RX-3
Blood Pressure Monitor
Instruction manual
Gebrauchsanweisung
Gebruiksaanwijzing
page
Seite 17
pagina 33
1
Mode d’emploi
Manuale de instructone
Manual de instrucciones
page 49
pagina 65
pagina 81
IM-HEM-640-E-01-08/08
1628088-1E
RX-3 English
How to obtain meaningful blood pressure readings
General
Caution
• The OMRON RX-3 is not suitable for measuring
the frequency of cardiac pacemakers.
• Consult your doctor during pregnancy, arrhythmia
and arteriosclerosis.
• Operating temperature between 10°C and 40°C.
• Operating environment must be free from
excessive vibrations, shocks, magnetic fields,
electrical noise, etc.
• Avoid eating, drinking (alcohol), smoking, sport
and taking a bath before measurement.
• Be calm and relaxed before and during
measurement.
• Stay out of sunlight during measuring.
• Keep portable phones 5 meters away during
measurement.
• Do not wrap the cuff other than around your wrist.
• Do not drop the OMRON RX-3.
• You should never change the dose of medicines
prescribed by your doctor.
Tips for use
• Check your blood pressure at least twice a day
(before breakfast, after work).
• Do not measure your blood pressure while you
are in a vehicle.
• Always measure on the same wrist.
• Wrap the wrist cuff around your wrist before start
of measurement.
2
RX-3 English
Overview
A
C
D
B
E
A Display
D On/Off button
B Wrist Cuff
E Battery Compartment
C Memory Recall button
3
RX-3 English
Preparation
Insert batteries
1 Open the battery compartment.
2 Insert two batteries in the battery compartment.
Caution! Use two identical 1.5V alkaline
batteries type AAA LR03!
3 Close the battery compartment.
4
RX-3 English
Fit wrist cuff
Caution! Do not press On/Off button when the wrist cuff is not wrapped around the wrist!
1 Bare your wrist.
2 Put the monitor on the inner side of your wrist.
Caution! Push up your sleeve: avoid constricting
the blood flow!
M
3 Hold the end of the wrist cuff and wrap it around
your wrist.
Note: attach the monitor upside down for reliable
measurement at your right wrist.
Caution! Be sure the wrist cuff fits closely; do
not pinch your arm!
5
RX-3 English
Operation
J
F
SYSmmHg
MEMORY
K
C
D
G
L
DI AmmHg
PULSE/min
M
H
P
N
Control functions
C Memory Recall button
D On/Off button
Measurement
F Systolic blood pressure in mmHg.
G Monitor blood pressure: flash - measurement
takes place, light up - finish measurement.
H Diastolic blood pressure in mmHg.
J Memory display: values in memory.
K Memory position: 1 to 28.
L Inflation: wrist cuff inflates and measurement starts.
M Deflation: wrist cuff deflates and measurement
finishes.
N Battery exhausted: batteries are weak/exhausted.
P Pulse: heartbeats per minute.
6
RX-3 English
Caution! Allow an interval of at least three minutes between two successive measurements!
SYSmmHg
MEMORY
DI AmmHg
PULSE/min
1 Sit comfortably at a table with your feet flat on the
Caution! The OMRON RX-3 should always be at
heart height during measurement. Usage of the hard
case assures the right position of the OMRON RX-3!
floor and put your arm against the hard case.
SYSmmHg
MEMORY
DI AmmHg
PULSE/min
2 Press On/Off button to start measurement.
Caution ! Sit still, do not move, do not speak and
The OMRON RX-3 measures during inflation!
do not touch the OMRON RX-3!
7
RX-3 English
Read display
SYSmmHg
MEMORY
SYSmmHg
MEMORY
DI AmmHg
PULSE/min
DI AmmHg
PULSE/min
1 Read the values of blood pressure and pulse from the display.
Note: Display shows alternately blood pressures and heartbeats.
SYSmmHg
MEMORY
DI AmmHg
PULSE/min
2 Note values in your personal blood pressure pass. 3 Press On/Off button to turn off power.
8
RX-3 English
Memory
Recall previous values
K Memory position of latest and previous values.
K
SYSmmHg
MEMORY
SYSmmHg
MEMORY
DI AmmHg
PULSE/min
DI AmmHg
PULSE/min
1 Press Memory Recall button to turn on power. Note: Display shows alternately blood pressures and heartbeats.
K
SYSmmHg
MEMORY
SYSmmHg
MEMORY
DI AmmHg
PULSE/min
DI AmmHg
PULSE/min
2 Press Memory Recall button for latest and previous values. Press On/Off button to turn off power.
Note: Display shows alternately blood pressures and heartbeats.
