Philips Stereo Amplifier BGD602 User Manual

DISCRETE SEMICONDUCTORS  
DATA SHEET  
BGD602  
CATV amplifier module  
February 1994  
Product specification  
File under Discrete Semiconductors, SC16  
Philips Semiconductors  
 
Philips Semiconductors  
Productspecification  
CATV amplifier module  
BGD602  
CHARACTERISTICS  
Bandwidth 40 to 600 MHz; VB = 24 V; Tmb = 35 °C; ZS = ZL = 75 .  
SYMBOL  
PARAMETER  
CONDITIONS  
f = 50 MHz  
MIN.  
18  
MAX.  
19  
UNIT  
dB  
Gp  
power gain  
f = 600 MHz  
19  
0.2  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
deg  
dB  
SL  
FL  
slope cable equivalent  
flatness of frequency response  
input return losses  
f = 40 to 600 MHz  
f = 40 to 600 MHz  
f = 40 to 80 MHz  
f = 80 to 160 MHz  
f = 160 to 600 MHz  
f = 40 to 80 MHz  
f = 80 to 160 MHz  
f = 160 to 600 MHz  
f = 50 MHz  
2.2  
±0.3  
+45  
62  
S11  
20  
19  
18  
20  
19  
18  
45  
S22  
output return losses  
S21  
phase response  
CTB  
composite triple beat  
85 channels flat;  
Vo = 44 dBmV;  
measured at 595.25 MHz  
Xmod  
CSO  
cross modulation  
85 channels flat;  
Vo = 44 dBmV;  
measured at 55.25 MHz  
66  
dB  
dB  
composite second order distortion  
85 channels flat;  
Vo = 44 dBmV;  
60  
measured at 596.5 MHz  
d2  
Vo  
F
second order distortion  
output voltage  
note 1  
63  
70  
dB  
dim = 60 dB; note 2  
f = 600 MHz  
note 3  
dBmV  
dB  
noise figure  
8
Itot  
total current consumption (DC)  
435  
mA  
Notes  
1. fp = 55.25 MHz; Vp = 44 dBmV;  
fq = 541.25 MHz; Vq = 44 dBmV;  
measured at fp + fq = 596.5 MHz.  
2. Measured according to DIN45004B:  
fp = 590.25 MHz; Vp = Vo;  
fq = 597.25 MHz; Vq = Vo 6 dB;  
fr = 599.25 MHz; Vr = Vo 6 dB;  
measured at fp + fq fr = 588.25 MHz.  
3. The module normally operates at VB = 24 V, but is able to withstand supply transients up to 30 V.  
February 1994  
3
 
Philips Semiconductors  
Productspecification  
CATV amplifier module  
BGD602  
CHARACTERISTICS  
Bandwidth 40 to 550 MHz; VB = 24 V; Tmb = 35 °C; ZS = ZL = 75 .  
SYMBOL  
PARAMETER  
CONDITIONS  
f = 50 MHz  
MIN.  
18  
MAX.  
19  
UNIT  
dB  
Gp  
power gain  
f = 550 MHz  
18.8  
0.2  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
deg  
dB  
SL  
FL  
slope cable equivalent  
flatness of frequency response  
input return losses  
f = 40 to 550 MHz  
f = 40 to 550 MHz  
f = 40 to 80 MHz  
f = 80 to 160 MHz  
f = 160 to 550 MHz  
f = 40 to 80 MHz  
f = 80 to 160 MHz  
f = 160 to 550 MHz  
f = 50 MHz  
2.2  
±0.3  
+45  
66  
S11  
20  
19  
18  
20  
19  
18  
45  
S22  
output return losses  
S21  
phase response  
CTB  
composite triple beat  
77 channels flat;  
Vo = 44 dBmV;  
measured at 547.25 MHz  
Xmod  
CSO  
cross modulation  
77 channels flat;  
Vo = 44 dBmV;  
measured at 55.25 MHz  
68  
dB  
dB  
composite second order distortion  
77 channels flat;  
Vo = 44 dBmV;  
62  
measured at 548.5 MHz  
d2  
Vo  
F
second order distortion  
output voltage  
note 1  
64  
72  
7.5  
435  
dB  
dim = 60 dB; note 2  
f = 550 MHz  
note 3  
dBmV  
dB  
noise figure  
Itot  
total current consumption (DC)  
mA  
Notes  
1. fp = 55.25 MHz; Vp = 44 dBmV;  
fq = 493.25 MHz; Vq = 44 dBmV;  
measured at fp + fq = 548.5 MHz.  
2. Measured according to DIN45004B:  
fp = 540.25 MHz; Vp = Vo;  
fq = 547.25 MHz; Vq = Vo 6 dB;  
fr = 549.25 MHz; Vr = Vo 6 dB;  
measured at fp + fq fr = 538.25 MHz.  
3. The module normally operates at VB = 24 V, but is able to withstand supply transients up to 30 V.  
February 1994  
4
 
