Toshiba Digital Camera IK TF7C User Manual

INSTRUCTION MANUAL  
3 CCD CAMERA  
IK-TF7C  
For Customer Use  
Enter below the Serial No.  
which is located on the  
bottom of the cabinet. Retain  
this information for future ref-  
erence.  
Model No.: IK-TF7C  
Serial No.:  
FCC NOTICE  
This equipment has been tested and found to comply with the limits for a Class A digital device, pursu-  
ant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against  
harmful interference when the equipment is operated in a commercial environment. This equipment  
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance  
with the instruction manual, may cause harmful interference to radio communications. Operation of this  
equipment in a residential area is likely to cause harmful interference in which case the user will be  
required to correct the interference at his own expense.  
USER-INSTALLER CAUTION:Your authority to operate this FCC verified equipment could be voided if  
you make changes or modifications not expressly approved by the party responsible for compliance to  
Part 15 of the FCC Rules.  
This Class A digital apparatus complies with Canadian ICES-003.  
Cet appareil numérique de la classe A est comforme à la norme NMB-003 du Canada.  
Following information is only for EU-member states:  
The use of the symbol indicates that this product may not be treated as household waste.  
By ensuring this product is disposed of correctly, you will help prevent potential negative  
consequences for the environment and human health, which could otherwise be caused by  
inappropriate waste handling of this product. For more detailed information about the take-  
back and recycling of this product, please contact your supplier where you purchased the  
product or consult.  
 
Note the following instructions when installing.  
• Do not cover the product by any material.  
• Do not put the product on an Inflammable material such as carpet or blanket.  
• Do not put the product in a narrow space, since the heat generated from the  
product may be difficult to emanate.  
If you do not follow the above, the heat generated by the product may cause fire.  
Do not put the product in direct sunshine and/or high temperature.  
The temperature inside the product may cause fire.  
Avoid setting in humid, smoky, vaporized or dusty places.  
This may cause fire and/or electric shock.  
Do not point the lens directly at the sun and/or intensive light such as di-  
rect sunlight, etc.  
Focusing of the light may cause injury of eye and/or fire.  
Ask your dealer to perform a periodical check and internal cleaning (approx.  
once every five years).  
Dust inside the product may cause fire and/or trouble. For check and cleaning  
cost, please consult your dealer.  
Disclaimer  
We disclaim any responsibility and shall be held harmless for any damages or losses incurred by the  
user in any of the following cases:  
1. Fire, earthquake or any other act of God; acts by third parties; misuse by the user, whether inten-  
tional or accidental; use under extreme operating conditions.  
2. Malfunction or non-function resulting in indirect, additional or consequential damages, including  
but not limited to loss of expected income and suspension of business activities.  
3. Incorrect use not in compliance with instructions in this instruction manual.  
4. Malfunctions resulting from misconnection to other equipment.  
5. Repairs or modifications made by the user or caused to be made by the user and carried out by  
an unauthorized third party.  
6. Notwithstanding the foregoing, Toshiba’s liabilities shall not, in any circumstances, exceed the  
purchase price of the product.  
Copyright and Right of Portrait  
There may be a conflict with the Copyright Law and other laws when a customer uses, displays,  
distributes, or exhibits an image picked up by the camera without permission from the copyright  
holder. Please also note that transfer of an image or file covered by copyright is restricted to use  
within the scope permitted by the Copyright Law.  
3
 
TABLE OF CONTENTS  
1. CAUTIONS ON USE AND INSTALLATION ..... 5 7. 3 External Sync ............................................ 22  
( 1 ) External sync signal input conditions ...... 22  
( 2 ) External sync frequency range ............... 22  
( 3 ) Using the unit with external sync signal .. 23  
(3. 1) H (horizontal) phase adjustment ...... 23  
2. COMPONENTS ................................................ 5  
3. ITEMS CONTROLLED BY USING  
ON SCREEN DISPLAY .................................... 6  
( 4 ) Changing HD/VD input/output ................ 23  
4. NAMES AND FUNCTIONS .............................. 7  
5. CONNECTION .................................................. 8  
7. 4 Synchro. Scan Operation ......................... 23  
( 1 ) Setting by 1H .......................................... 23  
( 2 ) Setting by the frame ................................ 23  
5. 1 Standard Connection ................................ 8  
5. 2 Cautions on Connection ........................... 8  
5. 3 Connector Pin Assignments ..................... 8  
7. 5 EXT TRIG (External trigger) ..................... 24  
( 1 ) 1P SNR (1 Pulse Sync Non Reset) ........ 24  
(1. 1) 1 Pulse Trigger SYNC-NON RESET  
Picture Output Timing ...................... 24  
(1. 2) 1 Pulse Trigger SYNC-NON RESET  
Picture Output Timing (at Time of  
6. OPERATION ..................................................... 9  
6. 1 White Balance........................................... 9  
6. 2 Gain ........................................................ 10  
6. 3 Shading Correction ................................. 10  
Internal Sync) ................................... 25  
7. MODE SETTING BY ON SCREEN DISPLAY ..... 11  
( 2 ) 1P SR (1 Pulse Sync Reset)................... 26  
(2. 1) 1 Pulse Trigger SYNC-RESET Picture  
Output Timing ................................... 26  
7. 1 Using the Menus ..................................... 11  
7. 2 Menus ..................................................... 12  
( 1 ) SHUTTER (Electronic shutter)................ 12  
(1. 1) Changing each setting in  
( 3 ) PW SNR (Pulse width trigger  
SYNC-NON RESET) .............................. 27  
(3. 1) Pulse Width Trigger SYNC-NON RESET  
Picture Output Timing ...................... 27  
(3. 2) Pulse Width Trigger SYNC-NON RESET  
Picture Output Timing (at Time of  
MANU mode ..................................... 12  
(1. 2) Changing each setting in  
SS (synchro. scan) mode ................. 13  
(1. 3) Changing each setting in  
E.TRG mode..................................... 14  
(1. 3. 1) Changing each setting in  
1P SNR mode ............................... 14  
(1. 3. 2) Changing each setting in  
1P SR mode ................................. 15  
(1. 3. 3) Changing each setting in  
PW SNR mode ............................. 16  
(1. 3. 4) Changing each setting in  
PW SR mode ................................ 17  
(1. 3. 5) Changing each setting in  
RR mode ....................................... 18  
Internal Sync) ................................... 28  
( 4 ) PW SR (Pulse width trigger  
SYNC-RESET) ....................................... 29  
(4. 1) 1 Pulse Width Trigger SYNC-RESET  
Picture Output Timing ...................... 29  
( 5 ) RR (Reset restart) .................................. 30  
(5. 1) Long Term Exposure ........................ 30  
(5. 2) Input Timing Chart Example ............ 30  
7. 6 Partial Scanning ........................................ 31  
( 1 ) Partial Scanning OFF  
( 2 ) GAIN (Video gain)................................... 18  
(2. 1) Changing each setting in GAIN........ 18  
( 3 ) WHT BAL (White balance)...................... 19  
(3. 1) Changing each setting in AWB  
(All pixels scanning) ................................ 31  
( 2 ) Partial Scanning ON ............................... 31  
( 3 ) When Partial Scanning Mode is ON ....... 31  
8. INPUT OUTPUT SIGNAL SPECIFICATOINS ........ 32  
(Automatic White Balance) mode .... 19  
(3. 2) Changing each setting in MANU  
(Manual) mode ................................. 19  
( 1 ) HD/VD Output Amplitude Specifications ... 32  
( 2 ) VD Input Specifications........................... 32  
( 3 ) VIDEO INDEX Output Specifications..... 32  
( 4 ) HD Input Specifications .......................... 32  
( 5 ) Trigger Pulse Specifications.................... 32  
( 4 ) PROCESS .............................................. 20  
(4. 1) Changing master pedestal ............... 20  
(4. 2) Changing R pedestal ........................ 20  
(4. 3) Changing B pedestal ........................ 20  
(4. 4) Changing the shading correction mode ... 20  
(4. 5) Changing the manual shading correction setting ... 20  
( 6 ) External HD/VD Input Phase  
Specifications.......................................... 32  
( 5 ) SYNC ...................................................... 21  
(5. 1) Adjusting horizontal phase ............... 21  
( 6 ) OPTION .................................................. 21  
(6. 1) Changing serial communication baud  
rate .................................................... 21  
9. CCD OUTPUT WAVEFORM TIMING CHART ... 33  
( 1 ) Horizontal Output Waveform Timing Chart ... 33  
( 2 ) Vertical Output Waveform Timing Chart... 33  
10. SPECIFICATIONS ....................................... 34  
11. EXTERNAL APPEARANCE DIAGRAM ...... 35  
12. BEFORE MAKING A SERVICE CALL ........ 35  
( 7 ) Setting to factory setting status............... 22  
4
 
