Newcon Optik Binoculars LRB 7X50 User Manual

10. QUALITY CERTIFICATE  
The LRB 7X50 / LRB 7x50 SPD is suitable for use.  
Production date ____________________________  
Serial number ______________________________  
Quality Inspector signature _____________________  
Operation Manual  
Purchase date ______________________________  
Salesman _________________________________  
Shop stamp  
LRB 7x50 /  
LRB 7x50 SPD  
LASER RANGE FINDER BINOCULAR  
Newcon International ltd. © 1998-2003 Printed in Canada  
In USA: 3310 Prospect Ave. Cleveland, OH 44115  
In Canada: 1183 Finch Ave. W., Suite 302, Toronto, ON M3J 2G2  
Canada  
 
8. WARRANTY  
Features of the LRB 7X50 Laser Range Finder Binocular  
NEWCON OPTIK warrants this product against defects in  
material and workmanship for one year from the date of the  
original date of consumer's purchase, but no more than 18  
months from the date of manufacturing. Should your Newcon  
product prove defective during this period, please bring the  
product securely packaged in its original container or an  
equivalent, along with proof of the date of original purchase, to  
your Newcon Dealer. Newcon will repair (or at its option  
replace), the product or part thereof, which, on inspection by  
Newcon, is found to be defective in materials or workmanship.  
Latest digital circuitry allows targeting through most types of  
glass  
'Last Target' measurement  
Meters/Yards display  
Last 10 readings recall  
Selectable reticule shape (+ or )  
Target quality indicator  
Speed Finder (On LRB 7x50 SPD only)  
CONTENTS  
1. Brief description  
What This Warranty Does Not Cover:  
2. Appearance of the device  
3. Supplied accessories  
4. Technical characteristics  
5. Operation instructions  
NEWCON is not responsible for warranty service should the  
product fail to be properly maintained or fail to function  
properly as a result of misuse, abuse, improper installation,  
neglect, damage caused by disasters such as fire, flood,  
lightning, improper electrical current, or service other than by a  
NEWCON Authorized Service. Postage, insurance, or shipping  
costs incurred in presenting your NEWCON product for  
warranty service are your responsibility. Please include a check  
or money order made out to NEWCON OPTIK for the amount  
of $15.00 to cover shipping and handling. This covers products  
shipped in USA or Canada only.  
5.1. Preparing the device for operation  
5.2. Distance measuring procedure  
6. Storage and maintenance instructions  
7. Trouble shooting  
8. Warranty  
9. Customer Support  
10. Quality certificate  
 
BEFORE USE CAREFULLY READ ALL THE INSTRUCTIONS!  
7. TROUBLE SHOOTING  
The range measuring mode does not work.  
Press the Action Button again.  
Check that the batteries are installed properly. Check the charge of  
the batteries. Replace if they are weak.  
FAILURE TO OBEY THE INSTRUCTIONS WILL VOID  
THE WARRANTY!  
How can I clear last reading before making next measurement?  
Direct the unit’s LCD reticle at the new target, press the Action  
button. The new reading will appear.  
1. BRIEF DESCRIPTION  
LRB 7X50 (SPD) Laser Range Finder Binocular is an  
advanced Laser Range Finder system that provides instant  
distance measurements consistently and accurately. The  
stereoscopic device provides convenient observation with both  
eyes. The user can measure the distance to an object without  
loosing sight of the target. Therefore, the LRB 7X50 (SPD)  
substitutes a need for two separate devices (binocular and range  
finder) combining both requirements in a single device.  
There are black dots in the image.  
A LCD (Liquid Crystal Display) is installed in the optical channels  
of the device. Due to manufacturing imperfections in the  
production process of the LCD, small black dots, scratches and  
other blemishes might be visible. Those blemishes are strictly  
regulated for maximum allowed number, size and location. It does  
not degrade the product's performance.  
The outstanding optics provide a sharp, clear image under all  
conditions. LRB 7X50 (SPD) is utilizing a revolutionary digital  
design, which is outperforming any other product in its class and  
price range.  
Range measurement cannot be obtained.  
Check if range detection mode is activated (message READY  
appears on the LCD display)  
Check if Active Button is pressed  
The unit sends invisible, eye safe laser beam pulses to the target.  
The returned beams are captured by the digital circuitry. The  
time differential allows us to calculate the distance to the target.  
Make sure that neither your hand nor finger is blocking  
objective lenses (Laser emitting lens or Receiver lens).  
Check if the unit is steady while pressing Action button.  
 
