LOG PLACEMENT GUIDE
EDVPF, EDVST, EDVCL, EDVCR, EBVPF,
EBVST, EBVCL AND EBVCR SERIES
750,161M
REV. B 10/2004
LOG PLACEMENT GUIDE FOR LENNOX DIRECT VENT AND B-VENT SERIES
MULIT-OPEN GAS FIREPLACE HEATERS
GENERAL INFORMATION
This log placement guide has been prepared to present detailed log
placement illustrations and provide instruction to assist in the place-
ment of logs at the initial (new appliance) setup and after the annual
cleaning and inspection cycles. The information provided here is to
be used in conjunction with the Homeowner's Care and Operation In-
structions provided together with this document in the appliance lit-
erature packet. Please read the Homeowner's Care and Operation In-
structions completely before completing the procedures detailed in
this placement guide.
Figure 1
INITIAL INSTALLATION CONSIDERATIONS
If the logs are being installed for the first time, the following para-
graphs apply:
DO NOT attempt to install the logs until the appliance installation has
been completed, the gas line connected and tested for leaks and the
initial burner operation has been checked out.
Step 1. Remove the appliance front door.
Step 2. Remove the foamed log set from the interior of the firebox.
Remove the logs from their packaging. Handle logs carefully to pre-
vent breakage.
CERAMIC FLOOR PANELS, LOGS AND GLOWING EMBER
PLACEMENT
Glowing Embers
Step 1. Install the Ceramic Floor Panels as shown in Figure 3 (for
Direct Vent fireplaces only).
Figure 2
Note: This appliance is provided with enough Glowing Embers for sev-
eral applications, do not feel compelled to use all that is in a new bag.
For best glowing effect, replace the ember material annually. Replace-
ment Glowing Embers are available (Catalog Number 88L53).
Note: Do Not place Glowing Embers (Rockwool) over burner slots.
Step 3. Separate the Glowing Ember (Rockwool) into pieces about
the size of a quarter Figure 1. Keep the pieces fluffed up, not matted.
Distribute these pieces over the front surface of the burner, as shown
in Figure 2. Do not use more than is necessary. When properly posi-
tioned, the Glowing Embers will cover approximately 65% of the front
burner and with no appreciable gaps or openings. Ensure that the
main burner ports remain uncovered by the ember material.
Step 2. Position the individual logs as shown in Figures 4A and 4B
on pages 3 and 4. Logs should be placed in the order shown. All logs
that have notches to fit over the grate tines should be positioned with
these notches directly against the grate. Proper log placement is criti-
cal to encourage outstanding flame appearance and prevent sooting.
When positioned properly as shown, logs will be positioned between
flame peaks and will not impinge any flames.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
EDVPF, EDVST, EDVCL, EDVCR, EBVPF, EBVST, EBVCL & EBVCR LOG PLACEMENT
Log
Part
Number
6
4
2
Number Description
1
2
3
4
5
6
Log, Corner
55M1801
55M1901
55M2001
55M2101
55M2201
55M2301
Log, Rear/Left
Log, Front/Left
Log, Rear/Right
Log, Front/Center
Log, Center/Top
Catalog Number for the entire log set: 55M0401
1
3
5
Log (3) Lays Over
3
Logs 1 And 2
STEP 3
1
STEP 1
Place Bottom Hole Of Log (3) On Pin In Log (2). Position
Grooves At The Bottom Of Log (3) Over The Grate.
Position Groove At The
Bottom Of Log (1) Over
The Burner Log Support
Bracket
Position The Groove At The
Bottom Of Log (1) Over The
Grate And Slide It Forward
Against The Grate Here
Position And Slide Log (4)
1
Against The Back Of The Grate
STEP 4
Position Log (2) Over The Grate
Bar And Slide It Against The
Back Of The Grate Here
2
STEP 2
Place Log (4) Over
4
The Flat Spot On
Position Groove At The Bottom Of Log (2)
Over The Grate Here And Slide It Against
The Back Of The Grate
Log (1) Here
Figure 4A
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
3
EDVPF, EDVST, EDVCL, EDVCR, EBVPF, EBVST, EBVCL & EBVCR LOG PLACEMENT (CONTINUED)
Log
Part
Number
6
4
Number Description
2
1
2
3
4
5
6
Log, Corner
55M1801
55M1901
55M2001
55M2101
55M2201
55M2301
Log, Rear/Left
Log, Front/Left
Log, Rear/Right
Log, Front/Center
Log, Center/Top
Catalog Number for the entire log set: 55M0401
1
3
5
Position The Round End Of Log (6)
Against The Notch Of Log (4) Here.
Two Charred Spots Face The Front
Position Small End Of Log (6)
On The Notch Of Log (3) Here
6
STEP 5
3
4
Rest Log (5) Against
The Grate Here
Grate
Assembly
Position The Groove In The Back
Of Log (3) Against The Grate
Log (5) Sits In Front
Of The Grate
5
Figure 4B
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Lennox reserves the right to make changes at any time, without notice, in design,
materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local distributor for fireplace code information.
Printed in U.S.A. © 2003 by Lennox
P/N 750,161M REV. B 10/2004
1110 West Taft Avenue • Orange, CA 92865
|