Planning Information
Model W362418(R) Pro Wall Hood
Hand finished
craftsmanship
Classic stainless
steel finish
Backdraft damper
Model W362418
Decorative rail
(optional)
Stainless steel
baffle filters
Model W362418R
– Rail Option
Welded seams
and hemmed edges
Recessed easy
access controls
Halogen lighting
Infinite speed
blower control
Model W362418R shown with standard classic stainless steel
decorative rail, platinum or brass rail available as a sales accessory
Wolf Pro wall hoods provide the ultimate in
ventilation. With standard elements like heat sentry
and dual setting halogen lighting, Wolf elevates the
need for ventilation to an enjoyable perk.
Wolf Pro 24" (610) deep wall hoods
are available in the classic stainless steel
finish. Rail option hoods (R) come with a
classic stainless steel decorative rail and
stand-offs. Optional platinum or brass
rails match dual fuel range bezels. Pro
wall hoods are sold as a shell only;
internal, in-line and remote blower
options are available
Pro 24" (610) deep wall hoods are available in the
classic stainless steel finish. You also have the option
of a decorative rail. While a classic stainless steel rail
is standard on (R) models, platinum or brass rails are
available to match the bezels of our dual fuel ranges
and sealed burner rangetops.
Pro wall ventilation hoods are recommended for use
with all Wolf cooking appliances. For optimal perform-
ance, a Pro 27" (686) deep wall hood is recommended
for use with ranges and rangetops that contain a
charbroiler or griddle.
Dimensions in parentheses are in
millimeters unless otherwise specified.
1
9/06
Planning Information
Model W362418(R) Pro Wall Hood
B L O W E R O P T I O N S
S P E C I F I C A T I O N S
Overall Width of Hood
Overall Height of Hood
600 CFM Internal Blower
900 CFM Internal Blower
1100 CFM In-Line Blower
900 CFM Remote Blower
1200 CFM Remote Blower
1500 CFM Remote Blower
Refer to the Pro Ventilation
807614
805086
808332
801641
801642
804701
36" (914)
18" (457)
Overall Depth of Hood – W362418
W362418R (including rail)
24" (610)
26" (660)
Duct Size
10" (254) Round
Discharge
Vertical (internal and in-line blowers)
Vertical or Horizontal (remote blowers)
Electrical Supply Requirements
110/120 V AC, 60 Hz
15 amp dedicated circuit
Recommendations chart at the end
of this section.
Shipping Weight
78 lbs (35 kg)
A C C E S S O R I E S
For optimal performance, a Pro 27" (686) deep wall hood is
recommended for use with ranges and rangetops that contain a
charbroiler or griddle.
Platinum or brass decorative rail
and stand-offs
Specifications are subject to change without notice.
38" (965) high stainless steel
backsplash with or without
warming rack
6" (152) and 12" (305) duct covers
Recirculating kit
Contact your Wolf dealer for additional
information on accessories.
Dimensions in parentheses are in
millimeters unless otherwise specified.
3
Planning Information
Model W362418(R) Pro Wall Hood
I N S T A L L A T I O N S P E C I F I C A T I O N S
LOCATION OF
6"
E
ELECTRICAL (152)
5"
(127)
18" (457)
HEIGHT
OF HOOD
36" (914)
WIDTH OF HOOD
(
)
30" TO 36"
(762–914)
30" TO 36"
(762–914)
24" 610
DEPTH OF HOOD
TO COUNTERTOP
TO COUNTERTOP
NOTE: Horizontal discharge is applicable on 24" (610) deep wall hoods used with WBLOWER-60INT or any remote blower. WBLOWER-90INT
is not for use in horizontal discharge applications. 27" (686) deep wall hoods are vertical discharge only.
D I M E N S I O N S
Overall Width of Hood
36" (914)
18" (457)
Overall Height of Hood
Overall Depth of Hood (excluding rail)
Countertop to Bottom of Hood
Location of Electrical
24" (610)
30" (762) to 36" (914)
Within shaded area
See Installation Instructions shipped with unit for detailed specifications.
Dimensions in parentheses are in
millimeters unless otherwise specified.
4
Planning Information
Model W362418(R) Pro Wall Hood
I N S T A L L A T I O N N O T E S
Refer to the illustrations and specifications
for overall dimensions and installation specifics.
Pro wall hoods require a separate, grounded
110/120 V AC, 60 Hz power supply. The service
should have its own 15 amp circuit breaker.
