Lightolier Power Supply LUPS Series User Manual

LUPS Series Uninterruptible Power Supplies LUPS  
Page 1 of 2  
550 - 1,500 VA Sine Wave UPS System  
Operates incandescent, electronic ballast loads and HID lighting loads as well as critical loads requiring conditioned emergency power.  
31.0”  
16.6”  
42.2 cm  
78.7 cm  
550 VA  
223 lbs.  
(101 kg)  
1000 VA  
223 lbs.  
(101 kg)  
1500 VA  
262 lbs.  
(119 kg)  
Cabinet &  
Electronics  
Sealed Lead  
Calcium Battery  
39.0”  
99.1 cm  
10 Minute  
Backup  
44 lbs.  
(19.9 kg) (26.8 kg)  
59 lbs.  
88 lbs.  
(39.9 kg)  
20 Minute  
Backup  
54 lbs.  
(24.5 kg) (39.9 kg)  
88 lbs.  
108 lbs.  
(49.0 kg)  
90 Minute  
Backup  
121 lbs.  
(55 kg)  
203 lbs.  
(92 kg)  
288 lbs.  
(131 kg)  
How to Specify:  
LUPS  
Series  
VA Rating  
Voltage  
Output Circuit  
Breakers  
OCB1 = (550 VA)  
OCB3 = (1000, 1500 VA)  
Configuration  
Input Output  
A = 120 120  
B = 277 277  
LUPS = LUPS Uninterruptible  
Power Supply for  
550 = 550 VA  
1000 = 1,000 VA  
1500 = 1,500 VA  
Emergency Lighting  
Applications  
LUPSX = 10 Minute Backup  
LUPSY = 20 Minute Backup  
Overall Characteristics  
Electronics  
83% throughput efficiency  
Input  
Single conversion UPS, No transfer time  
Operating temperature range of 32°F (0°C) to 104°F (40°C); 65°F (19°C) to  
85°F (29°C) maximum for batteries  
Input power factor self-correcting to > 0.95  
Frequency 60.0 ±2.5 Hz  
Input voltage tolerance +10% to -15%  
Input harmonics < 8% THD  
Standard 90 minutes of operating time  
Full-time, isolating transformer  
Variable Range Regulator allows wider range of acceptable input voltage  
variation  
Output  
Solid-state PWM inverter with sine wave output  
Output voltage regulation ±3% of nominal at full load  
Output frequency 60 Hz ±0.2%  
Load power factor capability is 0.6 lagging to unity  
Overload rating: 125% for 10 minutes  
Efficiency: 82% to 86%  
ANSI/IEEE C62.41 category A & B surge voltage withstand capability  
Housing  
Free standing, NEMA 1 enclosure with locking doors  
Acid resistant powder coat finish  
Multiple conduit entries  
Charger  
Low voltage disconnect (LVD)  
3 amp, 2-stage  
Recharge time: UL 924 compliant  
Standard Metering/Controls  
AC input and output voltage  
AC input breaker  
AC output breaker  
Battery disconnect device  
Automatic battery monitor with alarm  
LED indicating lamps for system on, system on battery, low battery warning  
Options  
FSU = Start-up Service  
EXT = Extended Warranty (with FSU only)  
Battery  
Job Information  
Type:  
Maintenance free, sealed lead calcium battery has an estimated service life of  
10 years, and operating temperature range of 65°F (19°C) to 85°F (30°C)*.  
Job Name:  
Cat. No.:  
* Increases or decreases in temperature will affect battery performance. Optimum battery performance  
realized at 77°F (25°C). Batteries are rated at 100% capacity at 77°F (25°C).  
Lamp(s):  
Notes:  
Lightolier a Genlyte Company  
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710  
We reserve the right to change details of design, materials and finish.  
© 2006 Genlyte Group LLC (Lightolier Division) • C0406  
 

KTI Networks Switch KS 105F User Manual
Lenovo Tablet N3S2PUK User Manual
LG Electronics Flat Panel Television W1942TQ User Manual
LightSpeed Technologies Stereo Amplifier LES 600 Series User Manual
Magnavox Indoor Fireplace ME43BKSP User Manual
Makita Trimmer UH303D User Manual
Marantz DVD Player DV6500 User Manual
MartinLogan Indoor Fireplace 33ISDG User Manual
Mattel Baby Toy R5302 0920 User Manual
Maytag Clothes Dryer W10150661A User Manual