6. STORAGE AND MAINTENANCE INSTRUCTIONS.  
2. APPEARANCE OF THE DEVICE  
Precautions: LRB 7X50 (SPD) is a sophisticated precision  
optical instrument equipped with electronics. Therefore, it  
should be handled with due care.  
4
1
6
Keep your device away from direct sunlight, impact, dust,  
moisture, and sudden changes of temperature.  
Do not touch the optical surfaces with fingers. Doing so  
may damage the anti-reflection coating.  
7
Avoid shocks and sharp jolts.  
Clean optical surfaces with professional camera lens  
cleaning supplies.  
5
To clean the exterior of the device, use a soft clean cloth.  
Keep away from heating appliances and central heating.  
Remove the batteries when storing the device for long  
period of time.  
2
8
3
Do not apply unnecessary force to the lens assembly, agile  
elements and thread connections.  
Only the manufacturer should perform repair work.  
1 – Eyepieces; 2 – Objective Lens / Emitting Lens  
3 – Objective Lens / Receiver Lens; 4 – Dioptric Correction Ring;  
5 – Mode Button; 6 – Action Button; 7 – Body of the Device;  
8 – Rubber Grip  
Fig. 1  
 
1
TARGET REFLECTION MED - when the number of  
steady received reflected signals is in medium range and  
enough to make positive conclusion about the measured  
distance;  
TARGET REFLECTION HIGH - when the number of  
steady received reflected signals is qualified to be enough to  
make reliable conclusion about the measured distance.  
Patent pending  
Newcon Optik  
Made in Canada  
The displayed statistical qualification of the reflected signal  
characterizes variation in expected accuracy of measurements. At  
qualification HIGH the accuracy of measurements is stated as  
±1m or ± 0.1%. At lower rates of statistical qualification the  
expected accuracy may marginally degrade.  
9
10  
1 – Eyepieces; 9 – Interpupilary distance adjustment lever  
10- Identification Label (Located on the Bottom)  
Please note: this is an optional feature.  
Fig. 2  
The display presents message LOW BAT – when voltage of the  
primary 9-volt battery drops below 7.2 volt. At this point the  
System is still functional but the battery should be replaced as  
soon as possible. The system can operate at the voltage levels  
above 7 volts.  
3. SUPPLIED ACCESSORIES  
LRB 7X50 is supplied in the following assembly:  
- Device  
- Carrying Case  
- Neck Strap  
- User’s manual  
- Warranty card  
- 9V battery (optional)  
1 pc.  
1 pc.  
1 pc.  
1 pc.  
1 pc.  
1 pc.  
The System remains in the active displaying state for 10 seconds  
after pressing of any of the operating buttons and after 10 seconds  
enters the passive low power state.  
Alkaline or lithium type of batteries capable to sustain current  
drain up to 150 ma should be used for powering the System.  
 
CL - clear data function: upon pressing the Action button (6)  
(fig. 1) the entire data on all previous measurements will be  
erased.  
NOTE: After changing a battery the recall stack should be  
cleared by exercising the CL mode.  
4. TECHNICAL CHARACTERISTICS  
1. Optics  
Observation  
Magnification, x  
Objective Lens, mm  
Exit Pupil Diameter, mm  
Eye Relief, mm  
Field of View  
Axial Resolution, ”  
Image tilt, maximum  
Binocular  
7
50  
7.1  
25  
5°  
6
OVER 100 – allows to ignore targets closer than 100m. Useful  
when looking through bush.  
Please note: this is an optional feature on early designs. Latest  
version includes automatic “Last Target” selection that renders  
obsolete the requirement for a separate manual mode selection.  
c. Reflection  
-
-
Horizontal  
Vertical  
60”  
30”  
Distance measuring procedure includes instant statistical  
processing of the package of single measuring sessions.  
Qualitative result of the statistical processing is presented on the  
Display as a message TARGET REFLECTION (5).  
There are four statistical qualifications of the reflected signal:  
Type of coating  
Fully multi-coated optics  
58-72  
Interpupillary Distance, mm  
Diopter Adjustment range  
Reticule  
±4  
Corresponds to laser  
direction and approx. size  
of the laser on target  
NO TARGET REFLECTION – when a reflected signal  
isn’t received. Numerical display shows 4 dashes in the  
distance displaying area;  
TARGET REFLECTION LOW – when the number of  
steady received reflected signals is just enough to make  
acceptable conclusion about the distance;  
 
-
-
-
REC 0 will show instead of REC10  
2. Range Finder  
Type  
Measuring Range, m  
Accuracy, m  
If a position is empty then 4 dashes (----) will be displayed  
After REC 0 the demonstration will restart with REC 1,  
REC2, and so on  
Class 1 eye safe, 905nm  
20-1,512  
±1 ± 0.1%  
2) If the last measurement was that of speed, then the speed will  
show in  
REC1; the distance of the vehicle will show in REC2 and so on.  
3) The self test procedure was completed properly if:  
-
-
Resolution, m  
1
<1  
Yes  
Measurement time, sec  
Meters/Yards display  
Last 10 readings recall  
Reticule shape ( + or )  
Target quality indicator  
Scan Mode  
Speed Finder  
3. Miscellaneous  
Battery  
Battery capacity  
'Low Battery' Indicator  
Covering  
Construction  
Tripod thread  
Operational Temperature  
Range  
Storage Temperature Range  
Shock, g  
Vibration, Hz  
Dimensions, mm  
Weight, kg  
Yes  
The square and cross reticle are flashing alternately  
The lightening power symbol, reticle , square, 7 segment  
numbers, KMH and MPH segments on the screen are  
visible.  
Optional  
Optional  
Yes  
LRB 7x50 SPD only  
Y/M – units of measurement: yards or meters (3).  
KMH/MPH – units of speed measurement: km/hour or miles/hour  
(3). Please note: only on LRB 7x50 SPD.  
Standard 9v  
>3000  
Yes  
Shape of the reticle: cross shape or rectangular shape (2). Please  
note: this is an optional feature.  
Rubberized  
Water resistant  
1/4"x20  
rEC1 - recall function. Upon pressing the Action button (6) (fig.  
1) the Display will sequentially show results of last 10  
measurements, starting from the latest one. The number appearing  
after word "REC" shows the number of the measurement counted  
back in the sequence. When the System is in inactive state the 10  
previous measurements are stored within the System and may be  
recalled any time.  
-30 / +55oC  
-45 / +85oC 65  
5 – 500  
210x150x80  
1.300  
 
