Pelco DVR C695M QS 12 03 User Manual

Q U I C K S TA R T G U I D E  
DX3100 Series  
Digital Video Recorder  
®
C695M-QS (12/03)  
 
DX3100 SERIES DIGITAL VIDEO RECORDER  
This guide provides basic information for installing, configuring, and using the DX3100 Series digital video recorder. For detailed information, refer to  
the DX3100 Installation/Operation manual.  
HARDWARE INSTALLATION  
After you place the unit in a rack or on a desktop, set the switches and make the connections as listed:  
Set the correct voltage: 115V or 230V.  
Set the video format switch: NTSC or PAL.  
Connect the cameras. Also connect any looping outputs.  
Connect the monitor.  
Connect the power cable.  
Connect alarm inputs and outputs.  
If you will access the unit over a network, connect a network cable to the LAN port.  
If installing Spectra, Esprit, or other PTZ:  
8a Connect the RS-232 to RS-422/RS-485 converter.  
8b Connect power to the converter.  
8c Connect camera control cabling to the converter.  
4
3
2
1
5
6
1
9
2
3
4
5
6
7
8
MON OUT  
IN  
10  
11  
12  
13  
14  
15  
16  
G 1  
2
3
4
G
1
2
NTSC  
PAL  
IN  
OUT ALARM  
VERIFY THAT  
THE VOLTAGE IS  
SET CORRECTLY  
(115V/230V)  
115V  
230V  
LAN  
P/T/Z  
SERIAL  
OUT 1-8  
OUT 9-16  
RC  
DX31 16-XX  
8
a
8
c
7
USA STANDARD  
EUROPEAN STANDARD  
ADAPTER  
RS-232 TO  
RS-422/RS-485  
CONVERTER  
POWER  
ADAPTER  
SPECTRA®  
ESPRIT®  
8
b
Rx-  
Rx-  
Rx+  
Rx+  
DAISY-CHAIN HOOKUP FOR PTZ CAMERAS  
C695M-QS (12/03)  
3
 
FRONT PANEL OPERATION  
NOTE: For complete information about the front panel and the IR remote controller, refer to the DX3100 Installation/Operation manual.  
The buttons for each section below are shaded in the associated figures.  
General  
Power switch (startup and shutdown)  
Toggle on-screen display (OSD)  
Sequence  
Activate multi-screen views: for 1x1, for 2x2, for 3x3, for 4x4 (DX3116)  
Display selected camera (1-8 or 1-16)  
Setup  
Enter and exit setup mode; exit submenus  
NOTE: The default password is 1981.  
Select submenu or edit field  
Field selection and edit: , , , ꢇ  
Edit password (DX3116): buttons 1-9 = numbers 1-9, button 10 = 0  
ᕫᕾ Edit password (DX3108): buttons 1-8 = numbers 1-8,  
button = number 9, button = number 0  
Playback  
ᕫᕵ Enter and exit playback mode  
ᕫᕶ VCR-style controls for video playback  
ᕫᕷ Display event list  
ᕫᕸ Field selection/edit: , , , , ENTER  
ᕫᕹ Display video from selected camera (1-8 or 1-16)  
ᕫᕺ Save image to floppy disk  
PTZ  
19 20  
17  
18  
21 22 23  
ᕫᕻ Enter and exit PTZ mode  
ᕫᕼ Toggle on-screen display (OSD)  
ᕫᕽ Zoom control: ZM WIDE, ZM TELE  
ᕬᕾ PTZ directional movement: , , , , , , , ꢃ  
ᕬᕵ Enter and exit focus and iris controls  
ᕬᕶ Focus controls: FOCUS NEAR, FOCUS FAR  
ᕬᕷ Iris controls: IRIS CLOSE, IRIS OPEN  
Z
WIDE  
Z
FOCUS  
FN  
FDD  
P/T/Z OSD  
EVENT  
SEQ  
FOCUS  
NEAR  
ZM  
WIE  
ZM  
TELE  
FDD  
P/T/Z OSD  
EVENT  
SEQ  
FOCUS  
NEAR  
FOCUS  
FAR  
TELE  
F
FAR  
IRIS  
CLOSE  
IRIS  
OPEN  
IRIS  
CLOSE  
IRIS  
OPEN  
ENTER  
ENTER  
PLAYBACK  
SETUP  
PLAYBACK  
SETUP  
POWER  
POWER  
RETURN  
RETURN  
RETURN  
RETURN  
4
C695M-QS (12/03)  
 
