Numark Industries Stereo Amplifier NPA3300 NPA6600 User Manual |
®
Professional Disc Jockey Products
NPA3300/NPA6600
PROFESSIONAL AMPLIFIER
OPERATING MANUAL
©2000
Industries
NPA3300-NPA6600
WARNING: To reduce the risk of fire or electrical shock,
do not expose this appliance to rain or moisture.
Electrical equipment should NEVER be kept or stored in
damp environments.
Unpacking / Setup: Please check your amplifier for any
damage after unpacking (before connecting) and contact
your dealer in case of any related complaints. Take care
of choosing your installation place and the correct AC
connection. If built into a case, be aware that the depth
and the weight of the amplifier does require an additional
fixing on the backside or the use of rack shelf supports.
Never mount the amplifier in a rack just by fixing it on the
front plate - we can show no responsibility for damage
on the rack or the amplifier in this case.
SERVICE INSTRUCTIONS
•
•
Disconnect power cord before servicing
Replace critical components
with factory parts or recommended
equivalents
only
•
For AC line powered units - Before
Always try to separate low level cables (input cables)
and high level cables (AC net and speaker outputs) to
avoid interference.
returning repaired unit to user, use an
ohmmeter to measure from both AC plug
blades to all exposed metallic parts. The
resistance should be no more than
100,000ohms.
DOUBLE INSULATED - When
servicing use only identical
replacement parts
Check the total maximum power of
your AC wall outlet if you connect
several units to one wall outlet and
avoid to overload the wall outlet,
which could cause fire.
For 220-volt use in USA, use NEMA style 220-volt plug.
For other countries use proper plug for local outlet.
Health Advice: This unit produces and absorbs
electromagnetic radiation. The strength of radiation and
the sensitivity for disturbing interference matches the CE
requirements. A corresponding sign is printed on the
backside of the unit. Any change or modification may
affect the behavior of the unit concerning
electromagnetic radiation, with the CE requirements
eventually not to be met any more. The manufacturer
takes no responsibility in this case.
Please record the serial number of your unit as shown on the back of the chassis as well as the
name of the dealer from whom you purchased the unit. Retain this information and your original
purchase receipt for your records. Please return the enclosed warranty card to register unit with us.
MODEL: __________________________ PURCHASED FROM:_________________________
SERIAL NUMBER:___________________ DATE OF PURCHASE:________________________
- The Leader in DJ Technology
©2000 Numark Industries
- 3 -
NPA3300-NPA6600
®
NPA3300/NPA6600
PROFESSIONAL AMPLFIER
CONGRATULATIONS...
Thank you for choosing a NUMARK power amplifier. These units
are designed to provide a good combination of power, audio clarity, and
reliable operation. The basic circuit has been kept as simple as possible
to reduce the amount of components, thereby shortening the signal path,
coloration and the chance of component failure. However, we opted to
add what we regard as essential protection against overheating, short
circuits and power on transients.
An efficient heat dissipation system, comprising a high surface area
heatsink coupled with one or two fans (depending on power rating of
amp), ensures quiet and reliable cooling.
The sound quality and sturdy construction of the makes these amps
ideal for a multitude of amplification tasks, from installations, mobile DJs,
home studios, houses of worship and touring bands.
Since all of the amplifiers are similar in operation, this manual
serves for all models. Please take the time to read this manual before
connecting and operating your unit, as there is important information
contained within.
- The Leader in DJ Technology
©2000 Numark Industries
- 4 -
NPA3300-NPA6600
Front Panel Diagram
2
3
6
5
4
1
1. Power Switch- Press the upper side to turn amplifier on; press the lower side to turn the
unit off.
2. Status LEDs- The red Standby LED will light when the amplifier is turned on. It will stay lit
about 3 seconds while the amplifier circuits stabilize. After that, the red LED will turn off and
the green Normal LED will glow that amplifier is ready to operate.
3. Level controls- Rotate controls clockwise to increase volume.
4. Signal indicators- Light up when the signal input provides greater then 0.2 watts output.
5. Over indicators- Light up when the input signal levels exceed maximum output and
clipping occurs. Consistent lighted of these LEDs can cause both amplifier and speaker
damage. Always avoid clipping.
6. Protect indicators- Light up when one of the built-in protection circuits is activated.
- The Leader in DJ Technology
©2000 Numark Industries
- 5 -
NPA3300-NPA6600
Rear Panel Diagram
8
13
7
10
9
12
11
14
7. Unbalanced inputs- Connect mixer outputs with ¼” input plugs for right and left channels.
8. Balanced inputs- Connect a balanced signal through XLR input connectors. These should be used for all
long cable runs. Please note: Pin 1 Ground, Pin 2 Positive (+), Pin 3 Negative (-)
9. Stereo/Bridge Mode Switch- Bridged mono operation is easily achieved and gives you the output power
of both channels on just one mono output. For successful bridge operation, follow these instructions:
•
•
•
Set the Mode Selector to Bridge.
Connect a mono input signal to right input jack, channel 1.