1. CAUTIONS ON USE AND INSTALLATION  
Carefully handle the units.  
Handling of the protection cap.  
Do not drop, or give a strong shock or vibration to  
the camera. This may cause problems. Treat the  
camera cables carefully to prevent cable problems,  
such as cable breakdown and loosened connec-  
tions.  
Keep the protection cap away from children. Chil-  
dren may put them into mouth or swallow them  
accidentally. The protection cap protects the im-  
age sensing plane when the lens is removed from  
the camera, do not throw away.  
Do not shoot intense light.  
When not using the camera for a longtime.  
Stop supplying power.  
If there is an intense light at a location on the  
screen such as a spot light, a blooming and smear-  
ing may occur. When intense light enters, vertical  
stripes may appear on the screen. This is not a  
malfunction. Ghosts may occur when there is an  
intense light near the object. In this case, change  
the shooting angle.  
When cleaning the camera.  
Unplug the power source before cleaning. Clean  
with a soft dry cloth only. Do not use benzine, al-  
cohol, thinner, household detergents, chemically  
treated cloths, etc. If used, coating and printed  
letters may be discolored.When cleaning the lens,  
use a lens cleaning paper, etc.  
Install the camera in a location free from noise.  
If the camera or the cables are located near power  
utility lines or a TV, etc. undesirable noise may ap-  
pear on the screen. In such a case, try to change  
the location of the camera or the cable wiring.  
Avoid using or storing the camera in the fol-  
lowing places:  
Places filled with highly flammable gas.  
Places near gasoline, benzene, or paint thinner.  
Places subject to strong vibration.  
Moire  
When thin stripe patterns are shot, stripe patterns  
that are not actually there (moire) may appears  
as interference stripes. This is not a malfunction.  
Places contacting chemicals (such as pesticides),  
rubber or vinyl products for a long period of time.  
Operating ambient temperature and humidity.  
Do not use the camera in places where tempera-  
ture and humidity exceed the specifications. Pic-  
ture quality will lower and internal parts may be  
damaged.  
Be particularly careful when using in places ex-  
posed to direct sunlight. When shooting in hot  
places, depending on the conditions of the object  
and the camera (for example when the gain is in-  
creased), noise in the form of vertical strips or  
white dots may occur. This is not a malfunction.  
2. COMPONENTS  
(1) Camera ...........................................................................................................................................1  
(2) Accessories  
(a) Instruction manual ...................................................................................................................1  
5
 
3. ITEMS CONTROLLED BY USING ON SCREEN DISPLAY  
Preset value  
(Factory setting)  
Item  
MODE  
E. TRG  
MANU speed  
Available selections  
MANU, SS, E. TRG  
1P SNR, 1P SR, PW SNR, PW SR, RR  
OFF, 1/100s, 1/250s, 1/500s, 1/1000s, 1/2000s,  
MANU  
1P SNR  
OFF  
1/4000s, 1/10000s, 1/25000s, 1/50000s, 1/1000000s  
Syncro. Partial scanning OFF 1H/796H~795H/796H, OFF, 2FRM~512FRM  
scan. Partial scanning 60fps 1H/387H~386H/387H, OFF, 2FRM~512FRM  
OFF  
OFF  
Partial scanning 90fps  
1H/258H~257H/258H, OFF, 2FRM~512FRM  
OFF, 60 fps, 90 fps, E.60 fps, E.90 fps  
Partial scanning  
Trigger  
(1P SNR/SR)  
Trigger  
(PW SNR/SR)  
,
,
1P  
16 ms  
0.01ms~16ms  
exposure time  
MODE  
MANU  
MODE  
Color temperature  
MANUAL R GAIN  
MANUAL B GAIN  
Master pedestal  
R pedestal  
MANU, OFF  
-3dB~18dB  
AWB, MANU  
3200K, 5600K  
-100~0~100  
-100~0~100  
-64~0~64  
OFF  
0dB  
AWB  
3200K  
0
0
0
0
0
-64~0~64  
-64~0~64  
B pedestal  
Shading correction  
mode  
MANU, OFF  
MANU  
Manual shading  
correction  
H phase adjustment  
-128~0~127  
-100~0~100  
0
0
Baud rate  
9600 bps, 19200 bps  
9600 bps  
6
 
4. NAMES AND FUNCTIONS  
8
2
4
DC IN 12V terminal  
DISP button  
1 Prism faceplate  
MENU UP button  
(AWB)  
DISP  
6
7
DATA UP (AWB) button  
DATA DOWN button  
MENU DATA  
DC IN 12V  
PAGE  
5 MENU DOWN button  
9
DIGITAL terminal  
3 PAGE button  
[ Front ]  
[ Rear ]  
Prism faceplate  
The protection cap is attached on the lens mount portion. After removing the cap,  
mount the lens. Be careful not to scratch or touch the optical area.  
1
DISP button  
Used when switching the display.  
2
3
4
5
6
PAGE button  
Used when switching to the menu and when selecting the menus.  
Select the function to be confirmed or changed on the menu.  
Select the function to be confirmed or changed on the menu.  
MENU UP button  
MENU DOWN button  
DATA UP (AWB) button  
Changes the value of the function selected by the MENU (UP/DOWN) button.  
(Also used when using AWB.)  
DATA DOWN button  
DC IN 12V terminal  
RGB terminal  
Changes the value of the function selected by the MENU (UP/DOWN) button.  
Accept a DC power input (12V).  
7
8
9
8-bit RGB, digital signal, and sync signal are output in the Camera Link format.  
Trigger signal and external sync signal (HD,VD) are input.  
Mode switching signal for partial scanning is input.  
Accepts serial communication control signal.  
7
 
