Owner’s Manual
No500H Series
Power Amplifier
Important Safety Instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with a dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s
instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus
that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has
two blades with one wider than the other. A grounding-type plug has two blades and a third
grounding prong. The wide blade or third prong is provided for your safety. If the provided plug
does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched, particularly at plugs, convenience
receptacles and the point where it exits from the apparatus.
11. Only use attachments and accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket or table specified by the manufacturer
or sold with the apparatus. When a cart is used, use caution when moving the cart/
apparatus combination to avoid injury or tip over.
iii
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has
been damaged in any way, such as when the power-supply cord or plug is damaged; liquid has
been spilled or objects have fallen into the apparatus; or the apparatus has been exposed to rain
or moisture, does not operate normally or has been dropped.
15. The MAIN'S cord is intended to be the safety disconnect device for this apparatus and shall
remain readily operable at all times.
16. Ventilation should not be impeded by covering the ventilation openings with items such as
newspapers, tablecloths, curtains and so on.
17. No naked flame sources, such as candles, should be placed on the apparatus.
18. Terminals marked with this symbol may be considered HAZARDOUS LIVE, and
the external wiring connected to these terminals requires installation by an
INSTRUCTED PERSON or the use of ready-made leads or cords.
19. This product must be terminated with a three-conductor AC mains power cord that includes an
earth ground connection. To prevent shock hazard, all three connections must ALWAYS be used.
Warning!
To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. The
apparatus shall not be exposed to dripping or splashing. No objects filled with liquids, such as
vases, shall be placed on the apparatus.
Mark Levinson
Safety Terms & Symbols
These terms may appear in this manual:
Calls attention to a procedure, practice, condition or the like
that, if not correctly performed or adhered to, could result in
personal injury or death.
Warning!
Caution!
Note
Calls attention to a procedure, practice, condition or the like
that, if not correctly performed or adhered to, could result in
damage or destruction to part or all of the component.
Calls attention to information that is essential to highlight.
These symbols may appear on the product:
Appears on the component to indicate the presence of
noninsulated, dangerous voltage inside the enclosure – voltage that
may be sufficient to constitute a risk of shock.
iv
Appears on the component to indicate important operation and
maintenance instructions included in the accompanying
documentation.
Appears on the component to indicate compliance with the EMC
(Electromagnetic Compatibility) and LVD (Low-Voltage Directive)
standards of the European community.
Documentation Conventions
This document contains general safety and operation instructions
for the Nº500H Series Power Amplifiers. It is important to read
this document before attempting to use this product. Please pay
particular attention to safety instructions.
This manual is not intended as a general reference guide for audio or
home theater systems. If you’re uncertain how to set up or maintain your
system, seek the advice of a professional installer or ask your dealer for a
recommendation.
Nº500H Series Power Amplifier
Table of Contents
Introduction.............................................................................. 2
Product Description.....................................................................2
What’s in the Box ........................................................................2
Product Registration....................................................................3
Installation Considerations........................................................ 3
Unpacking..................................................................................3
Placement and Ventilation...........................................................3
Power Requirements ................................................................. 4
Operating States.........................................................................5
Front Panel............................................................................... 6
Rear Panel ................................................................................ 7
Network Setup........................................................................ 10
Material Requirements...............................................................10
Computer Requirements ...........................................................11
Connecting the Cables..............................................................11
Internal Web Page ....................................................................12
Network Setup Parameters........................................................12
Connecting With DHCP (Recommended)...................................13
Setting Up the Computer ..........................................................14
Connecting With Static IP Addressing ........................................15
Direct Connection.....................................................................17
ML Net ................................................................................... 18
Masters and Slaves....................................................................18
Connecting the Devices ............................................................18
Discovering Slaves.....................................................................19
Status Reporting .......................................................................19
Fault Reporting.........................................................................19
1
Troubleshooting...................................................................... 20
Fault Protection ...................................................................... 22
ML Net Fault Conditions.......................................................... 22
Restoring Factory Defaults ...................................................... 23
Care & Maintenance................................................................ 23
Specifications.......................................................................... 24
Declaration of Conformity....................................................... 26
Mark Levinson
Introduction
Thank you for purchasing the Nº531H, Nº532H, Nº533H or Nº535H
Power Amplifier. True to Mark Levinson® tradition, the audio
excellence and performance levels of the Nº500H series amplifiers
are unrivaled in today’s marketplace.
The Nº500H series amplifiers redefine the concept of outstanding
performance in their categories. Drawing from the Mark Levinson
heritage, while utilizing a new, straightforward, balanced, current-
feedback design, creates a new series of amplifiers that must be
listened to in order to be fully appreciated. The final result is
impressive, even for the Mark Levinson high standard of excellence.
Product Description
Independent power supply components are used for each channel
to maximize the isolation between channels, thus improving
imaging. Isolated chassis and signal grounds minimize noise to
optimize detail, even at low listening levels.
The amplifier channel itself is simple but elegant. Like the Nº532,
the audio path is fully differential, thereby handling balanced
input signals in their native format, ensuring no noise is added
by unnecessary signal conversions. Care was taken in component
selection, insuring high-quality passive components are used in
critical locations, maximizing the potential sonic benefits.
2
The Nº500H Series amplifiers may be operated through a network-
capable Ethernet port for use with ML Net and external protocol
controllers, and standard DC trigger controls.
