WS-9046U
Wireless 433 MHz
Radio-controlled Weather Station
Instruction Manual
INVENTORY OF CONTENTS
1. The WS-9046U weather station (Figure 1).
2. One TX8U remote temperature/humidity sensor (Figure 2).
3. One TX15U wind speed sensor (Figure 3).
4. Mounting hardware
5. Instruction manual and warranty card.
OPTIONAL SENSOR (PURCHASE SEPERATELY)
•
Rain Sensor for rainfall information
Time LCD
Date LCD
Moon Phase LCD
Indoor LCD
Forecast LCD
Outdoor LCD
Wind Speed LCD
Rainfall LCD
Figure 1
Figure 3
Figure 2
2
ADDITIONAL EQUIPMENT (not included)
1. Three fresh AA 1.5V batteries for the indoor weather station.
2. Two fresh AA 1.5V batteries for the remote temperature/humidity sensor.
(The remote temperature/humidity sensor powers the wind speed sensor and the rainfall sensor so no
batteries are required.)
3. One Philips screwdriver for mounting.
ABOUT WWVB (Radio Controlled Time)
The NIST (National Institute of Standards and Technology—Time and Frequency Division) WWVB radio station is
located in Ft. Collins, Colorado, and transmits the exact time and date signal continuously throughout the United
States at 60 kHz. The signal can be received up to 2,000 miles away through the internal antenna in the Weather
Station. However, due to the nature of the Earth’s Ionosphere, reception is very limited during daylight hours. The
weather station will search for a signal every night when reception is best. The WWVB radio station derives its signal
from the NIST Atomic clock in Boulder, Colorado. A team of atomic physicists is continually measuring every second,
of every day, to an accuracy of ten billionths of a second per day. These physicists have created an international
standard, measuring a second as 9,192,631,770 vibrations of a Cesium-133 atom in a vacuum. For more information
on the atomic clock and WWVB please see the NIST website at
QUICK SET-UP GUIDE
Hint: Use good quality Alkaline Batteries and avoid rechargeable batteries.
1. Have the indoor weather station, remote temperature/humidity sensor and wind speed sensor 3 to 5 feet
apart.
2. Insert the telephone plug (RJ-11) from the wind speed sensor into the receptacle on the remote
temperature/humidity sensor.
3. Insert the telephone plug (RJ-11) from the rain sensor into the receptacle on the remote
temperature/humidity sensor (optional; sold separately)
4. Batteries should be out of both the indoor weather station and remote temperature/humidity sensor units
for 10 minutes.
5. Place the batteries into the remote temperature/humidity sensor first then into the indoor weather
station.
6. DO NOT PRESS ANY BUTTONS FOR 15 MINUTES.
In this time the indoor weather station and remote temperature/humidity sensor (and rain sensor if any) will start to talk
to each other and the display will show the indoor temperature/humidity, outdoor temperature/humidity and wind
speed. If the indoor weather station does not display all information after the 15 minutes please retry the set up as
stated above. After all information has been displayed for 15 minutes you can place your sensors outdoors and set
your time.
Important Notes on Set-up and Operation
•
The remote temperature/humidity sensor is both the source of power for both outdoor sensors and source of
transmission for all remote sensor data.
•
•
•
•
The remote temperature/humidity sensor should be placed in a dry, shaded area.
Fog and mist will not harm your remote temperature/humidity sensor but direct rain must be avoided.
Direct rainfall will not harm the wind speed sensor.
The remote temperature/humidity sensor has a range of 330 feet. Any walls that the signal will have to pass
through will reduce distance. An outdoor wall or window can have up to 30 feet of resistance and an interior wall
can have up to 20 feet of resistance. Your distance plus resistance should not exceed 330 ft. in a straight line.
The remote temperature/humidity sensor transmits a signal every minute. After the batteries have been installed,
the indoor weather station will search for the signal for a duration of 15 minutes. If there is no temperature or
humidity reading in the OUTDOOR LCD or wind speed in the WIND SPEED LCD after 15 minutes, make sure the
units are within range of each other, or repeat the battery installation procedure.
•
•
If a button is pressed before the indoor weather station receives the signal from the remote temperature/humidity
sensor, you will need to follow the battery installation procedure again.
To complete the set up of your new wireless weather station after the 15 minutes have passed please follow the steps
that follow in the Detailed Set-Up Guide.
3
DETAILED SET-UP GUIDE
BATTERY INSTALLATION
The first step to powering up the weather station is to insert the connector (RJ11) at the end of the wire attached to
the wind speed sensor to the remote temperature/humidity sensor. Please ensure when doing this that the connector
is inserted with the proper orientation. When seated properly you will hear the connector ‘click’ in place.
A. REMOTE TEMPERATURE/HUMIDITY
1. Remove the mounting bracket and humidity hood.
2. Remove the battery cover by sliding the cover down.
3. Observing the correct polarity install 2 AA batteries. The batteries will fit tightly (to avoid start-up
problems make sure they do not spring free).
4. Replace the battery cover by sliding upwards. Be sure battery cover is on securely.
5. Replace the humidity hood.
B. INDOOR WEATHER STATION
1. Remove the battery cover. To do this, insert a solid object in the space provided at the lower-central
position of the battery cover, then push up and pull out on the battery cover.