5. CONNECTION  
5. 1 Standard Connection  
Lens  
Cable (not included)  
DC IN 12V  
IK-TF7C  
Frame grabber board,  
Monitor  
Less than 4 mm  
image process  
equipment etc.  
DC power  
supply  
5. 2 Cautions on Connection  
• When connecting the camera cables, unplug the power source of the camera and the other equipment  
connected.  
• We suggest using a C mount lens made for a 3CCD camera.  
When using another lens, the best camera performance of this camera may not be obtained.  
(For example, low resolution may occur, focus may be lost through the range of a zoom lens, and  
flare, ghost or shading may occur)  
Furthermore, in order to avoid damaging the mounting portion of the camera head, use a lens which  
has projection dimension from the mounting base of less than 0.157"(4mm).  
• For DC power supply connecting to DC IN 12V terminal, use UL listed and/or CSA approved ungrounding  
type AC adaptor with the specifications described below.  
Power supply voltage  
Current rating  
Ripple voltage  
Connector  
: DC12V 10%  
: More than 830 mA  
: Less than 50 mV(p–p)  
: HR10A–7P–4S by HIROSE electronics Co. Ltd  
Pins 1, 2 : 12V  
Pins 3, 4 : GND  
5. 3 Connector Pin Assignments  
Function  
I/O  
O
O
O
O
O
I
DC IN 12V  
DIGITAL  
1
2
3
4
5
6
7
8
9
GND  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
GND  
X0+  
1
2
3
4
+12V  
+12V  
GND  
GND  
X0-  
X1-  
X1+  
13  
26  
1
X2-  
X2+  
Xcllk-  
X3-  
Xcllk+  
X3+  
14  
SerTC+  
SerTC-  
Serial communication control (RXD)  
Serial communication control (TXD)  
Trigger pulse input  
1
2
3
4
O
I
SerTFC-  
CC1-  
SerTFC+  
CC1+  
CC2-  
Connector used:  
12226-51000-00  
10 CC2+  
CC3-  
12 CC4+  
GND  
Partial scanning control  
External HD input  
I
(3M) or equivalent.  
CC3+  
CC4-  
11  
I
Connector used:  
I
External VD input  
HR10A-7P-4PB  
GND  
13  
(HIROSE electronics  
Co. Ltd) or equivalent.  
8
 
6. OPERATION  
Refer to the item " 5. CONNECTION", connect each equipment correctly.  
Turn on the connected equipment and the power source of the camera.  
1
2
3
4
5
Point the lens at the object, operate the lens iris adjustment, focus adjustment, etc..  
Refer to the item "6.1 White Balance", operate the adjustment.  
Refer to the items "6.2 Gain, 7. MODE SETTING BY ON SCREEN DISPLAY", select the necessary items.  
6. 1 White Balance  
For the white balance adjustment for this unit, AWB (Automatic White Balance) and MANU (Manual white  
balance) adjustments are provided. To select the desired mode, refer to the items 7.2 (3) WHT BAL (White  
balance)and 7. MODE SETTING BY ON SCREEN DISPLAY.  
AWB  
MANU  
(Automatic White Balance)  
(Manual White Balance)  
Outline  
Note  
Adjust white balance by shooting the white Adjust the white balance manually using  
object inside the area set by AWB menu  
and pressing the [DATA UP] button.  
the WHT BAL menu while shooting the  
white object.  
When the shutter mode is E.TRG, AWB is Adjustment is performed by confirming  
not available. with a monitor etc.  
AWB (Automatic white balance)  
1
Set the MODE to AWB on the WHT BAL menu.  
Perform the C.TEMP (color temperature conversion) setting, if necessary.  
(Refer to the item "7.2 (3) WHT BAL (White balance)".)  
3200K : Appropriate for indoor shooting.  
5600K : Appropriate for outdoor shooting.  
If the index menu/menu is displayed, press the [DISP] button to disable the character display on the  
menu.  
Shoot a known white object that fills the screen and push [DATA UP] button for approx. 1 second.  
The character AWB blinks on the screen when the AWB starts.  
The character AWB stops blinking when the AWB finishes, and the result is displayed for approx. 1  
second.  
Result displayed  
Meaning  
AWB OK  
Automatic white balance adjustment finished correctly.  
AWB NG LEVEL  
LOW  
Automatic white balance adjustment cannot be performed because the  
video level is too low.  
Get the video level propely.  
AWB NG  
LEVEL HIGH  
Automatic white balance adjustment cannot be performed because the  
video level is too high.  
Get the video level propely.  
AWB NG  
C. TEMP HIGH  
Automatic white balance adjustment cannot be performed because the  
color temperature is too low.  
If the C.TEMP is set to 5600K, set to 3200K.  
If the message appears with the C.TEMP set to 3200K, change the  
illumination or use a color temperature conversion filter.  
AWB NG  
C. TEMP HIGH  
Automatic white balance adjustment cannot be performed because the  
color temperature is too high.  
If the C.TEMP is set to 3200K, set to 5600K.  
If the message appears with the C.TEMP set to 5600K, change the  
illumination or use the color temperature conversion filter.  
9
 
Result displayed  
Meaning  
AWB NG  
NOT AVAILABLE  
Automatic white balance adjustment cannot be performed because the  
shutter speed mode is E.TRG mode.  
AWB NG  
Automatic white balance adjustment cannot be performed for other  
reasons. Such as no white area is included in an object, etc.  
MANU (Manual white balance)  
2
Set the MODE to MANU on the WHT BAL menu.  
(Refer to the item "7.2 (3) WHT BAL (white balance)".)  
Shoot a known white object, adjust the white balance adjusting the levels of R GAIN and B GAIN on the  
menu, confirming with a monitor or a monitor etc.  
(Refer to the item "7.2 (3) (3.2) Changing each setting in MANU mode".)  
6. 2 Gain  
When the image is dark even if the lens iris is open, change the gain (video gain) to get the proper video level.  
For the gain adjustment of the unit, MANU (Manual) and OFF (0 dB) modes are provided. Select the mode on  
the GAIN menu. (Refer to the item "7.2 (2) GAIN (Video gain)".)  
MANU (Manual gain)  
1
2
Gain adjustment is performed on the GAIN menu. The adjustment range is from -3dB to 18dB in 1dB steps.  
(Refer to the item "7.2 (2) (2.1) (a) Changing the gain in MANU mode".)  
OFF  
Gain is fixed at 0 dB.  
6. 3 Shading Correction  
Due to the lens used or the environmental condition, vertical color shading may occur at the top and bottom of  
the screen. In this case, the shading correction can decrease the color shading. For the shading correction of  
the unit, MANU (Manual shading correction) and OFF (no shading correction) modes are provided. Select the  
mode on the PROCESS menu. (Refer to the item "7.2 (4) (4.4) Changing the shading correction mode".)  
MANU (Manual Shading)  
1
Adjust the correction amount on the PROCESS menu by confirming with a monitor or a waveform monitor.  
(Refer to the "7.2 (4) (4.5) Changing the manual shading correction setting".)  
OFF  
2
The status is no shading correction.  
* The shading correction is effective when the lens iris or zoom ratio is fixed. Use the unit with SHAD.  
OFF for variable lens conditions.  
10  
 
7. MODE SETTING BY ON SCREEN DISPLAY  
Various settings can be controlled on the unit by using the on screen menu displayed on the monitor. The  
contents once set are memorized even if the power source is turned off, so it is unnecessary to set again when  
using the unit next time. When the setting is performed, select the menu of the item to be set.  
7. 1 Using the Menus  
When the power is turned on, the normal screen showing only the shooting image appears. Change the output  
to each screen (video signal output, Index menu, and menus) by using the [DISP], [PAGE], [MENU UP], and  
[MENU DOWN] buttons.  
* A menu is selected when pushing the [PAGE] button after moving the "" on the screen by the [MENU UP],  
[MENU DOWN] button while the Index menu is displayed.  
POWER ON  
Video signal output  
Index menu  
DISP  
DISP  
DISP  
PAGE  
PAGE  
Menus  
PAGE  
WHT BAL  
SHUTTER  
GAIN  
PROCESS  
SYNC  
INT  
OPTION  
SHAD.  
MANU  
BAUD  
RATE  
PAGE  
PAGE  
MANU  
PAGE  
AWB  
PAGE  
MANU  
SS  
PAGE  
SHAD.  
OFF  
EXT  
MANU  
OFF  
E. TRG  
1P SR  
E. TRG  
1P SNR  
E. TRG  
PW SR  
E. TRG  
PW SNR  
E. TRG  
RR  
11  
 
