INSTRUCTION MANUAL
3 CCD CAMERA
IK-TF7C
For Customer Use
Enter below the Serial No.
which is located on the
bottom of the cabinet. Retain
this information for future ref-
erence.
Model No.: IK-TF7C
Serial No.:
FCC NOTICE
This equipment has been tested and found to comply with the limits for a Class A digital device, pursu-
ant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance
with the instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
USER-INSTALLER CAUTION:Your authority to operate this FCC verified equipment could be voided if
you make changes or modifications not expressly approved by the party responsible for compliance to
Part 15 of the FCC Rules.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est comforme à la norme NMB-003 du Canada.
Following information is only for EU-member states:
The use of the symbol indicates that this product may not be treated as household waste.
By ensuring this product is disposed of correctly, you will help prevent potential negative
consequences for the environment and human health, which could otherwise be caused by
inappropriate waste handling of this product. For more detailed information about the take-
back and recycling of this product, please contact your supplier where you purchased the
product or consult.
Note the following instructions when installing.
• Do not cover the product by any material.
• Do not put the product on an Inflammable material such as carpet or blanket.
• Do not put the product in a narrow space, since the heat generated from the
product may be difficult to emanate.
If you do not follow the above, the heat generated by the product may cause fire.
Do not put the product in direct sunshine and/or high temperature.
The temperature inside the product may cause fire.
Avoid setting in humid, smoky, vaporized or dusty places.
This may cause fire and/or electric shock.
Do not point the lens directly at the sun and/or intensive light such as di-
rect sunlight, etc.
Focusing of the light may cause injury of eye and/or fire.
Ask your dealer to perform a periodical check and internal cleaning (approx.
once every five years).
Dust inside the product may cause fire and/or trouble. For check and cleaning
cost, please consult your dealer.
Disclaimer
We disclaim any responsibility and shall be held harmless for any damages or losses incurred by the
user in any of the following cases:
1. Fire, earthquake or any other act of God; acts by third parties; misuse by the user, whether inten-
tional or accidental; use under extreme operating conditions.
2. Malfunction or non-function resulting in indirect, additional or consequential damages, including
but not limited to loss of expected income and suspension of business activities.
3. Incorrect use not in compliance with instructions in this instruction manual.
4. Malfunctions resulting from misconnection to other equipment.
5. Repairs or modifications made by the user or caused to be made by the user and carried out by
an unauthorized third party.
6. Notwithstanding the foregoing, Toshiba’s liabilities shall not, in any circumstances, exceed the
purchase price of the product.
Copyright and Right of Portrait
There may be a conflict with the Copyright Law and other laws when a customer uses, displays,
distributes, or exhibits an image picked up by the camera without permission from the copyright
holder. Please also note that transfer of an image or file covered by copyright is restricted to use
within the scope permitted by the Copyright Law.
3
TABLE OF CONTENTS
1. CAUTIONS ON USE AND INSTALLATION ..... 5 7. 3 External Sync ............................................ 22
( 1 ) External sync signal input conditions ...... 22
( 2 ) External sync frequency range ............... 22
( 3 ) Using the unit with external sync signal .. 23
(3. 1) H (horizontal) phase adjustment ...... 23
2. COMPONENTS ................................................ 5
3. ITEMS CONTROLLED BY USING
ON SCREEN DISPLAY .................................... 6
( 4 ) Changing HD/VD input/output ................ 23
4. NAMES AND FUNCTIONS .............................. 7
5. CONNECTION .................................................. 8
7. 4 Synchro. Scan Operation ......................... 23
( 1 ) Setting by 1H .......................................... 23
( 2 ) Setting by the frame ................................ 23
5. 1 Standard Connection ................................ 8
5. 2 Cautions on Connection ........................... 8
5. 3 Connector Pin Assignments ..................... 8
7. 5 EXT TRIG (External trigger) ..................... 24
( 1 ) 1P SNR (1 Pulse Sync Non Reset) ........ 24
(1. 1) 1 Pulse Trigger SYNC-NON RESET
Picture Output Timing ...................... 24
(1. 2) 1 Pulse Trigger SYNC-NON RESET
Picture Output Timing (at Time of
6. OPERATION ..................................................... 9
6. 1 White Balance........................................... 9
6. 2 Gain ........................................................ 10
6. 3 Shading Correction ................................. 10
Internal Sync) ................................... 25
7. MODE SETTING BY ON SCREEN DISPLAY ..... 11
( 2 ) 1P SR (1 Pulse Sync Reset)................... 26
(2. 1) 1 Pulse Trigger SYNC-RESET Picture
Output Timing ................................... 26
7. 1 Using the Menus ..................................... 11
7. 2 Menus ..................................................... 12
( 1 ) SHUTTER (Electronic shutter)................ 12
(1. 1) Changing each setting in
( 3 ) PW SNR (Pulse width trigger
SYNC-NON RESET) .............................. 27
(3. 1) Pulse Width Trigger SYNC-NON RESET
Picture Output Timing ...................... 27
(3. 2) Pulse Width Trigger SYNC-NON RESET
Picture Output Timing (at Time of
MANU mode ..................................... 12
(1. 2) Changing each setting in
SS (synchro. scan) mode ................. 13
(1. 3) Changing each setting in
E.TRG mode..................................... 14
(1. 3. 1) Changing each setting in
1P SNR mode ............................... 14
(1. 3. 2) Changing each setting in
1P SR mode ................................. 15
(1. 3. 3) Changing each setting in
PW SNR mode ............................. 16
(1. 3. 4) Changing each setting in
PW SR mode ................................ 17
(1. 3. 5) Changing each setting in
RR mode ....................................... 18
Internal Sync) ................................... 28
( 4 ) PW SR (Pulse width trigger
SYNC-RESET) ....................................... 29
(4. 1) 1 Pulse Width Trigger SYNC-RESET
Picture Output Timing ...................... 29
( 5 ) RR (Reset restart) .................................. 30
(5. 1) Long Term Exposure ........................ 30
(5. 2) Input Timing Chart Example ............ 30
7. 6 Partial Scanning ........................................ 31
( 1 ) Partial Scanning OFF
( 2 ) GAIN (Video gain)................................... 18
(2. 1) Changing each setting in GAIN........ 18
( 3 ) WHT BAL (White balance)...................... 19
(3. 1) Changing each setting in AWB
(All pixels scanning) ................................ 31
( 2 ) Partial Scanning ON ............................... 31
( 3 ) When Partial Scanning Mode is ON ....... 31
8. INPUT OUTPUT SIGNAL SPECIFICATOINS ........ 32
(Automatic White Balance) mode .... 19
(3. 2) Changing each setting in MANU
(Manual) mode ................................. 19
( 1 ) HD/VD Output Amplitude Specifications ... 32
( 2 ) VD Input Specifications........................... 32
( 3 ) VIDEO INDEX Output Specifications..... 32
( 4 ) HD Input Specifications .......................... 32
( 5 ) Trigger Pulse Specifications.................... 32
( 4 ) PROCESS .............................................. 20
(4. 1) Changing master pedestal ............... 20
(4. 2) Changing R pedestal ........................ 20
(4. 3) Changing B pedestal ........................ 20
(4. 4) Changing the shading correction mode ... 20
(4. 5) Changing the manual shading correction setting ... 20
( 6 ) External HD/VD Input Phase
Specifications.......................................... 32
( 5 ) SYNC ...................................................... 21
(5. 1) Adjusting horizontal phase ............... 21
( 6 ) OPTION .................................................. 21
(6. 1) Changing serial communication baud
rate .................................................... 21
9. CCD OUTPUT WAVEFORM TIMING CHART ... 33
( 1 ) Horizontal Output Waveform Timing Chart ... 33
( 2 ) Vertical Output Waveform Timing Chart... 33
10. SPECIFICATIONS ....................................... 34
11. EXTERNAL APPEARANCE DIAGRAM ...... 35
12. BEFORE MAKING A SERVICE CALL ........ 35
( 7 ) Setting to factory setting status............... 22
4
1. CAUTIONS ON USE AND INSTALLATION
Carefully handle the units.
