Kramer Electronics Satellite Radio TP 100 User Manual

Kramer Electronics, Ltd.  
USER MANUAL  
Models:  
TP-100, XGA Line Transmitter  
TP-200, XGA Line Receiver  
 
ADDENDUM: Included with user manuals for machines with a CAT5 connector  
This addendum describes the Power Connect feature used with Kramer  
machines, and the choice between STP and UTP CAT5 cables.  
Power Connect Feature1  
The Power Connect feature lets you power a transmitter / receiver system by  
connecting just one power adapter to either the transmitter or the receiver. The  
other unit is fed over the same CAT5 cable.  
The Power Connect feature applies as long as the CAT5 cable is heavy gauge  
cable (that is, it can carry power). The distance does not exceed 50 meters on  
standard cable.  
For a distance of 100 meters, separate power supplies must be connected to the  
transmitter and to the receiver simultaneously, unless using heavy gauge CAT5  
cable.  
Shielded Twisted Pair (STP) / Unshielded Twisted Pair (UTP)  
The decision whether to use shielded twisted pair (STP) cable or unshielded  
twisted pair (UTP) cable depends on the nature of the application.  
It is recommended that in applications with high interference, shielded twisted  
pair (STP) cable will give better results. However, the shield itself does create a  
capacitance that degrades the frequency response of the machines. For shorter  
distances, of 50m or so, shielded twisted pair (STP) cable is preferred because it  
provides protection from interference (degradation is non-apparent).  
For a long range application, unshielded twisted pair (UTP) cable is preferred.  
However, the unshielded twisted pair (UTP) cable should be installed far away  
from electric cables, motors etc., which are prone to create electrical interference.  
1 This section of the addendum is only relevant to machines that support this feature (for example, the TP-104; not the  
TP-100)  
P/N: 2900 – 9999991  
A1  
 
Introduction  
1
Introduction  
Welcome to Kramer Electronics (since 1981): a world of unique, creative and  
affordable solutions to the infinite range of problems that confront the video,  
audio and presentation professional on a daily basis. In recent years, we have  
redesigned and upgraded most of our line, making the best even better! Our  
350-plus different models now appear in 8 Groups1, which are clearly defined  
by function.  
In addition to our high quality twisted-pair interfaces, like the TP-100 XGA  
Line Transmitter and the TP-200 XGA Line Receiver, we also offer excellent  
switchers and matrices, distribution amplifiers, presentation processors,  
remote controllers and computer-related products. Congratulations on  
purchasing your Kramer TP-100 XGA Line Transmitter and the TP-200 XGA  
Line Receiver. These products are ideal for utilizing existing UTP cabling that  
results in an efficient, fast and uncluttered environment for:  
Studios, airports, offices and hospitals  
Security and military applications  
The package includes the following items:  
TP-100 XGA Line Transmitter and/or TP-200 XGA Line Receiver  
Power cord(s)  
This user manual2 and the Kramer concise product catalog/CD  
2
Getting Started  
We recommend that you:  
Unpack the equipment carefully and save the original box and packaging  
materials for possible future shipment  
Review the contents of this user manual  
Use Kramer high performance high resolution cables3  
1 GROUP 1: Distribution Amplifiers; GROUP 2: Video and Audio Switchers, Matrix Switchers and Controllers; GROUP 3:  
Video, Audio, VGA/XGA Processors; GROUP 4: Interfaces and Sync Processors; GROUP 5: Twisted Pair Interfaces;  
GROUP 6: Accessories and Rack Adapters; GROUP 7: Scan Converters and Scalers; and GROUP 8: Cables and Connectors  
in the Products section)  
1
 