7. 2 Menus  
Select the menu to change the setting by referring the item "7.1 Using the Menus".)  
When the [MENU UP], [MENU DOWN] buttons are pushed, the "" on the screen moves up and down.  
Move the "" to the item to change.  
Note:  
When performing the mode setting in the menu display while selecting ON in "PART" and E.TRG in  
"MODE", the display shows normal mode and then the camera returns the setting mode.  
( 1 ) SHUTTER (Electronic shutter)  
The electronic shutter has three modes; MANU (Manual), SS (Synchro. Scan), E.TRG (External trigger).  
Set the "" to "MODE" and push [DATA UP], [DATA DOWN] button to select the desired mode among "MANU",  
"SS", "E.TRG".  
(1. 1) Changing each setting in MANU mode  
Move up down  
Set by pushing  
By pushing  
MENU UP, DOWN  
DATA UP, DOWN  
• Shutter mode MANU, SS, E.TRG  
-- SHUTTER --  
• Shutter speed setting  
OFF, 100 (1/100s), 250 (1/250s), 500 (1/500s)  
1000 (1/1000s), 2000 (1/2000s), 4000 (1/4000s)  
10000 (1/10000s), 25000 (1/25000s)  
MODE  
MANU  
PART  
MANU  
50000  
OFF  
50000 (1/50000s)100000 (1/100000s)  
• Partial scanning switch  
OFF/60fps/90fps/E.60fps/E.90fps  
<MODE = MANUAL>  
(a) Changing the shutter speed  
Set the "" to MANU by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Set the shutter speed by pushing [DATA UP], [DATA DOWN] buttons.  
(b) Partial scanning setting  
Set the "" to PART by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Select either OFF/60fps/90fps/E.60fps/E.90fps by pushing [DATA UP], [DATA DOWN] buttons.  
12  
 
(1. 2) Changing each setting in SS (synchro. scan) mode  
Move up down  
Set by pushing  
By pushing  
MENU UP, DOWN  
DATA UP, DOWN  
Shutter mode MANU, SS, E.TRG  
Synchro. scanning setting  
-- SHUTTER --  
OFF : 1H/796H795H/796HOFF2FRM512FRM  
60fps, E.60fps : 1H/387H386H/387HOFF2FRM512FRM  
90fps, E.90fps : 1H/258H257H/258HOFF2FRM512FRM  
MODE  
SS  
PART  
SS  
OFF  
OFF  
Partial scanning switch  
OFF/60fps/90fps/E.60fps/E.90fps  
<MODE = SS>  
(a) Changing the shutter speed setting  
Set the "" to SS by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Select the shutter speed by pushing [DATA UP], [DATA DOWN] buttons.  
(b) Partial scanning setting  
Set the "" to PART by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Select either OFF/60fps/90fps/E.60fps/E.90fps by pushing [DATA UP], [DATA DOWN] buttons.  
Note:  
The slow shutter speed may increase the fixed pattern noise and/or the white pixels. This is a charac-  
teristic of CCD, and is not a symptom of malfunction.  
13  
 
(1. 3) Changing each setting in E.TRG mode  
The E.TRG has five modes; 1P SNR, 1P SR, PW SNR, PW SR, RR.  
First set the "" to MODE and select E. TRG, then set the "" to E.TRG and select the desired E.TRG mode.  
(1. 3. 1) Changing each setting in 1P SNR mode  
Move up down  
Set by pushing  
By pushing  
MENU UP, DOWN  
DATA UP, DOWN  
Shutter mode MANU, SS, E.TRG  
-- SHUTTER --  
E.TRG mode  
1P SNR, 1P SR, PW SNR, PW SR, RR  
MODE  
E.TRG  
TRG.P  
EXP.  
E.TRG  
1P SNR  
Input trigger pulse setting at 1P SNR and 1P SR  
Input trigger pulse : positive polarity  
Input trigger pulse : negative polarity  
16ms  
OFF  
PART  
Exposure time setting at 1P SNR and 1P SR  
0.01 ms  
0.02 ms  
0.02 ms  
step  
0.4 ms  
0.1 ms  
step  
1 ms  
16 ms  
1 ms  
step  
0.01 ms  
step  
Partial scanning switch  
OFF/60fps/90fps/E.60fps/E.90fps  
<MODE = E.TRG E.TRG = 1P SNR>  
(a) Changing the polarity of inputting trigger pulse setting  
Set the "" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Select either  
,
by pushing [DATA UP], [DATA DOWN] buttons.  
(b) Changing 1P SNR exposure time setting  
Set the "" to EXP. by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Set the exposure time by pushing [DATA UP], [DATA DOWN] buttons.  
Note:  
The longer the storage time with extended exposures, the more visible certain characteristics of CCD  
cameras become: fixed pattern noise, white pixels, etc.  
(c) Changing the partial scanning setting  
Set the "" to PART by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Select either OFF/60fps/90fps/E.60fps/E.90fps by pushing [DATA UP], [DATA DOWN] buttons.  
14  
 
(1. 3. 2) Changing each setting in 1P SR mode  
Move up down  
Set by pushing  
By pushing  
MENU UP, DOWN  
DATA UP, DOWN  
Shutter mode MANU, SS, E.TRG  
-- SHUTTER --  
E.TRG mode  
1P SNR, 1P SR, PW SNR, PW SR, RR  
MODE  
E.TRG  
TRG.P  
EXP.  
PART  
E.TRG  
1P SR  
Input trigger pulse setting at 1P SNR and 1P SR  
Input trigger pulse : positive polarity  
Input trigger pulse : negative polarity  
16ms  
OFF  
Exposure time setting at 1P SNR and 1P SR  
0.01 ms  
0.02 ms  
0.02 ms  
step  
0.4 ms  
0.1 ms  
step  
1 ms  
16 ms  
1 ms  
step  
0.01 ms  
step  
Partial scanning switch  
OFF/60fps/90fps/E.60fps/E.90fps  
<MODE = E.TRG E.TRG = 1P SR>  
(a) Changing the polarity of inputting trigger pulse setting  
Set the "" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Select either  
,
by pushing [DATA UP], [DATA DOWN] buttons.  
(b) Changing 1P SR exposure time setting  
Set the "" to EXP. by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Set the exposure time by pushing [DATA UP], [DATA DOWN] buttons.  
Note:  
The longer the storage time with extended exposures, the more visible certain characteristics of CCD  
cameras become: fixed pattern noise, white pixels, etc.  
(c) Changing the partial scanning setting  
Set the "" to PART by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Select either OFF/60fps/90fps/E.60fps/E.90fps by pushing [DATA UP], [DATA DOWN] buttons.  
15  
 
