the cables and store them in the Cable Storage Hatch.  
5.  
MAINTENANCE/REPLACEMENT PARTS  
For replacement parts (bulbs, batteries, charging adapters, etc.), contact Vector Technical  
Support: (954) 584-4446 or toll free at 866-584-5504. Except a lamp in the worklight, there  
are no user serviceable parts inside the unit. Periodically, the cables and connectors should be  
inspected for damage, corrosion and dust and dirt. If surfaces are dirty, they can be wiped  
clean with a cloth moistened with water and a drop of detergent. Contacts can be wiped clean  
with a dry cloth.  
WARNINGS: OTHER THAN A BULB IN THE WORKLIGHT, THERE ARE NO USER SERVICABLE  
PARTS INSIDE. DO NOT OPERATE UNIT IF THERE IS ANY EVIDENCE OF DAMAGE.THE  
PRODUCT MUST BE RETURNED TO VECTOR FOR TESTING AND REPAIR. REPLACE ANY  
DAMAGED CHARGING ADAPTERS IMMEDIATELY BEFORE FURTHER USE.  
5.1  
LAMP REPLACEMENT  
You will need a small Phillips head type screwdriver and a “PR type” 12volt 0.2 ampere bulb.  
1. Make sure the Work Light /area light is turned off.  
2. Remove the two Phillips type screws (turn counter-clockwise).  
3. Lift off lens and set it aside.  
4. Using the clean cloth, rotate the burned out bulb until the bulb is in the position where the  
reflector has a triangular gap.  
5. Lift the bulb straight out.  
NOTE: DO NOT USE ANY METAL TOOLS TO REMOVE OR REPLACE BULB  
6. Carefully replace with a new bulb (12 volt 0.2 amp bulb (type PR).  
7. Rotate the bulb so the triangle gap and bulb are not aligned.  
8. Snap the lens into place and replace the two screws.  
9. Turn screws clockwise to tighten, being careful NOT TO OVER-TIGHTEN.  
 
10  
6.  
BATTERY DISPOSAL  
Contains a maintenance-free, sealed, non-spillable, lead acid battery, which must be disposed  
of properly. Recycling is required -contact your local authority for information. Failure to  
comply with local, state and federal regulations can result in fines, or imprisonment.  
BATTERY DISPOSAL WARNINGS  
• Do not dispose of the battery in fire as this may result in an Explosion  
• Before disposing of the battery, protect exposed terminals with heavy-duty electrical tape to  
prevent shorting (shorting can result in injury or fire)  
• Do not expose battery to fire or intense heat as it may explode  
7.  
SPECIFICATIONS  
Jump-Start Clamps ......................................................... 300 Amps - Heavy Duty Copper  
Jumper Cables ........................................................................... #6AWG Welding Cable  
Peak Amps............................................................................................................... 600  
CA Cranking Amps .................................................................................................. 225  
BatteryHigh Density AGM..................................... 12 Volt 9 Amp Hour, Sealed Lead-Acid  
Worklight Bulb .................................................................................... 0.2 Amp, 12 VDC  
Accessory Socket Protection ............................................. 15 Amps Self-Resetting Breaker  
Height ...................................................................................................8.5 in (21.3 cm)  
Width .....................................................................................................10 in (25.4 cm)  
Depth. ...................................................................................................4.4 in (11.2 cm)  
Weight. ................................................................................................ 8.5 lbs (3.86 kg)  
TWO YEAR LIMITED WARRANTY PROGRAM  
This limited warranty program is the only one that applies to this product, and it sets forth all the  
responsibilities of Vector Manufacturing, Ltd., regarding this product. There is no other  
warranty, other than those described herein.  
This Vector Manufacturing, Ltd. product is warranted, to the original purchaser only, to be free  
of defects in materials and workmanship for10 days from the date of purchase without  
additional charge. The warranty does not extend to subsequent purchasers or users. Vector  
Manufacturing, Ltd. will not be responsible for any amount of damage in excess of the retail  
purchase price of the product under any circumstances. Incidental and consequential damages  
are specifically excluded from coverage under this warranty.  
This product is not intended for commercial use. This warranty does not apply to accessories or  
damage to units from misuse or incorrect installation. Misuse includes wiring or connecting to  
improper polarity power sources.  
RETURN/REPAIR POLICY: Defective products, other than accessories, may be returned postage  
prepaid to Vector Manufacturing. Any defective product, other than accessories, that is  
returned to Vector Manufacturing within 10 days of the date of purchase will be replaced free  
of charge. If such a product is returned more than 10 days but less than 120 days from the  
purchase date, Vector Manufacturing will repair the unit or, at its option, replace it free of  
charge.  
 