9
RX-3 English
Erase memory
SYSmmHg
MEMORY
SYSmmHg
MEMORY
DI AmmHg
PULSE/min
DI AmmHg
PULSE/min
1 Press Memory Recall button to turn on power.
2 Press Memory Recall button and simultaneously
On/Off button to erase memory.
Caution! All stored values will be erased!
Press On/Off button to turn off power.
10
RX-3 English
Storage
• Store the OMRON RX-3 in the hard case in a dry, closed place with a temperature between -20°C and 60°C.
• Remove the batteries if you not intend to use the OMRON RX-3 for 3 months or more.
Faults: causes and rectifications
Fault
Cause
Rectification
Correct reading not possible
Movement, sound vibration,
weak pulse
Wait for at least three minutes to
repeat measurement
Display
alkaline
Low voltage
empty
Batteries weak/exhausted
Wrong working method
Fit two new identical 1.5V
batteries type AAA LR03
Inexplicable values
Follow instructions, repeat
measurement
11
RX-3 English
Maintenance and spare parts
Replace batteries
• Use a soft, slightly moistened cloth to clean the
OMRON RX-3.
• Remove the battery out of the battery
compartment and insert two new identical 1.5V
alkaline batteries type AAA LR03 batteries.
Spare parts
Caution! Do not use petrol, thinners or similar
solvents!
• Use a soft, moistened cloth and soap to clean the
wrist cuff.
• Due to high company quality standards, OMRON
considers the main unit as a non-serviceable part
because the need for proper calibration after
replacement of high tech components.
• If the cuff needs to be replaced have this done by
an authorised expert. Consult your OMRON
retailer or OMRON distributor as mentioned on
the packaging.
Caution! Do not wash the wrist cuff!
Caution! Do not use petrol, thinners or similar
solvents!
• Do not carry out repairs of any kind yourself. If a
defect occurs consult your OMRON retail outlet or
distributor as mentioned on the packaging.
Calibration
• It is recommended to have the OMRON RX-3
inspected every two years to ensure correct
function and accuracy. Consult your OMRON
retail outlet or OMRON distributor as mentioned
on the packaging.
Attention! Disposal of batteries
and the OMRON RX-3 should be
carried out in accordance with the
national regulations for the
disposal of electronic products.
12
RX-3 English
Technical Data
Product name
Model
Display
OMRON RX-3 wrist blood pressure monitor
HEM-640-E
Digital LCD
Measuring range
Accuracy
Inflation
Blood pressure: 0 - 299 mmHg / Pulse: 40 - 180 beats/minute
Blood pressure: ± 3 mmHg / Pulse: ± 5% of display reading
Automatic by electric pump
Deflation
Automatic rapid deflation system
Pressure sensor (capacitive)
Oscilliometric
28 Measurements
Pressure detection
Measuring method
Memory
Power supply
Battery life
2 x 1.5V Alkaline batteries (LR03) AAA
New batteries will last for approx. 300 measurements
+10°C to +40°C / 30% to max. 85% relative humidity
Free from excessive vibrations, shocks, magnetic fields, electrical noise, etc.
-20°C to +60°C /10% to max. 95% relative humidity
Approx. 140/160 g ex-/including batteries
Approx. 47 mm (W) x 71 mm (H) x 79 mm (D)
Approx. 13.5 cm to 19.5 cm
Operating temperature /humidity
Operating environment
Storage temperature / humidity
Weight
Outer dimensions
Wrist circumference
Accessories
Instruction manual, guarantee card, blood pressure pass,
2 alkaline batteries, storage box
Note
Subject to technical modification without prior notice
= Type B
0197
Manufacturer
EU-representative
OMRON HEALTHCARE CO., LTD. Japan
OMRON HEALTHCARE EUROPE B.V., Kruisweg 577, NL-2132 NA Hoofddorp
Made in China
This device fulfils the provisions of the EC directive 93/42/EEC (Medical Device Directive). This blood pressure monitor is designed
according to the European standard EN1060, Non-invasive sphygmomanometers Part 1: General Requirements and Part 3:
Supplementary requirements for electromechanical blood pressure measuring systems.
This OMRON product is produced under the strict quality system of OMRON HEALTHCARE CO., LTD., Japan. The Core component for
OMRON blood pressure monitors, which is the Pressure Sensor, is produced in Japan.
