How to obtain meaningful blood pressure readings  
General  
Caution  
• The OMRON RX-3 is not suitable for measuring  
the frequency of cardiac pacemakers.  
• Consult your doctor during pregnancy, arrhythmia  
and arteriosclerosis.  
• Operating temperature between 10°C and 40°C.  
• Operating environment must be free from  
excessive vibrations, shocks, magnetic fields,  
electrical noise, etc.  
• Avoid eating, drinking (alcohol), smoking, sport  
and taking a bath before measurement.  
• Be calm and relaxed before and during  
measurement.  
• Stay out of sunlight during measuring.  
• Keep portable phones 5 meters away during  
measurement.  
• Do not wrap the cuff other than around your wrist.  
• Do not drop the OMRON RX-3.  
You should never change the dose of medicines  
prescribed by your doctor.  
Tips for use  
• Check your blood pressure at least twice a day  
(before breakfast, after work).  
• Do not measure your blood pressure while you  
are in a vehicle.  
• Always measure on the same wrist.  
• Wrap the wrist cuff around your wrist before start  
of measurement.  
 
2
RX-3 English  
Overview  
A
C
D
B
E
A Display  
D On/Off button  
B Wrist Cuff  
E Battery Compartment  
C Memory Recall button  
 
3
RX-3 English  
Preparation  
Insert batteries  
1 Open the battery compartment.  
2 Insert two batteries in the battery compartment.  
Caution! Use two identical 1.5V alkaline  
batteries type AAA LR03!  
3 Close the battery compartment.  
 
4
RX-3 English  
Fit wrist cuff  
Caution! Do not press On/Off button when the wrist cuff is not wrapped around the wrist!  
1 Bare your wrist.  
2 Put the monitor on the inner side of your wrist.  
Caution! Push up your sleeve: avoid constricting  
the blood flow!  
M
3 Hold the end of the wrist cuff and wrap it around  
your wrist.  
Note: attach the monitor upside down for reliable  
measurement at your right wrist.  
Caution! Be sure the wrist cuff fits closely; do  
 
not pinch your arm!  
5
RX-3 English  
Operation  
J
F
SYSmmHg  
MEMORY  
K
C
D
G
L
DI AmmHg  
PULSE/min  
M
H
P
N
Control functions  
C Memory Recall button  
D On/Off button  
Measurement  
F Systolic blood pressure in mmHg.  
G Monitor blood pressure: flash - measurement  
takes place, light up - finish measurement.  
H Diastolic blood pressure in mmHg.  
J Memory display: values in memory.  
K Memory position: 1 to 28.  
L Inflation: wrist cuff inflates and measurement starts.  
M Deflation: wrist cuff deflates and measurement  
finishes.  
N Battery exhausted: batteries are weak/exhausted.  
 
P Pulse: heartbeats per minute.  
6
RX-3 English  
Caution! Allow an interval of at least three minutes between two successive measurements!  
SYSmmHg  
MEMORY  
DI AmmHg  
PULSE/min  
1 Sit comfortably at a table with your feet flat on the  
Caution! The OMRON RX-3 should always be at  
heart height during measurement. Usage of the hard  
case assures the right position of the OMRON RX-3!  
floor and put your arm against the hard case.  
SYSmmHg  
MEMORY  
DI AmmHg  
PULSE/min  
2 Press On/Off button to start measurement.  
Caution ! Sit still, do not move, do not speak and  
 
The OMRON RX-3 measures during inflation!  
do not touch the OMRON RX-3!  
7
RX-3 English  
Read display  
SYSmmHg  
MEMORY  
SYSmmHg  
MEMORY  
DI AmmHg  
PULSE/min  
DI AmmHg  
PULSE/min  
1 Read the values of blood pressure and pulse from the display.  
Note: Display shows alternately blood pressures and heartbeats.  
SYSmmHg  
MEMORY  
DI AmmHg  
PULSE/min  
 
2 Note values in your personal blood pressure pass. 3 Press On/Off button to turn off power.  
8
RX-3 English  
Memory  
Recall previous values  
K Memory position of latest and previous values.  
K
SYSmmHg  
MEMORY  
SYSmmHg  
MEMORY  
DI AmmHg  
PULSE/min  
DI AmmHg  
PULSE/min  
1 Press Memory Recall button to turn on power. Note: Display shows alternately blood pressures and heartbeats.  
K
SYSmmHg  
MEMORY  
SYSmmHg  
MEMORY  
DI AmmHg  
PULSE/min  
DI AmmHg  
PULSE/min  
2 Press Memory Recall button for latest and previous values. Press On/Off button to turn off power.  
 
Note: Display shows alternately blood pressures and heartbeats.  
9
RX-3 English  
Erase memory  
SYSmmHg  
MEMORY  
SYSmmHg  
MEMORY  
DI AmmHg  
PULSE/min  
DI AmmHg  
PULSE/min  
1 Press Memory Recall button to turn on power.  
2 Press Memory Recall button and simultaneously  
On/Off button to erase memory.  
Caution! All stored values will be erased!  
Press On/Off button to turn off power.  
 