5.2.6 Mode Selection State  
5. OPERATION INSTRUCTIONS  
Liquid Crystal Display (LCD)  
Correct Order of Modes  
LRB 7x50  
LRB 7x50 SPD  
Y
M
+
MPH  
KMH  
+
6
1
REC1  
CLR  
Y
M
SELFTEST3  
REC2  
5
CLR  
2
1) REC1 shows the value of the last measurement, REC 2 the  
previous measurement and so on.  
b. Mode selection state  
4
Pressing MODE button (5) (fig. 1) when the System is in  
READY mode brings the System to the Mode selecting state.  
Pressing the Mode button can sequentially scan the Modes. The  
Mode under selection is being indicated on the Display by  
flashing of the selectable feature. The "flashing" feature can be  
selected by pressing the Action button (6).  
3
1 – Low Battery Indicator; 2 – Reticule (cross or rectangular selectable);  
3 – Units of Measurement (Yards, Meters, KMH,  
MPH or Degrees); 4 – Measurement Result;  
5 – Target Quality Indicator (optional); 6 – Laser Active Indicator  
Fig. 3  
The System operates in the setting Modes, which are displayed  
as follows (refer to fig.3):  
 
Pressing Action button (6) (fig. 1) at this point triggers a distance  
measuring session, and the result will be displayed in numerical  
form (4) (fig. 3) (if measurement is unsuccessful then four dashes  
‘----‘ will appear in the numerical area). Please note that the target  
must be over 20m away.  
5.1. Preparing the Device for Operation  
Unbolt a screw and open battery compartment cover at the  
bottom of the device.  
Insert one 9V battery (sold separately) into the battery  
compartment observing correct polarity.  
If the Action button (6) is held (pressed) for more than 3 seconds  
the System automatically enters SCANNING mode. This feature  
is not available on all versions.  
Close up the battery compartment cover, tighten the screw.  
After changing the battery, it is recommended to run the CL  
(CLEAR) mode (refer mode selection procedure).  
At this mode the System repetitively performs distance measuring  
and displaying. The time interval between measurements is  
approximately 1 second.  
Take off lens caps  
Look through the eyepieces (1) (fig. 1).  
Adjust interpupilary distance by turning lever (9) (fig. 2)  
until two images converge into one  
The maximum measuring range for most objects will be 1512m.  
The maximum measured distance will vary greatly depending on  
the reflectivity of the target, weather conditions and more.  
Make dioptric correction individually for each eye by  
rotating rubber rings (4) (fig. 2) of each eyepiece  
Target reflectivity depends on its color, surface finish, shape etc.  
Bright colors are more reflective than darks. A polished surface is  
more reflective than a rough one. Larger targets are easier for  
distance measuring. Measuring a target faced at 90o (perpendicular  
to the laser beams path) provides optimal results.  
Bad weather conditions (rain, fog, snow, mist) will reduce the  
maximum measured range.  
Now your unit is ready for operation as a conventional 7x  
binocular (passive state).  
5.2. Distance Measuring Procedure  
a. Measuring state  
When the Rangefinder is in the passive, low power state, the  
LCD Display is blank (transparent).  
Pressing any of the operating buttons activates the System and  
the Display. Initially the System always assumes READY mode  
of operation and word READY appears on the Display.  
Bright sunny days will reduce performance as well  
While the unit will work through many glass types, measuring through  
glass will affect the results.  
 

Miele Oven H4892BP2 User Manual
Multi Tech Systems Network Card MT5600BR V92 User Manual
Murphy Network Card EMS447 User Manual
Nortel Networks Cordless Telephone 743X User Manual
Omnimount TV Video Accessories G353 User Manual
Oregon Scientific Clock BAA339DPH User Manual
Oregon Scientific Clock RMR602A User Manual
Oregon Scientific Weather Radio BAR1000A User Manual
Panasonic Camcorder AG HMC151E User Manual
Panasonic Vacuum Cleaner MC UL427 User Manual