Handling of the protection cap.
•
•
•
Do not drop, or give a strong shock or vibration to
the camera. This may cause problems. Treat the
camera cables carefully to prevent cable problems,
such as cable breakdown and loosened connec-
tions.
Keep the protection cap away from children. Chil-
dren may put them into mouth or swallow them
accidentally. The protection cap protects the im-
age sensing plane when the lens is removed from
the camera, do not throw away.
Do not shoot intense light.
When not using the camera for a longtime.
Stop supplying power.
•
•
If there is an intense light at a location on the
screen such as a spot light, a blooming and smear-
ing may occur. When intense light enters, vertical
stripes may appear on the screen. This is not a
malfunction. Ghosts may occur when there is an
intense light near the object. In this case, change
the shooting angle.
When cleaning the camera.
Unplug the power source before cleaning. Clean
with a soft dry cloth only. Do not use benzine, al-
cohol, thinner, household detergents, chemically
treated cloths, etc. If used, coating and printed
letters may be discolored.When cleaning the lens,
use a lens cleaning paper, etc.
Install the camera in a location free from noise.
•
If the camera or the cables are located near power
utility lines or a TV, etc. undesirable noise may ap-
pear on the screen. In such a case, try to change
the location of the camera or the cable wiring.
Avoid using or storing the camera in the fol-
lowing places:
•
Places filled with highly flammable gas.
Places near gasoline, benzene, or paint thinner.
Places subject to strong vibration.
Moire
•
•
When thin stripe patterns are shot, stripe patterns
that are not actually there (moire) may appears
as interference stripes. This is not a malfunction.
Places contacting chemicals (such as pesticides),
rubber or vinyl products for a long period of time.
Operating ambient temperature and humidity.
Do not use the camera in places where tempera-
ture and humidity exceed the specifications. Pic-
ture quality will lower and internal parts may be
damaged.
Be particularly careful when using in places ex-
posed to direct sunlight. When shooting in hot
places, depending on the conditions of the object
and the camera (for example when the gain is in-
creased), noise in the form of vertical strips or
white dots may occur. This is not a malfunction.
2. COMPONENTS
(1) Camera ...........................................................................................................................................1
(2) Accessories
(a) Instruction manual ...................................................................................................................1
5
3. ITEMS CONTROLLED BY USING ON SCREEN DISPLAY
Preset value
(Factory setting)
Item
MODE
E. TRG
MANU speed
Available selections
MANU, SS, E. TRG
1P SNR, 1P SR, PW SNR, PW SR, RR
OFF, 1/100s, 1/250s, 1/500s, 1/1000s, 1/2000s,
MANU
1P SNR
OFF
1/4000s, 1/10000s, 1/25000s, 1/50000s, 1/1000000s
Syncro. Partial scanning OFF 1H/796H~795H/796H, OFF, 2FRM~512FRM
scan. Partial scanning 60fps 1H/387H~386H/387H, OFF, 2FRM~512FRM
OFF
OFF
Partial scanning 90fps
1H/258H~257H/258H, OFF, 2FRM~512FRM
OFF, 60 fps, 90 fps, E.60 fps, E.90 fps
Partial scanning
Trigger
(1P SNR/SR)
Trigger
(PW SNR/SR)
,
,
1P
16 ms
0.01ms~16ms
exposure time
MODE
MANU
MODE
Color temperature
MANUAL R GAIN
MANUAL B GAIN
Master pedestal
R pedestal
MANU, OFF
-3dB~18dB
AWB, MANU
3200K, 5600K
-100~0~100
-100~0~100
-64~0~64
OFF
0dB
AWB
3200K
0
0
0
0
0
-64~0~64
-64~0~64
B pedestal
Shading correction
mode
MANU, OFF
MANU
Manual shading
correction
H phase adjustment
-128~0~127
-100~0~100
0
0
Baud rate
9600 bps, 19200 bps
9600 bps
6
4. NAMES AND FUNCTIONS
8
2
4
DC IN 12V terminal
DISP button
1 Prism faceplate
MENU UP button
(AWB)
DISP
6
7
DATA UP (AWB) button
DATA DOWN button
MENU DATA
DC IN 12V
PAGE
5 MENU DOWN button
9
DIGITAL terminal
3 PAGE button
[ Front ]
[ Rear ]
Prism faceplate
The protection cap is attached on the lens mount portion. After removing the cap,
mount the lens. Be careful not to scratch or touch the optical area.
1
DISP button
Used when switching the display.
2
3
4
5
6
PAGE button
Used when switching to the menu and when selecting the menus.
Select the function to be confirmed or changed on the menu.
Select the function to be confirmed or changed on the menu.
MENU UP button
MENU DOWN button
DATA UP (AWB) button
Changes the value of the function selected by the MENU (UP/DOWN) button.
(Also used when using AWB.)
DATA DOWN button
DC IN 12V terminal
RGB terminal
Changes the value of the function selected by the MENU (UP/DOWN) button.
Accept a DC power input (12V).
7
8
9
8-bit RGB, digital signal, and sync signal are output in the Camera Link format.
Trigger signal and external sync signal (HD,VD) are input.
Mode switching signal for partial scanning is input.
Accepts serial communication control signal.
7
5. CONNECTION
5. 1 Standard Connection
Lens
Cable (not included)
DC IN 12V
IK-TF7C
Frame grabber board,
Monitor
Less than 4 mm
image process
equipment etc.
DC power
supply
5. 2 Cautions on Connection
• When connecting the camera cables, unplug the power source of the camera and the other equipment
connected.
• We suggest using a C mount lens made for a 3CCD camera.
When using another lens, the best camera performance of this camera may not be obtained.
