Upholstered Back
Upholstered Armrest
Upholstered Seat
Upholstered Legrest
Padded Push Handle
Upholstered Footrest
Drop Arm
Telescoping Tubes
Front Casters
with Tread
Lock
Rear Swivel Locking
Casters with Tread lock
Drop Arm Pull Button
(Behind Table)
Frame
Trendelenburg Release Bar
Fold Down Side Tables
To Operate Drop Arm
To Drop Arm:
To Raise Arm:
1. Lift fold down Side table away from frame to 1. Grasp armrest with one hand and pull upwards
expose button.
2. Pull button out while gently pushing down on
while pulling pull button out. Pull up on arm
evenly until pull button locks into place.
center of armrest until arm is in the full down 2. Ensure arm is secure by pushing down on
position. center of armrest.
566DG Ortho Biotic Clinical Care® Recliner Operating Instructions
3
UPHOLSTERED BACK ASSEMBLY
1. Lift the skirt on the rear of the upholstered
upholstered back "KD Brackets". The top of
bayonet link should be even with top of KD
Bracket. (See fig. 1)
back, fasten skirt up with a small piece of
tape to fully expose the "KD Bracket" that are
to be mated to the recliner mechanism.
4. Once back is properly seated onto
mechanism insert the threaded knob thru
"bayonet link", 'ED Bracket" and steel tube.
Secure hand tight.
2. Carefully guide upholstered back onto the
mechanism inserting both "bayonet links" at
the same time thru cutouts in vinyl.
3. Push down on the back until the mechanism 5. Remove tape lower upholstery skirt and
"bayonet links" are properly engaged into the
secure to Velcro.
Upholstered Back
Upholstered Skirt
Threaded Knobs
Upholstered Back’s
KD Brackets
Steel Tube
Mechanism’s
Bayonet Links
Bracket and Link to be even
Threaded Knob thru large
hole in Bayonet Link
KD Bracket
Bayonet Link
4
566DG Ortho Biotic Clinical Care® Recliner Operating Instructions
CASTER OPERATION (FRONT)
Tread Lock Pedal
NOTE:This chair is equipped with four casters for
improved maneuverability. The front
casters are equipped with tread locks.
To Lock: Step on the back edge of the black
pedal until it latches and stays down.
Figure 5
To Unlock: Step on the top edge of the pedal.
To lock swivel
To unlock wheel
CASTER OPERATION (REAR)
NOTE:The chair is equipped with four casters for
improved maneuverability. Right rear
caster is also equipped with locking
features. Swivel lock will aid the chair in
rolling straight.
To lock wheel
Lock: To prevent the rear casters from swiveling
and wheel turning, step on the rear pedal of the
caster until it latches.
Figure 4
Table
(Disengaged Position)
Armrest
Unlock: Step on middle button to unlatch.
TABLE OPERATION
3/8 Clevis Pin
Attachment
To Raise: Raise table all the way up and slide in
toward the armrest until tabs engage slots in
mount bracket. Press down lightly on table to
ensure lock tabs are engaged.
Table
(Engaged
Position)
Table Mount
Bracket
Tabs engage into
slots on table
To Lower: Lift table up until tabs disengage slots
and pull table away from armrest. Lower table to
self-storing position.
Table
(Stored Position)
mount bracket
SIDE PANEL REMOVAL
Side Panel
To Remove: Grasp upholstered side panel at
back of panel and pull sharply out from chair
until locking clips release side panel.
To Install: Insert side panel into chair frame by
lining up side panel clips with tubes on frame
and pushing firmly.
Drop Arm Pull Button
(Behind Table)
566DG Ortho Biotic Clinical Care® Recliner Operating Instructions
5
SEAT POSITIONING
Reclining by Patient: Place hands on armrest
and push body against chair's back to recline
yourself to desired position. To bring yourself
up, place hands on armrest and pull yourself up
while leaning your body forward away from the
chairs back.
Reclining by Attendant: Standing on either side
of the chair, grasp the armrest with one hand
and push handle with the other hand. Push back
on push handle to recline and pull forward to
raise the chair.
Upright Position
Infinite Position Between TV and Full Recline
TV Position
TRENDELENBURG POSITION:
Standing on either side of the chair, grasp the
armrest with one hand while holding the recliner
back with the other. With your foot, push down
on the release bar while gently pushing down
with your hand on the recliners back until it
comes to a stop. To bring chair out of
Trendelenburg, stand on either side of the chair,
grasp the armrest with one hand and push
handle with the other hand and pull forward on
the push handle.
Trendelenburg Position