M A T E R I A L S A F E T Y D A T A S H E E T  
For Welding Consumables and Related Products  
Conforms to Workplace Hazardous Materials Information System (WHMIS) Rev. November, 1988  
Section I & II - Preparation and Product Information  
Covered Electrode  
Product Type:  
Products:  
Blue Max 308/308L AC-DC, 309/309L AC-DC,  
The Lincoln Electric Company of Canada LP  
179 Wicksteed Avenue  
316/316L AC-DC, 347 AC-DC, 2100  
Toronto, Ontario M4G 2B9 CANADA  
Phone: (416) 421-2600  
Prepared by The Lincoln Electric Company, Cleveland, Ohio, USA  
(216) 481-8100, on the date shown above.  
Section III - Hazardous Ingredients (1)  
I M P O R T A N T !  
This section covers the materials from which this product is manufactured. The fumes and gases produced during welding with the normal use of this  
product are covered by Section VII; see it for industrial hygiene information.  
CAS Number shown is representative for the ingredients listed. All ingredients listed may not be present in all sizes.  
(1) The term “hazardous” in “Hazardous Ingredients” should be interpreted as a term required and defined in the Hazardous Products Act and does not  
necessarily imply the existence of any hazard.  
TLV  
LD50  
LC50 mg/m3  
Ingredients:  
Mineral silicates  
CAS No. Wt. % mg/m3 (Route/Species) (Route/Species)  
590 g/kg LDLo  
1332-58-7  
13463-67-7  
7440-47-3  
1317-65-3  
1344-09-8  
65996-74-9  
7439-96-5  
7789-75-5  
14808-60-7  
7440-03-1  
7439-89-6  
7440-48-4  
7439-98-7  
554-13-2  
5-10  
5-10  
1-5  
5**  
Not Available  
Not Available  
Not Available  
Not Available  
Not Available  
(oral/rat) reproductive  
Titanium dioxides (as Ti)  
10  
Not Available  
2.16 mg/kg LDLo  
(intravenous/rat)tumorigenic  
Chromium and chromium alloys or compounds (as Cr)  
Limestone and/or calcium carbonate  
Silicates and other binders  
Iron oxides (as Fe)  
0.5(b)  
10  
1-5  
Not Available  
1153 mg/kg  
(oral/rat)  
1-5  
10*  
5
1-5  
Not Available  
9 g/kg  
(oral/rat)  
4250 mg/kg  
(oral/rat)  
Not Available  
2.3 LCLo  
(inhalation/human)  
Manganese and/or manganese alloys and compounds (as Mn)  
Fluorides (as F)  
0.1-1  
0.1-1  
0.1-1  
0.1-1  
0.1-1  
0.1-1  
0.1-1  
0.1-1  
0.2  
2.5  
Not Available  
300 LCLo  
(inhalation/human)  
200 mg/kg LDLo  
(intratracheal/rat)  
Quartz  
#0.05**  
10*  
10*  
.02  
Niobium alloys (as Nb)  
Iron  
(347 type only)  
(316 type only)  
Not Available  
Not Available  
Not Available  
Not Available  
Not Available  
Not Available  
Not Available  
6170 mg/kg  
(oral/rat)  
Cobalt  
114 mg/kg LDLo  
(intraperitoneal/rat)  
4111 mg/kg LDLo  
(oral/human)  
Molybdenum alloys (as Mo)  
Lithium compounds (as Li)  
10  
10*  
Stainless steel core wire  
Nominal core wire composition:  
Chromium  
60-100  
2.16 mg/kg LDLo  
(intravenous/rat)tumorigenic  
50 mg/kg LDLo  
7440-47-3  
7440-02-0  
7439-98-7  
7439-96-5  
7439-89-6  
20-30  
10-13  
2.5  
0.5(b)  
1.5  
Not Available  
Not Available  
Nickel  
(intravenous/mouse)  
114 mg/kg LDLo  
(intraperitoneal/rat)  
9 g/kg  
Molybdenum  
Manganese  
Iron  
(316 type only)  
10  
Not available  
2.3 LCLo  
(inhalation/human)  
2.0  
0.2  
(oral/rat)  
bal.  
10*  
Not Available  
Not Available  
Notes: (*) Not listed. Nuisance value maximum is 10 milligrams per cubic (LDLo, LCLo) Lowest published toxic concentration.  
meter. TLV value for iron oxide is 5 milligrams per cubic meter.  
(b) The OSHA PEL for chromium (VI) is 5 micrograms (0.005  
(**)  
(#)  
As respirable dust.  
milligrams) per cubic meter. The TLV for water soluble  
chromium (VI) is 0.05 milligrams per cubic meter and the  
TLV for insoluble chromium (VI) is 0.01 milligrams per  
cubic meter.  
Crystalline silica (quartz) is on the IARC (International Agency for  
Research on Cancer) and NTP (National Toxicology Program) lists  
as posing a carcinogenic risk to humans.  
Section IV - Physical Data  
Physical data such as odor, vapor pressure, density, evaporation rate and freezing or boiling points are not listed as they are not applicable to  
this product and its use.  
Section V - Hazard Data  
Non Flammable; Welding arc and sparks can ignite combustibles and flammable products. See CSA W117.2 Section 9.7 as referenced in  
Section VIII. Product is inert, no special handling or spill procedures required.  
Rev 11/06b  
(CONTINUED ON SIDE TWO)  
 
 

Kustom Stereo Amplifier WAV 212 User Manual
LG Electronics Refrigerator LSC27931 User Manual
LG Electronics Stereo System LHT874 User Manual
LST Network Card M512ME User Manual
Mackie Speaker SWA1801 User Manual
Marley Engineered Products Humidifier Class Cooling Tower User Manual
MB QUART Car Stereo System FX11000 User Manual
McCulloch Lawn Mower 966564101 User Manual
Mellerware Hair Dryer 2 0 1 0 0 User Manual
Metra Electronics Automobile Accessories 99 8218 User Manual