10  
RX-3 English  
Storage  
• Store the OMRON RX-3 in the hard case in a dry, closed place with a temperature between -20°C and 60°C.  
• Remove the batteries if you not intend to use the OMRON RX-3 for 3 months or more.  
Faults: causes and rectifications  
Fault  
Cause  
Rectification  
Correct reading not possible  
Movement, sound vibration,  
weak pulse  
Wait for at least three minutes to  
repeat measurement  
Display  
alkaline  
Low voltage  
empty  
Batteries weak/exhausted  
Wrong working method  
Fit two new identical 1.5V  
batteries type AAA LR03  
Inexplicable values  
Follow instructions, repeat  
measurement  
 
11  
RX-3 English  
Maintenance and spare parts  
Replace batteries  
• Use a soft, slightly moistened cloth to clean the  
OMRON RX-3.  
• Remove the battery out of the battery  
compartment and insert two new identical 1.5V  
alkaline batteries type AAA LR03 batteries.  
Spare parts  
Caution! Do not use petrol, thinners or similar  
solvents!  
• Use a soft, moistened cloth and soap to clean the  
wrist cuff.  
• Due to high company quality standards, OMRON  
considers the main unit as a non-serviceable part  
because the need for proper calibration after  
replacement of high tech components.  
• If the cuff needs to be replaced have this done by  
an authorised expert. Consult your OMRON  
retailer or OMRON distributor as mentioned on  
the packaging.  
Caution! Do not wash the wrist cuff!  
Caution! Do not use petrol, thinners or similar  
solvents!  
• Do not carry out repairs of any kind yourself. If a  
defect occurs consult your OMRON retail outlet or  
distributor as mentioned on the packaging.  
Calibration  
• It is recommended to have the OMRON RX-3  
inspected every two years to ensure correct  
function and accuracy. Consult your OMRON  
retail outlet or OMRON distributor as mentioned  
on the packaging.  
Attention! Disposal of batteries  
and the OMRON RX-3 should be  
carried out in accordance with the  
national regulations for the  
disposal of electronic products.  
 
12  
RX-3 English  
Technical Data  
Product name  
Model  
Display  
OMRON RX-3 wrist blood pressure monitor  
HEM-640-E  
Digital LCD  
Measuring range  
Accuracy  
Inflation  
Blood pressure: 0 - 299 mmHg / Pulse: 40 - 180 beats/minute  
Blood pressure: ± 3 mmHg / Pulse: ± 5% of display reading  
Automatic by electric pump  
Deflation  
Automatic rapid deflation system  
Pressure sensor (capacitive)  
Oscilliometric  
28 Measurements  
Pressure detection  
Measuring method  
Memory  
Power supply  
Battery life  
2 x 1.5V Alkaline batteries (LR03) AAA  
New batteries will last for approx. 300 measurements  
+10°C to +40°C / 30% to max. 85% relative humidity  
Free from excessive vibrations, shocks, magnetic fields, electrical noise, etc.  
-20°C to +60°C /10% to max. 95% relative humidity  
Approx. 140/160 g ex-/including batteries  
Approx. 47 mm (W) x 71 mm (H) x 79 mm (D)  
Approx. 13.5 cm to 19.5 cm  
Operating temperature /humidity  
Operating environment  
Storage temperature / humidity  
Weight  
Outer dimensions  
Wrist circumference  
Accessories  
Instruction manual, guarantee card, blood pressure pass,  
2 alkaline batteries, storage box  
Note  
Subject to technical modification without prior notice  
= Type B  
0197  
Manufacturer  
EU-representative  
OMRON HEALTHCARE CO., LTD. Japan  
OMRON HEALTHCARE EUROPE B.V., Kruisweg 577, NL-2132 NA Hoofddorp  
Made in China  
This device fulfils the provisions of the EC directive 93/42/EEC (Medical Device Directive). This blood pressure monitor is designed  
according to the European standard EN1060, Non-invasive sphygmomanometers Part 1: General Requirements and Part 3:  
Supplementary requirements for electromechanical blood pressure measuring systems.  
This OMRON product is produced under the strict quality system of OMRON HEALTHCARE CO., LTD., Japan. The Core component for  
 
OMRON blood pressure monitors, which is the Pressure Sensor, is produced in Japan.  
13  
RX-3 English  
General information about blood pressure  
Blood circulation  
The blood circulation is responsible for supplying the  
body with oxygen. Blood pressure is the pressure  
exerted on the arteries.  
Systolic blood pressure  
(mmHg)  
The systolic blood pressure value (higher pressure  
or top value) represents the blood pressure  
produced by contraction of the heart muscle.  
Severe hypertension  
Moderate hypertension  
Mild hypertension  
Normal systolic value  
180  
160  
140  
130  
120  
The diastolic blood pressure value (lower pressure  
or lower value) represents the blood pressure  
produced by relaxation of the heart muscle.  
Normal blood  
pressure  
Optimal blood  
Classification of blood pressure  
pressure  
Diastolic  
blood  
pressure  
The World Health Organisation (WHO) and the  
International Society of Hypertension (ISH)  
developed the blood pressure classification. This  
classification is based on the blood pressure values  
measured while sitting on a chair in the outpatient  
department of a hospital.  
(target value)  
80  
85  
90  
100 110  
(mmHg)  
According to the blood pressure classification by the WHO/ISH.  
 