Placement of the electrical supply is not critical,
as long as you provide a minimum of 6" (152)
of 120 V AC, 60 Hz power cable. Locate electri-
cal within the shaded area shown in the Instal-
lation illustration. Note that the location of the
electrical supply will differ between vertical and
horizontal discharge blowers.
Wolf Pro wall ventilation hoods are recom-
mended for use with any Wolf cooking appli-
ance, and should be at least as wide as the
cooking surface. It is recommended that the
hood overlap the cooking surface by 3" (76) on
either side.
For optimal performance, a Pro 27" (686)
deep wall hood is recommended for use with
ranges and rangetops that contain a charbroiler
or griddle.
You must follow all National Electrical Code
regulations. In addition, be aware of local codes
and ordinances when installing your service.
Installation of all Pro wall hoods should be
30" (762) to 36" (914) from the bottom of the
hood to the countertop. Follow the dimensions
shown in the Installation illustration.
Refer to the installation instructions shipped
with each Wolf product for detailed specifica-
tions. This information can also be found on
our website, wolfappliance.com.
Wolf Pro wall hoods are shipped without a
blower assembly. Internal, in-line and remote
blower assemblies are available. Blower options
also vary with the volume of air that needs to be
moved and the length of the duct run. Refer to
the end of this section for Pro ventilation
recommendations and blower options.
IMPORTANT NOTE: Install this ventilation hood
only with a Wolf blower.
Dimensions in parentheses are in
millimeters unless otherwise specified.
5
Planning Information
Model W362418(R) Pro Wall Hood
D U C T I N G C O N S I D E R A T I O N S
Wolf Pro 24" (610) deep wall hoods are shipped
without the blower assembly. Internal, in-line or
remote blower assemblies are available. The
remote blower can be mounted on the roof or an
exterior wall. Refer to the illustration below for
ducting options.
Pro 24" (610) deep wall hoods have an adjust-
able discharge location that can run vertically or
horizontally. Horizontal discharge is applicable
on 24" (610) deep hoods used with WBLOWER-
60INT or WBLOWER-120INT or any remote
blower. WBLOWER-90INT is not for use in hori-
zontal discharge applications.
Refer to the Pro ventilation charts at the end of
this section for recommendations and blower
options.
Ducting considerations for
Pro 24" (610) deep wall
DUCTWORK INSTALLATION
hoods.
THROUGH ROOF
ROOF CAP OR REMOTE BLOWER
10" ROUND DUCT
TRANSITION
221/4"W x 9"D TO 10" ROUND
10"H (INCLUDING FLANGES)
SOFIT OR CABINET
OR DUCT COVER
VERTICAL DISCHARGE
WALL CAP
OR REMOTE BLOWER
18" (457)
HEIGHT OF HOOD
WALL HOOD
DUCTWORK INSTALLATION
THROUGH WALL
DISCHARGE COLLAR
24" (610)
DEPTH OF HOOD
HORIZONTAL
DISCHARGE*
30" TO 36"
(762–914)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
*HORIZONTAL DISCHARGE IS APPLICABLE ON 24" (610) DEEP WALL HOODS
USED WITH WBLOWER-60INT, WBLOWER-120INT OR ANY WOLF REMOTE BLOWER.
WBLOWER-90INT IS NOT FOR USE IN HORIZONTAL DISCHARGE APPLICATIONS.
Dimensions in parentheses are in
millimeters unless otherwise specified.
6
Planning Information
Wolf Ventilation Recommendations
W O L F B L O W E R A S S E M B L I E S
A ventilation system must include a blower
assembly. With a few exceptions where internal
blowers are included, Wolf ventilation hoods and
downdrafts are shipped without the blower
assembly. An internal, in-line or remote blower
assembly must be selected to accommodate the
cooking appliance, CFM requirements and home-
owner preferences. Internal, in-line and remote
blower assemblies are available as sales acces-
sories through your Wolf dealer.
IMPORTANT NOTE: Use only a Wolf blower
with all Wolf ventilation products.
Internal blowers are mounted inside the hood
canopy or downdraft blower box. In-line blowers
are mounted in between the hood and the
exterior of the home. Remote blowers can be
mounted on the roof or in some cases, on an
exterior wall. Refer to the illustrations below for
dimensions of Wolf in-line and remote blowers.