(1. 3. 3) Changing each setting in PW SNR mode  
Move up down  
Set by pushing  
By pushing  
MENU UP, DOWN  
DATA UP, DOWN  
Shutter mode MANU, SS, E.TRG  
-- SHUTTER --  
E.TRG mode  
MODE  
E.TRG  
PW SNR  
1P SNR, 1P SR, PW SNR, PW SR, RR  
E.TRG  
TRG.P  
PART  
Input trigger pulse setting at PW SNR and PW SR  
Input trigger pulse : positive polarity  
OFF  
Input trigger pulse : negative polarity  
Partial scanning switch  
OFF/60fps/90fps/E.60fps/E.90fps  
<MODE = E.TRG E.TRG = PW SNR>  
(a) Changing the polarity of inputting trigger pulse setting  
Set the "" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Select either  
,
by pushing [DATA UP], [DATA DOWN] buttons.  
(b) Changing the partial scanning setting  
Set the "" to PART by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Select either OFF/60fps/90fps/E.60fps/E.90fps by pushing [DATA UP], [DATA DOWN] buttons.  
Note:  
The longer the storage time with extended exposures, the more visible certain characteristics of CCD  
cameras become: fixed pattern noise, white pixels, etc.  
16  
 
(1. 3. 4) Changing each setting in PW SR mode  
Move up down  
Set by pushing  
By pushing  
MENU UP, DOWN  
DATA UP, DOWN  
Shutter mode MANU, SS, E.TRG  
-- SHUTTER --  
E.TRG mode  
MODE  
E.TRG  
PW SR  
1P SNR, 1P SR, PW SNR, PW SR, RR  
E.TRG  
TRG.P  
PART  
Input trigger pulse setting at PW SNR and PW SR  
OFF  
Input trigger pulse : positive polarity  
Input trigger pulse : negative polarity  
Partial scanning switch  
OFF/60fps/90fps/E.60fps/E.90fps  
<MODE = E.TRG E.TRG = PW SR>  
(a) Changing the polarity of inputting trigger pulse setting  
Set the "" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Select either  
,
by pushing [DATA UP], [DATA DOWN] buttons.  
Note:  
The longer the storage time with extended exposures, the more visible certain characteristics of CCD  
cameras become: fixed pattern noise, white pixels, etc.  
17  
 
(1. 3. 5) Changing each setting in RR mode  
Move up down  
Set by pushing  
By pushing  
MENU UP, DOWN  
DATA UP, DOWN  
Shutter mode MANU, SS, E.TRG  
-- SHUTTER --  
E.TRG mode  
MODE  
E.TRG  
PART  
E.TRG  
RR  
OFF  
1P SNR, 1P SR, PW SNR, PW SR, RR  
Partial scanning switch  
OFF/60fps/90fps/E.60fps/E.90fps  
<MODE = E.TRG E.TRG = RR>  
(a) Changing the partial scanning setting  
Set the "" to PART by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Select either OFF/60fps/90fps/E.60fps/E.90fps by pushing [DATA UP], [DATA DOWN] buttons.  
Note:  
The longer the storage time with extended exposures, the more visible certain characteristics of CCD  
cameras become: fixed pattern noise, white pixels, etc.  
( 2 ) GAIN (Video gain)  
GAIN has two modes; MANU, OFF.  
Set the "" to MODE, push the [DATA UP], [DATA DOWN], and select mode among MANU, OFF. In the OFF  
mode, gain is fixed to 0dB.  
(2. 1) Changing each setting in GAIN  
Move up down  
Set by pushing  
By pushing  
MENU UP, DOWN  
DATA UP, DOWN  
-- GAIN --  
MODE  
MANU  
MANU  
0dB  
Gain mode MANU, OFF  
Manual gain -3 dB to 18 dB (10 dB step)  
(a) Changing the gain in MANU mode  
Set the "" to MANU by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Set the manual gain by pushing [DATA UP], [DATA DOWN] buttons.  
18  
 
( 3 ) WHT BAL (White balance)  
WHT BAL has two modes; AWB, MANU.  
Set the "" to MODE, push the [DATA UP], [DATA DOWN], and select mode among AWB, MANU.  
(3. 1) Changing each setting in AWB (Automatic White Balance) mode  
Move up down  
Set by pushing  
By pushing  
MENU UP, DOWN  
DATA UP, DOWN  
-- WHT BAL --  
MODE  
AWB  
White balance mode setting (AWB, MANU)  
C.TEMP  
3200  
Color temperature setting 3200, 5600  
(a) Changing color temperature setting  
Set the "" to C.TEMP by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Select either 3200 or 5600 by pushing [DATA UP], [DATA DOWN] buttons.  
(3. 2) Changing each setting in MANU (Manual) mode  
Move up down  
Set by pushing  
By pushing  
MENU UP, DOWN  
DATA UP, DOWN  
-- WHT BAL --  
MODE  
MANU  
White balance mode AWB, MANU  
Red gain adjustment -100 to 100  
Blue gain adjustment -100 to 100  
Color temperature setting 3200, 5600  
R GAIN  
B GAIN  
C. TEMP  
0
0
3200  
(a) Changing the red gain  
Set the "" to R GAIN by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Set the red gain by pushing [DATA UP], [DATA DOWN] buttons.  
(b) Changing the blue gain  
Set the "" to B GAIN by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Set the blue gain by pushing [DATA UP], [DATA DOWN] buttons.  
19  
 
( 4 ) PROCESS  
Move up down  
By pushing  
MENU UP, DOWN  
Set by pushing  
DATA UP, DOWN  
-- PROCESS --  
Master pedestal adjustment -64 to 64  
M.PED  
R.PED  
B.PED  
SHAD.  
MANU  
0
0
0
R pedestal adjustment -64 to 64  
B pedestal adjustment -64 to 64  
Shading mode setting MANU/OFF  
Manual shading adjustment -128 to 127  
MANU  
0
(4. 1) Changing master pedestal  
Set the "" to M. PED by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Set the master pedestal by pushing [DATA UP], [DATA DOWN] buttons.  
(4. 2) Changing R pedestal  
Set the "" to R. PED by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Set the R pedestal by pushing [DATA UP], [DATA DOWN] buttons.  
(4. 3) Changing B pedestal  
Set the "" to B. PED by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Set the B pedestal by pushing [DATA UP], [DATA DOWN] buttons.  
(4. 4) Changing the shading correction mode  
Set the "" to SHAD. by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Set the SHAD. by pushing [DATA UP], [DATA DOWN] buttons.  
Note: The alignment value for shading is fixed to "0" when selecting SHAD. OFF. MANU is not dis-  
played in the menu.  
(4. 5) Changing the manual shading correction setting  
Set the "" to MANU by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Set the MANUAL SHADING by pushing [DATA UP], [DATA DOWN] buttons.  
20  
 
( 5 ) SYNC  
When an external sync signal is input, the display menu changes from INT (internal sync) to EXT (external  
sync) automatically.  
Move up down  
Set by pushing  
By pushing  
MENU UP, DOWN  
DATA UP, DOWN  
-- SYNC --  
MODE  
H PHASE  
EXT  
0
Sync system display  
H PHASE -100 to 100  
(5. 1) Adjusting horizontal phase  
Set the "" to H PHASE by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Adjust the horizontal phase by pushing [DATA UP], [DATA DOWN] buttons.  
( 6 ) OPTION  
Move up down  
By pushing  
MENU UP, DOWN  
Set by pushing  
DATA UP, DOWN  
-- OPTION --  
BAUD RATE  
9600  
Serial baud rate 9600, 19200  
(6. 1) Changing serial communication baud rate  
Set the "" to BAUD RATE by pushing [MENU UP], [MENU DOWN] buttons.  
1
2
Select either 9600 or 19200 by pushing [DATA UP], [DATA DOWN] buttons.  
21  
 