Embracing new technology with the same level of enduring
excellence, the Nº500H Series amplifiers are each the finest in their
category. Truly impressive output capabilities, combined with the
high-power efficiency of all Mark Levinson amplifiers, make the
Nº500H Series remarkably capable amplifiers, sure to impress even
the most demanding of audio enthusiasts.
What’s in the Box
The shipping box includes:
Quantity
Item
Power amplifier
1
Nº500H series owner’s manual (this document)
Heavy white gloves
1
2 pairs
Cable with 3.5mm mini-plugs (for use with trigger)
1
1
Detachable AC power cord*
*varies by destination country
Nº500H Series Power Amplifier
Register your Nº500H series amplifier online at
the original, dated sales receipt as proof of warranty coverage.
Product Registration
Installation Considerations
The Nº500H series power amplifier requires special care during
installation to ensure optimal performance. Pay particular
attention to instructions included in this section and to
precautions included throughout this owner’s manual.
Unpacking
DO save all packing materials for possible future shipping needs.
DO inspect the amplifier for signs of damage during shipment.
If damage is discovered, contact your authorized Mark Levinson
dealer for assistance in making appropriate claims.
DO locate and remove the accessory bag from the carton. Make
sure it contains all of the items listed in the “What’s in the Box”
table on the previous page. If not, contact your authorized Mark
Levinson dealer.
3
Caution!
DO NOT attempt to lift or move the power amplifier without
adequate assistance. The shipping weight of the amplifier
exceeds what a single person should lift alone. To avoid injury
or damage to the unit, at least two people are required to lift or
move the amplifier.
Two pairs of knit white gloves with special gripping surfaces
on the palms and fingers are ncluded with the amplifier. Wear
these gloves when lifting or moving the amplifier.
DO install the power amplifier on its own shelf for proper
ventilation.
Placement and
Ventilation
DO install the amplifier chassis on a solid, flat, level surface.
DO install the power amplifier close to associated components to
keep interconnecting cables as short as possible.
DO select a dry, well-ventilated location out of direct sunlight.
DO allow at least 3 to 4 inches (8 to 10cm) of clearance above and
on each side of the amplifier for proper heat dissipation.
Mark Levinson
DO allow at least 6 inches (15cm) of clearance behind the amplifier
so that the power cord and cables have space to bend without
becoming crimped or strained.
DO NOT place the amplifier chassis on a thick rug or carpet or
cover the amplifier with a cloth, as this might prevent proper
cooling.
DO NOT obstruct the ventilation holes on the top and bottom of
the chassis or reduce airflow through the amplifier.
DO NOT place the amplifier chassis near low-level components.
The power amplifier is capable of producing large output currents
and hence significant magnetic fields, which can induce noise in
sensitive components.
DO NOT expose the power amplifier to high temperatures,
humidity, steam, smoke, dampness, or excessive dust. Avoid
installing near radiators and other heat-producing appliances.
Warning!
MAKE SURE all components are properly grounded. Do not
defeat the safety purpose of polarized or grounding-type plugs
with “ground-lifter” or “cheater” adapters. Doing so may cause
dangerous voltage to build up between components, which can
result in personal injuries and/or product damage.
4
Power Requirements
The Nº500H series power amplifier is configured at the factory for
100, 120, or 230 VAC power operation at 50Hz or 60Hz. Before
operating the amplifier, ensure that the power label on the rear
panel near the AC input connector indicates the correct operating
voltage.
Caution!
DO NOT attempt to adjust the operating voltage. Consult a Mark
Levinson dealer if the operating voltage is incorrect or must be
changed for relocation purposes.
Different operating voltages may require the use of different
power cords and/or attachment plugs. Contact a Mark Levinson
dealer for additional assistance.
The Nº500H series power amplifier is capable of passing remarkable
sound at exceptional power levels. Depending on listening habits,
loudspeaker demands, and the number of power amplifiers present
in the system, it is possible that the electrical service may become
the limiting performance factor of your system.
Nº500H Series Power Amplifier
If this case occurs, consider installing a dedicated AC circuit for the
system. Contact a licensed electrician for assistance. If more than
one AC circuit is providing power to the system, contact a licensed
electrician to ensure that all components are operating with the
same solid, low-impedance ground reference.
Caution!
Building regulations and electrical codes differ from location to
location, making it impossible to anticipate the requirements
of amplifier high-current AC circuits, such as the No500H series
power amplifier is capable of using. Contact a local, licensed
electrician for further information.
Operating States
The Nº500H series power amplifier is designed for continuous
operation and has three operating states:
•
•
Off – AC power is disconnected using the rear-panel Power
switch or by removing the power cord from the rear panel.
Standby – this is an energy-saving mode. AC power is only
connected to the low-voltage power supply, so all nonaudio
functions, such as ML Net and triggers, are active.
5
•
On – the amplifier is fully powered and all outputs are active.
The amplifier should be unplugged during lightning storms and
extended periods of nonuse as a precaution against potentially
damaging power surges through the line.
Caution!
BEFORE moving the power amplifier, make sure it is powered
off with the Power button. Then make sure the power cord is
disconnected from the rear panel connector and the electrical
outlet.
Mark Levinson
Front Panel
The front panel contains one LED and one Standby button –
as shown.
Status LED
standby
Standby
Button
Standby Button
Places the amplifier into Standby mode. Pressing the button while
the amplifier is in Standby mode turns on the amplifier.