Ventilation recommendation charts on the
Wolf internal, in-line and remote blowers are for
use with Wolf cooktop hoods, downdraft
systems and Pro ventilation hoods and hood
liners.
following pages provide minimum CFM recom-
mendations according to the cooking appliance
and ventilation system used and blower options
for each specific ventilation hood or downdraft.
7
24 /8"
3
24 /8"
(632)
(619)
3
11 /4"
(298)
18"
12"
(457)
1
(305)
18 /2"
(470)
1
4 /2"
(114)
8"
(203)
1
21 /2"
1
(546)
22"
12 /4"
(311)
18"
(559)
(457)
In-line BLOWER-60IL
In-line BLOWER-110IL
18" (457)
21" (533)
3
20 /4"
10"
10"
(527)
(254)
(254)
1
1
28 /4"
29 /2"
1
29 /2"
(749)
(718)
(749)
10" (254)
Diameter
10" (254)
Diameter
10" (254)
Diameter
1
3
15 /2"
(394)
3
14 /4"
(375)
14 /4"
(375)
1
1
29 /2"
1
29 /2"
24 /2"
(749)
(749)
(622)
1
3
14"
10 /8"
10 /8"
(356)
(257)
(264)
3
4
/4"
3
(121)
24 /4"
(629)
1
7
1
7
22"
25"
/4"
/4"
(559)
(635)
(184)
(184)
Remote BLOWER-60REM and
BLOWER-90REM
Remote BLOWER-120REM
Remote BLOWER-150REM
Dimensions may vary by 1/8" (3).
Dimensions in parentheses are in
millimeters unless otherwise specified.
7
Planning Information
Wolf Ventilation Recommendations
P R O V E N T I L A T I O N C F M R E C O M M E N D AT I O N S
Pro 24" (610) Deep Wall Hoods
W302418 W362418 W422418 W482418 W542418 W602418 W662418
600 600
900
DF304 / R304 / SRT304
DF366 / R366 / SRT366 / RT366
DF364 / R364 / SRT364 / RT364
RT362
900
900
900
900
900
R488 / RT488
1100
1100
1100
1100
1100
1100
1100
1100
DF486 / R486 / SRT486 / RT486
DF484 / R484 / SRT484 / RT484
R482 / RT482
DF606 / R606
1500
1500
1500
1500
DF604 / R604
NOTE: For optimal performance, a Pro 27" (686) deep wall hood is recommended for use with ranges and rangetops that contain a
charbroiler or griddle.
Model numbers for dual fuel ranges, gas ranges, sealed burner rangetops and gas rangetops indicate width and number of surface
burners. Features such as a charbroiler, griddle and/or French Top will vary.
CFM recommendations are based on total Btu/hr output. Wolf recommends 1 CFM per 100 Btu/hr (.03 kW). Additional CFM may be
required for long duct runs.
P R O V E N T I L A T I O N B L O W E R O P T I O N S
Pro 24" (610) Deep Wall Hoods
Blower Description
600 CFM Internal
900 CFM Internal*
1200 CFM Internal
600 CFM In-Line*
1100 CFM In-Line*
600 CFM Remote
900 CFM Remote
1200 CFM Remote
1500 CFM Remote
Blower Number
Wall Hood Models
W302418 / W362418 / W422418
W302418 / W362418 / W422418
W482418 / W542418 / W602418 / W662418
W302418
WBLOWER-60INT (807614)
WBLOWER-90INT (805086)
WBLOWER-120INT (804702)
BLOWER-60IL (808331)
BLOWER-110IL (808332)
BLOWER-60REM (801640)
BLOWER-90REM (801641)
BLOWER-120REM (801642)
BLOWER-150REM (804701)
All 24" (610) Deep Wall Hoods
W302418
W302418 / W362418 / W422418 / W482418 / W542418
All 24" (610) Deep Wall Hoods
All 24" (610) Deep Wall Hoods
*Vertical discharge with 10" (254) round duct. All other blowers are adjustable discharge with 10" (254) round duct. NOTE: For optimal
performance, a Pro 27" (686) deep wall hood is recommended for use with ranges and rangetops that contain a charbroiler or griddle.
Wall hood models without decorative rail listed; blower options are the same for (R) models. Transition with backdraft damper included
with all wall hoods. Blower configurations are for reference only. Refer to minimum CFM recommendations for your specific cooking
product. Always consult a qualified HVAC Engineer for specific applications.
Dimensions in parentheses are in
millimeters unless otherwise specified.
8
|