( 7 ) Setting to factory setting status  
All the settings can be returned to the factory default status (preset status).  
(1) If characters are displayed on the screen, press the [DISP] button to disable the character display.  
(2) Push [MENU DOWN] and [DATA DOWN] buttons simultaneously for approx. 1 second.  
(3) The preset operation starts. When the preset operation finishes, the character PRESET OK is displayed  
for approx. 1 second.  
7. 3 External Sync  
When using the unit with an external sync signal, input HD and VD to CC3 and CC4 of the DIGITAL terminal.  
When the external sync signal is input, the camera automatically switches its sync from the internal sync to the  
external sync.  
The operation is as shown below, depending on the unit's status and how external sync signals are input.  
Shutter mode  
At time of SYNC-NON  
RESET mode  
HD input VD input  
Note  
N
Y
N
Y
N
Y
Y
N
Internal sync mode  
External sync mode  
Only V reset is applied due to VD input. Normally not used.  
HD is synchronized to external, but video is not output  
because there is no VD input. Normally not used.  
At time of SYNC-RESET  
mode  
N
Y
*
*
Internal sync mode. The presence of VD is ignored, and after  
a specified time after a trigger input, V reset is applied.  
HD is synchronized to external. The presence of VD is  
ignored, and after a specified time after a trigger input, V  
reset is applied.  
At time of reset restart  
Y
N
*
Y
Y
N
HD is synchronized to external. Video is output due to VD  
input.  
HD is synchronized to the inside of the camera. Video is  
output due to VD input.  
Video is not output because there is no VD input. Normally  
not used.  
At time of manual  
shutter  
N
Y
Y
N
N
Y
N
Y
Internal sync mode  
External sync mode  
HD is synchronized to external. Normally not used.  
Disabled  
* Either Y or N is permitted.  
( 1 ) External sync signal polarity  
HD: 2 to 5V(p-p) Negative  
VD: 2 to 5V(p-p) Negative  
( 2 ) External sync frequency range  
(External sync with HD, VD)  
Within 1% (at horizontal sync frequency of 23.229 kHz)  
22  
 
( 3 ) Using the unit with external sync signal  
When adjusting H (horizontal) phase refer to the item "7.2 (5) (5.1) Adjusting horizontal phase".  
External  
Sync. signal  
(3. 1) H (horizontal) phase adjustment  
Match  
the phase.  
Observe the external sync signal and the LVAL signal output  
waveform of the unit with a dual trace oscilloscope, and ad-  
just H phase so that the H phases match.  
LVAL signal  
output  
7. 4 Synchro. Scan Operation  
The shutter speed can be set by the horizontal scanning period (1H) or by the frame.  
( 1 ) Setting by 1H  
1H/796H to 795H/796H (1H/387H to 386H/387H when partial scanning at 60fps, E.60fps 1H/258H to 257H/  
258H when partial scanning at 90fps, E.90fps) stands for the setting by the 1H and the shutter speed can be  
set by the 1H (43.05 µs).  
( 2 ) Setting by the frame  
2FRM to 512FRM stand for the setting (long period exposure) by the frame.  
The video signal stored during the frame period set is output as 1 frame video image at a frame interval  
specified.  
(Internal VD)  
n
n+1  
RGB data  
(video interval image)  
FVAL  
LVAL,  
DAVL  
(4FRM setting)  
23  
 
7. 5 EXT TRIG (External trigger)  
Charge begins to accumulate after the trigger input to CC1 of the DIGITAL terminal, and 1 frame images are  
output. There are five modes: 1P SNR, 1P SR, PW SNR, PW SR, RR.  
( 1 ) 1P SNR (1 Pulse Trigger Sync Non Reset)  
Charge begins to accumulate after the trigger input to CC1 of the DIGITAL terminal, and 1 frame images are  
output.  
(1. 1) 1 Pulse Trigger SYNC-NON RESET Picture Output Timing  
Negative polarity mode  
Trigger*1  
Positive polarity mode  
About 1 µs  
Exposure period*2  
Exposure period*2  
External HD IN*1  
External VD IN*1  
About 1H  
(Internal VD)  
RGB data  
(video interval image)  
FVAL  
LVAL,  
DVAL  
28H (Partial scanning OFF)  
38H (Partial scanning 60fps)  
47H (Partial scanning 90fps)  
The internal VD falling edge is within the  
exposure period and thus video is not output.  
3
*
(At Time of One-shot or Continuous External VD/Continuous External HD Input)  
*1: Externally input signal  
*2: Exposure time is determined by the setting of "7. 2 (1.3) Changing each setting in E.TRG mode".  
*3: Video is output at the falling edge of the internal VD following completion of the exposure period.  
The video and FVAL/LVAL/DVAL have a paired relationship.  
Note:  
When the next trigger is input before completion of the output of the video corresponding to the trig-  
24  
 
ger, there will be an effect on the video.  
Negative polarity mode  
Positive polarity mode  
Trigger*1  
About 1 µs  
Exposure period*2  
Exposure period*2  
3
(Internal VD)  
*
RGB data  
(video interval image)  
FVAL  
LVAL,  
DVAL  
28H (Partial scanning OFF)  
38H (Partial scanning 60fps)  
47H (Partial scanning 90fps)  
(1. 2) 1 Pulse Trigger SYNC-NON RESET Picture Output Timing (at Time of Internal Sync)  
*1: Externally input signal  
*2: Exposure time is determined by the setting of "7. 2 (1.3) Changing each setting in E.TRG mode".  
As long as there is no external sync input, the internal VD will be output when SJ01 is set to HD/VD output  
position.  
*3: Video is output at the falling edge of the internal VD following completion of the exposure period.  
The video and FVAL/LVAL/DVAL have a paired relationship.  
Note:  
When the next trigger is input before completion of the output of the video corresponding to the trig-  
ger, there will be an effect on the video.  
25  
 
( 2 ) 1P SR (1 Pulse Trigger Sync Reset)  
Charge begins to accumulate after the trigger input to CC1 of the DIGITAL terminal, the vertical sync signal is  
reset and frame images are output.  
(2. 1) 1 Pulse Trigger SYNC-RESET Picture Output Timing  
Negative polarity mode  
Trigger*1  
Positive polarity mode  
About 1 µs  
Exposure period*2  
Exposure completion  
0 to 1H*3  
(Internal VD)  
RGB data  
(video interval image)  
FVAL  
LVAL,  
DVAL  
28H (Partial scanning OFF)  
38H (Partial scanning 60fps)  
47H (Partial scanning 90fps)  
*1: Externally input signal  
*2: Exposure time is determined by the setting of "7. 2 (1.3) Changing each setting in E.TRG mode".  
*3: VD is generated after 0 to 1H following the completion of the exposure period and the video is synchro-  
nized to this and output.  
Note:  
When the next trigger is input before completion of the output of the video corresponding to the trig-  
ger, there will be an effect on the video.  
26  
 