13
RX-3 English
General information about blood pressure
Blood circulation
The blood circulation is responsible for supplying the
body with oxygen. Blood pressure is the pressure
exerted on the arteries.
Systolic blood pressure
(mmHg)
The systolic blood pressure value (higher pressure
or top value) represents the blood pressure
produced by contraction of the heart muscle.
Severe hypertension
Moderate hypertension
Mild hypertension
Normal systolic value
180
160
140
130
120
The diastolic blood pressure value (lower pressure
or lower value) represents the blood pressure
produced by relaxation of the heart muscle.
Normal blood
pressure
Optimal blood
Classification of blood pressure
pressure
Diastolic
blood
pressure
The World Health Organisation (WHO) and the
International Society of Hypertension (ISH)
developed the blood pressure classification. This
classification is based on the blood pressure values
measured while sitting on a chair in the outpatient
department of a hospital.
(target value)
80
85
90
100 110
(mmHg)
According to the blood pressure classification by the WHO/ISH.
14
RX-3 English
Health and blood pressure
• Stress and emotional upset
• Excessive consumption of salt
• Lack of physical exercise
The incidence of hypertension increases with age. In
addition, a lack of exercise, excess body fat and high
levels of cholesterol (LDL), which sticks to the inside
in blood vessels, reduces elasticity of these vessels.
Hypertension accelerates arterial sclerosis which
can lead to very serious conditions such as stroke
and myocardial infarction. For these reasons it is
very important to know whether the blood pressure
is within a healthy range. Blood pressure fluctuates
from minute to minute, throughout the day. Therefore
it is essential to take regular measurements to help
you identify an average blood pressure.
• Genetic/hereditary predisposition
• Underlying illnesses, such as kidney disorders or
endocrine disturbance
Blood pressure measurement
Measuring your blood pressure daily enables you to
recognize high blood pressure at an early stage and
obtain medical treatment.
The oscillometric method of measurement
determines your blood pressure by measuring the
pressure fluctuations caused by the pulse waves.
Symptoms of high blood pressure
High blood pressure can go unnoticed for a long
time, since it does not cause noticeable symptoms.
The following are all possible causes of abnormally
high blood pressure:
Since your blood pressure fluctuates within a day (see
graphic next page), you should always measure it at the
same time each day to ensure that the measurements
are genuinely comparable. At the doctor’s surgery,
nervousness and tension may cause your blood
pressure to be higher than in familiar circumstances at
home. This is known as “White Coat Hypertension”.
• Overweight
• High cholesterol level
• Smoking
• Excessive alcohol consumption
15
RX-3 English
Treatment of high blood pressure
If your blood pressure reaches upper values of 140 -
160 mmHg and lower values of 90 - 95 mmHg in
repeated measurements over several days, you
should consult your doctor for detailed medical
examination. You can assist the treatment
prescribed by your doctor in the following ways:
• Loose weight and lower your cholesterol level by
reducing the calories and fat in your diet. Cut down
on animal fats and eat more fruit and vegetables.
• Reduce the consumption of alcohol.
• Reduce the intake of salt: the German League
for Combating High Blood Pressure recommends
six grams of salt per day (i.e. one teaspoon) on
average.
Upper curve: systolic blood pressure
Lower curve: diastolic blood pressure
200
150
100
50
6
12
18
24
Time of day
• Stop smoking.
• Take regular exercise.
Example: fluctuation within a day (male, 35 years old)
• Monitor your blood pressure.
16
OMRON HEALTHCARE CO., LTD.
24, Yamanouchi Yamanoshita-cho, Ukyo-ku
Kyoto, 615-0084 Japan
Manufacturer
OMRON HEALTHCARE EUROPE B.V.
Kruisweg 577, 2132 NA Hoofddorp, The Netherlands
EC
REP
EU-representative
Production facility
OMRON DALIAN CO., LTD.
Economic & Technical Development Zone, Dalian 116600, China
OMRON HEALTHCARE UK LTD.
Opal Drive, Fox Milne, Milton Keynes MK15 0DG, United Kingdom
OMRON Medizintechnik Handelsgesellschaft mbH
John-Deere-Str. 81a, 68163 Mannheim, Germany
Subsidiary
OMRON SANTÉ FRANCE SAS
14, rue de Lisbonne, 93561 Rosny-sous-Bois Cedex, France
Made in China
|