(For example, low resolution may occur, focus may be lost through the range of a zoom lens, and
flare, ghost or shading may occur)
Furthermore, in order to avoid damaging the mounting portion of the camera head, use a lens which
has projection dimension from the mounting base of less than 0.157"(4mm).
• For DC power supply connecting to DC IN 12V terminal, use UL listed and/or CSA approved ungrounding
type AC adaptor with the specifications described below.
Power supply voltage
Current rating
Ripple voltage
Connector
: DC12V 10%
: More than 830 mA
: Less than 50 mV(p–p)
: HR10A–7P–4S by HIROSE electronics Co. Ltd
Pins 1, 2 : 12V
Pins 3, 4 : GND
5. 3 Connector Pin Assignments
Function
I/O
–
O
O
O
O
O
I
DC IN 12V
DIGITAL
1
2
3
4
5
6
7
8
9
GND
14
15
16
17
18
19
20
21
22
23
24
25
26
GND
X0+
1
2
3
4
+12V
+12V
GND
GND
X0-
X1-
X1+
13
26
1
X2-
X2+
Xcllk-
X3-
Xcllk+
X3+
14
SerTC+
SerTC-
Serial communication control (RXD)
Serial communication control (TXD)
Trigger pulse input
1
2
3
4
O
I
SerTFC-
CC1-
SerTFC+
CC1+
CC2-
Connector used:
12226-51000-00
10 CC2+
CC3-
12 CC4+
GND
Partial scanning control
External HD input
I
(3M) or equivalent.
CC3+
CC4-
11
I
Connector used:
I
External VD input
HR10A-7P-4PB
GND
13
–
(HIROSE electronics
Co. Ltd) or equivalent.
8
6. OPERATION
Refer to the item " 5. CONNECTION", connect each equipment correctly.
Turn on the connected equipment and the power source of the camera.
1
2
3
4
5
Point the lens at the object, operate the lens iris adjustment, focus adjustment, etc..
Refer to the item "6.1 White Balance", operate the adjustment.
Refer to the items "6.2 Gain, 7. MODE SETTING BY ON SCREEN DISPLAY", select the necessary items.
6. 1 White Balance
For the white balance adjustment for this unit, AWB (Automatic White Balance) and MANU (Manual white
balance) adjustments are provided. To select the desired mode, refer to the items “7.2 (3) WHT BAL (White
balance)” and “7. MODE SETTING BY ON SCREEN DISPLAY”.
AWB
MANU
(Automatic White Balance)
(Manual White Balance)
Outline
Note
Adjust white balance by shooting the white Adjust the white balance manually using
object inside the area set by AWB menu
and pressing the [DATA UP] button.
the WHT BAL menu while shooting the
white object.
When the shutter mode is E.TRG, AWB is Adjustment is performed by confirming
not available. with a monitor etc.
AWB (Automatic white balance)
1
• Set the MODE to AWB on the WHT BAL menu.
Perform the C.TEMP (color temperature conversion) setting, if necessary.
(Refer to the item "7.2 (3) WHT BAL (White balance)".)
3200K : Appropriate for indoor shooting.
5600K : Appropriate for outdoor shooting.
• If the index menu/menu is displayed, press the [DISP] button to disable the character display on the
menu.
• Shoot a known white object that fills the screen and push [DATA UP] button for approx. 1 second.
• The character AWB blinks on the screen when the AWB starts.
• The character AWB stops blinking when the AWB finishes, and the result is displayed for approx. 1
second.
Result displayed
Meaning
AWB OK
Automatic white balance adjustment finished correctly.
AWB NG LEVEL
LOW
Automatic white balance adjustment cannot be performed because the
video level is too low.
Get the video level propely.
AWB NG
LEVEL HIGH
Automatic white balance adjustment cannot be performed because the
video level is too high.
Get the video level propely.
AWB NG
C. TEMP HIGH
Automatic white balance adjustment cannot be performed because the
color temperature is too low.
If the C.TEMP is set to 5600K, set to 3200K.
If the message appears with the C.TEMP set to 3200K, change the
illumination or use a color temperature conversion filter.
AWB NG
C. TEMP HIGH
Automatic white balance adjustment cannot be performed because the
color temperature is too high.
If the C.TEMP is set to 3200K, set to 5600K.
If the message appears with the C.TEMP set to 5600K, change the
illumination or use the color temperature conversion filter.
9
Result displayed
Meaning
AWB NG
NOT AVAILABLE
Automatic white balance adjustment cannot be performed because the
shutter speed mode is E.TRG mode.
AWB NG
Automatic white balance adjustment cannot be performed for other
reasons. Such as no white area is included in an object, etc.
MANU (Manual white balance)
2
• Set the MODE to MANU on the WHT BAL menu.
(Refer to the item "7.2 (3) WHT BAL (white balance)".)
• Shoot a known white object, adjust the white balance adjusting the levels of R GAIN and B GAIN on the
menu, confirming with a monitor or a monitor etc.
(Refer to the item "7.2 (3) (3.2) Changing each setting in MANU mode".)
6. 2 Gain
When the image is dark even if the lens iris is open, change the gain (video gain) to get the proper video level.
For the gain adjustment of the unit, MANU (Manual) and OFF (0 dB) modes are provided. Select the mode on
the GAIN menu. (Refer to the item "7.2 (2) GAIN (Video gain)".)
MANU (Manual gain)
1
2
Gain adjustment is performed on the GAIN menu. The adjustment range is from -3dB to 18dB in 1dB steps.
(Refer to the item "7.2 (2) (2.1) (a) Changing the gain in MANU mode".)
OFF
Gain is fixed at 0 dB.
6. 3 Shading Correction
Due to the lens used or the environmental condition, vertical color shading may occur at the top and bottom of
the screen. In this case, the shading correction can decrease the color shading. For the shading correction of
the unit, MANU (Manual shading correction) and OFF (no shading correction) modes are provided. Select the
mode on the PROCESS menu. (Refer to the item "7.2 (4) (4.4) Changing the shading correction mode".)
MANU (Manual Shading)
1
Adjust the correction amount on the PROCESS menu by confirming with a monitor or a waveform monitor.
(Refer to the "7.2 (4) (4.5) Changing the manual shading correction setting".)
OFF
2
The status is no shading correction.
* The shading correction is effective when the lens iris or zoom ratio is fixed. Use the unit with SHAD.
OFF for variable lens conditions.
10
7. MODE SETTING BY ON SCREEN DISPLAY
Various settings can be controlled on the unit by using the on screen menu displayed on the monitor. The
contents once set are memorized even if the power source is turned off, so it is unnecessary to set again when
using the unit next time. When the setting is performed, select the menu of the item to be set.
7. 1 Using the Menus
When the power is turned on, the normal screen showing only the shooting image appears. Change the output
to each screen (video signal output, Index menu, and menus) by using the [DISP], [PAGE], [MENU UP], and
[MENU DOWN] buttons.
* A menu is selected when pushing the [PAGE] button after moving the "→" on the screen by the [MENU UP],
[MENU DOWN] button while the Index menu is displayed.
