750kW Containerized
Diesel Generator Set
Model
Emissions
Standby Rating
Prime Rating
60 Hertz
EGC-750C
EPA Certified
750kW (937kVA)
600kW (750kVA)
750 KW
(Shown with 40 ft. container and optional ISO trailer chassis)
Standard Features
Cummins Heavy Duty Diesel Engine
Full Load Acceptance
4-cycle design, turbocharged, aftercooled, direct injection
Polymide blade cooling fan
Accepts 100% of standby nameplate rating in one step, in compliance
with NFPA, para 5-13.2.6
Engine coolant heater
Generator Control Panel
Meets EPA emissions standards for mobile off-highway
InteligenTM vibration-isolated controller
Manual or remote engine start/stop
RS232/Modbus communication support
Safety shutdowns
Fuel System
1000 gallon, single wall fuel tank
Fuel priming system
Fuel/water separators and drip pan
Electric fuel pump
Externally mounted emergency stop switch
Generator mainline circuit breaker, 100% rated electronically
operated, UL listed
External fuel fill
Specially Designed Container
®
30 micron Racor fuel filter system
■
40 ft. ISO container, sound-attenuated, foam-lined for extremely
quiet operation
Alternator
Brushless, 4-pole, synchronous, WYE connection
■
Isolated operator control room
Class H insulation system conforms to NEMA MG1-22, BS5000,
CSA-C22-2, IEC-34-1 standards for temperature rise
Solidly mounted battery rack and cooling system
Intregral vibration isolators
Drip-proof, self-venting, amortisseur windings
Exterior polyurethane coating system provides long life in extreme
operating conditions
Epoxy impregnated windings with tropical insulation for increased
environmental protection and long life
Interior DC lights and timer switch
Electronic Voltage Regulator
Critical grade silencer with heat blankets
■
■
Electronic automatic voltage regulator provides precise regulation
Warranty
Engine-generator sets are covered by an express written, one-year
limited warranty
Separate three-phase excitation for fast recovery from block loads
and motor starting
750kW Containerized
Diesel Generator Set
Cooling System
Exhaust Manifold Type
Radiator Design
Dry
Standard horizontal discharge
Coolant Capacity - Engine and Radiator
Water Pump Design/Type
Coolant Flow
53 gal. (201 L)
Belt Driven, Centrifugal
235 gal/min (889.5 L)
27860 BTU/min (29.5 kW)
42.7 hp (32.0 kW)
Heat Rejection to Coolant (Standby)
Fan Horsepower
Inteligen Digital Genset Controller
Digital Controller Features
Fuel System
■
■
■
■
■
■
■
Large graphic back-lit LCD display 128x64 pixel resolution
Automatic and manual starting and stopping
Phase sequence supervision
Recommended Fuel
Filter Micron Size - 98% Efficiency
Total Fuel Flow
ASTM-D975-No.1 or No. 2-D
2
99 gal./hr. (374.7 L/Hr.)
Automatic shutdown/alarm function
Fuel Consumption
Input frequency 50-60 Hz
Diesel Fuel @ % of Load
gal/hr
16.0
26.2
40.5
54.7
L/hr
61
Parameters adjustable via PC or iG keyboard
25%
50%
99
Predefined and user definable configurations available.
One configuration includes set of inputs/outputs and parameters
75%
153
207
100%
■
■
■
■
■
■
■
■
■
■
■
Adjustable parameters for each configuration
6 LED indicators
Push buttons for simple control
4 programmable outputs (out of 20 functions selection)
4 binary configuration inputs
Standby
o
895 F
Prime
o
850 F
Exhaust System
Lamp test during start up
Exhaust Temperature at Rated kW
o
(479.4 C)
o
(454.4 C)
Real time clock
6160 cfm
(174.3 m3/min)
5546 cfm
(157 m3/min)
Sealed membrane panel to IP65
180 x 113 mm front panel mounted case
Speed measurement from magnetic pickup
Exhaust Flow at Rated kW
Silencer Type
Critical
Maximum Allowable Backpressure
Exhaust Outlet Size at hook-up
41 in/wc (10.2 kPa)
2 x 8 in.
Oil pressure, Coolant temperature, Battery voltage and Fuel level
measurements
■
■
■
■
■
■
■
■
■
■
Running Hour Meter
All Generator metering, kVAr, kW, V1-V3, Hz, I1-I3, kWh, kVAh
Generator under/over voltage alarm/shutdown
Generator under/over frequency alarm/shutdown
Over Current alarm/shutdown
Derating (60Hz)
Ambient
Temperature
Altitude
The engine may be operated up to 5000 ft.
altitude and 95oF ambient temperature at the
Standby rating, without derating. For
operation at higher altitudes and ambient
temperatures, the power should be derated
according to the following factors:
Warm up and cooling functions
Above 5000ft. Above 95°F
derate at 4% derate at 1%
per 1000 ft. per 10°F
Pre-lubrication function with timers
Adjustable crank attempts
Data logging
Remote communications (RS232/Modbus)
750kW Containerized
Diesel Generator Set
Optional Features and Accessories
Container
Generator Set
ISO Trailer Chassis (40 ft.)
Genset-to-Genset Paralleling Control System
Double-wall Fuel Tank (900-gallon capacity)
Fluid Containment
Base Load-to-Utility Paralleling Control System
Custom Outlet Panels
Manual Fuel Valves (For Internal or External Fuel
Supply)
Rotary Voltage Selector Switch (High Wye/Low Wye
Voltages)
Entrance Ladder (6-Step, Aluminum Construction)
Auxiliary Oil Reservoir with Level Control (15-gallon)
Centrifugal Oil Filter System
Fueling Ladder (Aluminum Step Construction with
Hand Rail)
Oil Pan Heater with Thermostat
Interior Lights (AC Work lights)
Alternator Strip Heater
Custom Paint Colors (Artic White is Standard)
AC Battery Charger with Shore Power Receptacle
SPECIAL OPTIONS AVAILABLE UPON REQUEST
40 ft Container
Weight and Dimensions
A
B
C
D
96 in.
(2,438 mm) (12,192 mm) (4,137 mm) (5,054 mm)
480 in.
163 in.
199 in
Weight (Wet)*
37,760 lbs (17,128 kg)
44,500 lbs (20,185 kg)
Weight (Wet with trailer)*
* Weight is approximate. Wet weight does not include fuel.
Backfeed to a utility system can cause electrocution and/or property damage. Do
not connect to any building’s electrical system except through an approved device.
Specifications are subject to change without notice.
Your MQ Power dealer is:
MQ POWER
POST OFFICE BOX 6254
CARSON, CA 90749
310-537-3700
•
800-421-1244
FAX: 310-632-2656
E-MAIL: [email protected]
© COPYRIGHT 2007, MQ POWER
Rev. 1 (03-07) EGC750C
|