2. Observe the correct polarity, and install 3 AA batteries.
3. Replace the battery cover.
C. RAINFALL SENSOR (optional)
The optional Rain Sensor does not need batteries to operate. Simply insert the telephone plug (RJ-11) of
the rain sensor into the receptacle on the remote temperature/humidity sensor.
Note: Immediately after the batteries have been installed, the LCD (Liquid Crystal Display) will flash.
Within 15 seconds the indoor temperature, indoor relative humidity, and the weather icons (sun and
clouds) will be displayed. If not, remove batteries for 10 seconds and reinstall. If the outdoor
temperature is not displayed within four minutes, remove batteries from both units, wait 30 seconds,
and reinstall making sure to install batteries into the remote temperature sensor first. The time will
show -:-- and start searching for the WWVB signal. If it successfully receives the time signal (usually
at night), it will display the correct time (default time-zone is Eastern). You will need to adjust the time
zone to match your local time.
PROGRAM MODE
Programming Note: If 30 seconds are allowed to pass, or the WIND/SNZ button is pressed during the
programming mode, the unit will confirm/set the last information entered—the display will stop flashing and return
to normal time-date readings. If you don’t leave the program mode during the programming of sections IV through
XI, you can advance to step 4 of the next program setting. If you do leave the program setting (or want to
program a specific setting) follow each instructional step to program that setting.
I.
PROGRAMMING SEQUENCE AND DEFAULT SETTINGS
The programming sequence and default (factory) settings are as follows:
LCD Contrast
5
Time Zone
-5 (Eastern)
ON
Daylight Saving Time
Radio-controlled time
reception
ON
12/24-hour time
12
Time – Hour
Time – Minute
Year
12
:00
2003
Month
1
Day
1
Snooze
10 minutes
Temperature Format
Rainfall Unit
Forecast Sensitivity
°F
inch
2
4
II. FUNCTION KEYS
The function keys are located on the front of the unit directly below the LCD (Liquid Crystal Display).
ALM/+ key
SET key
OUT/MIN key
IN/HR key
WIND/RAIN/
SNZ key
III. SETTING THE LCD CONTRAST
1. Press and hold the SET button for 5 seconds.
2. “LCD” will show in the TIME LCD and the number setting will flash.
Note: There are 8 LCD contrast levels to choose from—“Lcd 0” is the lightest, and “Lcd 7” is the
darkest.
3. Press and release the ALM/+ button to select the level you desire.
4. Press and release the SET button to confirm and advance to the Time Zone setting.
IV. TIME ZONE SETTING
1. Press and hold the SET button for 5 seconds.
2. “LCD” will show in the TIME LCD and the number setting will flash.
3. Press and release the SET button again.
4. The time zone will flash in the DATE LCD.
5. Press and release the ALM/+ button to select your time zone.
Note: It is possible to select any time zone from –12 GMT to +12 GMT (for example to see the time
in another country)
TIME ZONES
GMT
Atlantic
Eastern
Central
Mountain
Pacific
0
-4
-5
-6
-7
-8
-9
-10
EST;
CST;
MST;
PST;
ALA;
HAW;
Alaska
Hawaii
6. Press and release the SET button to confirm and advance to the Daylight Saving Time setting.
V. DAYLIGHT SAVING TIME (DST) SETTING
1. Press and hold the SET button for 5 seconds.
2. “LCD” will show in the TIME LCD and the number setting will
flash.
3. Press and release the SET button twice.
4. “DST” will appear in the DATE LCD and either “ON” or “OFF” will
flash in the TIME LCD.
5. Press and release the ALM/+ button to select DST on or off.
5
Note: “DST OFF” indicates that the feature is off and the WWVB will not change times automatically.
“DST ON” indicates that the feature is on and the WWVB will change times automatically.
Note: Some locations (Arizona and parts of Indiana) do not follow Daylight Saving Time, and should
select “DST OFF”.
6. Press and release the SET button to confirm and advance to the radio-controlled time on/off
setting.
VI. RADIO-CONTROLLED TIME ON/OFF SETTING
1. Press and hold the SET button for 5 seconds.
2. “LCD” will show in the TIME LCD and the number setting will flash.
3. Press and release the SET button three times.
4. “RCC” will appear in the DATE LCD and “ON” or “OFF” will flash in the
TIME LCD.
5. Press and release the ALM/+ button to select radio-controlled time on
or off.
6. Press and release the SET button to confirm and advance to the 12/24-hour time setting.
VII. 12 OR 24 HOUR TIME SETTING
1. Press and hold the SET button for 5 seconds.
2. “LCD” will show in the TIME LCD and the number setting will flash.
3. Press and release the SET button four times.
4. “12h” or “24h” will flash in the DATE LCD.
5. Press and release the ALM/+ button to select 12 or 24-hour time format.
Note: When in the 12-hour format “P.M.” will appear to the left of the hour in the time LCD between
the hours of noon and midnight.
6. Press and release the SET button to confirm and advance to the time setting.
VIII.
TIME SETTING
There are two methods by which the time and date can be set:
A) Automatically via WWVB reception, or
B) Manually.
