Multiquip Portable Generator MQP240 User Manual

ꢀ MQP240  
Diesel Generator  
Prime rating — 240 kW (300 kVA)  
standby rating — 260 kW (330 kVA)  
3-Phase, 60 Hertz, 0.8 PF  
standard Features  
Heavy duty, turbocharged, direct injection diesel engine  
provides maximum reliability.  
Complete engine analog instrumentation includes DC  
ammeter, oil pressure gauge, fuel gauge, water temp. gauge,  
tachometer/hour meter, preheat indicator, manual engine  
speed control, emergency shutdown monitors, and emergency  
stop button.  
Brushless alternator reduces service and maintenance  
requirements and meets temperature rise standards for Class  
F insulation systems.  
Complete generator analog instrumentation includes  
voltage regulator control, ammeter phase selector switch,  
voltmeter phase selector switch, AC voltmeter, AC ammeter,  
frequency meter, panel light, and circuit breaker.  
open delta alternator design provides virtually unlimited  
excitation for maximum motor starting capability.  
automatic voltage regulator (avr) provides precise  
regulation.  
automatic safety shutdown system monitors the water  
temperature, engine oil pressure, overspeed, and overcrank.  
Warning lights indicate abnormal conditions.  
electronic governor system with idle switch maintains  
frequency to 0.25%.  
autostart/stop controlallows generator to start automatically  
in the event of a commercial power failure.  
Full load acceptance of standby nameplate rating in one  
step (NFPA 110, para 5-13.2.6).  
Complete power panel. Fully covered;three-phase terminals  
and single phase receptacles allow fast and convenient  
hookup for most applications including temporary power  
boxes, tools and lighting equipment. All are NEMA standard.  
sound attenuated, weather resistant, steel housing  
provides operation at 73 dB(A) at 23 feet. Fully lockable  
enclosure allows safe unattended operation.  
Fuel/water separator removes condensation from fuel for  
extended engine life.  
two stage air lter  
simultaneous single and three phase power  
emergency stop switch  
e-Coat primer with polyurethane enamel finish coat.  
low coolant level shutdown system provides protection  
from critically low coolant levels. Includes control panel  
warning light.  
Battery switch  
documentation box  
ePa emissions certied - Tier 3 emissions compliant.  
MQP240 — diesel generator — rev. #0 (10/05/12)  
 
ꢀ MQP240  
Diesel Generator  
oPtional generator Features  
MQ POWER DECIBEL LEVELS  
U
Our soundproof housing  
allows substantially  
lower operating noise  
levels than competitive  
designs. WhisperWatts  
are at home on  
Battery charger — provides fully automatic and self-  
adjusting charging to the generator's battery system.  
Subway / truck traffic  
90  
80  
70  
Jacket water heater — for easy starting in cold weather  
climates.  
Average city traffic  
MQP240 at 23 feet  
Inside car at 60 mph  
special batteries — long life batteries provide extra engine  
cranking power.  
construction sites, in  
residential  
Air conditioner at 20 feet  
Normal conversation  
60  
50  
neighborhoods, and at  
hospitals — just about  
anywhere.  
spring isolaters — provides extra vibration protection for  
standby applications.  
trailer mounted package — highway legal trailer with  
electric or surge brakes with triple axle configuration. Extra  
capacity fuel tanks are also available.  
DECIBELS  
oPtional Control Features  
audible alarm — alerts operator of abnormal conditions.  
generator outPut Panel  
oPtional Fuel Cell Features  
trailer fuel tank — fuel cell located in the trailer.  
CIRCUIT BREAKERS  
FOR CS-6369 TWIST  
LOCK RECEPTACLES  
subbase fuel cell (double wall) — contains a leak  
sensor, low fuel level switch, and a secondary containment  
tank. UL142 listed.  
CIRCUIT BREAKERS  
FOR GFCI RECEPTACLES  
12 hours of minimum run time.  
24 hours of minimum run time.  
oPtional outPut ConneCtions  
GFCI RECEPTACLES (2)  
120V, 20 AMP  
CS-6369 TWIST-LOCK  
RECEPTACLES (3)  
240Y/139, 50 AMPS  
Cam-loks — provides quick disconnect alternative to bolt-  
on connectors.  
Pin and sleeve Connectors — provides industry standard  
connectors for all voltage requirements.  
U
V
W
O
output Cable — available in any custom length and size  
configuration.  
1Ø AND 3Ø  
120-480 VAC OUTPUT  
LUG TERMINALS  
NEUTRAL  
TERMINAL  
GROUND  
TERMINAL  
MQP240 — diesel generator — rev. #0 (10/05/12)  
 
ꢀ MQP240  
Diesel Generator  
diMensions  
1800 mm/  
70.87 in.  
1320 mm/  
51.97 in.  
900 mm/  
35.43 in.  
900 mm/  
35.43 in.  
900 mm/  
35.43 in.  
650 mm/  
25.60 in.  
450 mm/  
17.72 in.  
1400 mm/  
55.12 in.  
2180 mm/85.82 in.  
3800 mm/149.61 in.  
Weight  
Dry Weight  
8,645 lbs. (3,920 kg)  
Wet Weight  
8,865 lbs. (4,020 kg)  
Max. Lifting  
Point Capacity  
16,500 lbs. (7,484 kg)  
1115 mm/  
43.90 in.  
1010 mm/  
39.76 in.  
585 mm/  
23.03 in.  
Lifting Point  
139 mm/  
5.50 in.  
640 mm/  
25.20 in.  
270 mm/  
10.63 in.  
296 mm/  
11.65 in.  
1010 mm/  
39.76 in.  
1115 mm/  
43.90 in.  
Your Multiquip dealer is:  
MultiQuiP  
POST OFFICE BOx 6254  
CARSON, CA 90749  
310-537-3700 • 800-883-2551  
FAx: 310-604-3831  
© COPYRIGHT 2012 MULTIQUIP INC.  
MQP240 Rev. #0 (10/05/12)  
 

Moultrie Welder 120704R04 MFH PEK User Manual
MTD Snow Blower 500 Series 600 Series User Manual
NordicTrack Treadmill NTL10950 User Manual
Nortel Networks Telephone 413X User Manual
Olympus Printer P S100 User Manual
Onkyo Stereo System TX SR504 B User Manual
Optoma Technology Projector EP753 User Manual
Oster Blender 153034 000 000 User Manual
Panasonic Air Conditioner CS MKE12NKU User Manual
Parasound Stereo Amplifier HCA 1205A User Manual