6
Standby mode powers only the low-voltage power supply, control,
and communication circuits.
Status LED
Indicates the operating state of the amplifier and provides basic
diagnostic information if a fault condition occurs. The table below
identifies the basic behavior of the Status LED.
LED Behavior
Fully lit
Description
Indicates that the amplifier is powered on.
Indicates that the amplifier is in Standby mode.
Indicates that the amplifier is powered off.
Slowly blinking
Not lit
Refer to the “Troubleshooting” section in the back of the manual
for a description of the Status LED behavior when a fault is
detected.
Nº500H Series Power Amplifier
Rear Panel
The images below show a one-channel, two-channel, three-channel
and five-channel rear panel view.
Audio Input
Ethernet Port
Trigger Input/Output
Nº531H Monaural
Power Amplifier (1 x 300W)
Power Switch
Loudspeaker
Binding Posts
AC Input
Audio Input
Ethernet Port
Trigger Input/Output
Nº532H Dual-Channel
Power Amplifier (2 x 300W)
Power Switch
Loudspeaker
Binding Posts
AC Input
Audio Input
Ethernet Port
Trigger Input/Output
Nº533H Three-Channel
Power Amplifier (3 x 300W)
Power Switch
AC Input
Loudspeaker
Binding Posts
7
Ethernet Port
Trigger Input/Output
Nº535H Five-Channel
Power Amplifier (5 x 200W)
Audio Input
Power Switch
Loudspeaker
Binding Posts
AC Input
Power Switch
Controls the AC power to the input of the amplifier when a
power cord is connected from the electrical outlet to the AC input
connector on the rear panel.
When the Power switch is pressed to turn on the unit, the amplifier
enters the Standby mode.
Note
The audio outputs of this power amplifier are considered Class 2 (CL2)
circuits in North America. This means the wire connected between this
amplifier and the speaker(s) shall be rated at minimum Class 2 (CL2)
and shall be installed according to the U.S. National Electrical Code
(NEC) Article 725 or Canadian Electrical Code (CEC) Section 16.
Mark Levinson
One balanced and one single-ended (unbalanced) connector is
available for each audio channel input.
Audio Channel Inputs
Single-Ended Inputs
The RCA connectors accept single-ended signals from preamplifiers
with singled-ended (RCA) outputs. A small toggle switch is
provided to select either the balanced (XLR) or single-ended (RCA)
input connector on each channel.
If your preamplifier does not support a balanced connection to the
power amplifier, connect the single-ended output to the RCA input
on the amplifier. Make sure the toggle switch is set to the position
closest to the RCA connector.
Push
Pin 2
Pin 1
Pin 3
Balanced Inputs
Accepts a signal from a preamplifier with balanced outputs via the
high quality XLR connector. Make sure the toggle switch is set to
the position closest to the XLR connector.
Balanced (female XLR)
Input Connector
Pin Assignments:
Pin 1: Signal Ground
Pin 2: Signal + (non-inverting)
Pin 3: Signal - (inverting)
Connector Shell - Chassis Ground
The pin assignments, shown on the left, of the XLR-type female
input connector are consistent with the standards adopted by the
Audio Engineering Society. Refer to the operating manual of your
preamplifier to ensure that the pin assignments of its balanced
output connectors correspond to the Mark Levinson power
amplifier. If not, wire the cables so that the appropriate output pin
connects to the equivalent input pin.
8
The Nº531H, 532H and 533H utilize custom-made, gold-plated,
high-current loudspeaker binding posts, two for each output
channel. The Nº535H uses different high-current binding posts
due to space constraints. The positive binding posts, labeled +
(positive), are red; the negative binding posts are black and are
labeled – (negative).
Loudspeaker Binding
Posts
Note
Ensure when connecting the loudspeaker that at least one positive and
one negative binding post is used. There is NO ground reference.
Caution!
Be careful to not short the positive and negative outputs
together. Do not short the positive or negative outputs to chassis
or any other safety ground. The amplifier must be powered off
during installation and whenever input and/or output cables are
being connected.
Nº500H Series Power Amplifier
Banana plugs can also be used to connect the speaker cables to the
loudspeaker binding posts. Banana plugs are not available on the
230 VAC model.
Caution!
DO NOT OVERTIGHTEN the binding posts. The innovative
design of these binding posts provides more leverage; hence,
high-contact, tight pressure connections are achieved when
finger-tightened.
DO NOT FORCE the binding post “wings” over a bent or
oversized connector. Doing so may damage the binding post.
Trigger Input and
Output
The rear panel of the amplifier has two trigger connectors – one
input and one output. The trigger input can receive a 3-12V
DC signal from a connected component. The trigger output
passes through the trigger input signal, enabling a daisy-chain of
amplifiers to be controlled by a single trigger signal.
The triggers enable the power amplifier to be automatically
powered on or put into Standby mode, by the state of other devices
in the system. The trigger output can also affect other power
amplifiers in the same manner.
9
Receiving a trigger signal causes the amplifier to change its power
state. If the amplifier is powered on, then 0V on the trigger signal
puts the amplifier into Standby or mode. Conversely, an amplifier
in Standby mode is powered on when 3-12VDC is received on the
trigger input.
Ethernet Port
The Ethernet port is a standard 10Base-T connection for use with
external control and networking. The Nº500H series supports
connection to a router or network, and to a PC-compatible
computer.