( 3 ) PW SNR (Pulse width trigger SYNC-NON RESET)  
The trigger input to CC1 of the DIGITAL terminal develops 1 frame images.  
(3. 1) Pulse Width Trigger SYNC-NON RESET Picture Output Timing  
(At Time of One-shot or Continuous External VD/Continuous External HD Input)  
Negative polarity mode  
Trigger*1  
Positive polarity mode  
About 7 µs  
About 1 µs  
Exposure period*2  
Exposure period*2  
External HD IN*1  
External VD IN*1  
(Internal VD)  
About 1H  
RGB data  
(video interval image)  
FVAL  
LVAL,  
DVAL  
28H (Partial scanning OFF)  
38H (Partial scanning 60fps)  
47H (Partial scanning 90fps)  
The internal VD falling edge is within the  
exposure period and thus video is not output.  
3
*
*1: Externally input signal  
*2: Exposure time = Trigger pulse width + 6 µs  
(Valid trigger pulse width is 2 µs or greater for external trigger shutter operation.)  
*3: Video is output at the falling edge of the internal VD following completion of the exposure period.  
The video and FVAL/LVAL/DVAL have a paired relationship.  
Note:  
When the next trigger is input before completion of the output of the video corresponding to the trig-  
ger, there will be an effect on the video.  
27  
 
(3. 2) Pulse Width Trigger SYNC-NON RESET Picture Output Timing (at Time of Internal Sync)  
Negative polarity mode  
Positive polarity mode  
Trigger*1  
About 7 µs  
About 1 µs  
Exposure period*2  
Exposure period*2  
3
(Internal VD)  
RGB data  
*
(video interval image)  
FVAL  
LVAL,  
DVAL  
28H (Partial scanning OFF)  
38H (Partial scanning 60fps)  
47H (Partial scanning 90fps)  
*1: Externally input signal  
*2: Exposure time = Trigger pulse width + 6 µs  
(Valid trigger pulse width is 2 µs or greater for external trigger shutter operation.)  
*3: As long as there is no external sync input, the internal VD will be output when SJ01 is set to HD/VD output  
position.  
*4: Video is output at the falling edge of the internal VD following completion of the exposure period.  
The video and FVAL/LVAL/DVAL have a paired relationship.  
Note:  
When the next trigger is input before completion of the output of the video corresponding to the trig-  
ger, there will be an effect on the video.  
28  
 
( 4 ) PW SR (Pulse width trigger SYNC-RESET)  
The trigger input to CC1 of the DIGITAL terminal develops 1 frame images.  
(4. 1) 1 Pulse Width Trigger SYNC-RESET Picture Output Timing  
Negative polarity mode  
Positive polarity mode  
Trigger*1  
About 1 µs  
About 7 µs  
Exposure period*2  
Exposure completion  
0 to 1H  
3
(Internal VD)  
*
RGB data  
(video interval image)  
FVAL  
LVAL,  
DVAL  
28H (Partial scanning OFF)  
38H (Partial scanning 60fps)  
47H (Partial scanning 90fps)  
*1: Externally input signal  
*2: Exposure time = Trigger pulse width + 6 µs  
(Valid trigger pulse width is 2 µs or greater for external trigger shutter operation.)  
*3: VD is generated after 0 to 1H following the completion of the exposure period and the video is synchro-  
nized to this and output.  
Note:  
When the next trigger is input before completion of the output of the video corresponding to the trig-  
ger, there will be an effect on the video.  
29  
 
( 5 ) RR (Reset restart)  
Input of an external reset-restart signal (CC4 of the DIGITAL terminal: External VD input) permits one screen  
of information to be output at an arbitrary timing.  
(5. 1) Long Term Exposure  
When a sufficient sensitivity is not obtained with the normal operating conditions or capturing the trail of a  
moving subject is desired, the reset-restart function allows high-sensitivity images by extending the exposure  
time. To achieve this, please input from an external source a VD signal that has an expanded VD pulse and VD  
pulse interval.  
(5. 2) Input Timing Chart Example  
External HD IN  
External VD IN  
V reset  
V reset  
About 1H  
About 1H  
(Internal VD)  
Exposure period  
Exposure period  
Exposure period  
RGB data  
(video interval image)  
FVAL  
LVAL,  
DVAL  
1 frame  
1 frame= 796H (Partial scanning OFF  
)
387H (Partial scanning 60fps)  
258H (Partial scanning 90fps)  
External VD interval: more than 1 frame  
30  
 
7. 6 Partial Scanning  
( 1 ) Partial Scanning OFF (All pixels scanning)  
In this mode, all pixels independent signal from the DIGITAL connector is output with increased flame rate.  
Video interval  
image  
1/29.2s (796H)  
( 2 ) Partial Scanning ON  
In this mode, the pixel signal of the vertical center portion from the DIGITAL connector is output.  
In the E.60fps or E.90fps mode, the partial scanning and the all pixels scanning can be switched by the  
DIGITAL terminal (CC2: partial scanning control signal).  
CC2  
L’  
E.90fps  
E.60fps  
Partial scanning 90fps  
All pixels scanning  
Partial scanning 60fps  
All pixels scanning  
H’  
Video interval  
image  
1/60s (387H): When 60fps is selected  
1/90s (258H): When 90fps is selected  
( 3 ) When Partial Scanning Mode is ON  
(Internal VD)  
FVAL  
LVAL,  
DVAL  
RGB data  
(video interval image)  
Blanking interval  
Video interval Blanking interval  
B
C
D
Total  
A
Video period  
Mode  
60fps  
90fps  
Total A  
387H  
Blanking interval B Video interval C Blanking interval D  
38H  
47H  
322H  
175H  
27H  
36H  
258H  
31  
 
8. INPUT OUTPUT SIGNAL SPECIFICATOINS  
( 2 ) VD Input Specifications  
( 1 ) HD Input Specifications  
5H to 21H  
2.0 µs to 5.0 µs  
( 3 ) Trigger Pulse Specifications  
(Positive polarity mode)  
More than 2 µs  
(Negative polarity mode)  
More than 2 µs  
( 6 ) External HD/VD Input Phase Specifications  
External HD  
rising edge  
100  
100  
External HD  
Unit : Clock  
1 clk=33.9nsec  
Center  
The phase relationship of the external HD and VD should correspond to the center phase (i.e., the external HD falling  
edge) as illustrated in the above diagram.  
External VD falling edge:  
Please input within about 100 clock cycles of the standard center phase.  
Note that V sync of the video is output with a delay of about 1H from the external VD at the time of reset-restart and  
the external trigger mode.  
In the normal mode:  
Continuously with the HD period of 43.05 µs and VD period of 34.27 ms (partial scanning 60fps: 16.67 ms, partial  
scanning 90fps: 11.11 ms ).  
Phase timing is as illustrated in the above diagram (with only the falling edge applicable).  
In the reset-restart/external trigger mode:  
Continuously with the HD period of 43.05 µs. VD (reset) is at an arbitrary timing with the phase of HD being within the  
standard of the above diagram.  
32  
 
9. CCD OUTPUT WAVEFORM TIMING CHART  
( 1 ) Horizontal Output Waveform Timing Chart  
One horizontal scan interval 1270 clk  
(43.05 µs)  
LVAL,  
DVAL  
246 clk  
(8.34µs)  
33.9 ns  
29 clk 3 clk  
40 clk  
164 clk  
CCD  
output signal  
5 clk  
5
clk  
Optical black Horizontal transfer Dummy  
portion  
stop interval  
pixels  
Total effective pixels 1034 clk  
Optical black  
portion  
Horizontal blanking interval 246 clk  
Output video interval 1024 clk  
(8.34 µs)  
(34.71 µs)  
RGB data  
Pixel  
Clock  
CLK=33.9 nsec  
(29.5 MHz)  
( 2 ) Vertical Output Waveform Timing Chart  
796H  
28H  
(1205µs)  
FVAL  
LVAL,  
DVAL  
768H  
CCD  
output signal  
1
1
2
3
4
5
6
7
1
1
2
3
4
5
6
7
Dummy  
pixels  
Dummy  
pixels  
Optical black  
portion  
Optical black  
portion  
Optical black  
portion  
Optical black  
portion  
Vertical blanking interval 28H  
Vertical blanking interval 28H  
(1205µs)  
(1205µs)  
RGB data  
33  
 