A. WWVB (Remote Control Time)
This method requires you to do nothing, except wait for the signal to be received, and to select a time
zone. Reception usually takes approximately 10 minutes during optimal conditions. The best conditions
for reception is at night, between midnight and 6:00 am—when there is less atmospheric interference. To
keep your time as accurate as possible, the indoor weather station conducts a WWVB search every night
between these hours, and overrides any manually set time. The WWVB tower icon (appearing in the
TIME LCD) will flash when a signal-search is in progress and a signal is being received, and will remain
steady when the signal has been received. If the WWVB time has not been received after 10 minutes of
battery installation, you may manually set the time or leave the time function alone (reception will occur
regardless).
B. MANUAL TIME SETTING
Note: When in the 12-hour format “P.M.” will appear to the left of the hour in the time LCD between
the hours of noon and midnight.
Note: Reception of the WWVB signal will automatically set the time. The reception of the signal will
override any programmed time.
1. Press and hold the SET button for 5 seconds.
2. “LCD” will show in the TIME LCD and the number setting will flash.
3. Press and release the SET button five times.
4. The hours digits will flash in the TIME LCD.
5. Press and release the ALM/+ button to advance the hours.
6. Press and release the SET button to confirm the hours setting and
advance to the minutes setting.
7. The minutes digits will flash in the TIME LCD.
8. Press and release the ALM/+ button to advance the minutes.
9. Press and release the SET button to confirm and advance to the year setting.
IX. SETTING THE YEAR, DAY AND MONTH
6
Note: Reception of the WWVB signal will also set the date and day. The reception of the signal will
override any programmed date and day.
1. Press and hold the SET button for 5 seconds.
2. “LCD” will show in the TIME LCD and the number setting will flash.
3. Press and release the SET button seven times.
4. The year will flash in the DATE LCD.
5. Press and release the ALM/+ button to advance the year.
6. Press and release the SET button to confirm the year and advance
to the month setting.
7. The month will flash in the DATE LCD.
8. Press and release the ALM/+ button to advance the month.
9. Press and release the SET button to confirm the month and
advance to the day setting.
10. The day of the month will flash in the DATE LCD.
11. Press and release the ALM/+ button to advance the day of the
month.
12. Press and release the SET button to confirm and advance to the snooze setting.
X. SETTING THE SNOOZE
1. Press and hold the SET button for 5 seconds.
2. “LCD” will show in the TIME LCD and the number setting will flash.
3. Press and release the SET button ten times.
4. “Sn” will appear in the DATE LCD and a number will be flashing next
to it.
5. Press and release the ALM/+ button to select the duration of the
snooze.
Note: The snooze can be set for 0 to 30 minutes in 5-minute increments. If 0 minutes is selected
pressing the WIND/SNZ button will deactivate the alarm and it will not come back on.
6. Press and release the SET button to confirm and advance to the temperature format setting.
XI. SELECTING °F OR °C
1. Press and hold the SET button for 5 seconds.
2. “LCD” will show in the time LCD and the number setting will flash.
3. Press and release the SET button eleven times.
4. Either ”°F” or “°C” will flash in the TIME LCD.
5. Press and release the ALM/+ button to select the temperature
format.
6. Press and release the SET button to confirm and advance to the rainfall unit setting.
XII.
XIII
SETTING THE UNIT OF RAINFALL (inch/ mm)
1. Press and hold the SET button for 5 seconds.
2. “LCD” will show in the time LCD and the number setting will flash.
3. Press and release the SET button twelve times.
4. Either ”inch” or “mm” will flash in the TIME LCD (bottom right corner)
5. Press and release the ALM/+ button to select the desired rainfall unit.
6. Press and release the SET button to confirm and advance to the forecast sensitivity setting.
SETTING THE FORECAST SENSITIVITY
Note: The forecast sensitivity can be adjusted to allow for areas
that have a higher or lower sensitivity to changing air pressure (for
example coastal areas have more pressure change than areas such
as southern Arizona).
The numbers correspond to the amount of air pressure change
necessary to trigger a change in the forecast icon. Areas that tend
to have more air pressure change would set the sensitivity to 3,
while areas that experience lower than normal air pressure change
would set the sensitivity to 1.
1. Press and hold the SET button for 5 seconds.
2. “LCD” will show in the TIME LCD and the number setting will
flash.
3. Press and release the SET button twelve times.
7
4. Either “1”, “2” or “3” will flash in the TIME LCD and the forecast icon and tendency arrows will
flash in the FORECAST LCD.
5. Press and release the ALM/+ button to select the forecast sensitivity
6. Press and release the SET button to confirm the forecast sensitivity and complete the
programming.
FEATURES OF THE WS-9046U
Radio-controlled
time icon
(indicates radio-
controlled time
turned on)
WWVB Tower
Icon (indicates
time reception)
Alarm icon
Current moon
phase display
Comfort Level
Indicator
Weather
Tendency
Arrow
Forecast
icon
Satellite icon
(indicates
outdoor
transmission)
Beaufort Scale
Wind Indicator
Wind Speed in mph
Gust / Wind Chill / Rainfall icon
I.
WEATHER FORECAST
The weather forecasting feature is estimated to be 75% accurate and is for the next 12 to 24 hours. The
weather forecast is based solely upon the change of air pressure over time. The WS-9046U averages past
air-pressure readings to provide an accurate forecast—creating a necessity to disregard all weather
forecasting for 12-24 hours after the unit has been set-up, reset, or moved from one altitude to another (i.e.
from one floor of a building to another floor). In areas where the weather is not largely affected by the change
of air pressure, the sensitivity setting should be set to 1. In areas where the air pressure changes more
rapidly (such as coastal areas) the sensitivity setting should be set to 3.