Use only the terminal post outputs for speaker wiring, not the Speakon outputs. Connect the
speaker load to the red terminals of each channel. Please confirm the (+) terminal of speaker to
channel Right and the (+) terminal to channel Left. Do not use the black terminals of each channel.
The minimum load impedance in bridge mode is 8 Ohm.
•
•
To adjust level use channel 2 control and leave channel 1 level at zero.
10. Ground/Lift-Switch- To eliminate the ground loops between this amplifier and a preamplifier. Never
remove the center grounding pin of the AC plug!
11. Output Terminals- Output connections are to binding posts, which are identified as to polarity with a red
and a black terminal. We suggest the use of dual banana plugs as a convenient and reliable method of
hook-up. They allow rapid removal for polarity reversals, which is handy in the check-out and adjustment of
multi-element biamplified and triamplified sound systems. Heavy Class 11 wire may be used by unscrewing
the large plastic portion of the output terminal and inserting the wire into the hole provided. It is extremely
important when making wire connections that no wire strand or end touches the adjacent terminal, shorting
the output. Please do not use these outputs simultaneously with the speakon outputs, only alternatively.
CAUTION: Never strap the two red output terminals together (in parallel). Never connect either red
output to chassis ground.
12. Speakon outputs. For better contact security, use of these outputs is strongly recommended in all
applications, especially mobile systems. Do not use these outputs simultaneously with the output terminals,
only alternatively. Note the correct pin designation for the used speakon connectors: pos=1 + / neg = 1- /
2+, 2- not connected.
13. Fuse holder. This fuse holder contains AC primary fuse. Fuse should be replaced by same type fuse when
this is blown out. Disconnect the amplifier from AC mains before replacing a fuse. If they continuously blow,
stop replacing fuse and refer servicing to qualified personnel.
14. AC Power cord socket. Plug-in the supplied AC cord here and connect it into an AC outlet.
- The Leader in DJ Technology
©2000 Numark Industries
- 6 -
NPA3300-NPA6600
SPECIFICATIONS
Output power:
NPA3300:2x150W@4 ohm, 2x100W@8 ohm, 1x280W@8ohm bridged
NPA6600:2x300W@4 ohm, 2x200W@8 ohm, 1x480W@8 ohm bridged
NPA3300 < 900mV
Input sensitivity:
NPA6600 < 1200mV
Input impedance:
22kOhm (unsym) - 33kOhm (sym)
>70dB@1kHz
10Hz ... 100kHz
Channel separation:
Frequency response:
S/N ratio (JISA weighted):
NPA3300: 115dB
NPA6600: 117dB
THD:
<0.1% at rated power
Damping factor:
Dimensions:
Weight:
100@8Ohm
482mmx 88mmx 450mm including handles
NPA3300: 15.5kg
NPA6600: 21.kg
AC power requirement idle/max
(4 Ohm Load):
NPA3300: 45/530W
NPA6600: 55/1040W
230V/50Hz AC
Mains voltage:
Notes on protection circuits:
These amplifiers are equipped with different protection circuits to prevent any damage to the amplifier
itself or the speakers due to improper operation circumstances.
1. Overheat- For low mechanical noise emission, the built-in fan operates at low speed as long as
the internal heat sink keeps cooler than 55 degrees Celsius. The fan will speed up to maximum
speed when this temperature is exceeded. When the heat sink temperature exceeds 90 degrees
Celsius, the amplifier will shut down the outputs to avoid overheating. The outputs will be
automatically re-activated when the heat sink comes below 70 degrees Celsius.
2. DC on output- When DC is detected on the output, the amplifier will shut down the outputs to
avoid speaker damage.
3. Short circuit on the output- When a short circuit is detected on the output, the amplifier will shut
down the outputs to avoid damage to itself.
- The Leader in DJ Technology
©2000 Numark Industries
- 7 -
®
Professional Disc Jockey Products
LIMITED PRODUCT WARRANTY
1. What is covered and for how long? NUMARK INDUSTRIES LCC ("NUMARK") warrants to the original purchaser that NUMARK'S DJ mixers and amplifiers are
free from defects in material and workmanship under normal use and service for the period commencing upon the date of purchase from an authorized
NUMARK dealer and continuing for the following period of time after that date for (2) Years. The warranty is extended to (3) Years with the completion of the
warranty card provided that the warranty card is completed and returned within (30) days from the date of purchase. All other NUMARK products are warranted
for (1) Year including but not limited to CD players, turntables, preamplifiers, beatkeepers, equalizers, microphones, headphones, and all other accessories.
2. What is not covered? This Limited Warranty is conditioned upon proper use of the product by the purchaser.
This Limited Warranty does not cover: (a) defects or damage resulting from accident, misuse, abuse, neglect, unusual physical or electrical stress,
modification of any part of the product, or cosmetic damage; (b) equipment that has the serial number removed or made illegible; (c) all plastic surfaces
and other externally exposed parts that are scratched or damaged due to normal use; (d) defects or damage from improper testing, operation,
maintenance, installation, adjustment, or service of the mixers; (e) crossfaders.