CONFIGURATION  
To configure the DX3100:  
Press SETUP.  
Use the camera buttons to enter the four-digit password. The default is 1981. The setup menu  
appears.  
Change the default DX3100 settings:  
a. Select RECORDER SETUP on the setup menu and then press ENTER.  
b. Change any of the following DX3100 settings:  
IMAGE SIZE: The default is 352 X 240.  
IMAGE RATE: The default is either 8 ips (DX3108) or 16 ips (DX3116).  
TIME/DATE SET: The default is set at the factory.  
DAYLIGHT SAVING: The default is US.  
PTZ PROTOCOL: The default is NONE.  
c. Press SETUP to return to the setup menu.  
Configure the settings for each camera:  
a. Select CAMERA SETUP on the setup menu and then press ENTER.  
b. Press (down arrow) to select the camera and press ENTER.  
c. Change any of the following default camera settings:  
NOTE: Select MANUAL to change any setting under RECORD PARAMETER.  
CAMERA NAME: The default name for each channel: CH1 to CH16.  
RECORD TIME: The default is 0 to 24.  
IMAGE QUALITY: The default is 70.  
MOTION SENSITIVITY: The default is 100.  
PTZ RX ADDRESS: The default is 0.  
d. Press SETUP to return to the setup menu.  
Configure the network settings (optional):  
a. Select NETWORK SETUP on the setup menu and then press ENTER.  
b. Enter the network address information for the DX3100: IP ADDRESS, SUBNET MASK  
and GATEWAY.  
NOTE: You may also set the network password for this DX3100.  
c. Press SETUP to return to the setup menu.  
Press SETUP to exit the setup menu.  
C695M-QS (12/03)  
5
 
SETTING SYSTEM DATE AND TIME  
Press SETUP.  
Use the camera buttons to enter the four-digit password. The default is 1981. The setup menu appears.  
Select RECORDER SETUP and then press ENTER.  
Update the daylight saving time setting (optional). The default is US.  
a. Select DAYLIGHT SAVING and then press ENTER.  
b. To disable daylight saving time processing, press (up arrow) or (down arrow) to select NONE and then press ENTER.  
c. To enable daylight saving time processing for a different country, press (up arrow) or (down arrow) to select the country and then  
press ENTER.  
Select the time format (optional):  
a. Select TIME FORMAT and then press ENTER.  
b. Press (up arrow) or (down arrow) to select AM/PM or 24HR.  
c. Press ENTER.  
Set the system date and time:  
a. Select TIME/DATE SET and then press ENTER.  
b. Press (right arrow) to select a field to change: day, month, day, year, AM/PM, hours, minutes, or seconds.  
c. Press (up arrow) or (down arrow) to change the field value.  
d. When the date and time are correct, press ENTER.  
Press SETUP to return to the setup menu.  
Press SETUP again to exit the setup menu.  
6
C695M-QS (12/03)  
 
DX3100RX REMOTE SITE SOFTWARE  
NOTE: Before installing this software, refer to the DX3100 Series Remote Site Software manual for minimum system requirements.  
NOTE: This Quick Start Guide is written for installers who are familiar with the Windows® operating system.  
Installation  
Insert the Remote Site Software CD that came with the DX3100.  
Follow the on-screen prompts, specifying default program folder.  
Restart the computer.  
Configuration  
Launch the Remote Site Software:  
Start > Program > DX3100RX > DX3100RX v1.0.  
Click OK on the Input password screen. You can add a password later.  
Create a site for the DX3100:  
a. Click CONNECT. The Site/File Open screen appears.  
b. Click Add. The Connection Property (New) screen appears.  
c. Do the following:  
Site Name: Enter the site name for this DX3100. It appears on the screen when you access the site.  
Server IP: Enter the network address for the DX3100. It must match the IP ADDRESS field on the NETWORK SETUP screen on  
the DX3100.  
User ID: Enter dx3100 (case-sensitive).  
Password: Enter the password from the PASSWORD field on the NETWORK SETUP screen on the DX3100.  
Camera: Specify the cameras to display.  
d. Click OK.  
Select Live or Remote Playback on the Site/File Open screen. Then click OK. The site video (live or playback) begins to display.  
Operation  
Launch the Remote Site Software:  
Start > Program > DX3100RX > DX3100RX v1.0.  
Click OK on the Input password screen. You can add a password later.  
Click CONNECT. The Site/File Open screen appears.  
Select the DX3100 to view.  
Select Live or Remote Playback on the Site/File Open screen. Then click OK. The site video (live or playback) begins to display.  
NOTE: To reconnect automatically when a network error occurs, select Try Reconnecting Continuously for Network or Server Error on the  
Network Setup screen.  
Pelco, the Pelco logo, Spectra, and Esprit are registered trademarks of Pelco in the United States and other countries.  
Windows is a registered trademark of Microsoft Corporation in the United States and other countries.  
© Copyright 2003, Pelco. All rights reserved.  
C695M-QS (12/03)  
7
 
World Headquarters  
3500 Pelco Way  
Clovis, California 93612 USA  
USA & Canada  
Tel: 800/289-9100  
Fax: 800/289-9150  
International  
Tel: 1-559/292-1981  
Fax: 1-559/348-1120  
ISO9001  
Orangeburg, New York Las Vegas, Nevada Eindhoven, The Netherlands Wokingham, United Kingdom Montreal, Canada  
Singapore  
 

Peavey Musical Instrument Amplifier 208s User Manual
Philips DVD VCR Combo DVD741VR User Manual
Philips Hair Clippers CC5060 User Manual
Philips Portable DVD Player PET988 12 User Manual
Pioneer Cassette Player CT W603RS User Manual
Planet Technology Network Card WNL U554 User Manual
Polaroid Video Games TDX 142 User Manual
Poulan Blower PPB200 LE User Manual
Prima Donna Designs Washer Dryer LPR 721 User Manual
PYLE Audio Car Stereo System PLCD42 User Manual