A. WEATHER ICONS
There are 3 possible weather icons that will be displayed in the FORECAST LCD:
Sunny—indicates that the weather is expected to improve (not that the weather will be sunny).
Sun with Clouds—indicates that the weather is expected to be fair (not that the weather will be sunny
with clouds).
Clouds with Rain—indicates that the weather is expected to get worse (not that the weather will be
rainy).
8
These icons indicate the expected weather change in the next 12 to 24 hours. The icon does not give
an exact prediction of the weather, however it should be viewed as a generalization of the expected
weather change (for example a “sunny” icon indicates the weather is expected to improve).
The weather icons change when the unit detects a change in air pressure. The icons change in order,
from “sunny” to “partly sunny” to “cloudy” or the reverse. It will not change from “sunny” directly to
“rainy”, although it is possible for the change to occur quickly. If the symbols do not change then the
weather has not changed, or the change has been slow and gradual.
B. WEATHER TENDENCY ARROWS
Other possible displays in the FORECAST LCD are 2 weather tendency arrows, one that points up
(on the left side of the LCD) and one that points down (on the right side of the LCD). These arrows
reflect current changes in the air pressure. An arrow pointing up indicates that the air pressure is
increasing and the weather is expected to improve or remain good, an arrow pointing down indicates
that the air pressure is decreasing and the weather is expected to become worse or remain poor. No
arrow means the pressure is stable.
II. INDOOR TEMPERATURE, HUMIDITY, AND COMFORT LEVEL INDICATOR
The current indoor temperature and relative humidity are displayed in the INDOOR LCD.
The comfort level indicator is located at the bottom left of the INDOOR LCD. The indicator will display a
happy face icon when the temperature is between 68°F and 79°F (20°C and 25.9°C), and the humidity is
between 45% and 64%. A sad face icon will be displayed when the temperature and humidity are outside the
mentioned ranges.
III. OUTDOOR TEMPERATURE AND HUMIDITY
The temperature and humidity received from the remote temperature/humidity sensor is viewed in the
OUTDOOR LCD.
IV. MINIMUM AND MAXIMUM TEMPERATURE RECORDS
The WS-9035U keeps a record of the MINIMUM and MAXIMUM temperature, and the time and date of their
occurrence, for both the indoor and outdoor modes.
A. VIEWING THE INDOOR TEMPERATURE RECORDS
2. Press and release the IN/HR button once. “MAX” appears to the right of the indoor temperature,
indicating that the maximum temperature (along with the humidity measured at that time) and the
time and date of occurrence are displayed. The maximum records will display for 30 seconds
before returning to the normal display mode.
3. Press and release the IN/HR button again (once while “MAX” is still displayed, twice otherwise).
“MIN” appears to the right of the indoor temperature, indicating that the minimum temperature
(along with the humidity measured at that time) and the time and date of occurrence are
displayed.
4. While “MIN” is still displayed press and release the IN/HR button again to return to the current
data display. Or you can wait 30 seconds, during either the minimum or the maximum readings,
and the unit will automatically return to current data readings.
B. VIEWING THE OUTDOOR TEMPERATURE RECORDS
1. Press and release the OUT/MIN button once. “MAX” appears above the outdoor temperature and
the LCD will flash, indicating that the maximum temperature, and the time and date of occurrence
are displayed. The maximum records will display for 30 seconds before returning to the normal
display mode.
2. Press and release the OUT/MIN button again (once while “MAX” is still displayed, twice
otherwise). “MIN” appears to the right of the outdoor temperature, indicating that the minimum
temperature and the time and date of occurrence are displayed.
3. While “MIN” is still displayed press and release the OUT/MIN button again to return to the current
data display. Or you can wait 30 seconds, during either the minimum or the maximum readings,
and the unit will automatically return to current data readings.
C. RESETTING THE MIMIMUM AND MAXIMUM RECORDS
To reset the INDOOR records:
1. Press and release the IN/HR button to select the record you wish to reset, either MAX or MIN.
9
2. Press and hold the SET button for 5 seconds.
3. The record is now reset and will show the current time in the TIME LCD and current indoor
temperature and humidity in the INDOOR LCD.
T o reset the OUTDOOR records:
1. Press and release the OUT/MIN button to select the record you wish to reset, either MAX or MIN
2. Press and hold the SET button for 5 seconds.
3. The record is now reset and will show the current time in the TIME LCD and current outdoor
temperature and humidity in the OUTDOOR LCD.
V. MOON PHASE
There are 12 moon phases shown on the indoor weather station; the black portion signifies the portion of the
moon visible in the sky. Thus, when the moon icon is all black, it is a full moon.
VI. VIEWING THE CURRENT, MAXIMUM AND MINUMUM DEW POINT
To view the current dew point:
1. Press and hold the OUT/MIN button for 5 seconds.
2. The OUTDOOR LCD will switch to show the dew point (DEW POINT will be visible in the upper
left corner of the OUTDOOR LCD).
To view the maximum and minimum dew point readings:
1. Press and release the OUT/MIN button.
2. The maximum or minimum value along with the time and
date it was recorded will be displayed (MAX or MIN will be
displayed below the words DEW POINT in the OUTDOOR
LCD).