POWER ON
Video signal output
Index menu
DISP
DISP
DISP
PAGE
PAGE
Menus
PAGE
WHT BAL
SHUTTER
GAIN
PROCESS
SYNC
INT
OPTION
SHAD.
MANU
BAUD
RATE
PAGE
PAGE
MANU
PAGE
AWB
PAGE
MANU
SS
PAGE
SHAD.
OFF
EXT
MANU
OFF
E. TRG
1P SR
E. TRG
1P SNR
E. TRG
PW SR
E. TRG
PW SNR
E. TRG
RR
11
7. 2 Menus
• Select the menu to change the setting by referring the item "7.1 Using the Menus".)
• When the [MENU UP], [MENU DOWN] buttons are pushed, the "→" on the screen moves up and down.
Move the "→" to the item to change.
Note:
When performing the mode setting in the menu display while selecting ON in "PART" and E.TRG in
"MODE", the display shows normal mode and then the camera returns the setting mode.
( 1 ) SHUTTER (Electronic shutter)
The electronic shutter has three modes; MANU (Manual), SS (Synchro. Scan), E.TRG (External trigger).
Set the "→" to "MODE" and push [DATA UP], [DATA DOWN] button to select the desired mode among "MANU",
"SS", "E.TRG".
(1. 1) Changing each setting in MANU mode
Move up down
Set by pushing
By pushing
MENU UP, DOWN
DATA UP, DOWN
• Shutter mode MANU, SS, E.TRG
-- SHUTTER --
• Shutter speed setting
OFF, 100 (1/100s), 250 (1/250s), 500 (1/500s)
1000 (1/1000s), 2000 (1/2000s), 4000 (1/4000s)
10000 (1/10000s), 25000 (1/25000s)
MODE
MANU
PART
MANU
50000
OFF
50000 (1/50000s)100000 (1/100000s)
• Partial scanning switch
OFF/60fps/90fps/E.60fps/E.90fps
<MODE = MANUAL>
(a) Changing the shutter speed
Set the "→" to MANU by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Set the shutter speed by pushing [DATA UP], [DATA DOWN] buttons.
(b) Partial scanning setting
Set the "→" to PART by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Select either OFF/60fps/90fps/E.60fps/E.90fps by pushing [DATA UP], [DATA DOWN] buttons.
12
(1. 2) Changing each setting in SS (synchro. scan) mode
Move up down
Set by pushing
By pushing
MENU UP, DOWN
DATA UP, DOWN
• Shutter mode MANU, SS, E.TRG
• Synchro. scanning setting
-- SHUTTER --
OFF : 1H/796H↔795H/796H↔OFF↔2FRM↔512FRM
60fps, E.60fps : 1H/387H↔386H/387H↔OFF↔2FRM↔512FRM
90fps, E.90fps : 1H/258H↔257H/258H↔OFF↔2FRM↔512FRM
MODE
SS
PART
SS
OFF
OFF
• Partial scanning switch
OFF/60fps/90fps/E.60fps/E.90fps
<MODE = SS>
(a) Changing the shutter speed setting
Set the "→" to SS by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Select the shutter speed by pushing [DATA UP], [DATA DOWN] buttons.
(b) Partial scanning setting
Set the "→" to PART by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Select either OFF/60fps/90fps/E.60fps/E.90fps by pushing [DATA UP], [DATA DOWN] buttons.
Note:
The slow shutter speed may increase the fixed pattern noise and/or the white pixels. This is a charac-
teristic of CCD, and is not a symptom of malfunction.
13
(1. 3) Changing each setting in E.TRG mode
The E.TRG has five modes; 1P SNR, 1P SR, PW SNR, PW SR, RR.
First set the "→" to MODE and select E. TRG, then set the "→" to E.TRG and select the desired E.TRG mode.
(1. 3. 1) Changing each setting in 1P SNR mode
Move up down
Set by pushing
By pushing
MENU UP, DOWN
DATA UP, DOWN
• Shutter mode MANU, SS, E.TRG
-- SHUTTER --
• E.TRG mode
1P SNR, 1P SR, PW SNR, PW SR, RR
MODE
E.TRG
TRG.P
EXP.
E.TRG
1P SNR
• Input trigger pulse setting at 1P SNR and 1P SR
Input trigger pulse : positive polarity
Input trigger pulse : negative polarity
16ms
OFF
PART
• Exposure time setting at 1P SNR and 1P SR
0.01 ms
0.02 ms
0.02 ms
step
0.4 ms
0.1 ms
step
1 ms
16 ms
1 ms
step
0.01 ms
step
• Partial scanning switch
OFF/60fps/90fps/E.60fps/E.90fps
<MODE = E.TRG E.TRG = 1P SNR>
(a) Changing the polarity of inputting trigger pulse setting
Set the "→" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Select either
,
by pushing [DATA UP], [DATA DOWN] buttons.
(b) Changing 1P SNR exposure time setting
Set the "→" to EXP. by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Set the exposure time by pushing [DATA UP], [DATA DOWN] buttons.
Note:
The longer the storage time with extended exposures, the more visible certain characteristics of CCD
cameras become: fixed pattern noise, white pixels, etc.
(c) Changing the partial scanning setting
Set the "→" to PART by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Select either OFF/60fps/90fps/E.60fps/E.90fps by pushing [DATA UP], [DATA DOWN] buttons.
14
(1. 3. 2) Changing each setting in 1P SR mode
Move up down
Set by pushing
By pushing
MENU UP, DOWN
DATA UP, DOWN
• Shutter mode MANU, SS, E.TRG
-- SHUTTER --
• E.TRG mode
1P SNR, 1P SR, PW SNR, PW SR, RR
MODE
E.TRG
TRG.P
EXP.
PART
E.TRG
1P SR
• Input trigger pulse setting at 1P SNR and 1P SR
Input trigger pulse : positive polarity
Input trigger pulse : negative polarity
16ms
OFF
• Exposure time setting at 1P SNR and 1P SR
0.01 ms
0.02 ms
0.02 ms
step
0.4 ms
0.1 ms
step
1 ms
16 ms
1 ms
step
0.01 ms
step
• Partial scanning switch
OFF/60fps/90fps/E.60fps/E.90fps
<MODE = E.TRG E.TRG = 1P SR>
(a) Changing the polarity of inputting trigger pulse setting
Set the "→" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Select either
,
by pushing [DATA UP], [DATA DOWN] buttons.
(b) Changing 1P SR exposure time setting
Set the "→" to EXP. by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Set the exposure time by pushing [DATA UP], [DATA DOWN] buttons.
Note:
The longer the storage time with extended exposures, the more visible certain characteristics of CCD
cameras become: fixed pattern noise, white pixels, etc.
(c) Changing the partial scanning setting
Set the "→" to PART by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Select either OFF/60fps/90fps/E.60fps/E.90fps by pushing [DATA UP], [DATA DOWN] buttons.