Overview  
3
Overview  
The TP-100 XGA Line Transmitter and TP-200 XGA Line Receiver constitute  
an extendable branching set of VGA/XGA-to-Twisted Pair Transmitter and  
Receiver. The input looping capability of the TP-100 and the transceiving  
ability of the TP-200 create a multimode XGA/CAT5 distribution system.  
The TP-100 XGA Line Transmitter includes:  
A looping XGA input (with termination switch)  
ID Bit control  
2 CAT5 outputs for simultaneous signal transmission to 2 locations  
Individual cable EQ. control for each CAT5 output  
The TP-200 XGA Line Receiver:  
Receives the CAT5 signal, decodes it and simultaneously distributes it to  
3 XGA outputs and relays the input to the next receiver (transceiver operation)  
Includes an EQ. control for the decoded XGA signal and an EQ. control  
for the signal re-transmitted to the next receiver  
Achieving the best performance means:  
Connecting only good quality connection cables, thus avoiding  
interference, deterioration in signal quality due to poor matching, and elevated  
noise levels (often associated with low quality cables)  
Avoiding interference from neighboring electrical appliances that may  
adversely influence signal quality and positioning your TP-100 and/or TP-200  
in a location free from moisture and away from excessive sunlight and dust  
KRAMER: SIMPLE CREATIVE TECHNOLOGY  
2
 
Your XGA Line Transmitter and the XGA Line Receiver  
4
Your XGA Line Transmitter and the XGA Line Receiver  
Figure 1, Table 1 and Table 2 define the TP-100:  
Figure 1: TP-100 XGA Line Transmitter  
Table 1: Front Panel TP-100 XGA Line Transmitter Features  
#
1
2
3
Feature  
Function  
POWER Switch Illuminated switch supplying power to the unit  
Out 2 EQ. Knob Adjusts the equalization control level (EQ.) for the CAT5 Line 2 output  
Out 1 EQ. Knob Adjusts the equalization control level (EQ.) for the CAT5 Line 1 output  
Table 2: Rear Panel TP-100 XGA Line Transmitter Features  
#
Feature  
Function  
1
2
XGA Input HD15 Connector Connects to the video source  
ID Bit (OFF / ON) Button  
Pushing in selects the ID BIT (when outputting a VGA signal from a  
laptop to an external VGA monitor1); releasing deactivates the ID BIT  
Term (Hi-Z / 75) Button  
XGA Loop HD15 Connector For looping to a VGA acceptor  
Line 1 OUT CAT5 Connector Connects to the Line IN connector on the TP-200 XGA Line Receiver3  
Line 2 OUT CAT5 Connector Connects to the Line IN connector on the TP-200 XGA Line Receiver3  
Power Connector with FUSE AC connector enabling power supply to the unit  
Pushing in selects 75; releasing selects Hi-Z2  
3
4
5
6
7
1 Sometimes laptop computers refuse to output a VGA signal to an external VGA monitor. By setting the ID Bit to ON (and  
using pin # 4 on the VGA connector that is normally unused), the laptop computer will output to an external VGA monitor  
2 For looping select Hi-Z  
3 Using a UTP cable with CAT5 connectors at both ends  
3
 
Your XGA Line Transmitter and the XGA Line Receiver  
Figure 2, Table 3 and Table 4 define the TP-100:  
Figure 2: TP-200 XGA Line Receiver  
Table 3: Front Panel TP-200 XGA Line Receiver Features  
#
1
2
Feature  
Function  
POWER Switch  
Illuminated switch supplying power to the unit  
Line Out EQ. Knob Adjusts the equalization control level (EQ.) for the signal transmitted via the  
CAT5 Line output to the next XGA Line Receiver  
3
XGA Out EQ. Knob Adjusts the equalization control level (EQ.) for the decoded XGA signal  
Table 4: Rear Panel TP-200 XGA Line Receiver Features  
#
1
2
3
4
5
6
Feature  
Function  
Line IN CAT5 Connector  
Line OUT CAT5 Connector  
Connects to the Line OUT connector on the XGA Line Transmitter  
Connects to the Line IN connector on the next XGA Line Receiver  
XGA OUT 1 HD15 Connector Connects to the video acceptor 1  
XGA OUT 2 HD15 Connector Connects to the video acceptor 2  
XGA OUT 3 HD15 Connector Connects to the video acceptor 3  
Power Connector with FUSE  
AC connector enabling power supply to the unit  
KRAMER: SIMPLE CREATIVE TECHNOLOGY  
4
 