11  
If the unit is repaired, new or reconditioned replacement parts may be used, at Vector  
Manufacturings option. A unit may be replaced with a new or reconditioned unit of the same  
or comparable design. The repaired or replaced unit will then be warranted under the terms of  
the remainder of the warranty period. The customer is responsible for the shipping charges on  
all returned items. During the warranty period, Vector Manufacturing, Ltd. will be responsible  
for the return shipping charges.  
LIMITATIONS: This warranty does not cover accessories, bulbs, fuses and batteries, defects  
resulting from normal wear and tear (including chips, scratches, abrasions, discoloration or  
fading due to usage or exposure to sunlight), accidents, damage during shipping to our service  
facility, alterations, unauthorized use or repair, neglect, misuse, abuse, failure to follow instruc-  
tions for care and maintenance, fire, flood, and Acts of God.  
If your problem is not covered by this warranty, call our Technical Support Department at  
(954) 584-4446 or toll free at 866-584-5505 for general repair information and charges if  
STATE LAW RIGHTS: This warranty gives you specific legal rights. Some states do not allow  
limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or  
consequential damages, so the exclusions or limitations stated herein may not apply. This war-  
ranty gives the purchaser specific legal rights; other rights, which vary from state to state, may  
apply.  
TO REQUEST WARRANTY SERVICE FOR THIS PRODUCT: Contact Vector Manufacturing  
Technical Support by telephone, fax or mail. We suggest that you keep the original packaging  
in case you need to ship the unit. When returning a product, include your name, address,  
phone number, dated sales receipt (or copy), and a description of the reason for return and  
product serial number. After repairing or replacing the unit, we will attempt to make every  
effort to return it to you within four weeks.  
WARRANTY ACTIVATION: Please complete Warranty Activation Card and mail to Vector  
Manufacturing. Enter “VEC016” as Model and Start-it Compact as “Product Type”. All Vector  
Manufacturing, Ltd. products must be registered within (10) days of purchase to activate this  
warranty. Mail the completed registration form, along with a copy of the original sales receipt  
to:  
ATTN.: CUSTOMER SERVICE / VECTOR MANUFACTURING, Ltd.  
4140 SW 28th Way, Ft. Lauderdale, FL 33312  
PH: 954-584-4446 • TOLL FREE: 866-584-5504 • Fax: 954-584-5556.  
WARRANTY MUST BE PURCHASED WITHIN 10 DAYS OF PRODUCT PURCHASE DATE.  
WARRANTY IS NON-TRANSFERABLE AND NON-REFUNDABLE.  
© 2003 VECTOR MANUFACTURING, Ltd. • FT. LAUDERDALE, FL 33312 MADE IN CHINA  
 

Taylor Scale 7405 User Manual
Taylor Thermometer 806E User Manual
Thermos Charcoal Grill 465630503 User Manual
Tripp Lite Network Cables N201 002 BL User Manual
Tripp Lite Surge Protector P036 002 User Manual
Unitech Stereo System PA966 User Manual
Universal Remote Control Universal Remote UR3 SR User Manual
ViewSonic Projector PJD6211P User Manual
VTech Cordless Telephone USB7200 User Manual
Vulcan Hart Griddle ML 136221 00G24 User Manual