15
(1. 3. 3) Changing each setting in PW SNR mode
Move up down
Set by pushing
By pushing
MENU UP, DOWN
DATA UP, DOWN
• Shutter mode MANU, SS, E.TRG
-- SHUTTER --
• E.TRG mode
MODE
E.TRG
PW SNR
1P SNR, 1P SR, PW SNR, PW SR, RR
E.TRG
TRG.P
PART
• Input trigger pulse setting at PW SNR and PW SR
Input trigger pulse : positive polarity
OFF
Input trigger pulse : negative polarity
• Partial scanning switch
OFF/60fps/90fps/E.60fps/E.90fps
<MODE = E.TRG E.TRG = PW SNR>
(a) Changing the polarity of inputting trigger pulse setting
Set the "→" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Select either
,
by pushing [DATA UP], [DATA DOWN] buttons.
(b) Changing the partial scanning setting
Set the "→" to PART by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Select either OFF/60fps/90fps/E.60fps/E.90fps by pushing [DATA UP], [DATA DOWN] buttons.
Note:
The longer the storage time with extended exposures, the more visible certain characteristics of CCD
cameras become: fixed pattern noise, white pixels, etc.
16
(1. 3. 4) Changing each setting in PW SR mode
Move up down
Set by pushing
By pushing
MENU UP, DOWN
DATA UP, DOWN
• Shutter mode MANU, SS, E.TRG
-- SHUTTER --
• E.TRG mode
MODE
E.TRG
PW SR
1P SNR, 1P SR, PW SNR, PW SR, RR
E.TRG
TRG.P
PART
• Input trigger pulse setting at PW SNR and PW SR
OFF
Input trigger pulse : positive polarity
Input trigger pulse : negative polarity
• Partial scanning switch
OFF/60fps/90fps/E.60fps/E.90fps
<MODE = E.TRG E.TRG = PW SR>
(a) Changing the polarity of inputting trigger pulse setting
Set the "→" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Select either
,
by pushing [DATA UP], [DATA DOWN] buttons.
Note:
The longer the storage time with extended exposures, the more visible certain characteristics of CCD
cameras become: fixed pattern noise, white pixels, etc.
17
(1. 3. 5) Changing each setting in RR mode
Move up down
Set by pushing
By pushing
MENU UP, DOWN
DATA UP, DOWN
• Shutter mode MANU, SS, E.TRG
-- SHUTTER --
• E.TRG mode
MODE
E.TRG
PART
E.TRG
RR
OFF
1P SNR, 1P SR, PW SNR, PW SR, RR
• Partial scanning switch
OFF/60fps/90fps/E.60fps/E.90fps
<MODE = E.TRG E.TRG = RR>
(a) Changing the partial scanning setting
Set the "→" to PART by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Select either OFF/60fps/90fps/E.60fps/E.90fps by pushing [DATA UP], [DATA DOWN] buttons.
Note:
The longer the storage time with extended exposures, the more visible certain characteristics of CCD
cameras become: fixed pattern noise, white pixels, etc.
( 2 ) GAIN (Video gain)
GAIN has two modes; MANU, OFF.
Set the "→" to MODE, push the [DATA UP], [DATA DOWN], and select mode among MANU, OFF. In the OFF
mode, gain is fixed to 0dB.
(2. 1) Changing each setting in GAIN
Move up down
Set by pushing
By pushing
MENU UP, DOWN
DATA UP, DOWN
-- GAIN --
MODE
MANU
MANU
0dB
• Gain mode MANU, OFF
• Manual gain -3 dB to 18 dB (10 dB step)
(a) Changing the gain in MANU mode
Set the "→" to MANU by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Set the manual gain by pushing [DATA UP], [DATA DOWN] buttons.
18
( 3 ) WHT BAL (White balance)
WHT BAL has two modes; AWB, MANU.
Set the "→" to MODE, push the [DATA UP], [DATA DOWN], and select mode among AWB, MANU.
(3. 1) Changing each setting in AWB (Automatic White Balance) mode
Move up down
Set by pushing
By pushing
MENU UP, DOWN
DATA UP, DOWN
-- WHT BAL --
MODE
AWB
• White balance mode setting (AWB, MANU)
C.TEMP
3200
• Color temperature setting 3200, 5600
(a) Changing color temperature setting
Set the "→" to C.TEMP by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Select either 3200 or 5600 by pushing [DATA UP], [DATA DOWN] buttons.
(3. 2) Changing each setting in MANU (Manual) mode
Move up down
Set by pushing
By pushing
MENU UP, DOWN
DATA UP, DOWN
-- WHT BAL --
MODE
MANU
• White balance mode AWB, MANU
• Red gain adjustment -100 to 100
• Blue gain adjustment -100 to 100
• Color temperature setting 3200, 5600
R GAIN
B GAIN
C. TEMP
0
0
3200
(a) Changing the red gain
Set the "→" to R GAIN by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Set the red gain by pushing [DATA UP], [DATA DOWN] buttons.
(b) Changing the blue gain
Set the "→" to B GAIN by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Set the blue gain by pushing [DATA UP], [DATA DOWN] buttons.
19
( 4 ) PROCESS
Move up down
By pushing
MENU UP, DOWN
Set by pushing
DATA UP, DOWN
-- PROCESS --
• Master pedestal adjustment -64 to 64
M.PED
R.PED
B.PED
SHAD.
MANU
0
0
0
• R pedestal adjustment -64 to 64
• B pedestal adjustment -64 to 64
• Shading mode setting MANU/OFF
• Manual shading adjustment -128 to 127
MANU
0
(4. 1) Changing master pedestal
Set the "→" to M. PED by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Set the master pedestal by pushing [DATA UP], [DATA DOWN] buttons.
(4. 2) Changing R pedestal
Set the "→" to R. PED by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Set the R pedestal by pushing [DATA UP], [DATA DOWN] buttons.
(4. 3) Changing B pedestal
Set the "→" to B. PED by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Set the B pedestal by pushing [DATA UP], [DATA DOWN] buttons.
(4. 4) Changing the shading correction mode
Set the "→" to SHAD. by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Set the SHAD. by pushing [DATA UP], [DATA DOWN] buttons.
Note: The alignment value for shading is fixed to "0" when selecting SHAD. OFF. MANU is not dis-
played in the menu.
(4. 5) Changing the manual shading correction setting
Set the "→" to MANU by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Set the MANUAL SHADING by pushing [DATA UP], [DATA DOWN] buttons.
20
( 5 ) SYNC
When an external sync signal is input, the display menu changes from INT (internal sync) to EXT (external
sync) automatically.
Move up down
Set by pushing
By pushing
MENU UP, DOWN
DATA UP, DOWN
-- SYNC --
MODE
H PHASE
EXT
0
• Sync system display
• H PHASE -100 to 100
(5. 1) Adjusting horizontal phase
Set the "→" to H PHASE by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Adjust the horizontal phase by pushing [DATA UP], [DATA DOWN] buttons.