3. After 30 seconds the display will automatically go back to
the normal display mode showing the current dew point
reading.
To reset the maximum or minimum dew point record:
While viewing either the maximum or minimum dew point record:
1. Press and hold the SET button for 5 seconds.
2. The record will now be reset and show the current time in the TIME LCD and dew point reading in
the OUTDOOR LCD.
To return to the outdoor temperature/humidity viewing mode:
1. Press and hold the OUT/MIN button for 5 seconds.
2. The OUTDOOR LCD will switch back to show the outdoor temperature and humidity (DEW
POINT will no longer be visible in the upper left corner of the OUTDOOR LCD).
VII. WIND SPEED, WIND CHILL, MINIMUM AND MAXIMUM VALUES
In the WIND SPEED LCD you can view the current wind speed and
gust. The wind speed is updated every 128 seconds with the average
wind speed of that time being displayed. The gust display is the
highest gust for the last 128-second period.
To view the current wind chill:
1. Press and release the WIND/RAIN/SNZ button.
2. The wind chill value will display at the bottom of the WIND SPEED LCD.
To view the maximum and minimum wind/wind chill values:
1. Press and hold the WIND/RAIN/SNZ button for 3 seconds.
2. The WIND SPEED LCD will now show the maximum wind.
3. Press and release the WIND/SNZ button again.
10
4. The WIND SPEED LCD will now show the maximum wind gust.
5. Press and release the WIND/RAIN/SNZ button.
6. The WIND SPEED LCD will now show the minimum wind chill.
7. Press and release the WIND/RAIN/SNZ button.
8. The WIND SPEED LCD will now show the maximum wind chill.
To reset the maximum and minimum wind/wind chill values:
1. Select the value you wish to reset by pressing and releasing the WIND/SNZ button.
2. Press and hold the SET button for 5 seconds.
3. The record will now be reset and show either 0.0 for max wind speed and wind gust or the current
wind chill in the OUTDOOR LCD.
To return to the normal viewing mode:
1. Press and release the ALM/+ button or
2. After 15 seconds the display will automatically return to the normal viewing mode.
VIII. BEAUFORT SCALE WIND SPEED
The Beaufort Scale wind meter is located at the top of the WIND
SPEED LCD. It corresponds to the average wind speed and not the
gust. On the following pages is a list of the Beaufort Scale and the
wind speeds it corresponds to.
Wind Speed
km/hr
fort Number
or Force
Description
Effects Land / Sea
mph
knots
Still, calm air, smoke
will rise vertically.
0
1
<1
<1
<1
Calm
Water is mirror-like.
Rising smoke drifts,
wind vane is inactive.
1-3
mph
1-5
kph
1-3
knots
Light Air
Small ripples appear
on water surface.
Leaves rustle, can
feel wind on your
face, wind vanes
begin to move.
4-7
mph
6-11
kph
4-6
knots
2
Light Breeze
Small wavelets
develop, crests are
glassy.
Leaves and small
twigs move, light
weight flags extend.
8-12
mph
12-19
kph
7-10
knots
3
Gentle Breeze
Large wavelets,
crests start to break,
some whitecaps.
Small branches
move, raises dust,
leaves and paper.
13-18
mph
20-28
kph
11-16
knots
4
5
Moderate Breeze
Fresh Breeze
Small waves
develop, becoming
longer, whitecaps.
Small trees sway.
19-24
mph
29-38
kph
17-21
knots
White crested
wavelets (whitecaps)
form, some spray.
Large tree branches
move, telephone
wires begin to
"whistle", umbrellas
are difficult to keep
under control.
25-31
mph
39-49
kph
22-27
knots
6
Strong Breeze
Larger waves form,
whitecaps prevalent,
11
spray.
Large trees sway,
becoming difficult to
walk.
32-38
mph
50-61
kph
28-33
knots
Moderate or Near
Gale
7
8
Larger waves
develop, white foam
from breaking waves
begins to be blown.
Twigs and small
branches are broken
from trees, walking is
difficult.
39-46
mph
62-74
kph
34-40
knots
Gale or Fresh Gale
Moderately large
waves with blown
foam.
Slight damage occurs to
buildings, shingles are
blown off of roofs.
47-54
mph
75-88
kph
41-47
knots
9
Strong Gale
High waves (6 meters),
rolling seas, dense
foam, Blowing spray
reduces visibility.
Trees are broken or
uprooted, building
damage is
considerable.
55-63
mph
89-102
kph
48-55
knots
Large waves (6-9
meters), overhanging
crests, sea becomes
white with foam, heavy
rolling, reduced
10
Whole Gale or Storm
visibility.
Extensive widespread
damage.
64-72
mph
103-117
kph
56-63
knots
Large waves (9-14
meters), white foam,
visibility further
reduced.
11
12
Violent Storm
Extreme destruction,
devastation.
Large waves over 14
meters, air filled with
foam, sea white with
foam and driving spray,
little visibility.
73+
mph
118+
kph
64+
knots
Hurricane
IX. RAINFALL MEASUREMENT
If you have purchase the optional Rain Sensor, the rainfall measurement can be viewed in the WIND
SPEED LCD, otherwise, the rainfall information will not be shown.
Simply press the WIND/RAIN/SNZ button to toggle between Wind and Rain display.