This connection is designed for use with proprietary Mark Levinson
external controllers, such as ML Net, or can provide serial port
control. For a list of the serial commands available, refer to the
separate document, No. 5 series Power Amplifier Serial Protocol
Definitions.
AC Input
Caution!
Provides AC power to the amplifier when the supplied power cord
is connected from the AC Input connector on the rear panel to an
electrical outlet.
Before operating the amplifier, verify that the voltage label
near the AC input connector indicates an operating voltage
compatible with the voltage level of the electrical outlet you
intend to use.
Mark Levinson
Network Setup
The Nº500H series power amplifier supports a network connection
through the Ethernet port. The Nº500H series can connect to a
network through use of a router or directly to a computer.
The Nº500H series can be:
1. Connected to a router with DHCP active – We highly
recommend using this option. Since the DHCP (Dynamic Host
Configuration Protocol) automatically assigns the IP (Internet
Protocol) addresses, setup is much simpler.
2. Connected to a router with DHCP not active – This method
requires more advanced networking knowledge to set up
because it uses fixed static IP addressing.
3. Connected directly to a computer with no router – We
recommend only using this option when a router is not
available. This method requires more advanced networking
knowledge to set up because it uses fixed static IP addressing
and a special network crossover cable.
This section provides general instructions for all three methods.
10
The following materials are required to connect the Nº500H series
to the network with a router:
Material Requirements
•
•
•
•
Nº500H series power amplifier
Two twisted-pair network cables
PC-compatible computer with 10/100Base-T network card
10/100Base-T router
The Nº500H series does not support wireless connection. However, a
cable attached from the amplifier to a wireless adapter can be used to
interface with a wireless network.
Note
The following materials are required to connect the Nº500H series
to a computer without the use of a router:
•
•
•
Nº500H series power amplifier
Network crossover cable
PC-compatible computer with 10/100Base-T network card
Nº500H Series Power Amplifier
The PC-compatible computer used to connect to the Nº500H series
must have the following software installed:
Computer
Requirements
•
•
Windows® 2000 or Windows XP®
Web browser (Microsoft® Internet Explorer® 6.0 or higher
preferred)
Note
If DHCP is not active, the computer must be set up with a Static IP
address. Refer to the “Setting Up the Computer” procedure found later
in this section for instructions.
Connecting the Cables
The Nº500H series can be connected to the computer in two
ways – through a router or directly to the computer. Before
connecting the cables, ensure that the computer and the amplifier
are powered down.
To Connect Using a Router:
Router
11
Computer
Amplifier
1. Connect a network cable from the router to the Ethernet port
on the rear panel of the amplifier.
2. Attach a second network cable from the router to the Ethernet
port of the computer.
To Connect Without a Router:
Use a network crossover cable to connect the amplifier directly
to the computer. Different from a standard network cable, the
crossover cable is designed to connect network access ports directly
together without a hub, router, or switch.
Crossover
Cable
Computer
Amplifier
Connect the crossover cable from the Ethernet port on the rear
panel of the amplifier to the Ethernet port of the computer.
Mark Levinson
When connected to a computer, the Nº500H series has an internal
Web page that provides access to:
Internal Web Page
•
Network Setup – allows the user to modify the network setup
parameters. Accessing the internal Web page is the ONLY way
to modify the network setup parameters of the Nº500H series
amplifier.
•
•
Status Information – provides basic status information of
the Nº500H series amplifier.
Error Reporting – tracks system-related error messages for
the Nº500H series amplifier. This page is a diagnostics tool for
Mark Levinson Customer Service use.
The amplifier MUST be connected to a computer via the Ethernet
port before you can access the internal Web page. Continue to the
next section – “Network Setup” – for further instructions.
The Web page also has a Restore Defaults button, which resets the
parameters to their factory default values. Clicking the Restore
Defaults button displays a pop-up asking for confirmation; click Yes
to restore the factory default values.
12
Accessible only through the Nº500H series internal Web page, the
network setup parameters include:
Network Setup
Parameters
•
Static IP Address – provides a fixed IP address. This IP
address is NOT automatically selected; it must be entered.
If DHCP is on, then this parameter is not used. IP address
192.168.50.5 is the factory default value for the Nº500H series.
Nº500H Series Power Amplifier
•
•
Subnet Mask – identifies the subnet mask for the Nº500H
series. This IP address is automatically assigned by DHCP.
If DHCP is off, then the address must be entered manually
and must agree with the subnet mask address of the router.
IP address 255.255.255.0 is the factory default value for the
Nº500H series.
Host Name – indicates the network name given to the
Nº500H series amplifier. This host name is unique to each
amplifier and is comprised of two parts, separated by an
underscore. The first part contains one to eight characters that
can be modified via the internal Web page of the amplifier.
The second part of the host name contains the last six
characters of the MAC address. This MAC address is unique to
each Nº500H series amplifier. The default is “NO500H_xxxxxx”
where “x” stands for the last six characters of the unique MAC
address for that amplifier.
•
DHCP – turns the DHCP capability on or off. When activated,
DHCP assigns a unique IP address to the Nº500H series. The
factory default value is On. We recommend leaving DHCP set
to On.
Connecting With
DHCP
Use this procedure if you are using a router with DHCP active to
connect to the amplifier. Otherwise, skip to the next procedure.
13
(Recommended)
1. Connect the amplifier to the router, as described in the earlier
“Connecting the Cables” procedure. Make sure that everything
is powered off before making cable connections.