( 6 ) OPTION
Move up down
By pushing
MENU UP, DOWN
Set by pushing
DATA UP, DOWN
-- OPTION --
BAUD RATE
9600
• Serial baud rate 9600, 19200
(6. 1) Changing serial communication baud rate
Set the "→" to BAUD RATE by pushing [MENU UP], [MENU DOWN] buttons.
1
2
Select either 9600 or 19200 by pushing [DATA UP], [DATA DOWN] buttons.
21
( 7 ) Setting to factory setting status
All the settings can be returned to the factory default status (preset status).
(1) If characters are displayed on the screen, press the [DISP] button to disable the character display.
(2) Push [MENU DOWN] and [DATA DOWN] buttons simultaneously for approx. 1 second.
(3) The preset operation starts. When the preset operation finishes, the character PRESET OK is displayed
for approx. 1 second.
7. 3 External Sync
When using the unit with an external sync signal, input HD and VD to CC3 and CC4 of the DIGITAL terminal.
When the external sync signal is input, the camera automatically switches its sync from the internal sync to the
external sync.
The operation is as shown below, depending on the unit's status and how external sync signals are input.
Shutter mode
At time of SYNC-NON
RESET mode
HD input VD input
Note
N
Y
N
Y
N
Y
Y
N
Internal sync mode
External sync mode
Only V reset is applied due to VD input. Normally not used.
HD is synchronized to external, but video is not output
because there is no VD input. Normally not used.
At time of SYNC-RESET
mode
N
Y
*
*
Internal sync mode. The presence of VD is ignored, and after
a specified time after a trigger input, V reset is applied.
HD is synchronized to external. The presence of VD is
ignored, and after a specified time after a trigger input, V
reset is applied.
At time of reset restart
Y
N
*
Y
Y
N
HD is synchronized to external. Video is output due to VD
input.
HD is synchronized to the inside of the camera. Video is
output due to VD input.
Video is not output because there is no VD input. Normally
not used.
At time of manual
shutter
N
Y
Y
N
N
Y
N
Y
Internal sync mode
External sync mode
HD is synchronized to external. Normally not used.
Disabled
* Either Y or N is permitted.
( 1 ) External sync signal polarity
HD: 2 to 5V(p-p) Negative
VD: 2 to 5V(p-p) Negative
( 2 ) External sync frequency range
(External sync with HD, VD)
Within 1% (at horizontal sync frequency of 23.229 kHz)
22
( 3 ) Using the unit with external sync signal
When adjusting H (horizontal) phase refer to the item "7.2 (5) (5.1) Adjusting horizontal phase".
External
Sync. signal
(3. 1) H (horizontal) phase adjustment
Match
the phase.
Observe the external sync signal and the LVAL signal output
waveform of the unit with a dual trace oscilloscope, and ad-
just H phase so that the H phases match.
LVAL signal
output
7. 4 Synchro. Scan Operation
The shutter speed can be set by the horizontal scanning period (1H) or by the frame.
( 1 ) Setting by 1H
1H/796H to 795H/796H (1H/387H to 386H/387H when partial scanning at 60fps, E.60fps 1H/258H to 257H/
258H when partial scanning at 90fps, E.90fps) stands for the setting by the 1H and the shutter speed can be
set by the 1H (43.05 µs).
( 2 ) Setting by the frame
2FRM to 512FRM stand for the setting (long period exposure) by the frame.
The video signal stored during the frame period set is output as 1 frame video image at a frame interval
specified.
(Internal VD)
n
n+1
RGB data
(video interval image)
FVAL
LVAL,
DAVL
(4FRM setting)
23
7. 5 EXT TRIG (External trigger)
Charge begins to accumulate after the trigger input to CC1 of the DIGITAL terminal, and 1 frame images are
output. There are five modes: 1P SNR, 1P SR, PW SNR, PW SR, RR.
( 1 ) 1P SNR (1 Pulse Trigger Sync Non Reset)
Charge begins to accumulate after the trigger input to CC1 of the DIGITAL terminal, and 1 frame images are
output.
(1. 1) 1 Pulse Trigger SYNC-NON RESET Picture Output Timing
Negative polarity mode
Trigger*1
Positive polarity mode
About 1 µs
Exposure period*2
Exposure period*2
External HD IN*1
External VD IN*1
About 1H
(Internal VD)
RGB data
(video interval image)
FVAL
LVAL,
DVAL
28H (Partial scanning OFF)
38H (Partial scanning 60fps)
47H (Partial scanning 90fps)
The internal VD falling edge is within the
exposure period and thus video is not output.
3
*
(At Time of One-shot or Continuous External VD/Continuous External HD Input)
*1: Externally input signal
*2: Exposure time is determined by the setting of "7. 2 (1.3) Changing each setting in E.TRG mode".
*3: Video is output at the falling edge of the internal VD following completion of the exposure period.
The video and FVAL/LVAL/DVAL have a paired relationship.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trig-
24
ger, there will be an effect on the video.
Negative polarity mode
Positive polarity mode
Trigger*1
About 1 µs
Exposure period*2
Exposure period*2
3
(Internal VD)
*
RGB data
(video interval image)
FVAL
LVAL,
DVAL
28H (Partial scanning OFF)
38H (Partial scanning 60fps)
47H (Partial scanning 90fps)
(1. 2) 1 Pulse Trigger SYNC-NON RESET Picture Output Timing (at Time of Internal Sync)
*1: Externally input signal
*2: Exposure time is determined by the setting of "7. 2 (1.3) Changing each setting in E.TRG mode".
As long as there is no external sync input, the internal VD will be output when SJ01 is set to HD/VD output
position.
*3: Video is output at the falling edge of the internal VD following completion of the exposure period.
The video and FVAL/LVAL/DVAL have a paired relationship.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trig-
ger, there will be an effect on the video.
25
( 2 ) 1P SR (1 Pulse Trigger Sync Reset)
Charge begins to accumulate after the trigger input to CC1 of the DIGITAL terminal, the vertical sync signal is
reset and frame images are output.
(2. 1) 1 Pulse Trigger SYNC-RESET Picture Output Timing
Negative polarity mode
Trigger*1
Positive polarity mode
About 1 µs
Exposure period*2
Exposure completion
0 to 1H*3
(Internal VD)
RGB data
(video interval image)
FVAL
LVAL,
DVAL
28H (Partial scanning OFF)
38H (Partial scanning 60fps)
47H (Partial scanning 90fps)
*1: Externally input signal
*2: Exposure time is determined by the setting of "7. 2 (1.3) Changing each setting in E.TRG mode".
*3: VD is generated after 0 to 1H following the completion of the exposure period and the video is synchro-
nized to this and output.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trig-
ger, there will be an effect on the video.
26
( 3 ) PW SNR (Pulse width trigger SYNC-NON RESET)
The trigger input to CC1 of the DIGITAL terminal develops 1 frame images.