Connecting a XGA/CAT5 Distribution System  
5 Connecting a XGA/CAT5 Distribution System  
To configure a XGA/CAT5 distribution system consisting of two TP-100  
XGA Line Transmitter units and two (transceiver) TP-200 XGA Line Receiver  
units, as Figure 3 illustrates, do the following:  
1. Connect a XGA source (for example, a laptop1) to the XGA Input  
connector on the first TP-100 XGA Line Transmitter unit.  
2. Connect the first TP-100 XGA Line Transmitter unit’s XGA Loop  
connector to the XGA Input connector on the second TP-100 XGA Line  
Transmitter unit2.  
3. Connect the first TP-100 XGA Line Transmitter unit’s Line 1 OUT  
connector to the Line IN connector on the first TP-200 XGA Line  
Receiver unit.  
4. Connect the first TP-100 XGA Line Transmitter unit’s Line 2 OUT  
connector to the Line IN connector on an additional TP-200 XGA Line  
Receiver unit.  
5. Connect the first TP-200 XGA Line Receiver unit’s Line OUT connector  
to the Line IN connector on the second TP-200 XGA Line Receiver unit.  
6. Connect the XGA outputs on both TP-200 Line Receiver units to their  
respective XGA acceptors.  
7. Connect the power cord on each unit to the electricity supply.  
1 Push in the ID Bit button to ON  
2 Release the Term button to HI-Z on the first unit and push in the Term button to 75 on the second unit  
5
 
Connecting a XGA/CAT5 Distribution System  
Figure 3: Multimode XGA/CAT5 Distribution System  
KRAMER: SIMPLE CREATIVE TECHNOLOGY  
6
 
Technical Specifications  
6
Technical Specifications  
Table 5 defines the technical specifications1:  
Table 5: Technical Specifications2 of the TP-100 / TP-200  
INPUTS:  
TP-100: 1 XGA input on an HD15F connector; 1 XGA Loop on an HD15F connector  
TP-200: 1 UTP CAT5 connector (Line IN)  
OUTPUTS:  
TP-100: 2 UTP CAT5 connectors (Line 1 OUT; Line 2 OUT)  
TP-200: 1 UTP CAT5 connector (Line OUT); 3 XGA outputs on HD15F connectors  
MAX. OUTPUT LEVEL: 1.5 Vpp / 75  
DIFF. GAIN (Pair):  
DIFF. PHASE (Pair):  
K-FACTOR (Pair):  
S/N RATIO (Pair):  
RESOLUTION:  
RANGE:  
0.23% (optimum)  
0.19 Deg (optimum)  
<0.05% (optimum)  
70dB (optimum)  
Up to UXGA  
Up to 150m with CAT5 UTP  
CONTROLS:  
(30m):  
TP-100: Line Out E.Q.: 0 to 7.8dB @ 20MHz  
TP-200: XGA Out E.Q.: 0 to 3.2dB @ 20MHz  
COUPLING:  
DC  
POWER SOURCE:  
DIMENSIONS:  
WEIGHT:  
TP-100 / TP-200: 230 VAC, 50/60 Hz. (115VAC, U.S.A.) 13 VA  
22cm x 18cm x 4.5cm (8.6” x 7” x 1.8”), W, D, H.  
1.2 kg. (2.65 lbs.) approx.  
ACCESSORIES:  
OPTIONS:  
Power cords  
19” rack adapters RK-80 (holds two units)  
1 Specifications for 30m of CAT5 UTP cable, unless otherwise specified  
2 Specifications are subject to change without notice  
7
 