2. Turn on the PC and router. Verify that the router has DHCP
active.
3. Press the Power button on the amplifier.
4. On the computer, open the Internet Explorer Web browser.
The “x” characters stand for the last six characters of the
unique MAC address for that amplifier.
6. Press Enter.
If Internet Explorer is unable to find the amplifier, then you
must find the IP address that was assigned to the amplifier by
the router. If required, refer to your router’s owner’s manual
for further details. Repeat this step using the IP address for the
amplifier that was assigned by the router.
7. The Home tab of the amplifier’s internal Web page is now
displayed. The tab is in red text to indicate that it’s the current
page.
The network connection is now complete.
Mark Levinson
If DHCP is not used, then the computer must be set up too. Use
Setting Up the
Computer
this procedure to set up the computer, then continue to the next
procedure to connect to the amplifier. For the computer to find
the amplifier, the LAN (Local Area Network) and TCP/IP (Internet
Protocol) settings of the computer must be set up. The parameter
setups vary slightly depending upon the operating system of the
computer. Refer to the procedure below that matches the operating
system on your computer.
Note
Due to your preference settings in the Windows operating system,
the names and order of the dialog boxes may vary slightly from these
instructions.
Network Setup for Windows XP
1. From the Start menu, select Control Panel.
2. Double-click on the Network Connections option.
3. Double-click on the Local Area Connection option.
4. Click the Properties button to open the Local Area Connection
Properties menu. If the computer is not currently connected
to an active network, Step 3 has already opened the Local Area
Connection Properties menu.
14
5. Click on the Internet Protocol (TCP/IP) line item so that it is
highlighted.
6. Click the Properties button.
7. Select the “Use the following IP address” option. The IP
address, Subnet mask, and Default gateway boxes are no longer
grayed out and can now be modified.
8. Enter the following values:
•
IP address: 192.168.50.x – where x stands for a number
other than 0, 3, 4, 5 or 255
•
•
Subnet mask: 255.255.255.0
Do not enter a value in the Default gateway parameter
The computer must have a unique address and be on the same
subnet as the amplifier.
9. Click “OK” to save and exit the menu.
10. Open the Internet Explorer Web browser.
11. From the menu bar, select the Tools Internet Options menu.
12. Select the Connections tab.
13. Click the LAN Settings button.
14. Verify that “Use a proxy server for your LAN” is NOT checked.
15. Click “OK” to save and exit the menu.
Nº500H Series Power Amplifier
Network Setup for Windows 2000
1. From the Start menu, select Settings Control Panel.
2. Double-click on the Network and Dial-Up Connections option.
3. Double-click on the Local Area Connection option.
4. Click the Properties button to open the Local Area Connection
Properties menu. If the computer is not currently connected
to an active network, Step 3 has already opened the Local Area
Connection Properties menu.
5. Click on Internet Protocol (TCP/IP) line item so that it is
highlighted.
6. Click the Properties button.
7. Select the “Use the following IP address” option. The IP
address, Subnet mask, and Default gateway boxes are no longer
grayed out and can now be modified.
8. Enter the following values:
•
IP address: 192.168.50.x – where x stands for a number
other than 0, 3, 4, 5 or 255
•
•
Subnet mask: 255.255.255.0
Do not enter a value in the Default gateway parameter
The computer must have a unique address and be on the same
subnet as the amplifier.
15
9. Click “OK” to save and exit the menu.
10. Open the Internet Explorer Web browser.
11. From the menu bar, select the Tools Internet Options menu.
12. Select the Connections tab.
13. Click the LAN Settings button.
14. Verify that “Use a proxy server for your LAN” is NOT checked.
15. Click “OK” to save and exit the menu.
Connecting With
Static IP Addressing
Use this procedure if you plan to connect with static IP addresses
(DHCP is turned off). Otherwise, skip to the next procedure to
connect directly to a computer. For the computer to find the
amplifier, the TCP/IP and LAN settings of the computer must be set
up. Refer to the previous “Setting up the Computer” procedure for
instructions.
1. Connect the amplifier to the router, as described in the earlier
“Connecting the Cables” procedure. Make sure that everything
is powered off before making cable connections.
2. Turn on the PC and the router. Verify that the router has DHCP
turned off, if required.
Mark Levinson
3. Set up the router to the IP address 192.168.50.x – where x
stands for a number other than 0, 3, 4, 5, 255, or the number
used for the computer IP address. The router must be on the
same subnet as the amplifier and the computer, but also must
have its own unique address. Refer to the router’s owner’s
manual for instructions on how to modify the IP address.
4. Press the Power button on the amplifier.
5. On the computer, open the Internet Explorer Web browser.
6. On the address (URL) line, type in the static IP address of the
amplifier Web page loads.
7. The Home tab of the amplifier’s internal Web page is now
displayed. The tab is in red text to indicate that it is the current
page.
8. Observe that the Status section of the Web page identifies the
host name of the amplifier. The host name can be modified,
but only the first eight characters are affected; anything after
the underscore may not be modified.
To change the host name of the amplifier:
A. Type the new name into the white box to the right of the
parameter. The new name must be made from the capital
letters, A to Z, and the numbers, 0 to 9. Underscores may
also be used. Only eight characters are allowed.
16
Note
The host name MUST start with an alpha-character (A to Z). This is a
standard networking rule.
