INSTRUCTION SHEET NO.
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
IS:1004ICV
B1204 Page 1 of 4
INSTALLATION PROCEDURE FOR LOW VOLTAGE
INSULATED CEILING FRAME-IN-KIT 1004ICV, 1004ICVN
NEW CONSTRUCTION
NOTE: I.C. Frame-in Kit may be used in direct contact with insulation.
Fig. B
Wire-In
Fig. C
Swing-Up
Fig. D
Close-In
Fig. E
Snap-On
Fig. F
Push-Up
Fig. A
Frame-In
WARNING: USE ONLY WITH LIGHTOLIER REFLECTOR TRIMS MARKED WITH I.C. LAMPING INFORMATION. USE OF OTHER
MANUFACTURERS’ TRIMS VOIDS THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD
1. FRAME-IN (Fig. A)
BEND AT HOLE
TAB
Locate fixture along joist and line up bottom edge of HINGED
MOUNTING BAR with the bottom of joist and fasten in place.
BEND AT TAB
5 5/8”
For suspended ceilings:
• Rotate HINGED BAR ENDS to position shown
CENTER LINE OF
APERTURE OPENING
and fully extend bars.
6”
• Crimp bottom of edge of CHANNEL to prevent
rotation of HINGED BAR ENDS.
• Bend NON-HINGED end of mounting bar at
featured hole location and extend out.
• Position notched area of MOUNTING BARS onto
Note: Integral nail version available
T-BAR and lock by bending TAB underneath
T-BAR BEAD as shown.
HINGED MOUNTING BAR
• For suspended ceiling, make certain that bottom
of Mounting Frame is no higher than 1” above
ceiling line.
T-BAR
HINGED BAR ENDS
CHANNEL
FOR JOIST SPACING LESS THAN 16” ON CENTER (TO 12” ON CENTER):
• MOUNTING BAR CHANNELS can be shortened and used as
nailing legs in tight spaces. Simply remove INNER BAR from
holed CHANNEL, bend CHANNEL at appropriate point and
use extra screw to secure it to the joist. (Fig. G)
TAB
Fig. G
®
LIGHTOLIER a GENLYTE company.
631 Airport Road, Fall River, MA 02720
INSTRUCTION SHEET NO.
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
IS:1004ICV
B1204 Page 3 of 4
Fig. H
MALE CONNECTORS
8. LAMPING (Fig. H)
INSULATING SLEEVING
(ATTACHED TO SOCKET WIRES)
1. Make sure that power is OFF when lamping or relamping.
Remove LAMP RING from TRIM by pulling straight down.
2. Remove LAMP SHIELD from LAMP RING.
3. Place LAMP SHIELD on back of LAMP (MR-16) and insert both
FEMALE CONNECTORS
(ATTACHED TO FIXTURE WIRES)
between LAMP SPRINGS until face of lamp sits firmly on GLASS LAMP
GUARD (Fig. J).
MR16 SOCKET
WARNING: RISK OF FIRE. LAMP SHIELD MUST BE INSTALLED.
Fig. J
4. Attach SOCKET to bi-pin prongs on LAMP.
LAMP
SOCKET
5. Insert LAMP RING with LAMP SHIELD, LAMP and GLASS LAMP
LAMP SHIELD
LAMP SPRING
GUARD back into TRIM.
LAMP RING
GLASS LAMP GUARD
WARNING: 1. LAMP MANUFACTURERS REQUIRE THE GLASS LAMPGUARD BE IN PLACE BEFORE ENERGIZING LAMP, AND THAT GREAT
CARE MUST BE TAKEN THAT LAMP IS FULLY COOLED BEFORE RELAMPING. AVOID FINGER MARKS ON INSIDE OF LAMP FOR THEY MAY
CAUSE SHORT LAMP LIFE AND POSSIBLE BREAKAGE. 2. USE ONLY REFLECTOR TRIMS PROVIDED BY LIGHTOLIER INC. USE OF OTHER
MANUFACTURER'S REFLECTOR TRIMS VOIDS THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD.
NOTE: 1. LOW VOLTAGE FIXTURES should be
dimmed only with special dimmers intended
specifically for that purpose. Use Lightolier
Lytemode, Scenist, Crescendo VA, Neptune VA,
Precision VA, Easyset VA, Sunrise VA, Radiant
VA or equivalent products by others or variable
autotransformers or electronic dimmers
intended for use with low voltage fixtures.
2. Low voltage fixtures may produce audible
sound which may be objectionable in acousti-
cally critical areas.
®
LIGHTOLIER a GENLYTE company.
631 Airport Road, Fall River, MA 02720
INSTRUCTION SHEET NO.
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
IS:1004ICV
B1204 Page 4 of 4
9. TRANSFORMER REPLACEMENT (Fig. K)
1. Make sure power is off.
2. Remove REFLECTOR TRIM from ceiling.
3. Remove SCREW and lift TRANSFORMER off bracket.
4. Remove J-BOX COVER by removing wing nut.
5. Unsplice primary leads in J-BOX.
PRIMARY
LEADS
6. Remove primary leads from J-BOX cover and clip attached to side
SECONDARY
(RED) LEADS
of housing.
7. Cut secondary (red) leads 6" to 8" from TRANSFORMER and dis-
card faulty transformer.
8. Install new TRANSFORMER:
CLIP SCREW
(WARNING: RISK OF FIRE. Transformer contains fixture thermal
protector. Replace as shown and described below. Use only
replacement transformer obtained from LIGHTOLIER.)
a. Splice secondary (red) leads to socket leads.
ROTO CLIPS
JUNCTION BOX
TRANSFORMER
MAX. OF (6) #12 AWG BRANCH
CIRCUIT CONDUCTORS SUITABLE
FOR AT LEAST 90° C PERMITTED
IN JUNCTION BOX.
PRIMARY: 120V, 60HZ
b. Attach TRANSFORMER to BRACKET with SCREW, making
sure that the side of transformer that has the wire leads is
facing the housing wall (Fig.L)
SECONDARY: 110V, 50W LOAD
Fig. K
c. Put primary leads through clip and bushing in the J-BOX
COVER.
e. Wire primary leads to supply leads.
f. Replace J-BOX COVER.
g. Install REFLECTOR TRIM.
WIRE LEADS
APERTURE
HOLE
HOUSING
WALL
TRANSFORMER
Fig. L
®