(3. 1) Pulse Width Trigger SYNC-NON RESET Picture Output Timing
(At Time of One-shot or Continuous External VD/Continuous External HD Input)
Negative polarity mode
Trigger*1
Positive polarity mode
About 7 µs
About 1 µs
Exposure period*2
Exposure period*2
External HD IN*1
External VD IN*1
(Internal VD)
About 1H
RGB data
(video interval image)
FVAL
LVAL,
DVAL
28H (Partial scanning OFF)
38H (Partial scanning 60fps)
47H (Partial scanning 90fps)
The internal VD falling edge is within the
exposure period and thus video is not output.
3
*
*1: Externally input signal
*2: Exposure time = Trigger pulse width + 6 µs
(Valid trigger pulse width is 2 µs or greater for external trigger shutter operation.)
*3: Video is output at the falling edge of the internal VD following completion of the exposure period.
The video and FVAL/LVAL/DVAL have a paired relationship.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trig-
ger, there will be an effect on the video.
27
(3. 2) Pulse Width Trigger SYNC-NON RESET Picture Output Timing (at Time of Internal Sync)
Negative polarity mode
Positive polarity mode
Trigger*1
About 7 µs
About 1 µs
Exposure period*2
Exposure period*2
3
(Internal VD)
RGB data
*
(video interval image)
FVAL
LVAL,
DVAL
28H (Partial scanning OFF)
38H (Partial scanning 60fps)
47H (Partial scanning 90fps)
*1: Externally input signal
*2: Exposure time = Trigger pulse width + 6 µs
(Valid trigger pulse width is 2 µs or greater for external trigger shutter operation.)
*3: As long as there is no external sync input, the internal VD will be output when SJ01 is set to HD/VD output
position.
*4: Video is output at the falling edge of the internal VD following completion of the exposure period.
The video and FVAL/LVAL/DVAL have a paired relationship.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trig-
ger, there will be an effect on the video.
28
( 4 ) PW SR (Pulse width trigger SYNC-RESET)
The trigger input to CC1 of the DIGITAL terminal develops 1 frame images.
(4. 1) 1 Pulse Width Trigger SYNC-RESET Picture Output Timing
Negative polarity mode
Positive polarity mode
Trigger*1
About 1 µs
About 7 µs
Exposure period*2
Exposure completion
0 to 1H
3
(Internal VD)
*
RGB data
(video interval image)
FVAL
LVAL,
DVAL
28H (Partial scanning OFF)
38H (Partial scanning 60fps)
47H (Partial scanning 90fps)
*1: Externally input signal
*2: Exposure time = Trigger pulse width + 6 µs
(Valid trigger pulse width is 2 µs or greater for external trigger shutter operation.)
*3: VD is generated after 0 to 1H following the completion of the exposure period and the video is synchro-
nized to this and output.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trig-
ger, there will be an effect on the video.
29
( 5 ) RR (Reset restart)
Input of an external reset-restart signal (CC4 of the DIGITAL terminal: External VD input) permits one screen
of information to be output at an arbitrary timing.
(5. 1) Long Term Exposure
When a sufficient sensitivity is not obtained with the normal operating conditions or capturing the trail of a
moving subject is desired, the reset-restart function allows high-sensitivity images by extending the exposure
time. To achieve this, please input from an external source a VD signal that has an expanded VD pulse and VD
pulse interval.
(5. 2) Input Timing Chart Example
External HD IN
External VD IN
V reset
V reset
About 1H
About 1H
(Internal VD)
Exposure period
Exposure period
Exposure period
RGB data
(video interval image)
FVAL
LVAL,
DVAL
1 frame
1 frame= 796H (Partial scanning OFF
)
387H (Partial scanning 60fps)
258H (Partial scanning 90fps)
External VD interval: more than 1 frame
30
7. 6 Partial Scanning
( 1 ) Partial Scanning OFF (All pixels scanning)
In this mode, all pixels independent signal from the DIGITAL connector is output with increased flame rate.
Video interval
image
1/29.2s (796H)
( 2 ) Partial Scanning ON
In this mode, the pixel signal of the vertical center portion from the DIGITAL connector is output.
In the E.60fps or E.90fps mode, the partial scanning and the all pixels scanning can be switched by the
DIGITAL terminal (CC2: partial scanning control signal).
CC2
‘L’
E.90fps
E.60fps
Partial scanning 90fps
All pixels scanning
Partial scanning 60fps
All pixels scanning
‘H’
Video interval
image
1/60s (387H): When 60fps is selected
1/90s (258H): When 90fps is selected
( 3 ) When Partial Scanning Mode is ON
(Internal VD)
FVAL
LVAL,
DVAL
RGB data
(video interval image)
Blanking interval
Video interval Blanking interval
B
C
D
Total
A
Video period
Mode
60fps
90fps
Total A
387H
Blanking interval B Video interval C Blanking interval D
38H
47H
322H
175H
27H
36H
258H
31
8. INPUT OUTPUT SIGNAL SPECIFICATOINS
( 2 ) VD Input Specifications
( 1 ) HD Input Specifications
5H to 21H
2.0 µs to 5.0 µs
( 3 ) Trigger Pulse Specifications
(Positive polarity mode)
More than 2 µs
(Negative polarity mode)
More than 2 µs
( 6 ) External HD/VD Input Phase Specifications
External HD
rising edge
100
100
External HD
Unit : Clock
1 clk=33.9nsec
Center
The phase relationship of the external HD and VD should correspond to the center phase (i.e., the external HD falling
edge) as illustrated in the above diagram.
External VD falling edge:
Please input within about 100 clock cycles of the standard center phase.
Note that V sync of the video is output with a delay of about 1H from the external VD at the time of reset-restart and
the external trigger mode.
In the normal mode:
Continuously with the HD period of 43.05 µs and VD period of 34.27 ms (partial scanning 60fps: 16.67 ms, partial
scanning 90fps: 11.11 ms ).
Phase timing is as illustrated in the above diagram (with only the falling edge applicable).
In the reset-restart/external trigger mode:
Continuously with the HD period of 43.05 µs. VD (reset) is at an arbitrary timing with the phase of HD being within the
standard of the above diagram.