B. Click the Submit button to save the new value.
C. Click the Refresh button in the Status section of the Web
page to observe the new host name.
9. Observe that the Status section of the Web page also identifies
the IP address of the amplifier. The static IP address can be
modified, if desired.
To change the IP address of the amplifier:
A. Type the new IP address into the white box to the right of
the parameter.
B. Click the Submit button to save the new value.
C. Enter the new IP address of the amplifier into the
browser. The amplifier Web page loads, reflecting the new
information.
The network connection is now complete.
Nº500H Series Power Amplifier
Use this procedure to connect directly to a computer if you are not
using a router. For the computer to find the amplifier, the TCP/
IP and LAN settings of the computer must be set up. Refer to the
earlier “Setting up the Computer” procedure for instructions.
Direct Connection
1. Connect the amplifier to the computer, as described in
the earlier “Connecting the Cables” procedure. Make sure
that both the amplifier and the computer are powered off
before connecting.
2. Press the Power button on the amplifier.
3. On the computer, open the Internet Explorer Web browser.
4. On the address (URL) line, type in the static IP address of the
amplifier Web page loads.
5. The Home tab of the amplifier’s internal Web page is now
displayed. The tab is in red text to indicate that it is the
current page.
6. Observe that the Status section of the Web page identifies the
host name of the amplifier. The host name can be modified,
but only the first eight characters are affected; anything after
the underscore may not be modified.
17
To change the host name of the amplifier:
A. Type the new name into the white box to the right of the
parameter. The new name must be made from the capital
letters, A to Z, and the numbers, 0 to 9. Underscores may
also be used. Only eight characters are allowed.
Note
The host name MUST start with an alpha-character (A to Z). This is a
standard networking rule.
B. Click the Submit button to save the new value.
C. Click the Refresh button in the Status section of the Web
page to observe the new host name.
7. Observe that the Status section of the Web page also identifies
the static IP address of the amplifier. The static IP address can
be modified, if desired.
To change the IP address of the amplifier:
A. Type the new IP address into the white box to the right of
the parameter.
B. Click the Submit button to save the new value.
C. Enter the new IP address of the amplifier into the
browser. The amplifier Web page loads, reflecting the
new information.
The network connection is now complete.
Mark Levinson
ML Net
The ML Net protocol allows you to control two or more Mark
Levinson products simultaneously via the Ethernet port.
Since ML Net operates through the use of a router and the Ethernet
connection, all devices must have networking capability. Refer to
the previous section of this manual, “Network Setup,” to set up the
Nº500H series for network operation.
Note
ML Net uses a single “Master” device to control specific functions
of other ML Net-capable Mark Levinson products. An ML Net
system can only have one Master device; all other devices in the
system become “Slaves”. Slave devices receive and respond to the
commands of the master device.
Masters and Slaves
The Nº500H series power amplifier is always a slave device. A
separate master device must be used in conjunction with the
Nº500H series amplifier.
As a slave device, the amplifier responds to the following ML Net
commands sent from the master device:
18
•
Status Reporting – status conditions of the Nº500H
series slave(s) are reported to the master device; status
includes Temperature, Session Time, Total On Time, and
Fault Reporting.
•
•
Standby State – the master device controls the Standby state
of the amplifier.
Synchronized LEDs – the Standby LEDS of the master device
and all assigned slave devices blink in unison.
After configuring each device on the network, connect all of the
devices together. Ensure that all components are powered off or in
Standby mode before connecting to the Ethernet ports.
Connecting the
Devices
Each device must be connected to the same network and use the
same subnet. Refer to the “Network Setup” section for instructions
on how to connect the Nº500H series to the network.
If more devices are desired than the router can handle, connect the
additional devices first to a switch, then connect the uplink of the
switch to a normal port on the router.
Nº500H Series Power Amplifier
The figure below illustrates a typical ML Net setup:
Nº532 Media Console
(Master)
Nº500 Series
Power Amplifier #4
(Slave)
Router
Nº500 Series
Power Amplifier #1
(Slave)
Nº500 Series
Power Amplifier #3
(Slave)
Nº500 Series
Power Amplifier #2
(Slave)
Discovering Slaves
Status Reporting
Before the master device can control any slave device, the slave
devices must be “discovered” and assigned to the master device.
Refer to the Owner’s Manual of the designated master device for
further information about discovering and assigning slave devices.
19
The Nº500H series slave(s) can report the following status
information to the master device:
•
•
•
Temperature – the current operating temperature of the
amplifier(s).
Session Time – the amount of time that the amplifier(s)
has been powered on.
Total On Time – the total amount of hours that the
amplifier(s) has been powered on since its manufacture.
If a slave device is inactive, unassigned, or assigned to a different
master, then status information is not available.
Fault Reporting
The Nº500H series slave(s) also reports fault information to the
master device. If a slave device is inactive, unassigned, or assigned
to a different master, then error reporting is not available. For more
information about possible fault conditions, refer to the
“Troubleshooting” section of the manual.
Mark Levinson
Troubleshooting
Incorrect operation is sometimes mistaken for malfunction. If
problems occur, use this section for troubleshooting information. If
problems persist, contact your authorized Mark Levinson dealer.
1. Examine the power cord to ensure that it is connected to both
the rear panel connector of the amplifier and an electrical
outlet.