In the WIND SPEED LCD you can view also three kinds of rainfall measurements:
1. Rainfall volume in the past 1 hour;
2. Rainfall volume in the past 24 hours;
3. Total rainfall volume from starting the measurement
12
Rainfall 1 hour icon
Rainfall volume reading
Rainfall volume unit
Rainfall 24 hour icon
Total Rainfall icon
`
To view the current rainfall measurements:
Press and release the WIND/RAIN/SNZ button to toggle between GUST, WIND CHILL, 1 hour rainfall
volume, 24 hour rainfall volume and total rainfall volume.
To view the maximum rainfall measurements:
1. Press the WIND/RAIN/SNZ button and hold for 3 seconds to enter MAX WIND MODE.
2. Press the WIND/RAIN/SNZ button 4 times to 6 times to view the Max 1 hour rainfall, Max 24 hour
rainfall and Max total rainfall respectively.
Note:
1.
2.
3.
The Max 1 hour rainfall is maximum value among all the all 1hour rainfall readings
measured.
The Max 24 hour rainfall is maximum value among all the all 24hour rainfall readings
measured.
The Max total rainfall is accumulated rainfall volume from the commencement of
measurement, which is equivalent to the Max rainfall shown in the current rainfall
mode.
To reset the maximum rainfall measurements:
1. Press the WIND/RAIN/SNZ button and hold for 3 seconds to enter MAX WIND MODE.
2. Press the WIND/RAIN/SNZ button for times to select the max rainfall data to be reset.
3. Press and hold the SET button for 5 seconds to reset the MAX Rainfall data to zero value. The time of
record will be reset to the current time.
To return to the normal viewing mode:
1. Press and release the ALM/+ button or
2. After 15 seconds the display will automatically return to the normal viewing mode.
X. TIME ALARM
To set the time alarm:
1. Press and hold the ALM/+ button for 5 seconds.
2. The alarm time will begin to flash in the DATE LCD.
3. Press and release the IN/HR button to adjust the hour.
13
Note: When in the 12-hour mode and setting an alarm for a time between noon and midnight, “PM”
will appear to the left of the alarm time in the DATE LCD.
4. Press and release the OUT/MIN button to adjust the minutes.
5. Press and release the WIND/RAIN/SNZ button to confirm the setting or wait for 20 seconds and
the display will automatically return to the normal mode.
To activate the alarm:
1. Press and release the ALM/+ button to toggle between the alarm time
and the day and date.
2. When the alarm time and alarm icon are showing in the DATE LCD
the alarm is activated.
3. When the day and date are showing in the DATE LCD the alarm is
deactivated.
To activate the snooze:
1. While the alarm is sounding press and release the WIND/RAIN/SNZ button.
2. The snooze will be activated and the alarm will come back on after the selected time period.
MOUNTING
Note: Before permanently mounting ensure that the indoor weather station is able to receive WWVB signals
from the desired location. Also, extreme and sudden changes in temperature will decrease the accuracy of
the indoor weather station, and changes in elevation will result with inaccurate weather forecasting for the
next 12 to 24 hours. These changes will require a 12 to 24 hour wait before obtaining reliable data. To
achieve a true temperature reading, avoid mounting where direct sunlight can reach the remote
temperature/humidity sensor or indoor weather station. While the remote temperature/humidity sensor is
weather proof, avoid submersion in water or snow. We recommend that you mount the remote
temperature/humidity sensor on an outside North-facing wall. The sending range is 330ft—obstacles such as
walls, concrete, and large metal objects can reduce the range. Place both units in their desired location, and
wait approximately 15 minutes before permanently mounting to ensure that there is proper reception. The
indoor weather station should display a temperature and humidity in the OUTDOOR LCD and wind speed
(can be 0.0) in the WIND SPEED LCD within 4 minutes of setting up.
I.
THE REMOTE TEMPERATURE/HUMIDITY SENSOR
The remote temperature/humidity sensor can be mounted in several ways:
• With the use of screws
• Using adhesive tape
• Using nylon straps
A. MOUNTING WITH SCREWS
1) Remove the mounting bracket from the remote
temperature/humidity sensor.
2) Place the mounting bracket over the desired location.
3) Through the two screw holes of the bracket, mark the mounting
surface with a pencil.
4) Screw mounting bracket onto the mounting surface. Ensure that the screws are tight
against the bracket.
5) Insert the remote temperature/humidity sensor into the bracket.
B. MOUNTING WITH ADHESIVE TAPE
1) With a nonabrasive solution, clean and dry the back of the mounting bracket and the
mounting surface to ensure a secure hold. The mounting surface should be smooth and
flat.
2) Remove the protective strip from one side of the tape.
3) Adhere the tape to the designated area on the back of the mounting bracket.
4) Remove the protective strip from the other side of the tape.
5) Position the remote temperature/humidity sensor in the desired location, ensuring that the
indoor weather station can receive the signal.
C. MOUNTING WITH NYLON STRAPS
1) Remove the mounting bracket from the remote temperature/humidity
sensor.
2) Place two nylon straps through the slots on the mounting bracket.
3) Place the remote temperature/humidity sensor in your desired
mounting location.
4) Fasten the two nylon straps securely around the mounting location.