32
9. CCD OUTPUT WAVEFORM TIMING CHART
( 1 ) Horizontal Output Waveform Timing Chart
One horizontal scan interval 1270 clk
(43.05 µs)
LVAL,
DVAL
246 clk
(8.34µs)
33.9 ns
29 clk 3 clk
40 clk
164 clk
CCD
output signal
5 clk
5
clk
Optical black Horizontal transfer Dummy
portion
stop interval
pixels
Total effective pixels 1034 clk
Optical black
portion
Horizontal blanking interval 246 clk
Output video interval 1024 clk
(8.34 µs)
(34.71 µs)
RGB data
Pixel
Clock
CLK=33.9 nsec
(29.5 MHz)
( 2 ) Vertical Output Waveform Timing Chart
796H
28H
(1205µs)
FVAL
LVAL,
DVAL
768H
CCD
output signal
1
1
2
3
4
5
6
7
1
1
2
3
4
5
6
7
Dummy
pixels
Dummy
pixels
Optical black
portion
Optical black
portion
Optical black
portion
Optical black
portion
Vertical blanking interval 28H
Vertical blanking interval 28H
(1205µs)
(1205µs)
RGB data
33
10. SPECIFICATIONS
Power supply
DC12V 10%
Power consumption
Pick-up system
Approx.4.3W
RGB, 3CCD
Image sensor
1/3inch All pixels CCD
(Effective pixels)
(Horizontal : 1034pixels, Vertical : 779pixels)
Scanning system
Scan frequency
Sync system
Progressive scan
Horizontal : 23.229kHz, Vertical : 29.18Hz
Internal/External (Automatic switching)
768TV lines
F6.8 standard (2000 lx, 3000K)
14 lx (F2.2, Sensitivity + 18 dB, 3000K)
C mount (flange back : 17.526 mm in-air)
32 to 104°F (0 to 40°C)
Horizontal resolution
Sensitivity
Minimum illumination
Lens mount
Ambient temperature
Ambient humidity
Weight
Less than 90%
Approx. 5.82oz (165g)
External dimension
1.73” (W) x 1.73” (H) x 3.07” (D)
(44 (W) x 44 (H) x 78 (D) mm)
(except for protruded portion)
White balance
Gain
AWB (Automatic white balance), MANUAL (Manual)
MANUAL (Manual), OFF (0 dB)
Output signal
Sync signal output
8-bit RGB, Digital output (Camera Link format)
FVAL, LVAL, DVAL (Positive polarity)
Pixel Clock (29.5MHz)
External sync input
Interface
HD or VD : Negative
Serial data interface: Ser TC (RXD), Ser TFG (TXD)
EXC-CL05S (Cable), etc
Optional parts
The designs and specifications are subject to change without notice.
34
11. EXTERNAL APPEARANCE DIAGRAM
Unit : mm [inch]
5
[0.20]
12
[0.47]
2-M3 Depth 3
6.3
[0.25]
44
[1.73]
78
[3.07]
(AWB)
DISP
DATA
MENU
DC IN 12V
PAGE
4.8
[0.19]
5
56
[2.20]
2-M2
[0.20]
4-M3 Depth 3
19.2
[0.76]
4-M2 Depth 3
25
[0.98]
25
[0.98]
∗ inch=mm/25.4
12. BEFORE MAKING A SERVICE CALL
Symptom
Items to be checked
No image
• Is the power supplied correctly?
• Is the lens iris adjusted correctly?
• Are the cables connected correctly?
• Is the shutter mode set correctly?
• Is the image process equipment set correctly?
Poor color
• Is the monitor adjusted correctly?
• Is the white balance of the camera adjusted correctly?
• Is the illumination dark?
35
LIMITED WARRANTY
TOSHIBA CCD CAMERA
Promptly register your product with Toshiba on-line at www.toshiba.com/taisisd. By registering your prod-
uct you will be eligible for periodic updates, announcements, and special offers.You will have access to extended
warranty options, upgrades (as applicable), useful tips, on-line troubleshooting, and the ability to schedule service
on-line if necessary. The Imaging Systems Division of Toshiba America Information Systems, Inc. ("ISD") makes
the following limited warranties. These limited warranties extend to the Original End-User ("Your[r]").
Limited One (1) Year Warranty of Labor and Parts
ISD warrants this product and parts against defects in material or workmanship for a period of one year from the
date of original retail purchase by the end-user. During this period, ISD will repair or replace a defective product or
part with a new or refurbished item. The user must deliver the entire product to an ISD authorized service center.
The user is responsible for all transportation and insurance charges for the product to the Service Center. ISD
reserves the right to substitute Factory Refurbished Parts and / or Factory Refurbished Product in place of those
in need of repair.
Step-by-step Procedures - How to Obtain Warranty Service
[1] Verify operation of the unit by checking the instruction manual
[2] If there is a defect in material or workmanship, contact an Authorized Service Provider within 30 days after the
product fails to comply with specifications.
[3] Arrange for delivery of the product to the ISD authorized service center. Products must be insured and securely
packed, preferably in the original shipping carton. A letter explaining the defect and a copy of the bill of sale or
other proof of purchase must be enclosed with a complete return street address and daytime telephone number.
Charges for transportation and insurance must be prepaid by the end-user.
Questions? If you have any questions, please check the Toshiba Imaging Systems Division Web site as
follows:
Website:
Your Responsibility, warranties are subject to the following conditions:
[1] You must retain the bill of sale or provide other proof of purchase.
[2] You must schedule service within thirty days after you discover a defective product or part.
[3] All warranty servicing of this product must be made by a Toshiba ISD Authorized Service Provider.
[4] The warranty extends to defects in material or workmanship as limited above, and not to any products or parts
that have been lost or discarded by user. The warranty does not cover damage caused by misuse, accident,
improper installation, improper maintenance, or use in violation of instructions furnished by ISD. The warranty
does not extend to units which have been altered or modified without authorization of ISD, or to damage to prod-
ucts or parts thereof which have had the serial number removed, altered defaced or rendered illegible.
ALL WARRANTIES IMPLIED BY STATE LAW, INCLUDING THE IMPLIED WARRANTIES OF MERCHANT-
ABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY LIMITED TO THE DURATION OF
THE LIMITED WARRANTIES SET FORTH ABOVE. Some states do not allow limitations on how long an
implied warranty lasts, so the above limitation may not apply. WITH THE EXCEPTION OF ANY WARRAN-
TIES IMPLIED BY STATE LAW AS HEREBY LIMITED, THE FOREGOING EXPRESS WARRANTY IS EXCLU-
SIVE AND IN LIEU OF ALL OTHER WITH RESPECT TO THE REPAIR OR REPLACEMENT OF ANY PROD-
UCTS OR PARTS. IN NO EVENT SHALL ISD BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAM-
AGES. Some states do not allow the exclusion or limitation of incidental or consequential damages so the
above limitation may not apply.
No person, agent, distributor, dealer, service station or company is authorized to change, modify or ex-
tend the terms of these warranties in any manner whatsoever. The time within which an action must be
commenced to enforce any obligation of ISD arising under this warranty or under any statute, or law of the
United States or any state thereof, is hereby limited to one year from the date you discover or should have
discovered, the defect. This limitation does not apply to implied warranties arising under state law. Some
states do not permit limitation of the time within which you may bring an action beyond the limits provided
by state law so the above provision may not apply to user. This warranty gives the user specific legal
rights, and user may also have other rights, which may vary from state to state.
TOSHIBA AMERICA INFORMATION SYSTEMS, INC.
Imaging Systems Division
Copyright © 2002 Toshiba America, Inc. All rights reserved.
|