LIMITED WARRANTY  
Kramer Electronics (hereafter Kramer) warrants this product free from defects in material and workmanship under the  
following terms.  
HOW LONG IS THE WARRANTY  
Labor and parts are warranted for three years from the date of the first customer purchase.  
WHO IS PROTECTED?  
Only the first purchase customer may enforce this warranty.  
WHAT IS COVERED AND WHAT IS NOT COVERED  
Except as below, this warranty covers all defects in material or workmanship in this product. The following are not covered by  
the warranty:  
1.  
Any product which is not distributed by Kramer, or which is not purchased from an authorized Kramer dealer. If you are  
uncertain as to whether dealer is authorized, please contact Kramer at one of the agents listed in the web site  
a
2.  
3.  
Any product, on which the serial number has been defaced, modified or removed.  
Damage, deterioration or malfunction resulting from:  
i)  
ii)  
iii)  
iv)  
v)  
Accident, misuse, abuse, neglect, fire, water, lightning or other acts of nature  
Product modification, or failure to follow instructions supplied with the product  
Repair or attempted repair by anyone not authorized by Kramer  
Any shipment of the product (claims must be presented to the carrier)  
Removal or installation of the product  
vi)  
vii)  
Any other cause, which does not relate to a product defect  
Cartons, equipment enclosures, cables or accessories used in conjunction with the product  
WHAT WE WILL PAY FOR AND WHAT WE WILL NOT PAY FOR  
We will pay labor and material expenses for covered items. We will not pay for the following:  
1.  
2.  
Removal or installations charges.  
Costs of initial technical adjustments (set-up), including adjustment of user controls or programming. These costs are the  
responsibility of the Kramer dealer from whom the product was purchased.  
3.  
Shipping charges.  
HOW YOU CAN GET WARRANTY SERVICE  
1.  
2.  
To obtain service on you product, you must take or ship it prepaid to any authorized Kramer service center.  
Whenever warranty service is required, the original dated invoice (or a copy) must be presented as proof of warranty coverage,  
and should be included in any shipment of the product. Please also include in any mailing a contact name, company, address, and  
a description of the problem(s).  
3.  
For the name of the nearest Kramer authorized service center, consult your authorized dealer.  
LIMITATION OF IMPLIED WARRANTIES  
All implied warranties, including warranties of merchantability and fitness for a particular purpose, are limited in duration to  
the length of this warranty.  
EXCLUSION OF DAMAGES  
The liability of Kramer for any effective products is limited to the repair or replacement of the product at our option. Kramer  
shall not be liable for:  
1.  
Damage to other property caused by defects in this product, damages based upon inconvenience, loss of use of the product, loss  
of time, commercial loss; or:  
2.  
Any other damages, whether incidental, consequential or otherwise. Some countries may not allow limitations on how long an  
implied warranty lasts and/or do not allow the exclusion or limitation of incidental or consequential damages, so the above  
limitations and exclusions may not apply to you.  
This warranty gives you specific legal rights, and you may also have other rights, which vary from place to place.  
NOTE: All products returned to Kramer for service must have prior approval. This may be obtained from your dealer.  
This equipment has been tested to determine compliance with the requirements of:  
EN-50081:  
"Electromagnetic compatibility (EMC);  
generic emission standard.  
Part 1: Residential, commercial and light industry"  
"Electromagnetic compatibility (EMC) generic immunity standard.  
Part 1: Residential, commercial and light industry environment".  
FCC Rules and Regulations:  
EN-50082:  
CFR-47:  
Part 15: “Radio frequency devices  
Subpart B – Unintentional radiators”  
CAUTION!  
Servicing the machines can only be done by an authorized Kramer technician. Any user who makes changes or modifications to  
the unit without the expressed approval of the manufacturer will void user authority to operate the equipment.  
Use the supplied DC power supply to feed power to the machine.  
Please use recommended interconnection cables to connect the machine to other components.  
KRAMER: SIMPLE CREATIVE TECHNOLOGY  
8
 
For the latest information on our products and a list of Kramer  
Updates to this user manual may be found at  
We welcome your questions, comments and feedback.  
Kramer Electronics, Ltd.  
P/N: 2900-000100 REV 1  
 

Insignia Portable DVD Player NS D9PDVD15 NS D9PDVD15 MX User Manual
Insignia TV DVD Combo NS LTDVD26 09 User Manual
JVC Camcorder GR AX230 User Manual
JVC Car Video System KD DV6201 User Manual
JVC DVD Player XV 515GD User Manual
JVC Portable CD Player CA PCX290 User Manual
Kelvinator Washer Dryer KL72TT User Manual
Kenwood Car Speaker KFC 136E User Manual
KitchenAid Ventilation Hood KICU265BAL0 User Manual
Korg Electronic Keyboard C 150 User Manual