14
II. THE REMOTE WIND SPEED SENSOR
The remote wind speed sensor can be mounted two ways:
• With the use of screws
• Using nylon straps
• Using the U-shaped bolt
A. MOUNTING WITH SCREWS
1) Unlock the mounting bracket from the remote wind speed sensor leaving the wire going
through the bracket.
2) Place the mounting bracket over the desired location.
3) Through the two screw holes of the bracket, mark the mounting surface with a pencil.
4) Screw the mounting bracket onto the mounting surface.
Ensure that the screws are tight against the bracket.
5) Slide the remote wind speed sensor onto the bracket
making sure to lock it in place.
B. MOUNTING WITH NYLON STRAPS
1) Unlock the mounting bracket from the remote wind speed
sensor leaving the wire going through the bracket.
2) Place two nylon straps through the slots on the mounting
bracket.
3) Place the remote wind speed sensor in your desired location.
4) Fasten the two nylon straps securely around the mounting location.
5) Slide the remote wind speed sensor onto the bracket making sure to lock it in place.
C.
MOUNTING WITH THE U-SHAPED BOLT
1) Use the U-shaped bolt provided and thread it through each
of the holder holes.
2) Fix the holder to a mast by using the nuts provided.
III.
THE RAIN SENSOR (OPTIONAL)
1.
2.
3.
Securely mount the rain sensor onto a horizontal surface about 2-3 ft above the
ground and in an open area away from trees or other coverings. (Rainfall may be
reduced causing inaccurate readings.)
When securing into place, check that rain excess will not collect and store at the base
of the unit but can flow out between the base and the mounting surface (test by
pouring clean water).
After mounting the rain sensor, connect the cable to the thermo-hydro sensor at the
corresponding socket so power supply can be received and data be transmitted to
the base station.
Note: For testing purposes, very slowly pour a small amount of water into the rain sensor
funnel. This simulates the rainfall and rainfall reading will be received and displayed at the
base station for about 2 minute delay. (To clear this data on the base station, refer to the
resetting data section in “Rainfall Measurement”)
15
III. THE INDOOR WEATHER STATION
1) Fix a screw (not included) into the desired wall, leaving approximately 3/16 of an inch
(5mm) extended from the wall.
2) Place the indoor weather station onto the screw using the hanging hole on the backside.
3) Gently pull the indoor weather station down to lock the screw into place.
TROUBLESHOOTING
NOTE: For problems not solved, please contact La Crosse Technology.
Problem: No reception of WWVB time signal.
Solution: 1) Wait overnight for signal.
2) Be sure indoor weather station is at least 6 feet from any electrical devices, such as televisions,
computers, or other radio-controlled clocks.
3) Remove batteries for five minutes, reinsert and leave the unit alone overnight without pressing buttons.
4) If there are still problems, contact La Crosse Technology.
Problem: Hour is incorrect (minute and date are correct).
Solution: Be sure correct time zone and daylight saving time settings are selected.
Problem: The LCD is faint.
Solution: 1) Set the LCD contrast to a higher number.
2) Replace the batteries
Problem: No outdoor temperature/humidity and/or wind speed is displayed.
Solution: 1) Disconnect the cable from the remote wind speed sensor, then reinsert making sure the cable clicks in
place.
2) Remove all batteries, reinsert into remote temperature/humidity sensor first, then the indoor weather
station.
3) Place the remote temperature/humidity sensor closer to the display.
4) Be sure all batteries are fresh.
5) Place the remote temperature/humidity sensor and indoor weather station in position so the straight-line
signal is not passing through more than two or three walls.
Problem: Temperatures do not match if units are placed next to each other.
Solution: Each temperature/humidity sensor is manufactured to be accurate to within 2 degree plus or minus and
under normal conditions, so two sensors could be as much as 4 degrees different. However, the difference
can be exaggerated further because the sensors are designed for different working environments. The
indoor temperature sensor is less responsive to ambient air currents because of the shielding effect of the
display's case. In addition, the case can act as a heat sink to absorb and store heat from external sources
(i.e. handling of the case or radiant heat). Also, the much greater range of the remote temperature/humidity
sensor requires a different calibration curve than the indoor range. Error is usually greater at the extreme
ends of a range, making it harder to compare different ranges with different curves. Under non-laboratory
conditions, it is difficult to compensate for the above factors and obtain an accurate comparison.
MAINTENANCE AND CARE INSTRUCTIONS
•
•
Extreme temperatures, vibration, and shock should be avoided to prevent damage to the units.
Clean displays and units with a soft, damp cloth. Do not use solvents or scouring agents; they may mark the
displays and casings.
•
•
•
Do not submerge in water.
Immediately remove all low powered batteries to avoid leakage and damage.
Opening the casings invalidates the warranty. Do not try to repair the unit. Contact La Crosse Technology for
repairs.