3. What are NUMARK'S obligations? During the applicable warranty period, NUMARK will repair or replace, at NUMARK'S sole discretion, without charge to the
purchaser, any defective component part of the mixer. To obtain service under this Limited Warranty, purchaser must first contact NUMARK and obtain a return
authorization number ("RA#"). Purchaser must then return the mixer to NUMARK in an adequate container for shipping, accompanied by purchaser's sales
receipt or comparable proof of sale showing the date of purchase, the serial number of the product, and the seller's name and address. To obtain an RA# and
assistance on where to return the mixer, contact NUMARK customer service at 401-295 9000. Upon receipt, NUMARK will repair or replace the defective
products. NUMARK may, at NUMARK'S sole discretion, use rebuilt, reconditioned, or new parts or components when repairing any product or replace a
product with a rebuilt, reconditioned or new product. Repaired mixers will be warranted for a period equal to the remainder of the original Limited Warranty on
the original mixer or for (90) days, whichever is longer. All replaced parts, components, boards and equipment become the property of NUMARK. If NUMARK
determines that any mixer is not covered by this Limited Warranty, purchaser must pay all parts, shipping, and labor charges for the repair or return of such
mixer.
4. What are the limits on NUMARK'S liabilities? THE WARRANTIES GIVEN IN THIS LIMITED WARRANTY, TOGETHER WITH ANY IMPLIED WARRANTIES
COVERING NUMARK MIXERS, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE, ARE LIMITED TO THE DURATION OF THIS LIMITED WARRANTY. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, NUMARK
SHALL NOT BE LIABLE FOR ANY SPECIAL, INCIDENTAL, CONSEQUENTIAL, INDIRECT OR SIMILAR DAMAGES, LOSS OF PROFITS, DAMAGES TO
PURCHASER'S PROPERTY, OR INJURY TO PURCHASER OR OTHERS ARISING OUT OF THE USE, MISUSE OR INABILITY TO USE ANY NUMARK
MIXER, BREACH OF WARRANTY, OR NEGLIGENCE, INCLUDING BUT NOT LIMITED TO NUMARK'S OWN NEGLIGENCE, EVEN IF NUMARK OR ITS
AGENT HAS BEEN ADVISED OF SUCH DAMAGES, OR FOR ANY CLAIM BROUGHT AGAINST PURCHASER BY ANY OTHER PARTY. THIS LIMITED
WARRANTY IS THE COMPLETE WARRANTY FOR NUMARK'S MIXERS, AND IS GIVEN IN LIEU OF ALL OTHER EXPRESS WARRANTIES. THIS
LIMITED WARRANTY SHALL NOT EXTEND TO ANYONE OTHER THAN THE ORIGINAL PURCHASER OF THIS PRODUCT AND STATES PURCHASER'S
EXCLUSIVE REMEDY. IF ANY PORTION OF THIS LIMITED WARRANTY IS ILLEGAL OR UNENFORCEABLE BY REASON OF ANY LAW, SUCH PARTIAL
ILLEGALITY OR UNENFORCEABILTY SHALL NOT AFFECT THE ENFORCEABILITY OF THE REMAINDER OF THIS LIMITED WARRANTY WHICH
PURCHASER ACKNOWLEDGES IS AND WILL ALWAYS BE CONSTRUED TO BE LIMITED BY ITS TERMS OR AS LIMITED AS THE LAW PERMITS.
This Limited Warranty allocates risk of product failure between purchaser and NUMARK, and NUMARK'S product pricing reflects this allocation of risk and the
limitations of liability contained in this Limited Warranty. The agents, employees, distributors, and dealers of NUMARK are not authorized to make modifications
to this Limited Warranty, or make additional warranties binding on NUMARK. Accordingly, additional statements such as dealer advertising or presentation,
whether oral or written, do not constitute warranties by NUMARK and should not be relied upon.
5. How does state law apply to this warranty? SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL
DAMAGES OR HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO PURCHASER.
6. This Limited Warranty gives you specific legal rights. You may also have other rights, which vary from one jurisdiction to another.
RETURN INFORMATION
1. A Return Authorization number must be obtained from Numark through the address or phone numbers below.
2. A copy of the original sales receipt must also be included for the equipment to be repaired under warranty.
3. The faulty equipment must be packed in its original packaging.
4. One additional outer layer of packaging must be included to ensure product safety. Failure to do so may inadequately protect the equipment in transit
and, therefore, jeopardize the customer’s warranty.
5. Numark will not accept COD shipments and no call tags will be issued for merchandise return.
6. Numark will not return repaired merchandise to customers by priority service, unless by written request at the customer’s cost. Requests must be
submitted in writing with merchandise returned.
7. The defective Numark equipment should be sent, FREIGHT PREPAID with Return Authorization number clearly printed on the outer packaging and
original sales receipt enclosed to:
INDUSTRIES
Attention: Service Department
11 Helmsman Avenue
Phone: +1 (401) 295-9000
Fax::
Web:
+1 (401) 295-5200
North Kingstown, RI 02852 USA
|