10. SPECIFICATIONS  
Power supply  
DC12V 10%  
Power consumption  
Pick-up system  
Approx.4.3W  
RGB, 3CCD  
Image sensor  
1/3inch All pixels CCD  
(Effective pixels)  
(Horizontal : 1034pixels, Vertical : 779pixels)  
Scanning system  
Scan frequency  
Sync system  
Progressive scan  
Horizontal : 23.229kHz, Vertical : 29.18Hz  
Internal/External (Automatic switching)  
768TV lines  
F6.8 standard (2000 lx, 3000K)  
14 lx (F2.2, Sensitivity + 18 dB, 3000K)  
C mount (flange back : 17.526 mm in-air)  
32 to 104°F (0 to 40°C)  
Horizontal resolution  
Sensitivity  
Minimum illumination  
Lens mount  
Ambient temperature  
Ambient humidity  
Weight  
Less than 90%  
Approx. 5.82oz (165g)  
External dimension  
1.73(W) x 1.73(H) x 3.07(D)  
(44 (W) x 44 (H) x 78 (D) mm)  
(except for protruded portion)  
White balance  
Gain  
AWB (Automatic white balance), MANUAL (Manual)  
MANUAL (Manual), OFF (0 dB)  
Output signal  
Sync signal output  
8-bit RGB, Digital output (Camera Link format)  
FVAL, LVAL, DVAL (Positive polarity)  
Pixel Clock (29.5MHz)  
External sync input  
Interface  
HD or VD : Negative  
Serial data interface: Ser TC (RXD), Ser TFG (TXD)  
EXC-CL05S (Cable), etc  
Optional parts  
The designs and specifications are subject to change without notice.  
34  
 
11. EXTERNAL APPEARANCE DIAGRAM  
Unit : mm [inch]  
5
[0.20]  
12  
[0.47]  
2-M3 Depth 3  
6.3  
[0.25]  
44  
[1.73]  
78  
[3.07]  
(AWB)  
DISP  
DATA  
MENU  
DC IN 12V  
PAGE  
4.8  
[0.19]  
5
56  
[2.20]  
2-M2  
[0.20]  
4-M3 Depth 3  
19.2  
[0.76]  
4-M2 Depth 3  
25  
[0.98]  
25  
[0.98]  
inch=mm/25.4  
12. BEFORE MAKING A SERVICE CALL  
Symptom  
Items to be checked  
No image  
Is the power supplied correctly?  
Is the lens iris adjusted correctly?  
Are the cables connected correctly?  
Is the shutter mode set correctly?  
Is the image process equipment set correctly?  
Poor color  
Is the monitor adjusted correctly?  
Is the white balance of the camera adjusted correctly?  
Is the illumination dark?  
35  
 
LIMITED WARRANTY  
TOSHIBA CCD CAMERA  
uct you will be eligible for periodic updates, announcements, and special offers.You will have access to extended  
warranty options, upgrades (as applicable), useful tips, on-line troubleshooting, and the ability to schedule service  
on-line if necessary. The Imaging Systems Division of Toshiba America Information Systems, Inc. ("ISD") makes  
the following limited warranties. These limited warranties extend to the Original End-User ("Your[r]").  
Limited One (1) Year Warranty of Labor and Parts  
ISD warrants this product and parts against defects in material or workmanship for a period of one year from the  
date of original retail purchase by the end-user. During this period, ISD will repair or replace a defective product or  
part with a new or refurbished item. The user must deliver the entire product to an ISD authorized service center.  
The user is responsible for all transportation and insurance charges for the product to the Service Center. ISD  
reserves the right to substitute Factory Refurbished Parts and / or Factory Refurbished Product in place of those  
in need of repair.  
Step-by-step Procedures - How to Obtain Warranty Service  
[1] Verify operation of the unit by checking the instruction manual  
[2] If there is a defect in material or workmanship, contact an Authorized Service Provider within 30 days after the  
product fails to comply with specifications.  
[3] Arrange for delivery of the product to the ISD authorized service center. Products must be insured and securely  
packed, preferably in the original shipping carton. A letter explaining the defect and a copy of the bill of sale or  
other proof of purchase must be enclosed with a complete return street address and daytime telephone number.  
Charges for transportation and insurance must be prepaid by the end-user.  
Questions? If you have any questions, please check the Toshiba Imaging Systems Division Web site as  
follows:  
Website:  
Your Responsibility, warranties are subject to the following conditions:  
[1] You must retain the bill of sale or provide other proof of purchase.  
[2] You must schedule service within thirty days after you discover a defective product or part.  
[3] All warranty servicing of this product must be made by a Toshiba ISD Authorized Service Provider.  
[4] The warranty extends to defects in material or workmanship as limited above, and not to any products or parts  
that have been lost or discarded by user. The warranty does not cover damage caused by misuse, accident,  
improper installation, improper maintenance, or use in violation of instructions furnished by ISD. The warranty  
does not extend to units which have been altered or modified without authorization of ISD, or to damage to prod-  
ucts or parts thereof which have had the serial number removed, altered defaced or rendered illegible.  
ALL WARRANTIES IMPLIED BY STATE LAW, INCLUDING THE IMPLIED WARRANTIES OF MERCHANT-  
ABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY LIMITED TO THE DURATION OF  
THE LIMITED WARRANTIES SET FORTH ABOVE. Some states do not allow limitations on how long an  
implied warranty lasts, so the above limitation may not apply. WITH THE EXCEPTION OF ANY WARRAN-  
TIES IMPLIED BY STATE LAW AS HEREBY LIMITED, THE FOREGOING EXPRESS WARRANTY IS EXCLU-  
SIVE AND IN LIEU OF ALL OTHER WITH RESPECT TO THE REPAIR OR REPLACEMENT OF ANY PROD-  
UCTS OR PARTS. IN NO EVENT SHALL ISD BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAM-  
AGES. Some states do not allow the exclusion or limitation of incidental or consequential damages so the  
above limitation may not apply.  
No person, agent, distributor, dealer, service station or company is authorized to change, modify or ex-  
tend the terms of these warranties in any manner whatsoever. The time within which an action must be  
commenced to enforce any obligation of ISD arising under this warranty or under any statute, or law of the  
United States or any state thereof, is hereby limited to one year from the date you discover or should have  
discovered, the defect. This limitation does not apply to implied warranties arising under state law. Some  
states do not permit limitation of the time within which you may bring an action beyond the limits provided  
by state law so the above provision may not apply to user. This warranty gives the user specific legal  
rights, and user may also have other rights, which may vary from state to state.  
TOSHIBA AMERICA INFORMATION SYSTEMS, INC.  
Imaging Systems Division  
Copyright © 2002 Toshiba America, Inc. All rights reserved.  
 

TDK Network Card DEA Series DEA205375BT 2054A1 User Manual
Toastmaster Can Opener 2249IB User Manual
Toastmaster Toaster T2055BC User Manual
Tripp Lite Network Card N490 016 STST User Manual
Uniden Cordless Telephone DECT2180 Series User Manual
ViewSonic Projector PJ552 User Manual
Vox Stereo Amplifier AC30CC1 User Manual
Vulcan Hart Fryer 1ER50C User Manual
Weber Gas Grill 500 LP User Manual
Weed Eater Lawn Mower 545186749 User Manual