16
SPECIFICATIONS
Weather data measuring range:
Indoor:
14.2°F to 139.8°F with 0.2°F resolution (0°C to 59.9°C with 0.1°C
resolution) “OFL” displayed if outside this range
Outdoor and dew point:
Wind chill:
-21.8°F to 157.8°F with 0.2°F resolution (-29.9°C to 69.9°C with 0.1°C
resolution) “OFL” displayed if outside this range
-21.8°F to 157.8°F with 0.2°F resolution (-29.9°C to 69.9°C with 0.1°C
resolution) “OFL” displayed if outside range
Indoor relative humidity measuring
range:
1% to 99% with 1% resolution (“- -” displayed if outside this range
Outdoor relative humidity measuring
range:
1% to 99% with 1% resolution (“- - “ displayed if outside this range
Wind speed measuring range:
Rain Volume Display
(only with Rain Sensor use):
0 to 111.8 mph (0 to 50 m/s)
1 hour and 24 hour rainfall: 0 to 999.9 mm with 0.1 mm resolution (0 to 39
inch with 0.02 inch resolution)
Total rainfall: 0 to 2499 mm with 0.1 mm resolution (0 to 98 inch with 0.02
inch resolution)
Weather data checking interval:
Indoor temperature checking interval:
Indoor humidity checking interval:
Outdoor temperature checking interval
(remote temperature/humidity sensor):
Outdoor humidity checking interval:
Wind speed checking interval:
Outdoor temperature, humidity and wind
speed reception (indoor weather station):
Transmission range:
Every 15 seconds
Every 20 seconds
Every 128 seconds
Every 128 seconds
Average of 128 seconds with highest gust
Every 128 seconds
330 feet (in open space)
Power Supply:
Indoor weather station:
3 x AA, IEC LR6, 1.5V
Remote temperature/humidity sensor:
Remote wind speed sensor:
Battery life cycle:
Recommended battery type:
Dimensions (H x W x D):
2 x AA, IEC LR6, 1.5V
Supplied by remote temperature/humidity sensor
Approximately 12 months
Alkaline
Indoor weather station:
9” x 4.62” x 1.25”
(227 x 117.4 x 31.2 mm)
5.4” x 2.25” x 2.25”
(137 x 56.2 x 56.2 mm)
7.5” x 2.2” x 2.2”
Remote temperature/humidity sensor:
Remote wind speed sensor:
(191.2 x 55.8 x 56 mm)
WARRANTY INFORMATION
La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing defects in materials and
workmanship.
This limited warranty begins on the original date of purchase, is valid only on products purchased and used in North America and
only to the original purchaser of this product. To receive warranty service, the purchaser must contact La Crosse Technology, Ltd
for problem determination and service procedures. Warranty service can only be performed by a La Crosse Technology, Ltd
authorized service center. The original dated bill of sale must be presented upon request as proof of purchase to La Crosse
Technology, Ltd or La Crosse Technology, Ltd’s authorized service center.
La Crosse Technology, Ltd will repair or replace this product, at our option and at no charge as stipulated herein, with new or
reconditioned parts or products if found to be defective during the limited warranty period specified above. All replaced parts and
products become the property of La Crosse Technology, Ltd and must be returned to La Crosse Technology, Ltd. Replacement
parts and products assume the remaining original warranty, or ninety (90) days, whichever is longer. La Crosse Technology, Ltd
will pay all expenses for labor and materials for all repairs covered by this warranty. If necessary repairs are not covered by this
warranty, or if a product is examined which is not in need or repair, you will be charged for the repairs or examination. The owner
must pay any shipping charges incurred in getting your La Crosse Technology, Ltd product to a La Crosse Technology, Ltd
authorized service center. La Crosse Technology, Ltd will pay ground return shipping charges to the owner of the product to a USA
address only.
Your La Crosse Technology, Ltd warranty covers all defects in material and workmanship with the following specified exceptions:
(1) damage caused by accident, unreasonable use or neglect (including the lack of reasonable and necessary maintenance); (2)
damage occurring during shipment (claims must be presented to the carrier); (3) damage to, or deterioration of, any accessory or
decorative surface; (4) damage resulting from failure to follow instructions contained in your owner’s manual; (5) damage resulting
from the performance of repairs or alterations by someone other than an authorized La Crosse Technology, Ltd authorized service
center; (6) units used for other than home use (7) applications and uses that this product was not intended or (8) the products
17
inability to receive a signal due to any source of interference.. This warranty covers only actual defects within the product itself, and
does not cover the cost of installation or removal from a fixed installation, normal set-up or adjustments, claims based on
misrepresentation by the seller or performance variations resulting from installation-related circumstances.
LA CROSSE TECHNOLOGY, LTD WILL NOT ASSUME LIABILITY FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR
OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT. THIS
PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC INFORMATION. THIS PRODUCT IS NOT A
TOY. KEEP OUT OF CHILDREN’S REACH.
This warranty gives you specific legal rights. You may also have other rights specific to your State. Some States do no allow the
exclusion of consequential or incidental damages therefore the above exclusion of limitation may not apply to you.
For warranty work, technical support, or information contact:
La Crosse Technology
2809 Losey Blvd. S.
La Crosse, WI 54601
Phone: 608.782.1610
Fax: 608.796.1020
e-mail:
(warranty work)
(information on other products)
web:
FCC DISCLAIMER
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause undesired operation.
FCC ID: OMO-01RX (Receiver), OMO-01TX (sensor)
Freq. 433.92 MHz
La Crosse Technology
Made in China
WS-9046U
All rights reserved. This handbook must not be reproduced in any form, even in excerpts, or duplicated or processed using
electronic, mechanical or chemical procedures without written permission of the publisher.
This handbook may contain mistakes and printing errors. The information in this handbook is regularly checked and corrections
made in the next issue. We accept no liability for technical mistakes or printing errors, or their consequences.
All trademarks and patents are acknowledged.
18
|