14  
RX-3 English  
Health and blood pressure  
• Stress and emotional upset  
• Excessive consumption of salt  
• Lack of physical exercise  
The incidence of hypertension increases with age. In  
addition, a lack of exercise, excess body fat and high  
levels of cholesterol (LDL), which sticks to the inside  
in blood vessels, reduces elasticity of these vessels.  
Hypertension accelerates arterial sclerosis which  
can lead to very serious conditions such as stroke  
and myocardial infarction. For these reasons it is  
very important to know whether the blood pressure  
is within a healthy range. Blood pressure fluctuates  
from minute to minute, throughout the day. Therefore  
it is essential to take regular measurements to help  
you identify an average blood pressure.  
• Genetic/hereditary predisposition  
• Underlying illnesses, such as kidney disorders or  
endocrine disturbance  
Blood pressure measurement  
Measuring your blood pressure daily enables you to  
recognize high blood pressure at an early stage and  
obtain medical treatment.  
The oscillometric method of measurement  
determines your blood pressure by measuring the  
pressure fluctuations caused by the pulse waves.  
Symptoms of high blood pressure  
High blood pressure can go unnoticed for a long  
time, since it does not cause noticeable symptoms.  
The following are all possible causes of abnormally  
high blood pressure:  
Since your blood pressure fluctuates within a day (see  
graphic next page), you should always measure it at the  
same time each day to ensure that the measurements  
are genuinely comparable. At the doctor’s surgery,  
nervousness and tension may cause your blood  
pressure to be higher than in familiar circumstances at  
home. This is known as “White Coat Hypertension”.  
• Overweight  
• High cholesterol level  
• Smoking  
 
• Excessive alcohol consumption  
15  
RX-3 English  
Treatment of high blood pressure  
If your blood pressure reaches upper values of 140 -  
160 mmHg and lower values of 90 - 95 mmHg in  
repeated measurements over several days, you  
should consult your doctor for detailed medical  
examination. You can assist the treatment  
prescribed by your doctor in the following ways:  
• Loose weight and lower your cholesterol level by  
reducing the calories and fat in your diet. Cut down  
on animal fats and eat more fruit and vegetables.  
• Reduce the consumption of alcohol.  
• Reduce the intake of salt: the German League  
for Combating High Blood Pressure recommends  
six grams of salt per day (i.e. one teaspoon) on  
average.  
Upper curve: systolic blood pressure  
Lower curve: diastolic blood pressure  
200  
150  
100  
50  
6
12  
18  
24  
Time of day  
• Stop smoking.  
Take regular exercise.  
Example: fluctuation within a day (male, 35 years old)  
• Monitor your blood pressure.  
 
16  
OMRON HEALTHCARE CO., LTD.  
24, Yamanouchi Yamanoshita-cho, Ukyo-ku  
Kyoto, 615-0084 Japan  
Manufacturer  
OMRON HEALTHCARE EUROPE B.V.  
Kruisweg 577, 2132 NA Hoofddorp, The Netherlands  
EC  
REP  
EU-representative  
Production facility  
OMRON DALIAN CO., LTD.  
Economic & Technical Development Zone, Dalian 116600, China  
OMRON HEALTHCARE UK LTD.  
Opal Drive, Fox Milne, Milton Keynes MK15 0DG, United Kingdom  
OMRON Medizintechnik Handelsgesellschaft mbH  
John-Deere-Str. 81a, 68163 Mannheim, Germany  
Subsidiary  
OMRON SANTÉ FRANCE SAS  
14, rue de Lisbonne, 93561 Rosny-sous-Bois Cedex, France  
Made in China  
 

Miele Clothes Dryer T 650 C User Manual
Nady Systems Speaker System PS112 User Manual
NordicTrack Home Gym 83128353 User Manual
Optimus Cassette Player SCP 98 User Manual
Optoma Technology Projector PT100 User Manual
Oster Juicer 124828 User Manual
Palsonic Flat Panel Television TFTV421080HD User Manual
Panasonic Laptop Docking Station 71700140 User Manual
Paradyne Modem 7110 SNMP User Manual
Patterson Kelley Water Heater Compact Water Heater User Manual