No Power
2. Make sure the amplifier is powered on with the Power switch.
3. Make sure the amplifier is not in Standby mode. The front
panel LED should be at full brightness.
4. Examine the electrical circuit breaker to ensure that power
is being supplied to the electrical outlet to which the amplifier
is connected.
5. Verify that the voltage rating on the rear panel of the amplifier
matches the voltage rating of the electrical outlet. If the
voltages do not match, no power is sent to the outputs of
the amplifier.
1. Make sure that the source device is powered on, playing audio,
and set to the right output connector.
No Output
20
2. Examine cables to ensure a solid connection between the
amplifier and associated components.
3. Make sure the amplifier's output connectors are connected to
operational loudspeakers.
4. Ensure that the amplifier is not in a fault condition. When the
amplifier experiences a fault, the output is muted and the Status
LED on the front panel blinks in a rapid pattern, indicating:
LED Behavior
Description
Rapidly blinking
(on most of the time)
Indicates that a power-related fault has
occurred.
Rapidly blinking
(on half of the time)
Indicates that a signal-related fault* has
occurred.
Rapidly blinking
(off most of the time)
Indicates that a thermal-related fault has
occurred.
*Signal-related faults include significant DC offset at the output due to either DC in the input
signal or a failed component within the amplifier OR excessive current demands due to a
short-circuited loudspeaker wire.
You must assign the slave from the master device. Verify that the
slave you want to assign is listed in the master device list and
check its current state. For further explanations on assigning slave
devices, refer to the owner’s manual of the master device.
Can’t Assign in ML Net
Nº500H Series Power Amplifier
1. Verify that the master device and the Nº500H series amplifier are
No Response to
Commands in ML Net
properly connected together with a router.
2. Verify that the Nº500H series amplifier’s network setup is correct.
Access to the internal Web page via a computer is required to
verify the network settings of the Nº500H series.
No Connectivity Via
Ethernet
•
•
Verify that the network cables are properly connected between
the router, switch, or hub and the amplifier. If connecting to
a computer, verify that the computer network cable is in the
correct port.
Verify the age of the router, switch, or hub. There may be
a communication issue with the Nº500H series and older
network devices. Power cycle the Nº500H series and use a
newer router, switch, or hub between the network and the
amplifier.
•
If connected directly to the computer, make sure a crossover
cable is used.
•
•
Verify that the router and computer have valid IP addresses.
Verify that the proxy server in the computer’s network setup is
disabled. An active proxy server can interfere with the software
upgrade procedure.
21
•
If the web browser cannot find the host name of the amplifier,
verify the following:
•
Ensure that the local DNS server is properly configured.
We recommend configuring the local DNS Server to “DNS
Forwarding” mode. To configure the DNS Server, refer to
the setup manual of the server.
•
•
If using a subdomain, enter the complete address into the
browser. For example, http://NO500H.yourhome.network.com
Enter the IP Address of the amplifier into the browser. For
1. Power-cycle the Nº500H series, waiting at least 10 seconds
between powering the amplifier off and on.
If All Else Fails...
2. Restore the default settings on the internal web page.
more information.
4. Contact your Mark Levinson dealer.
.
Mark Levinson
Fault Protection
The Nº500H series is designed to prevent damage to themselves
and associated components. These extensive features protect both
the critical circuitry of the amplifier itself and shield connected
loudspeakers from serious damage due to high-power levels.
Basic protections designed into the Nº500H series include fuses
on each amplifier channel to protect against excessive current
conditions, such as driving shorted outputs. Inrush limiting
prevents premature aging of the power supply components during
power-up; once the power supply has been charged, this feature
goes off-line until the amplifier is powered up again.
The Nº500H series actively monitors operating temperature, output
current demands and the presence of DC on the outputs. The
amplifier will shut down under any of these conditions and report
the fault via the front panel LED and over the Ethernet connection.
The amplifier must be shut down to clear the fault condition before
being powered back up.
22
ML Net Fault Conditions
The slave devices in an ML Net system can report fault conditions
to the master device. Fault condition reports are displayed on the
display of the master device when the fault occurs. Some faults
may cause the amplifier to enter Standby mode. Power-cycling the
amplifier clears the fault condition, providing the
fault condition no longer exists.
Some faults do not allow power to be reapplied to the amplifier until
the fault condition no longer exists to protect the amplifier from
damage.
Note
The fault conditions reported are:
•
•
•
•
Slave Device DC Offset – indicates that the Nº500H series
amplifier is experiencing a signal-related fault.
Slave Device Over Current – indicates that the Nº500H
series is experiencing an over-current condition.
Slave Device Over Temperature – indicates that the
Nº500H series amplifier is overheating.
Signal – indicates that the Nº500H series has experienced a
general signal fault.
Nº500H Series Power Amplifier
Restoring Factory Defaults
Pressing the Factory Default button on the internal Web page of
the amplifier resets all settings to their factory default values. If
the internal Web page is not available, there is also a key press
sequence available. Follow the instructions below to reset the
factory default settings from the front panel.
1. Power off the amplifier.
2. Press and hold the Standby button.
3. Press the Power button to turn on the power.
4. Keep holding down the Standby button until the front panel
LED blinks four times.
5. Release the Standby button.
Now reset to its factory default state, the amplifier will reinitialize.
Care & Maintenance
The Nº500H series amplifier requires routine care and maintenance
to ensure optimal performance. The bulleted items indicate
maintenance procedures that should be performed on a regular
basis.