Philips Semiconductors  
Productspecification  
CATV amplifier module  
BGD602  
CHARACTERISTICS  
Bandwidth 40 to 450 MHz; VB = 24 V; Tmb = 35 °C; ZS = ZL = 75 .  
SYMBOL  
PARAMETER  
CONDITIONS  
f = 50 MHz  
MIN.  
18  
MAX.  
19  
UNIT  
dB  
Gp  
power gain  
f = 450 MHz  
18.6  
0.2  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
deg  
dB  
SL  
FL  
slope cable equivalent  
flatness of frequency response  
input return losses  
f = 40 to 450 MHz  
f = 40 to 450 MHz  
f = 40 to 80 MHz  
f = 80 to 160 MHz  
f = 160 to 450 MHz  
f = 40 to 80 MHz  
f = 80 to 160 MHz  
f = 160 to 450 MHz  
f = 50 MHz  
1.8  
±0.3  
+45  
67  
S11  
20  
19  
18  
20  
19  
18  
45  
S22  
output return losses  
S21  
phase response  
CTB  
composite triple beat  
60 channels flat;  
Vo = 46 dBmV;  
measured at 445.25 MHz  
Xmod  
CSO  
cross modulation  
60 channels flat;  
Vo = 46 dBmV;  
measured at 55.25 MHz  
66  
dB  
dB  
composite second order distortion  
60 channels flat;  
Vo = 46 dBmV  
60  
measured at 446.5 MHz  
d2  
Vo  
F
second order distortion  
output voltage  
note 1  
67  
75  
dB  
dim = 60 dB; note 2  
f = 450 MHz  
note 3  
dBmV  
dB  
noise figure  
7
Itot  
total current consumption (DC)  
435  
mA  
Notes  
1. fp = 55.25 MHz; Vp = 46 dBmV;  
fq = 391.25 MHz; Vq = 46 dBmV;  
measured at fp + fq = 446.5 MHz.  
2. Measured according to DIN45004B:  
fp = 440.25 MHz; Vp = Vo;  
fq = 447.25 MHz; Vq = Vo 6 dB;  
fr = 449.25 MHz; Vr = Vo 6 dB;  
measured at fp + fq fr = 438.25 MHz.  
3. The module normally operates at VB = 24 V, but is able to withstand supply transients up to 30 V.  
February 1994  
5
 
Philips Semiconductors  
Productspecification  
CATV amplifier module  
BGD602  
DEFINITIONS  
Data sheet status  
Objective specification  
Preliminary specification  
Product specification  
This data sheet contains target or goal specifications for product development.  
This data sheet contains preliminary data; supplementary data may be published later.  
This data sheet contains final product specifications.  
Limiting values  
Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one or  
more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation  
of the device at these or at any other conditions above those given in the Characteristics sections of the specification  
is not implied. Exposure to limiting values for extended periods may affect device reliability.  
Application information  
Where application information is given, it is advisory and does not form part of the specification.  
LIFE SUPPORT APPLICATIONS  
These products are not designed for use in life support appliances, devices, or systems where malfunction of these  
products can reasonably be expected to result in personal injury. Philips customers using or selling these products for  
use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting from such  
improper use or sale.  
February 1994  
6
 

Peavey Guitar KB A 300 User Manual
Philips CD Player AZ102B User Manual
Philips DVD VCR Combo DVD741VR User Manual
Philips Flat Panel Television 15PT1767 05 User Manual
Philips Projector UPM51 User Manual
Philips Speaker SB7200 User Manual
Phoenix Gold Speaker QX Series User Manual
Pioneer Stereo Receiver AVIC D1 User Manual
Planar Car Video System PX2211 MW User Manual
Polk Audio Network Router LC265I IP User Manual