23
Turn off the Nº500H series amplifier and unplug the rear
AC power cord before performing maintenance to the
amplifer.
Failure to perform the maintenance procedures included in this section
may void the manufacturer’s warranty and/or standard repair policies.
Note
•
•
To remove dust from the amplifier’s exterior surface, use a
feather duster or a low-pressure blower.
To remove dirt and fingerprints from the amplifier’s exterior
surface, use a soft, lint-free cloth. DO NOT use metal polish or
a cloth made with steel wool.
•
•
If needed, this cloth can be dampened with isopropyl alcohol.
DO NOT dampen the cloth with Benzene, acetone-based
cleaners, or other commercial cleaners.
Wipe the amplifier’s exterior surface in the same direction as
the grain of the brushed aluminum.
Caution!
DO NOT apply liquid directly to the amplifier’s exterior surface.
Doing so may damage electrical components.
Mark Levinson
Nº531H, 532H, 533H
Specifications
All specifications are subject to change without notice.
Input & Output Connectors
• one balanced XLR input per channel
• one unbalanced RCA input per channel
• one pair “Hurricane” loudspeaker outputs with banana-plug
sockets per channel (banana-plug socket not available on the
230 VAC models)
Control Connectors
Rated Output Power
• one Ethernet 10Base-T port
• one 3.5mm mono (tip/sleeve) mini plug trigger input, 3-12Vdc
• one 3.5mm mono (tip/sleeve) mini plug trigger output, 3-12Vdc
• 3-pin IEC standard power connector
20Hz to 20kHz at <0.5% THD, 300W per channel @ 8 Ω, full
output from 2.25Vrms
Frequency Response
Signal-to-Noise Ratio
Input Impedance
Voltage Gain
within 0.5dB from 10Hz to 20kHz
>85dB, reference level: 2.83 Vrms
60 kΩ (balanced); 30 kΩ (unbalanced)
26.8dB
24
Input Sensitivity
2.83Vrms output at 130mVrms input
Power Requirements
100V~, 120V~, 230V~, factory set for destination country
Nº531H: 300W; Nº532H: 600W; Nº533H: 900W
Dimensions*
• Height (with feet): 7.65" (19.4cm)
• Height (without feet): 6.97" (17.7cm)
• Width: 17.75" (45.1cm)
• Depth: 19.83" (50.4cm)
*See dimensions diagram on the next page.
Weight
• Net weight: Nº531H: 52.5 lbs (23.8kg)
Nº532H: 74.0 lbs (33.6kg)
Nº533H: 90.0 lbs (40.8kg)
• Shipping weight: Nº531H: 62.5 lbs (28.4kg)
Nº532H: 84.0 lbs (38.1kg)
Nº533H: 100.0 lbs (45.4kg)
Operating Environment
• Operating temperature: 0º to 35ºC (32º to 95ºF)
• Storage temperature: –30º to 75ºC (–22º to 167ºF)
• Relative humidity: 95% maximum without condensation
Nº500H Series Power Amplifier
Nº535H Specifications
All specifications are subject to change without notice.
Input & Output Connectors
• five balanced XLR inputs per channel
• five unbalanced RCA inputs per channel
• five pairs loudspeaker outputs with banana-plug sockets
per channel (banana-plug socket not available on the
230 VAC models)
Control Connectors
Rated Output Power
• one Ethernet 10Base-T port
• one 3.5mm mono (tip/sleeve) mini plug trigger input, 3-12Vdc
• one 3.5mm mono (tip/sleeve) mini plug trigger output, 3-12Vdc
• 3-pin IEC standard power connector
20Hz to 20kHz at <0.5% THD, 200W per channel @ 8 Ω, full
output from 1.84Vrms
Frequency Response
Signal-to-Noise Ratio
Input Impedance
Voltage Gain
within 0.5dB from 10Hz to 20kHz
>85dB, reference level: 2.83 Vrms
60 kΩ (balanced); 30 kΩ (unbalanced)
26.8dB
25
Input Sensitivity
Power Requirements
Dimensions*
2.83Vrms output at 130mVrms input
100V~, 120V~, 230V~, 1000W, factory set for destination country
• Height (with feet): 7.65" (19.4cm)
• Height (without feet): 6.97" (17.7cm)
• Width: 17.75" (45.1cm)
• Depth: 19.83" (50.4cm)
*See dimensions diagram on the next page.
Weight
• Net weight: 98.5 lbs (44.7kg)
• Shipping weight: 108.5 lbs (49.2kg)
Operating Environment
• Operating temperature: 0º to 35ºC (32º to 95ºF)
• Storage temperature: –30º to 75ºC (–22º to 167ºF)
• Relative humidity: 95% maximum without condensation
Mark Levinson
Declaration of Conformity
Application of Council Directive(s):
2004/108/EC and 2006/95/EC, as amended.
Standard(s) to Which Conformity Is Declared:
EN 55013:2001 + A1:2003 + A2:2006
EN 55020:2007
EN 61000-3-3:1995 + A1:2001 + A2:2005
EN 60065:2002
Manufacturer:
Harman International
1718 W. Mishawaka Road
Elkhart, IN 46517
The equipment identified here conforms to the Directive(s) and
Standard(s) specified above.
Type of Equipment:
Models:
Power Amplifier
Mark Levinson No.
531H, 532H, 533H, 535H
March 2009
Date:
26
|